• Title/Summary/Keyword: 측정학

Search Result 18,851, Processing Time 0.05 seconds

Study of Effects of Measurement Errors in Damage Detection (동적 측정오차가 손상탐지에 미치는 영향에 관한 연구)

  • Kim, Ki-Ook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.3
    • /
    • pp.218-224
    • /
    • 2011
  • A modal method is presented for the investigation of the effects of measurement errors in damage detection for dynamic structural systems. The structural modifications to the baseline system result in the response changes of the perturbed structure, which are measured to determine a unique system in the inverse problem of damage detection. If the numerical modal data are exact, mathematical programming techniques can be applied to obtain the accurate structural changes. In practice, however, the associated measurement errors are unavoidable, to some extent, and cause significant deviations from the correct perturbed system because of the intrinsic instability of eigenvalue problem. Hence, a self-equilibrating inverse system is allowed to drift in the close neighborhood of the measured data. A numerical example shows that iterative procedures can be used to search for the damaged structural elements. A small set of selected degrees of freedom is employed for practical applicability and computational efficiency.

On the in situ Measurement Method of Headphones using Head And Torso Simulator (HATS를 이용한 헤드폰의 in situ 측정방법에 관하여)

  • Kang, Kyeong-Ok;Kang, Seong-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.15-27
    • /
    • 1992
  • The standard measuring method of the frequency characteristics of headphones has been needed because different results come from the different measuring methods because of the lack of the reasonable measuring method of headphone characteristics, for example, in the case of psycho-acoustic experiments with headphones. In this paper, based on this fact, we studied the measurement method of headphones based on the natural hearing condition of human being, that is in situ measuring method, by measuring the headphone frequency characteristics using an artificial ear and a newly proposed device, HATS(Head And Torso Simulator). From the result of this paper, we could see that the method appropriate to a so called in situ condition was the one wi9th HATS, Because HATS simulated more correctly the acoustic impedance of the ear and the diffraction effect of the human head than the artificial ear.

  • PDF

Uncertainty Analysis about the Change of Partial Section of Discharge Measurement (유량측정에 따른 측선수 변화에 대한 불확도 분석)

  • Kim, Jung-Nam;Lee, Jae-Hyug;Jeon, Byung-Hark;Kim, Sung-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.688-688
    • /
    • 2012
  • 불확도의 요인은 유속-면적법에 적용되는 방정식의 일반화된 형태를 고려하여 나타낼 수 있다. 하천에 대한 불확도, 수심에 대한 불확도, 점 유속의 결정에 대한 불확도, 평균유속의 예측과 유량에 대한 불확도가 불확도산정에 많은 영향을 미치는 요소라 할 수 있다. 유량측정을 실시할 때 불확도를 개선하기 위해서는 유속에 비례하여 측선수를 조절함이 좋은 등급을 확보하기에 성과의 품질 향상에 크게 기여하는 결과를 얻을 수 있다. 본 연구에서는 자연하천의 현장지점에서 실시간 수위를 확인하며 유속을 측정하였고, 측정 성과를 이용하여 유량과 불확도를 산정, 비교 분석하였다. 유량측정에 있어 측정 기기로는 국내에서 일반적으로 사용되는 회전식 유속계(PriceAA)를 사용하여 측정을 실시하였으며, 측정방법으로는 도섭법을 기준으로 1점법, 2점법, 3점법에 이르게 다양한 성과를 실측하여 측정한 결과에 적용된 측선수에 따른 불확도를 분석하였다. 그 결과 0.5 m/s 이하의 유속과 $1.5m^3/s$ 의 유량에서는 그림 2에서 제시하였듯 30개 이상의 측선수를 확보하므로 5 % 미만의 2등급을 확보할 수 있었다. 그림 3은 9개의 지점 28회의 측정 결과를 측선수별 평균 불확도를 산정하여 유속 0.5m/s ~ 0.7m/s의 범위에서는 30개 미만의 측선수를 확보하여도 2등급의 품질을 확보할 수 있었으며, 이는 유속과 측선수의 관계를 나타내는 결과이다. 따라서 측정 자료의 신뢰성을 확보할 수 있는 2등급 이상을 얻기 위해서는 국제기준(ISO 748)에 따른 측선수를 적용하되 현장지점의 특성에 따라 유속을 고려한 측선수를 적용하는 것이 필요할 것으로 판단된다.

  • PDF

Elapsed-time Method With Tacho Pulse Non-uniformity Correction (타코펄스 불균일성 보정이 포함된 펄스간 시간 측정방법)

  • Son, Jun-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.4
    • /
    • pp.269-275
    • /
    • 2022
  • In ideal configuration, elapsed-time method can measure the exact reaction wheel speed. But in real configuration, the speed measurement error exists due to tacho pulse non-uniformity. In this research, we study the method which overcome the non-uniformity effects. First, we introduce the method which spin the wheel at the specific speed and measure the non-uniformity. Then, we propose the real-time measurement error correction method which uses the obtained non-uniformity information. This method calculate the speed candidates from the elapsed-time method's counts and non-uniformity information, and choose the closest speed to the real speed. Through simulation, we show that proposed method measure the exact speed regardless of non-uniformity, and fast wheel speed control is possible.

Reverse engineering technique on the evaluation of impression accuracy in angulated implants (경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법)

  • Jung, Hong-Taek;Lee, Ki-Sun;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.261-270
    • /
    • 2021
  • Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.

Multi-Section Flow Measurement Method Using Radar(Electromagnetic) Surface Flow meter (레이더(전자파) 표면유속계를 이용한 다측점 유량측정 방법)

  • Kwang Tae Choi;Jang Hyun Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.449-449
    • /
    • 2023
  • 유량은 도섭법, 보트법, 횡측선법, 교량법 및 부자법 등 다양한 방법으로 측정되는데, 이들 측정방법 모두 많은 수의 관측자를 필요로 한다. 이들은 하천에 직접 들어가서 측정하거나, 인공구조물인 교량과 재방에서 측정되는데, 도섭법, 보트법, 횡측선법이 전자이며, 고수위 및 고유속으로 하천에 들어가지 못하는 경우에는 교량법 및 부자법을 사용하여 유량을 측정한다. 최근 지구 온난화로 따른 이상 기후가 빈번히 발생하고 있으며, 이로 인한 많은 피해가 발생하고 있어, 하천 수위, 유속 모니터링에 대한 중요성이 더 커지고 있다. 2022년 1월부터 시행 중인 「중대재해처벌법」으로 집중호우 및 일몰 이후에는 안전상의 문제로 유량측정이 어려운 상황으로 필요한 시기에 유량 데이터를 확보에 제약이 있다. 이에 관측자 없이도 유량을 측정할 수 있는 방법을 이용하여 중대 재해의 위험성을 해소하고자 하였다. 유량측정 방법으로 설치 회수가 용이한 비접촉 방식에서 영상표면유속측정 방식과 레이더(전자파)표면 유속측정 방식 중, 집중호우 및 태풍 발생 중 가시성이 확보되지 않아도 측정이 가능한 레이더(전자파) 표면유속계를 이용한 다측점 유량측정 방법을 개발하였다. 비접촉 다측점 유량측정시스템 Master 1대에 8대의 Slave를 연결할 수 있어 총 9개의 측선을 측정할 수 있게 개발하였다. 특히, 하천 및 수로 등의 표면 유속을 비접촉으로 측정하고 하천 단면을 이용하여 유량측정이 가능한 장비로 별도의 수중 및 수상 주조물 작업이 필요 없고 장비의 손상 및 유실 가능성이 거의 없고 역류 상태에서도 측정이 가능하다. 유속은 24GHz의 레이더 주파수를 송수신하여 도플러 변이를 이용하여 측정하였고, 수위는 80GHz의 레이더 주파수를 사용하여 왕복 시간을 거리로 환산하여 측정하였다. 유량은 각각의 유속계에 단면을 입력해 놓으면 유속분포법, 중간단면적법 및 지표유속법을 적용하여, 각각의 측선에 대한유량과 총 유량을 산출하였다. 그 결과, 기존 방식 대비 상당한 개선 효과를 확인하였고, 향후 환경부 등 중앙부처의 수문조사 사업에서 그 역할이 기대된다.

  • PDF

Establishment of the Electromagnetic Shielding Effectiveness Measurement System (전자파차폐효과 측정시스템의 구현)

  • 정연춘;강태원;정낙삼
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.3
    • /
    • pp.45-53
    • /
    • 1993
  • The shielding effectiveness of materials is determined by measuring the ratio of the incident electromagnetic power to that which passes through the material under test. The measurement system is constructed using several test fixtures, tracking generator, spectrum analyzer, step attenuator, RF switches, and amplifiers, etc.. The automation of measurements is completed using a personal computer. Especially, incident power, reflected power, and transmitted power are measured with only one spectrum analyzer using a dual directional coupler and RF switches. Therefore the system is to be used in design of shielding materials, as well as shielding effectiveness measurements. This system has dynamic range of more than 120 dB in the frequency range of 10 MHz to 1 GHz, and it can be used to measure shielding effectiveness of composite materials.

  • PDF

A Study on the Method of Measuring the Economic Use Value of Public Libraries (공공도서관 경제적 이용가치 측정방안에 관한 연구)

  • Pyo, Soon-Hee;Jeong, Dong-Youl
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.42 no.2
    • /
    • pp.209-234
    • /
    • 2008
  • According to increasing the benefits from public libraries, there are many studies for measuring the library value. This study presents a methodology for measuring use value of the public library in terms of time value, surplus value of alternative service, value of library service, and overall value of library. The cost-benefit ratio of the time value compared to library's annual budget is 11:1, and the cost-benefit ratio of the overall library value was measured by user's WTP is 0.3:1. This study proposed the method for measuring use value of the public library according to the process, the results of these measurments for each value and the factors affecting the values.

Evaluation of Performance Measurement System Alternatives for Construction Companies (건설기업에 적합한 성과측정시스템/Framework의 대안 평가)

  • Kim Ki-Hyon;Yu Il-Han;Shin Dong-Woo;Kim Kyung-Rai
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.398-403
    • /
    • 2004
  • Construction companies have been required high technique and integration of management. Because they not only have got high competition, variation of customer's demands, social and economical changes but also more complex and specialization. Construction companies require performance measurement to exclude inefficiency and be aware of their business performance level, but domestic construction industry does not have adequate performance measurement system like as manufacture industry or business administration. So this paper evaluate of performance measure system alternatives for construction companies.

  • PDF

Comparison of Thrust Measurement of a Supersonic Wind Tunnel (초음속 풍동의 추력 측정 방법 비교)

  • Heo, Hwan Il;Kim, Hyeong Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.93-99
    • /
    • 2003
  • The determination of thrust is essential in design and evaluation of a hypersonic airbreathing propulsion device. Conventional methods to determine the thrust is using thrust stand or force measurement system. However, these conventional methos are not applicable to the case where thrusts stands are impractical, such as free jet testing of engines, and model combustor. For this reason, the thrust determination method from measured pitot pressure is considered and validated. Validation of thrust determination from pitot pressures can be achieved by comparing the actual thrust from thrust stand. For validation purpose, a small-scale supersonic wind tunnel is installed on the thrust stand. Thrusts are measured while pressures are measured simulaneously. Then, the thrust from pitot pressure measurements are compared with the measured thrust and theoretical thrusts.