• Title/Summary/Keyword: 측정소

Search Result 1,923, Processing Time 0.035 seconds

Radiocarbon Dating of a Wooden Board from Jeongsusa Temple Using Wiggle Matching of Quinquennial Tree-Ring Samples (5년 간격 연륜의 위글매치를 이용한 정수사 법당 목부재의 방사성탄소연대 측정)

  • Nam, Tae-Kwang;Park, Jung-Hun;Hong, Wan;Park, Won-Kyu
    • Journal of Conservation Science
    • /
    • v.28 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • This paper reports the application of radiocarbon wiggle-matching for Korean wooden artifacts such as buildings and Buddhist statues for precise dating. Nine quinquennial (every five-year) samples of 41 years (AD 1250-1290) for AMS radiocarbon measurements were prepared from a wooden board used for the Main Hall at Jeongsusa (temple) in Kangwhado, Korea, which was dendrochronologically dated. The 95.4% confidence interval of radiocarbon dating prior to wiggle matching was 113.3 year in average. When wiggle-matching technique was applied, it became 20 years, 5.7 times smaller than that produced without wiggle matching. The results indicated that wiggle-matching technique using the calibration curve for northern hemisphere (IntCal04) can produce precise dates for Korean wooden artifacts, at least, for the $13^{th}$ century.

Statistical Analysis for Ozone Long-term Trend Stations in Seoul, Korea (통계적 기법을 적용한 서울의 오존 장기변동 대표측정소 선정)

  • Shin, Hyejung;Park, Jihoon;Son, Jungseok;Rho, Soona;Hong, Youdeong
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.2
    • /
    • pp.111-118
    • /
    • 2015
  • This study was conducted for the establishment of statistical method to determine the representative air quality monitoring station representing long-term ozone trends of Seoul. In this study, hourly ozone concentrations from 2002 to 2011 were used for further analysis. KZ-filter, correlation matrix, cluster analysis, and Kriging method were applied to select the representative station. The analysis based on correlation matrix found that long-term trend of ozone concentrations measured at Sinjung, Sadang, and Bun-dong showed a high correlation. The cluster analysis found that the former three stations belonged to the same cluster. The analysis based on Kriging method also showed that the former three stations were highly correlated with other stations in spatial distribution. Considering these results and the highest correlation coefficient of Sinjung station, the Sinjung station was the most suitable as the representative station used to understand the long-term ozone trend of Seoul. This result could be applied to understand long-term trend of other pollutants. Furthermore, this result can also be used to assess the appropriacy of spatial distribution of national air quality monitoring stations.

The Allocation Analysis of Air Pollution Monitoring Stations Using GIS (GIS를 이용한 대기오염측정망의 적정성 분석)

  • Choi, Byoung-Gil;Kim, Joong-Sik;Ra, Young-Woo;Lee, Cheol-Joon
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.113-119
    • /
    • 2004
  • 본 연구의 목적은 GIS를 이용하여 대기오염측정망의 적정성을 분석하는데 있다. 측정소 이력, 분포의 적정성, 주위의 토지이용상태의 분포현황 분석을 통하여 인접지역이거나 주변 토지이용상태가 유사할 경우 측정값의 변화추이가 유사하게 나타남을 알 수 있었으며 현재 대부분의 측정소가 주거지역에 설치되어 있음을 알 수 있었다. 또한 대기오염측정소 배치방법에 의한 측정소의 개수를 산정한 결과가 현재 설치되어 있는 측정소의 이전과 추가적인 설치가 필요한 것으로 나타났다. 토지이용상태와의 상관분석을 통해 오염원에 대한 정확한 파악과 오염물질의 이동경로에 대한 추적을 통하여 도시계획사업수립 등에 활용될 수 있을 것이다.

  • PDF

Adenosine triphosphate (ATP) bioluminescence assay for hygiene control monitoring at children's foodservice facilities in Anyang area (안양지역 어린이급식소에서의 위생관리 모니터링을 위한 adenosine triphosphate(ATP) 분석법 적용)

  • Kim, Hye Won;Pie, Jae Eun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.335-342
    • /
    • 2021
  • In this study, we identify the suitability of monitoring the hygiene control of meals using ATP bioluminescence assay in children's foodservice facilities. Most ATP measured value by measurement area in childcare centers were lower in the second round than in the first round, and most hygiene control suitable rate by measurement area in childcare centers and kindergartens was higher in the second round. Also, in childcare centers, there was a positive correlation between the number of ATP measurement and the average score. In conclusion, ATP bioluminescence assay could be available as a monitoring tool for meal hygiene control in children's foodservice facilities, especially in childcare centers.

Correction of discharge data_Case of measurement location separated from the gauging station (유량자료의 보정_관측소와 이격된 측정위치 경우)

  • Hwang-Bo, Jong Gu;Baek, Kyung Ho;Yun, Hyun Guk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.319-319
    • /
    • 2021
  • 유량측정은 측정방법에 따라 측정위치가 변동된다. 도섭법은 관측자가 직접 하천을 횡단하며 측정하는 방법이며 수심이 얕은 경우 가능하다. 보트법의 경우 상대적으로 공간적 제약을 덜 받으며 교량법의 경우 이용 가능한 교량이 있어야 한다. 따라서 교량법은 현장여건에 따라 관측소와 멀리 떨어져 있는 경우가 있으며 이 경우 측정된 유량을 이용하여 수위-유량관계곡선식을 개발한다면 그 정확도가 떨어질 수 있다. 미국지질조사국(USGS)에서는 관측소와 측정위치가 멀리 떨어진 경우 측정된 유량을 보정하도록 규정하고 있다. 우리나라의 경우 유량 보정을 실시하지 않는 것으로 파악되었다. 하지만 이는 수위-유량관계곡선식, 특히 외삽부분에서 큰 오류를 유발할 수도 있어 신중할 필요가 있다. 본 연구에서는 수위관측소와 측정위치가 현저하게 먼 경우 유량 보정방법을 살펴보고 실측유량과 보정유량의 차이를 확인하였다. 대상지점인 낙동강 유역의 안동시(운산리) 지점은 홍수측정위치와 수위관측소 위치가 약 1.7km 이격되어 있으며, 2020년 측정성과(부자)를 이용하여 이를 보정하고 그 차이를 확인하였다. 보정결과 실측유량과 보정유량이 최고 5.0%, 평균 3.7% 차이를 보이는 것으로 확인되었다. 안동시(운산리)지점은 2020년 측정 최고수위가 3.35m이며, 이는 평수위에서 약 2.00m 가량 상승한 것으로 최고 홍수위로 보기는 어렵다. 즉 이보다 더 큰 홍수 사상이 발생하여 수위가 더 상승한다면 실측유량과 보정유량의 차이는 더 커질 것으로 예상된다. 또한 수위관측소와 측정위치가 이격된 경우 측정된 성과가 루프(Loop) 형태를 보일 수 있어 보정이 필요한 것으로 판단된다.

  • PDF

Quality Evaluation of Strawberry Jams Prepared with Refined Dietary Fiber from Ascidian(Halocynthia roretzi) Tunic (우렁쉥이(멍게) 껍질로부터 정제된 섬유소 첨가 기능성 딸기잼의 품질평가)

  • Byun, Myung-Woo;Yook, Hong-Sun;Ahn, Hyun-Joo;Lee, Kyong-Haeng;Lee, Hyun-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.1068-1072
    • /
    • 2000
  • Strawberry jams were prepared with addition of 1.0 and 2.0% dietary fiber isolated from ascidian (Halocynthia roretzi) tunic for recycling wastes of seafood source and developing new food products. The texture of the jams examined were using a back extrusion rig. All of the rheological parameters decreased in the fiber-enhanced jams. Viscosity profiles were also decreased in the fiber-enhanced jam samples. Hunter L' and a' values increased in the fiber-enhanced jams, accordingly revealing reddish color. As a result of sensory evaluations, the result of taste tests and overall acceptability were significantly acceptable. In the list of acceptability factors, except spreadibility, jam where 1% fiber was added, high sensory scores and preferable acceptability were noted.

  • PDF

Effect of Medium and Small Scale Shipyard Operations on Environmental Pollutions Related with Civil Appeal (중.소규모 조선소 조업이 주요 민원 유발성 환경오염에 미치는 영향)

  • Chung, Jae-Woo;Lee, Myoung-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.1006-1012
    • /
    • 2008
  • The effect of small and medium scale shipyard operations on environmental pollutions related with civil appeal of nearby residential areas was estimated. PM-10(particles with an aerodynamic diameter less than or equal to 10 $\mu$m) concentrations were higher, as the sampling sites were nearer from shipyards. PM-10 concentrations of sampling sites closer to shipbuilding companies were higher during the normal operation periods than on vacation at which only small works were done. The larger amount of dry deposition was observed as the sampling sites were closer to shipyards. The odor intensity was highly influenced by ambient temperature. Almost all odor intensities measured by air dilution sensory test went over the emission standard in summer. Odor properties measured by instrumental analysis were observed to exceed the emission standard enforced to the shipyards. Odor compounds such as ammonia, sulfur compounds and trimethylamine went over the standard. Concentrations of styrene and aldehydes were lower than the olfactory threshold. All equivalent sound levels measured at daytime except the value of SP-3 pont were in excess of the environmental standard. Almost all sound levels at nighttime in all measuring sites were higher than the environmental standard. The results of this study shows counterplans need to be established for reducing the civil appeal related pollutions in the research areas.

Spatial Information Application Case for Appropriate Location Assessment of PM10 Observation Network in Seoul City (서울시 미세먼지 관측망 위치 적정성 평가를 위한 공간정보 활용방안)

  • Jeong, Jong-Chul
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.2
    • /
    • pp.175-184
    • /
    • 2017
  • Recently, PM10 is becoming a main issue in Korea because it causes a variety of diseases, such as respiratory and ophthalmologic diseases. This research studied to spatial information application cases for evaluating the feasibility of the location for PM10 observation stations utilizing Geogrphic Information System(GIS) spatial analysis. The spatial Information application cases for optimal location assessment were investigated to properly manage PM10 observation stations which are closely related with public spatial data and health care. There are 31 PM10 observation stations in Seoul city and the observed PM10 data at these stations were utilized to understand the overall assessment of PM10 stations to properly manage using interpolation methods. The estimated PM10 using Inverse Distance Weighted(IDW) and Kriging techniques and the map of PM10 concentrations of monitoring stations in Seoul city were compared with public spatial data such as precipitation, floating population, elementary school location. On the basis of yearly, seasonal and daily PM10 concentrations were used to evaluate the feasibility analysis and the location of current PM10 monitoring stations. The estimated PM10 concentrations were compared with floating population and calculated 2015 PM10 distribution data using zonal statistical methods. The national spatial data could be used to analyze the PM10 pollution distribution and additional determination of PM10 monitoring sites. It is further suggested that the spatial evaluation of national spatial data can be used to determine new location of PM10 monitoring stations.

Development of Post-Processing Software for Flow Measurement Results Analysis using RQ-30 (RQ-30을 활용한 유량 측정 결과 분석을 위한 후처리 소프트웨어 개발)

  • Geunsoo Son;JungHwan Chun;Seongcheol Kang;Youngbeen Kwon;Youngsin Roh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.420-420
    • /
    • 2023
  • 하천의 유량 자료는 하천 관리에 필수적인 요소로, 지속적인 유량측정을 위해 국가 유량 측정망을 구성하여 주요 지점을 대상으로 유량 측정을 수행하고 있다. 측정된 유량자료는 일반적으로 수위-유량 관계곡선식을 개발하여 제공되고 있으며, 홍수파와 배수 영향 등으로 인해 수위-유량 관계곡선식에서 발생하는 산포로 인한 신뢰도에 문제가 우려되는 경우에는 실시간의 정확한 유량자료를 제공하기 위해 H-ADCP를 설치하여 지표유속법 기반의 실시간 유량 자료 생산하여 제공하고 있다. 그러나 H-ADCP를 이용한 유량 측정 방법은 장비의 한계로 인해 상대적으로 규모가 작고 수심이 얕은 하천에 적용하기 어려운 문제가 있다. 따라서, 최근에는 자동유량관측소 지점 확대를 위해 비접촉식 유속계를 활용한 자동유량관측소 운영이 점차 고려되고 있다. 이에 따라 비접촉식유속계를 이용한 유량 측정 결과의 검증 및 유지 관리를 위한 소프트웨어가 필요하다. 이에 본 연구에서는 비접촉식유속계 중 전자파를 이용하여 수표면의 표면유속을 측정할 수 있는 장비인 RQ-30의 측정결과를 분석하기 위해 Microsoft Visual Studio(C#) 사용하여 측정결과의 검토 및 자료 관리를 위한 후처리 소프트웨어를 개발하였다. 개발한 소프트웨어는 측정 원시자료를 읽고, 도시하여 측정 결과를 확인할 수 있으며, 머신러닝 기반의 알고리즘을 적용하여 수위 및 유속 시계열 자료에서 발생하는 이상치를 탐색할 수 있도록 개발하였다. 그리고 탐지된 이상치에 대한 보정을 위해 선형보간, LOESS, SuperSmoother를 사용하여 이상치를 보정하여 결과를 도출할 수 있도록 개발하였다. 추후 본 연구를 통해 개발된 프로그램을 활용하여 측정 자료의 유지 관리 효율성을 증대시킬 수 있을 것으로 기대되며, 지속적인 프로그램의 개선을 통해서 실무적으로 활용이 가능할 것으로 판단된다.

  • PDF

섬유소분해효소유전자 (CelD)가 도입된 형질전환돼지의 섬유소 소화율 분석

  • 박진기;이연근;이현기;이풍연;최영진;김정호;김유경;김진회;장원경
    • Proceedings of the KSAR Conference
    • /
    • 2002.06a
    • /
    • pp.61-61
    • /
    • 2002
  • 비 반추동물 특히 돼지의 경우 섬유소 소화율이 극히 낮은 것으로 알려져 있다. 따라서 본 연구는 섬유소분해효소유전자 (CelD) 를 췌장특이 프로모터인 rat Elastase Ⅰ 하류에 연결하여 구축된 벡터를 수정란내 미세주입한 후 생산된 형질전환 돼지를 이용하여 섬유소 소화능력을 측정하기 위하여 실시하였다. 먼저 35두의 수란돈으로 부터 65 두의 산자를 생산하였으며, PCR 분석 결과 4두가 형질전환돼지로 판명되었으며 이중 3두가 죽고, 생존한 l두를 다시 southern blot 분석결과 형질 전환된 것으로 판단하여 같은 복의 6두와 함께 섬유소 소화율을 측정하기 위하여 분리사육을 실시하였다. (중략)

  • PDF