• Title/Summary/Keyword: 측정기준면

Search Result 484, Processing Time 0.031 seconds

Development of Natural and Ecological Wastewater Treatment System for Decentralized Regions and Rural Communities (분산지역 및 농촌마을 하수처리를 위한 자연정화 고도처리 공법 개발)

  • Kim, Song-Bae;Kwon, Tae-Young;Han, Jung-Yoon;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.4 s.118
    • /
    • pp.489-497
    • /
    • 2006
  • The feasibility of the Natural and Ecological Wastewater treatment System (NEWS) was examined for rural wastewater treatment in Korea. The intermittent trickling biofilter with high hydrophilic filter media was used for pretreatment for suspended solids and organic pollutants. The subsequent constructed wetland with porous granule materials was used for promoting nutrient removal. The results show that the removal efficiencies of the system were high with respect to the water quality parameters except COD. Even if the effluent from the biofilter did not meet the guidelines for wastewater treatment plant effluent in Korea in terms of $BOD_5$ and TN, the final effluent of the system meets the guidelines us to good performance of the constructed wetland. The regression analysis between pollutant loading rate and removal rate indicated that the system could have stable removal for SS, $BOD_5$, TN, and TP in the given influent ranges. The analysis in the winter period indicated that the wetland covered with transparent polycarbonate glass had the statble performance during the winter period dus to increase of temperature inside the wetland without any heating system. With the stable performance, effective poilutant removal, low maintenance, and cost-effectiveness, the NEWS could be considered as an alternative treatment system for decentralized regions and rural communities in Korea.

Thermal Environments of Children's Parks during Heat Wave Period (폭염 시 어린이공원의 온열환경)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.6
    • /
    • pp.84-97
    • /
    • 2016
  • This study was to investigate the user's thermal environments of the children's parks according to pavements and sunscreen types during periods of heat waves. The measurements were conducted at the sand pits, rubber chip pavement, shelters, and green shade ground of the two children's parks located in Jinju, Korea(Chilam: $N\;35^{\circ}11^{\prime}1.4{^{\prime}^{\prim}}$, $E\;128^{\circ}5^{\prime}31.7{^{\prime}^{\prime}}$, elevation 38m, Gaho: $N\;35^{\circ}09^{\prime}56.8{^{\prime}^{\prime}}$, $E\;128^{\circ}6^{\prime}41.1{^{\prime}^{\prime}}$, elevation 24m) over three days during 11-13, August, 2016. The highest ambient air temperatures at the Jinju Meteorological Office during the three measurement days were $35.9{\sim}36.8^{\circ}C$, which corresponded with the extremely hot weather. A series of experiments measured air temperature, relative humidity, wind velocity, black globe temperature, and long-wave and short-wave radiation of the six directions 0.6 m above ground level. The wet bulb globe temperature(WBGT) and the universal thermal climatic index(UTCI) were used to evaluate thermal stress. Surface temperature images of the play equipment were also taken using infrared thermography. Surface temperatures of the play equipment and grounds were used to evaluate burn risk through contact with playground materials. The results showed the following. The maximum air temperatures averaged over 1-hour period for three days were $36.6{\sim}39.4^{\circ}C$. The sun shades reduced those temperatures by up to $2.8^{\circ}C$(green shade) and $1.0^{\circ}C/2.3^{\circ}C$(shelters). The minimum relative humidity values averaged over 1-hour period for three days were 44~50%. The sun shades increased those humidity values by up to 6%(green shade) and 4%/6%(shelters). The risk of heat related illness at the measurement sites of the children's parks were extreme and high in the daytime hours. The maximum WBGT values averaged over a 30-minute period for three days were $31.2{\sim}33.6^{\circ}C$. The sun shades reduced those WBGT values by up to $2.4^{\circ}C$(green shade) and $0.5^{\circ}C/2.1^{\circ}C$(shelters) compared to sandpits, but would not block the risk of heat related illness in the daytime hours. The category of heat stress at the measurement sites of the children's parks were extreme and very strong in the daytime hours. The maximum UTCI values averaged over a 30-minute period for three days were $39.9{\sim}48.1^{\circ}C$. The sun shades reduced those UTCI values by up to $7.8^{\circ}C$(green shade) and $4.1^{\circ}C/8.2^{\circ}C$(shelters) compared to sandpits, but could not lower heat stress category from extreme and very strong to strong and moderate in the daytime hours. According to the burn threshold criteria when skin was in contact with playground materials, the maximum surface temperature of the stainless steels($70.8^{\circ}C$) surpassed three seconds $60^{\circ}C$ threshold for uncoated steel, that of the rubber chip($76.5^{\circ}C$) surpassed five seconds $74^{\circ}C$ threshold for the plastic, that of the plastic slide($68.5^{\circ}C$) and seats($71.0^{\circ}C$) surpassed the one min $60^{\circ}C$ threshold for plastic, respectively. The surface temperatures of shaded play equipment were lower approximately $20^{\circ}C$ than those of play equipment exposed to the sun. Therefore, sun shades can block the risk of burns in daytime hours. Because of the extreme and high risk of heat related illness and extreme and high heat stress at the children's parks during periods of heat waves, parents and administrators must protect children from the use of playgrounds. The risk of burn when contact with play equipments and grounds at the children's parks during periods of heat waves, was very high. The sun shades are essential to block the risk of burn from play equipments and grounds at the children's parks during heat waves.

Performance Evaluation of WWTP Based on Reliability Concept (신뢰성에 기초한 하수처리장 운전효율 평가)

  • Lee, Doo-Jin;Sun, Sang-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.348-356
    • /
    • 2007
  • Statistical and probabilistic method was used in the analysis of data, which is the most effective one in describing the various natures, and the methodology relating the results with the design was developed. Influents and effluents of three treatment plants were analyzed and the focus was made on BOD, COD, SS, IN, TP The fluctuations of influent such as BOD, COD, SS were extremely large and their standard deviations(st.dev) were more than 10 mg/L. but those of TN, TP were small; the st.dev was 6.6 mg/L for TN, 0.6 mg/L for TP, respectively. But, effluent concentration showed consistent pattern regardless of the influent fluctuations, the st.dev was ranged between 0.28 and 4.48 mg/L. Effluent distributional characteristics were as follows; BOD, COD were distributed normally, but SS, TN, and TP, log-normally; unsymmetric and skewed to the right. The coefficient of reliability(COR) based on the results of statistics of data was introduced to evaluate the process performance an4 to reflect the process performance to the process design. The coefficient of reliability relates the design value(the goal) with the standards and it can be used in operating treatment facilities under a certain reliability level and/or in evaluating the reliability of the treatment facilities on operation. Each treated water quality of effluent showed the half of water quality standards in the level of 50% percentile and all treatment plant was achieved 100% probability of water quality standards. It was concluded that the variability of the process performance should be reflected to the design procedure and the standards through the analysis based on the statistics and the probability.

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

A Study on the Changes of Accommodative Function in Respect to the Viewing Angle (주시각도에 따른 조절기능의 변화)

  • Lee, Hark-Jun;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: The purpose of this study was to examine the relationship between the accommodative facility, blink rate and accommodative lag according to the change of angles of main viewpoint of near distance worker and study an appropriate viewing angle that mitigates asthenopia, such as headaches or eye fatigue accompanied when reading and staring at the computer or TV for a long time. Methods: Total of 27 people including 12 male university students and 15 female university students in the age of 20 to 36 with frequent near distance works, such as computers, were selected to study the accommodative facility, the blink rate and the accommodative lag in accordance with the change of viewing angles of the near distance workers. The refraction error was corrected completely and the phoropter was shifted to near distance mode to locate the near distance indication at 40 cm. The accommodative facility and the blink rate were measured for one minute at each viewing direction of $40^{\circ}$ downward, $20^{\circ}$ downward, horizontal, and $20^{\circ}$ upward directions based on the horizontal line and the accommodative lag was measured in dynamic retinoscopy using retinoscope. Results: As a result, when the main viewpoint was moved on upper direction from the $40^{\circ}$ below, the accommodative facility was reduced and the blink rate and the accommodative lag were increased so their eyes became dry and the accommodation response was reduced. Conclusions: In near distance works, the eye fatigue level can be minimized by locating a book or a computer screen $40^{\circ}$ below than the horizontal direction.

  • PDF

An Analysis of Inquiry Activities in the Chemistry Parts of Middle School Science Textbook Based on the Sixth Curriculum (제 6차 교육과정에 따른 중학교 과학(화학부분) 교과서의 탐구활동 분석)

  • Moon, Seong Bae;Jun, Sung Ae;Kim, Yun Hi
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.2
    • /
    • pp.162-176
    • /
    • 2001
  • This study was covered with the analysis of five kinds of the middle school science text books(chemistry part) based on the oth curriculum. Particularly, inquiry activities part was analyzed by the three dimension framework which consists of inquiry content dimension, inquiry process dimension and inquiry context dimension and the results are as follows;1. In the analysis of the contents in the middle school science textbooks(chemistry part), the average number of total pages was 197.6. The illustration and picture were contained 0.66 in number per a page, and the average number of further readings was 5.8.2. In the analysis of the inquiry content dimension of inquiry activities, the total number of themes in five kinds of textbooks was 222. And the number of imquiry activities in five kinds of textbooks was siverse : A textbook had 51, B texbook 49, C textbook 37 and E textbook 35.3. For the analysis of inquiry process dimension. it follows in the order of 'interpreing data and formulating generalizations (42.4%)','observation and measuring (38.1%)','seeing a problem and seeking ways to solve it (7.8%)' and 'building, testing and revising the theoretical model(11.7%)'.4. As for the analysis of the inquiry context dimension, the scientific context occupied 94.2%, the individual context 0.4%, the social context 2.7% and the technical context 2.7%. It shows that the proportion of STS(Science-Technology-Society) related contents in inquiry activities was only 5.8%.

  • PDF

The Relationship Between Bone Mineral Density and Adipose Tissue of Postmenopausal Women (폐경 후 여성의 골밀도 수치와 지방조직과의 연관성)

  • Kim, Sun-Hwa;Kim, Jung-Hoon;Im, In-Chul
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.219-228
    • /
    • 2017
  • Postmenopausal women are at increased risk for osteoporosis and obesity due to changes in hormones. The relationship between osteoporosis and body weight is known, and its relation with body fat mass is discussed. The purpose of this study was to evaluate the bone mineral density(BMD) changes of epicardial adipose tissue(EAT) and abdominal subcutaneous fat. The subjects of this study were 160 postmenopausal women who underwent BMD and echocardiography. The thickness of the epicardial adipose tissue was measured in three sections and the BMD were meassured according to the diagnostic criteria. The results of this study that age increase the risk of osteoporosis increases, and as the weight and BMI decrease, the risk of osteoporosis increases(p<0.05). The relationship between changes in bone mineral density and adipose tissue in postmenopausal women, increased epicardial adipose tissue was negatively correlated with the bone mineral density(p<0.05). conversely, increased abdominal subcutaneous fat thickness was positively correlated with bone mineral density(p<0.05). In other words, the effect of bone mineral density on the location of adipose tissue was different. If Echocardiography is used to periodically examine changes in the thickness of the epicardial adipose tissue, it may be prevented before proceeding to osteoporosis.

무상증자 실시기업의 장기성과에 관한 연구

  • Kim, Byeong-Gi
    • The Korean Journal of Financial Studies
    • /
    • v.6 no.1
    • /
    • pp.23-45
    • /
    • 2000
  • 기존연구에 의하면 무상증자의 공시는 공시기간 중 정(+)의 가격효과를 초래하는 것으로 나타나고 있다. 무상증자에 대한 이러한 시장의 호의적인 반응을 설명하기 위해 여러 가설이 제기되어 왔으며, 그 중 무상증자는 좋은 내부정보를 외부에 신빙성 있게 전달하는 신호기제가 될 수 있다는 신호가설이 특히 지지를 받고 있다. 그런데 짧은 공시기간 중의 정(+)의 주가반응만을 보고 신호가설이 지지된다고 단정짓는데는 무리가 있다. 본 연구에서는 과연 신호가설이 주장하는 것처럼 무상증자가 사업기회의 확대, 미래현금흐름의 증대, 추후 차입여력의 증대를 가져오는가를 더 면밀히 검증하기 위하여 무상증자 실시기업의 장기성과를 조사하였다. 본 연구의 특징은 (1)공시기간 이후의 1년 이내의 기간에 중점을 둔 대부분의 기존연구와 달리 증자 후 36개월간의 장기성과를 측정하였으며, (2)주가수익률 자료와 회계자료를 동시에 이용하여 장기성과를 조사하였고, (3)장기 초과수익률 측정과 검증에 있어 통계적 오류가 있는 누적초과수익률(CAR)을 보완하기 위해 매입보유초과수익률(BHAR)을 사용했으며, 이를 위해 엄격한 기준을 적용하여 표본기업과 비교기업을 선정하였다는 데 있다. 실증분석 결과 신호가설을 지지하는 증거는 발견하지 못하였으며 오히려 무상증자 실시기업이 시장평균 또는 비교기업인 비증자기업에 비해 장기적으로 주가수익률 및 영업성과에 있어 저성과를 보이는 증거를 상당 수 발견하였다. 구체적으로 동일가중평균수익률로 조정한 보유기간 초과수익률의 경우 증자 후 1개월에서 24개윌까지의 BHAR이 5% 미만 수준에서 부(-)의 값을 보였으며, 비모수통계치를 사용할 경우 $1{\sim}36$개월까지의 전기간에서 유의한 부(-)의 저성과를 보이고 있다. 또한 영업성과면에서도 증자기업이 비증자기업에 비해 증자 후 수익성과 현금흐름이 저조하게 나타나고 있다.해 현물시장의 수익률, 변동성이 높은 것으로 나타났으나, 변경후에는 현물시장에 비해 선물시장의 수익률 변동성이 높은 것으로 나타났다. VAR 분석에 의하면 변경후가 변경전에 비하여 선물이 현물을 선도하는 시차가 다소 커진 것으로 나타나 현물시장과 선물시장이 동시에 가격제한폭 확대후에 비효율적으로 되었다는 의미로 판단된다.기간에서는 선물의 15분 선도효과와 현물의 1분 선도효과가 발견되어 선물의 선도효과가 지배적임을 발견하였다.적 일정하게 하는 소비행동을 목표로 삼고 소비와 투자에 대한 의사결정을 내리고 있음이 실증분석을 통하여 밝혀졌다. 투자자들은 무위험 자산과 위험성 자산을 동시에 고려하여 포트폴리오를 구성하는 투자활동을 행동에 옮기고 있다.서, Loser포트폴리오를 매수보유하는 반전거래전략이 Winner포트폴리오를 매수보유하는 계속거래전략보다 적합한 전략임을 알 수 있었다. 다섯째, Loser포트폴리오와 Winner포트폴리오를 각각 투자대상종목으로써 매수보유한 반전거래전략과 계속거래 전략에 대한 유용성을 비교검증한 Loser포트폴리오와 Winner포트폴리오 각각의 1개월 평균초과수익률에 의하면, 반전거래전략의 Loser포트폴리오가 계속거래전략의 Winner포트폴리오보다 약 5배정도의 높은 1개월 평균초과수익률을 실현하였고, 반전거래전략의 유용성을 충분히 발휘하기 위하여 장단기의 투자기간을 설정할 경우에 6개월에서 36개월로 이동함에 따라 6개월부터 24개월까지는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전략이고, 이 전략의 유용성은

  • PDF