Kim, Se-Young;Kim, Joo-Ho;Park, Hyo-Kuk;Cho, Jeong-Hee
Journal of radiological science and technology
/
v.36
no.1
/
pp.39-47
/
2013
For radiotherapy in rectal cancer patients treated with small bowel displacement device (SBDD) and belly board, We will suggest new indication of using SBDD depending on obesity index by analyzing correlation between obesity and irradiated small bowel volume. In this study, We reviewed 29 rectal cancer patients who received pelvic radiation therapy with belly board and SBDD from January to April in 2012. We only analyzed those patients treated with three-field technique (PA and both LAT) on 45 Gy (1.8 Gy/fx). We measured patients' height, weight, body mass index (BMI), waist-hip ratio (WHR) and divided BMI into two groups.(${\geq}23$:BMI=group1, <23:BMI=group2) We performed a statistical analysis to evaluate correlation between total volume of bladder($TV_{bladder}$), obesity index and high dose volume of small bowel (small bowel volume irradiated at 90% of prescribed dose, $HDV_{sb}$), low dose volume of small bowel (small bowel volume irradiated at 33% of prescribed dose, $LDV_{sb}$). The result shows, gender, WHR and status of pre operative or post operative do not greatly affect $HDV_{sb}$ and $LDV_{sb}$. Statistical result shows, there are significant correlation between $HDV_{sb}$ and BMI (p<0.04), $HDV_{sb}$ and $TV_{bladder}$ (p<0.01), $LDV_{sb}$ and $TV_{bladder}$ (p<0.01). BMI seems to correlate with $HDV_{sb}$ but does not with $LDV_{sb}$ (p>0.05). There are negative correlation between $HDV_{sb}$ and BMI, $TV_{bladder}$ and $HDV_{sb}$, $TV_{bladder}$ and $LDV_{sb}$. Especially, BMI group1 has more effective and negative correlation with $HDV_{sb}$ (p=0.027) than in BMI group2. In the case of BMI group 1, $TV_{bladder}$ has significant negative correlation with $HDV_{sb}$ and $LDV_{sb}$ (p<0.04). In conclusions, we confirmed that Using SBDD with belly board in BMI group1 could more effectively reduce irradiated small bowel volume in radiation therapy for rectal cancer. Therefore, We suggest using belly board with SBDD in order to reduce the small bowel toxicity in rectal radiotherapy, if patients' BMI is above 23.
The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.
The purpose of this study was to evaluate whether or not there was artifact when the upper limb could not be lifted to the top of the head during multi-detector computed tomography(MDCT) scans of the chest and abdomen. Contrast radiography of the human and chest phantom was performed with 128channal MDCT. Under the same conditions(120 kVp, 110 mAs, standard algorithm)both hands lifted up and put down each time in the human experiment. In the chest phantom experiment, the radiography was carried out when the upper limb phantom was adjusted at a certain distance(0, 3, 7 cm) from the chest phantom. Subsequently, the values of Noise, CT number, SNR, and CNR were measured in the field of concern. The noise value of fat, rib, and muscle increased when the arm was lifted in humans(0.79, 47.8, 27%). Furthermore, when the upper limb was lowered, the noise value of muscle and lung increased in the phantom(31.2, 9.4%). In addition, the noise value of the muscles and lung decreased by 5, 25.12% and 5.6, 15.35% as the upper limb moved about 0,3,7cm away from the chest. When the chest and abdominal radiography were performed, in the case of the presence of other parts outside the inspection area, the probability of artifact was minimal while the distance was more than 3cm away from the upper limb to the chest and abdomen.
Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.
Purpose We considered the correlation of Ejection Fraction (EF) which was analyzed by Multi Gated Blood Pool Scan (MUGA) and Echocardiography (ECHO) for the patients who were classified according to the condition of cardiac function. Materials and Methods We analyzed the patients (female 60) who were diagnosed with breast cancer and were examined by both MUGA and ECHO. The 30 patients (age: $58.27{\pm}13.48$) who were analyzed into less than 50% to 70% of EF were categorized as normal group and the other 30 patients (age: $53.70{\pm}8.45$) who were analyzed into less than 50% of EF were categorized as abnormal group. Statistical analysis with SPSS ver. 18 was applied. Results Each of the value of mean and standard deviation of normal group was $66.43{\pm}5.80$ (MUGA), $60.50{\pm}4.93$ (ECHO). There was a significant difference (p<0.001). Each of the value of mean and standard deviation of abnormal group was $41.93{\pm}7.58$ (MUGA), $41.70{\pm}11.49$ (ECHO). There was no significant difference (p>0.001). In the result, all 30 cases of normal group showed the same reading. 8 out of 30 cases in abnormal group showed inconsistency of the reading. Conclusion We could confirm the correlation of the EF in MUGA and ECHO statistically. There was difference between abnormal groups from the result of reading. If we are aware of the result according to the different cardiac function categorization, MUGA and ECHO can be used as even more accurate interchangeable test.
Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
The Korean Journal of Nuclear Medicine Technology
/
v.19
no.1
/
pp.30-36
/
2015
Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.
Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
The Korean Journal of Nuclear Medicine Technology
/
v.19
no.1
/
pp.37-43
/
2015
Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.
Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
The Korean Journal of Nuclear Medicine Technology
/
v.21
no.1
/
pp.60-64
/
2017
Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.
Journal of the Korean Society of Fisheries and Ocean Technology
/
v.34
no.1
/
pp.74-84
/
1998
A doubly resonant ultrasonic transducer has been designed as an attempt to increase the bandwidth of underwater transducers. The dual resonance conditions were accomplished by attaching a single acoustic matching layer on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and a prestress bolt. A modified Mason's model was used for the performance analysis and the design of transducers, and the constructed transducers were tested experimentally and numerically by changing the impedances and thicknesses of the head, tail and matching layers in the water tank. Two distinct resonance peaks in the transmitting voltage response(TVR) of a developed transducer were observed at 34.3 and 40.4 kHz, respectively, with the difference frequency of 6.1kHz and the center frequency of 37.2kHz. The values of TVR at these frequencies were 136.5 dB re $1\;\muPa/V$ at 34.3 kHz and 136.8 dB re $1\;\muPa/V$ at 40.4 kHz, respectively. Reasonable agreement between the experimental results and the numerical results was achieved. From this result, it is expected that the generation of the distinct resonances at any two desired frequencies can be achieved through the proper choice of the matching layer to provide the impedance transformation between the transducer and the medium.
Journal of the Korean Society of Fisheries and Ocean Technology
/
v.31
no.3
/
pp.228-239
/
1995
A model experiment on the pair midwater trawl net which is prevailing in Denmark is carried out to get the basic data available for Korean pair bottom trawlers. The model net was made in 1/30 scale considering the Tauti's Similarity law of fishing gear and the dimension of experimental tank. The vertical opening, horizontal opening, towing tension and net working depth of the model net were determined in the tank within the towing velocity 0.46~1.15m/sec, front weight 15.5~62.0g and distance between paired boats 5~8m(which correpond to 2~5k't in towing velocity, 70~280kg in weight and 150~240m in distance respectively in the prototype net). The results got from the model experiment can be converted into the full scale net as follows; 1. Vertical opening showed the largest value of 32m at the condition of 2k't in towing velocity, 280kg in front weight and 150m in the distance between paired boats, and the smallest value of 6m at the condition of 5k't in towing velocity, 70kg in front weight and 240m in the distance between paired boats. 2. Horizontal opening showed the largest value of 45m at the condition of 5k't in towing velocity, 70kg in front weight and 240m in the distance between paired boats, and the smallest value of 33m at the condition of 2k't in towing velocity, 280kg in front weight and 150m in the distance between paired boats. 3. Towing tension showed the largest value of 10, 000kg at the condition of 5k't in towing velocity, 280kg in front weight and 240m in the distance between paired boats, and the smallest value of 1, 600kg at the condition of 2k't in towing velocity, 70kg in front weight and 150m in the distance between paired boats. 4. Net working depth showed the largest value of 38m at the condition of 2k't in towing velocity, 280kg in front weight and 150m in the distance between paired boats, and the smallest value of 6m at the condition of 5k't in towing velocity, 70kg in front weight and 240m in the distance between paired boats. 5. Net opening area showed the largest value of 1, 100m super(2) at the condition of 2k't in towing velocity, 280kg in front weight and 180m in the distance between paired boats, and the smallest value of 250m super(2) at the condition of 5k't in towing velocity, 70kg in front weight and 240m in the distance between paired boats.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.