DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination (HVDC 슬립 온형 기중 종단접속함에 대한 열 영향 반영 DC 전계 특성 평가)

  • Kwon, Ik-Soo;Hwang, Jae-Sang;Koo, Jae-Hong;Sakamoto, Kuniaki;Lee, Bang-Wook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • A outdoor termination installed at the outdoor substation is required to connect undergroud cables and overhead transmission lines. The joint box for AC transmission system is already developed and widely used to interconnect overhead and undergroud systems. But the development of the joint box for DC transmission system was only introduced from China and Japan, but theire developemnt staus and core technologies were not fully reported. In order to implement HVDC systems connecting ovehead transmission lines and undergroud cables, a outdoor termination should be developed, but the detailed specifications and information of this device were not reported. It is estimated that the development of the joint box for DC environment has some technical obstacles including insulating materials, electric field mitigation, thermal temperature rise, and space charge accumuations. Among this, the most important one is the DC elctrical insualtion design. Therefore, in order to investigate the DC elctrical insualton design of outdoor termination, the design of AC slip-on type outdoor termination is reffered, and DC electric field analysis performed to verify the possiblity of application of AC joint box into DC joint box. Especially for DC electric field analysis, temperature rise of insualting materials of a joint box was considered, because the conductivity of materials could be changed due to temperature rise. Furthermore, DC electric field analysis considering transinet state, and polarity reversal state were also investigated to verify which state is the most severe condition for the DC joint box. From the simualtion resulsts, it was shown that the value and the position of maximum electric field was obtained comparing AC state, DC state without temperaure rise, and DC state with temperaure rise. And it was confimred that severe DC electric field was observed considing temperaure rise. Finally, in order to reduce DC eletric field intensifation, different configuration of the joint box was applied and it was not possible to obtain satisfactory results. It means that the slight change of configuration of AC joint box was not the suitable soluton for DC joint box. It is essential to establish novel DC insulaton design skills and method for DC joint box to commercialze this product in the near future.

Site Selection of Wildlife Passage for Leopard Cat in Urban Area using Space Syntax (공간구문론을 이용한 도시 내 삵 이동통로 적지선정)

  • Park, Jong-Jun;Woo, Dong-Geol;Oh, Dae-Hyun;Park, Chong-Hwa
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.92-99
    • /
    • 2012
  • Many wildlife habitats have been destroyed and fragmented during the rapid industrialization and urbanization process in Korea. It is essential to connect these fragmented habitats to reduce road-kill of many types of endangered urban wildlife. The site selection for wildlife passages must take into account the behavior of the wildlife species for safe crossing utilizing many artificial barriers in urban areas. This study attempted to identify potential wildlife passage sites for the endangered and protected leopard cats of Gangseo Ecological Park in Seoul, Korea. A space syntax analysis, an analytical technique to objectively evaluate the spatial configurations related to passage selection, found that the integration value represents the accessibility and connectivity of spaces. In this paper, this means that the bigger the integration value, the more frequently the leopard cat passes through. The leopard cats were captured and radio-tracked for 72 hours once a month from March to June of 2009. The ArcGIS and Animal Movement of Hawth Tools were used to analyze the home range and movement paths, and Axwoman 4.0 was used to analyze space syntax. The daily average movement distance was $2.099{\pm}1.08km$. During the survey period, the leopard cats crossed over an urban expressway more than 20 times, running the risk of road-kill. The range of global integration values was 0.458~1.834, while that of the local integration was 0.210~6.061. Five sites that met across the leopard cats' movement routes and roads were selected to measure the local and global integrate values. Among these sites, the higher the integration value, the higher the road-kill possibility. Thus, two of five sites with high global and local integration values were suggested as potential wildlife passage sites for the leopard cats. Now, three tunnel passages are under construction at the suggested sites for which local integration value was highest (LI=4.369). Further studies are scheduled to verify these potential sites as suitable wildlife passages.

A Study on the Economic Valuation of the Suncheon Bay Wetland according to the Logit Model (로짓모형에 따른 순천만습지의 경제적 가치평가)

  • Lee, Jeong;Kim, Sa-rang;Kweon, Dae-gon;Jung, Bom-bi;Song, Sung-hwan;Kim, Sun-hwa
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.10-27
    • /
    • 2017
  • Recently, the importance of recognizing the natural environment and the need for its conservation are increasing due to rapid urbanization. Suncheon Bay, designated as Scenic Site No. 41 and one of the World's Five Greatest Coastal Wetlands, is the only tideland among the tidal flats in Korea, which has salt marsh reserves. It has high conservation value from the ecological aspect. In addition to the Suncheon Bay National Garden, it provides various benefits not only to visitors but to local residents as well in terms of economics, environmental issues, and history and cultural aspects. Two million tourists visit the site annually, which has constantly highlighted the limits of ecological capacity. The valuation of the Suncheon Bay wetland is more important for the sustainability of the Suncheon Bay wetland than for its value as a tourism resource for the activation of the local economy. This study used the Logit model, which is commonly used among probabilistic choice models, to evaluate the economic value of Suncheon Bay wetland with the contingent valuation method(CVM). Applying the conservation value of the Suncheon Bay wetland to the benefit of KRW 8,200 for 1 person and 1 day, the benefit from exploration is KRW 2,050, the management and conservation value is KRW 3,034, and the heritage value is KRW 3,116. The results of this study are that benefit from the annual exploration of Suncheon Bay wetland was KRW 44.3 in billion, the management and conservation value was KRW 6.55 in billion, and the heritage value was KRW 6.73 in billion. When converted to the number of paying visitors per year, the conservation value is about KRW 177.1 billion. This study was conducted to evaluate the use and conservation aspects of the economic value of Suncheon Bay wetland. Based on the latent value of the Suncheon Bay wetland, it provides basic data about the efficient management and policy establishment of Suncheon Bay wetland. The study is significant in that the ecological sustainability of the Suncheon bay wetland and the value of non-marketable were evaluated based on the recognition of 'benefit through exploration', 'management and conservation value' and 'value of heritage'. It can be used as policy decision data on the integrated collection of the admission fee of the Suncheon Bay wetland and Suncheon Bay National Garden.

Analysis of Urban Heat Island (UHI) Alleviating Effect of Urban Parks and Green Space in Seoul Using Deep Neural Network (DNN) Model (심층신경망 모형을 이용한 서울시 도시공원 및 녹지공간의 열섬저감효과 분석)

  • Kim, Byeong-chan;Kang, Jae-woo;Park, Chan;Kim, Hyun-jin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.4
    • /
    • pp.19-28
    • /
    • 2020
  • The Urban Heat Island (UHI) Effect has intensified due to urbanization and heat management at the urban level is treated as an important issue. Green space improvement projects and environmental policies are being implemented as a way to alleviate Urban Heat Islands. Several studies have been conducted to analyze the correlation between urban green areas and heat with linear regression models. However, linear regression models have limitations explaining the correlation between heat and the multitude of variables as heat is a result of a combination of non-linear factors. This study evaluated the Heat Island alleviating effects in Seoul during the summer by using a deep neural network model methodology, which has strengths in areas where it is difficult to analyze data with existing statistical analysis methods due to variable factors and a large amount of data. Wide-area data was acquired using Landsat 8. Seoul was divided into a grid (30m × 30m) and the heat island reduction variables were enter in each grid space to create a data structure that is needed for the construction of a deep neural network using ArcGIS 10.7 and Python3.7 with Keras. This deep neural network was used to analyze the correlation between land surface temperature and the variables. We confirmed that the deep neural network model has high explanatory accuracy. It was found that the cooling effect by NDVI was the greatest, and cooling effects due to the park size and green space proximity were also shown. Previous studies showed that the cooling effects related to park size was 2℃-3℃, and the proximity effect was found to lower the temperature 0.3℃-2.3℃. There is a possibility of overestimation of the results of previous studies. The results of this study can provide objective information for the justification and more effective formation of new urban green areas to alleviate the Urban Heat Island phenomenon in the future.

Antioxidant and Angiotensin Converting Enzyme I Inhibitory Activities of Extracts from Mulberry (Cudrania tricuspidata) Fruit subjected to Different Drying Methods (건조방법에 따른 꾸지뽕열매 추출물의 항산화활성과 Angiotensin Converting Enzyme I 저해활성)

  • Youn, Kwang-Sup;Kim, Jae-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.10
    • /
    • pp.1388-1394
    • /
    • 2012
  • The physiological functionalities of 70% ethanol extracts (EE) from Cudrania tricuspidata fruit (ECFD, EE of C. tricuspidata subjected to freeze-drying; ECHD, EE of C. tricuspidata subjected to heat air drying; ECID, EE of C. tricuspidata subjected to infrared drying) were investigated. Yields of freeze-dried powders of ECFD, ECHD, and ECID were 51.50%, 53.91%, and 56.14%, respectively. Color $L^*$, $a^*$, $b^*$, and $H^{\circ}$ values of ECHD and ECID decreased. Dried ECHD and ECID had relatively higher contents of total polyphenolics and flavonoids than ECFD. Electron donating abilities at a concentration of 10 mg/mL (w/v) were in order of ECID (62.37%) >ECHD (80.17%)>ECFD (77.80%). Reducing powers ($OD_{700}$) of ECFD, ECHD, and ECID were 0.75, 1.70, and 1.89, respectively. Additionally, ABTS radical scavenging ability of ECID was the highest with a value of 62.37% at a concentration of 10 mg/mL (w/v). Nitrite scavenging activities of ECFD, ECHD, and ECID at a concentration of 10 mg/mL (w/v) were 28.76%, 30.69%, and 41.64%, respectively. SOD (superoxide dismutase)-like activities at 5 mg/mL (w/v) were in the order ECFD (891.93 mUnits)>ECHD (723.02 mUnits)>EFID (611.97 mUnits). Whereas ferrous ion chelating activity of ECFD (52.36%) and ECID (47.16%) was significantly higher than that of ECHD (30.04%). ACE inhibitory and xanthine oxidase (XO) inhibitory activities of ECHD and ECID at a concentration of 1 mg/mL (w/v) were higher than those of ECFD. In conclusion, we provided experimental evidence that extracts of pre-dried C. tricuspidata exhibit increased physiological functionalities. Further, infrared drying technique is the best method for enhancement of antioxidant activity of C. tricuspidata fruit.

Effect of Silicate Mineral Filtered Water and Silicate Mineral Additive on Growth Performance and Pork Quality (규산염 광물질로 정수된 급이수 및 사료내 규산엽광물질 첨가제의 급여가 돼지의 성장능력 및 돈육의 품질에 미치는 영향)

  • Kong, C.S.;Ju, W.S.;Kil, D.Y.;Lim, J.S.;Yun, M.S.;Kim, Y.Y.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.743-752
    • /
    • 2004
  • This experiment was conducted to investigate the effect of filtered water with silicate minerals on growth performance and pork quality. A total of 64 pigs were allotted at 37.95 kg body weight to 4 treatments in a randomized complete block(RCB) design. Each treatment had 4 replicates and treatments were I) Con(basaI diet). 2) Si-I(consumed silicate mineral filtered water and silicate mineral additive during 4 weeks before market weight), 3) Si-Il( consumed silicate mineral filtered water and silicate mineral additive during 8 weeks before market weight) and 4) Si-I1I(consumed silicate mineral filtered water and silicate mineral additive during 12 weeks before market weight). Silicate complex was added at 0.8% to basal diet. All pigs were allowed to feed and water ad libitum for 12 weeks. During last 4 weeks, average daily gain(ADG) in Si-Il and Si-III group was higher than that in Si-I group(P < 0.05). However overall experimental period, there were no significant differences in growth performance among all treatments. Acceptability of cooked pork at 7th day after slaughter in Si-lII group was higher than that in Con group(P < 0.05). The value of pH of fresh pork at 6 hours after slaughter was lower in Si-I1I group than that in Con group(P < 0.05). TBA values of fresh pork at 14th day after slaughter were lower in Si-II and Si-III groups than Con group(P < 0.05). These results demonstrated that pork quality could be improved when pigs consumed both silicate mineral and silicate mineral filtered water. However, growth performance was not improved by the consumption of silicate mineral filtered water and silicate mineral.

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Reactivity of Human Isolated Gastroepiploic Artery to Constrictor and Relaxant Agents (위대망동맥의 혈관 수축제 및 이완제에 대한 반응)

  • 이종태;이응배;박창률;김인겸;유완식;유영선
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.884-892
    • /
    • 1998
  • Background: The gastroepiploic artery is not only an alternative graft but also may be considered an important primary graft for coronary revascularization. However, the long-term patency of the gastroepiploic arterial graft is yet to be determined and the incidence of perioperative spasm and long-term patency of a coronary graft may be affected by the properties of the graft response to certain vasoactive substances. The reactivity of the gastroepiploic artery to vasoactive substances has not been studied extensively and the results of the studies are contradictory. Material and Method: This study was designed to test the reactivity of human gastroepiploic artery to four constrictors and four relaxants. The middle sections of the human gastroepiploic arteries were collected from the patients undergoing gastrectomy and the arterial rings with intact endothelium were suspended in organ baths for isometric tension recording. Result: Epinephrine, norepinephrine, and potassium chloride induced the maximum constriction to higher forces (7.0$\pm$1.1g, 6.6$\pm$0.9g, and 6.5$\pm$1.1g) than 5-hydroxytryptamine did (3.8$\pm$1.7g, p<0.05). Nitroprusside and histamine induced almost full relaxation in the gastroepiploic arteries preconstricted with norepinephrine. There was no significant difference between two relaxants regarding maximum relaxation force. Acetylcholine induced the maximum relaxation to weaker force when compared with nitroprusside and histamine (p<0.05), and isoproterenol was the weakest of the relaxants (p<0.05 compared with acetylcholine). Conclusion: The gastroepiploic artery has a strong capacity of endothelium-dependent relaxation which could have an important influence on long-term patency. The gastroepiploic artery exhibits a potent contractility to catecholamines and the enhanced contractility may facilitate vasospasm in the presence of high circulating levels of catecholamines. Nitroprusside, a potent relaxant in gastroepiploic artery, might be beneficial for the treatment of gastroepiploic arterial graft spasm. The gastroepiploic arterial graft with intact endothelium may respond weakly to beta-adrenoceptor agonist and 5-hydroxytryptamine.

  • PDF

Pulmonary Arterial Growth Pattern after Shunt Operation in Patients of Pulmonary Atresia with Ventricular Septal Defect Associated with Juxtaductal Stenosis (Juxtaductal stenosis가 동반된 PA/VSD환자에서 체폐단락술 부위에 따른 폐동맥 크기의 변화)

  • 이교준;박영환;최재영;조범구
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.861-866
    • /
    • 1998
  • Background: Pulmonary atresia (PA) with ventricular septal defect has various morphology of pulmonary arteries and pulmonary blood flow sources, so pulmonary arterial hypoplasia and arborization abnormality make this anomaly difficult to manage surgically. In cases associated with juxtaductal stenosis, we evaluated the change of the pulmonary arterial and juxtaductal stenotic site after shunt operations, and would like to find useful information in surgical planning and methodology of these patients. Material and Method: Among 59 cases diagnosed as PA with ventricular septal defect associated with juxtaductal stenosis, 29 cases who had cardiac catheterization before and after shunt operation were selected from July, 1991 to July, 1996. In 10 cases of right shunt operation(Group I) and 19 cases of left shunt operation (Group II), the diameters of the descending aorta, both pulmonary arteries, and the juxtaductal stenosis site were measured before and after the shunt operation. Result: In both Group I and II, the pre- and postoperative ratio of diameters of the ipsilateral pulmonary artery to the descending aorta was from 0.78${\pm}$0.31 units to 1.01${\pm}$0.26 units and from 0.67${\pm}$0.18 units to 0.84${\pm}$0.27 units respectively, showing a signigicant increase. The contralateral pulmonary artery index was increased from 0.92${\pm}$0.28 units to 1.05${\pm}$0.15 units and from 0.94${\pm}$0.27 units to 1.08${\pm}$0.37 units respectively, but could not be confirmed statistically. In both groups, the change of juxtaductal stenosis showed an aggravating tendency but of no statistical significance from 0.43${\pm}$0.27 units to 0.39${\pm}$0.25 units and from 0.32${\pm}$0.10 units to 0.30${\pm}$0.16 units respectively, and we experienced 2 total obstruction in Group II. Because the increased pulmonary blood flow by shunt operation has a favorable effect to the pulmonary arterial growth, the shunt operation is a recommended treatment in patients with hypoplastic pulmonary arteries. But in PA with ventricular septal defects, the change of juxtaductal stenosis is very important. In conclusion, the growth of ipsilateral (shunt site) pulmonary artery was promoted by shunt operation, but there is a tendency for the juxtaductal stenosis to be aggravated. And we experienced 2 total obstruction in Group II. Conclusion: Thus, in cases operated with shunt method, much careful postoperative follow up study including angiographic evaluation is needed, and after the shunt operation on the side of pulmonary artery associated with juxtaductal stenosis, early precise planning for total correction is recommended.

  • PDF

Changes in Centration of Contact Lenses on Cornea and Blink Rate Associated with Overusage of Disposable Lenses (일일 착용 렌즈의 착용기간 초과시 유발되는 렌즈의 중심 안정 위치 및 순목횟수 변화)

  • Park, Mijung;Yang, Jae Heon;Kim, Sun Mi;Park, Sang-Il;Park, Sang Hee;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Purpose: This study was assessed to investigate adverse effect induced by overuse of disposable soft contact lenses (CL). Methods: Three disposable lenses (etafilcon A, hilabilcon A, and nelfilcon A) were applied to 19 normal subjects free from any eye diseases for either a single day or variable periods by when subjects complained any discomforts. On the first and last days, localizations of lens' center on corneal surface and blink rates were recorded at every case. Results: Among CL wearers, 10.5% and 47.4% of total subjects quit wearing on the second day and third day, respectively. The case of stopping disposable lens wear was continuously increased with extended hour of lens application. On fourth day, 70.2% of CL wearers reported severe discomforts such as redness, dryness, irritation, pain and blurred vision. When subjects stopped CL wear, decentration of lens from the center of cornea was observed when it compared to the case of single usage of disposable CL. Also about 80% of total subjects showed increased blink rate when CL were worn for more than 2 days. These changes in lens centration and blink rate were consistantly shown regardless of lens types. Conclusions: Blurred vision and acute/chronic discomforts could occur to CL wearers by decentration of lens and increased blink rate when CL were overused more than 2 days even the numbers of two parameters measured in this study were variable by each subject or lens types. Therefore, consideration of individual characteristics and lens types is critical to prevent adverse effects may induced by overusage of disposable lens.

  • PDF