두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향 (Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography)

  • 김은혜;주영철;김한용;김동환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권6호
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

산업재 부품 구매자와 공급자의 신뢰와 몰입, 그리고 정보기술의 이용에 관한 연구 (A Study on Trust and Commitment between Buyer and Supplier of Industrial Parts, and Their Usage of Information Technology)

  • 김종훈;윤희택
    • 한국유통학회:학술대회논문집
    • /
    • 한국유통학회 2006년도 하계통합학술대회 발표논문집
    • /
    • pp.47-68
    • /
    • 2006
  • 본 연구는 산업재 부품 공급업체와 구매업체 사이의 신뢰와 몰입, 그리고 협력, 커뮤니케이션, 강제적 힘 등 행위적 관계변수들의 연관성을 규명하고, 아울러 정보기술의 사용이 관계의 질에 어떤 영향을 미치는지 규명하고자 하였다. 인천지역에 소재한 기계, 전자, 자동차 부품업체들을 조사대상으로 하여 216개의 분석 가능한 설문지를 확보하였다. 자료를 분석한 결과, 제시된 가설들이 모두 지지되었다. 첫째, 부품 공급업체의 구매업체에 대한 신뢰는 구매업체와의 관계 몰입을 이끄는 것으로 확인되었다. 둘째, 협력과 커뮤니케이션은 부품 공급업체의 구매업체에 대한 신뢰에 긍정적인 영향을 미치고, 강제적 힘은 신뢰에 부정적인 영향을 주는 것으로 입증되었다. 셋째, 부품 공급업체와 구매업체 간의 거래에서 사용되는 인터넷, E-Mail 등 정보기술은 관계의 질에 전반적으로 긍정적인 영향을 주는 것으로 검증되었다. 아울러 가설로 설정하지는 않았지만 협력과 커뮤니케이션은 서로 긍정적인 영향을 주고, 협력과 강제적 힘, 커뮤니케이션과 강제적 힘은 상호 부정적인 영향을 미치고 있음이 확인되었다. 본 연구는 산업재 부품 공급업체와 구매업체 사이의 관계, 그리고 정보기술이 관계의 질에 미치는 영향을 실증적으로 검토한 선험적인 시도라는 점에서 학문적인 의의를 찾을 수 있다. 또 연구 결과는 실무적으로도 부품 공급업체와 구매업체 간의 관계 강화에 많은 도움이 될 것으로 판단된다. 한편 연구대상이 업종별 및 지역적으로 편중되어 있고, 부품 공급업체 일방의 입장만을 고려하였다는 것 등 본 연구의 한계점들은 향후 연구들이 보완해야 할 사항들로 남겨지게 되었다. 측면에서 다양한 효과가 기대되며 앞으로도 이에 대한 내실 있는 운영을 위해서는 정부차원의 종합적인 지원 및 관리가 요구되는 시점으로 판단된다.pm3.42$, 저층수 $23.43\pm3.38$이었으며, 전반적으로 해역별 수질기준 I등급 내지는 II등급을 유지하고 있었고, 공간적으로는 외해측으로 갈수록 외해수와 혼합 확산되어 양호한 수질을 나타내었다. 장기적인 변동특성은 세그룹으로 구분되어진다.기 실험결과 용출용매로 증류수와 해수를 이용했을 때, 제강 슬래그에서 용출되는 납, 구리, 카드뮴, 수은의 용출 경향의 차이를 확인할 수 있었고 이에 따라서, 납, 구리, 카드뮴의 용출 유해성은 낮기 때문에 해양구조물로의 제강슬래그 유효이용은 적합할 것으로 판단되었다.im80%$로 계산되었다. 열형광선량계로 측정된 방사선량은 각각 1.8, 1.2, 0.8, 1.2, 0.8 (70 cm 거리) cGy로 측정되었으며, 환자의 복부 표면에서의 서베이메터를 이용한 측정량은 10.9 mR/h였다. 차폐구조물의 사용 시 전체 치료 동안에 태아선량은 약 1 cGy 정도로 평가되었다. 결론 : AAPM Report No.50의 자료에 따르면, 임산부의 방사선 치료 시 태아의 방사선 피폭선량은 5 cGy 이하일 경우에 방사선 피폭에 따른 태아의 위험이 거의 없는 것으로 제시되고 있다. 본원에서 차폐 구조물을 설치하였을 경우에 측정된 태아선량은 약 1 cGy로 측정되었고, 고안된 차폐구조물은 태아에 도달하는 방사선량을 감소시키기에 적합한 설계임이 입증되었다. 아니라 일반종합병원에서도 CTX-M형 ESBL 생성 E. coli

  • PDF

Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가 (Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT)

  • 손상준;박장필;김민정;유숙현
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.107-114
    • /
    • 2014
  • 목 적 : 두경부 치료계획 CT영상에서 dental implant로 인한 metal artifact 발생 시 O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands)를 적용할 수 있을지 여부를 평가하고자 한다. 대상 및 방법 : 모든 CT영상은 Brilliance Big Bore CT(Philips, Netherlands)에서 관전압 120kVp, 2mm 두께로 촬영하였으며, O-MAR를 이용하여 Metal artifact reduction 후 전산화치료계획장비(Eclipse ver 10.0.42, Varian, USA)로 원본영상과 비교, 분석하였다. O-MAR의 기본적인 성능 테스트를 위해 Metal artifact가 발생하지 않은 영상과 발생한 영상에서 O-MAR 적용시, HU 변화를 검증하기 위해 원통형 팬텀과 cerrobend 막대, 불균질 팬텀을 이용하여 실험하였다. 각각의 원본 영상과 O-MAR 적용 영상에서 관심영역 내 HU 변화를 측정하였다. 이를 바탕으로 본 연구의 주목적인 dental implant로 인한 metal artifact 발생 영상을 재현하기 위해 팬텀을 제작하여 사용하였고, 실제 임상 환자 영상에 O-MAR를 적용한 영상과 원본 영상 그리고 artifact 부분을 보정한 영상의 선량 분포를 SNC Patient(Sun Nuclear Co., USA)로 비교하였다. 결 과 : 두경부에서의 metal artifact를 재현한 원본 영상과 O-MAR 적용영상의 선량 분포를 비교한 결과 gamma passing rate 는 2 mm / 2% 기준으로 99.8%, 일치를 보였다. 실제 임상 환자 영상을 바탕으로 O-MAR 적용 전후 영상과 density corrected CT 영상에 동일한 조건으로 치료 계획을 수립하여 선량 분포를 비교한 결과는 98.5% 일치로 비교적 높은 gamma passing rate를 보였다. 전체적인 선량 분포 차이는 모두 2% 이내로 팬텀 실험과 실제 임상 환자 영상 실험에서 비슷한 결과로 나타났다. 하지만 선량 편차가 적더라도 국소적으로 집중되어 있는 것은 문제의 소지가 될 가능성이 있다. 화질 개선 면에서는 모든 실험에서 O-MAR 적용영상이 원본에 비해 개선됨을 알 수 있었으나, 두경부 metal artifact를 재현한 팬텀 영상 air cavity 내에서 최대 HU 값이 상승하는 경우가 생겼고, 환자 영상에서는 air cavity가 tissue로 잘못 보정되는 경우 또한 발견할 수 있었다. 결 론 : 업체에서 제시한 사용제한 사항인 피부 근처와 저밀도 영역이 공존하는 두경부에서 O-MAR의 사용 가능성을 확인해 본 결과, 원본의 왜곡과 보정이 동시에 일어났다. 심지어 팬텀 실험보다 더 심한 artifact가 생긴 환자의 경우 air cavity가 tissue로 잘못 보정되는 경우도 발생하였다. 결과적으로 아직까지는 O-MAR 알고리즘이 air cavity와 photon starvation artifact를 정확히 구분하지 못하는 것으로 보인다. 선량 측면에서의 영향은 임상에서 배제될 만큼 큰 차이를 보이지는 않았다. 임상에서 원본과 O-MAR 적용 영상을 비교하며 작업한다면 contouring, artifact 보정작업, DRR 화질 개선 등에 도움을 받을 수 있을 것으로 사료된다.

자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향 (Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode)

  • 정운찬;주영철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권2호
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

Dual Energy CT를 이용한 금속물질 인공물 감소방법 : Dual Energy와 MAR알고리즘의 임상적 응용 (A Study of the Metal Artifact Reduction using Dual Energy CT : Clinical Applications of Dual Energy and MAR Algorithm)

  • 박기석;최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.273-279
    • /
    • 2021
  • 전산화단층촬영 검사 시 인체 내에 삽입되어 있는 금속물질은 금속주위에 있는 인체조직이나 뼈와 큰 밀도차이가 있어 인공물을 발생시킨다. 이 실험을 통해 Single source Dual energy CT에서 Dual energy검사 및 MAR 알고리즘의 특성을 비교분석하여 임상적으로 적용방법에 대한 기초자료를 제시하려 한다. MAR 알고리즘을 적용하거나 Dual Energy를 이용하여 검사하였을 때 금속 인공물이 감소하였는데 MAR알고리즘을 적용한 영상은 세부적인 부분을 왜곡시키는 단점이 있다. Dual Energy로 검사한 영상은 MAR알고리즘을 적용한 영상보다 세부적인 부분까지 구현해 낼 수 있다는 장점이 있으나 재구성에 소요되는 시간이 길며 피폭선량이 MAR알고리즘을 적용한 영상보다 약 4배 가량 높았다. 수술 후 Follow up 및 금속물질의 위치를 파악하기 위해서는 MAR알고리즘을 적용하여 영상을 획득하는 것이 검사적 측면에서 유용하며 미세 병변 확인 및 수술계획을 세우거나 진단적인 측면에서 검사를 시행하였을 때는 Dual Energy로 검사하는 것이 더 유용하다.

방사선수술용 4뱅크 마이크로 다엽콜리메이터의 인수 검사 (Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery)

  • 정동혁;신교철;김정기;김수곤;문성록;이강규
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.43-50
    • /
    • 2009
  • 본 연구에서는 방사선수술용 4뱅크 마이크로다엽콜리메이터(micro-multileaf collimator: mMLC)인 Acculeaf (Direx, Isral)의 가동을 위하여 인수 검사를 실시하였다. mMLC의 제어에 필요한 기하학적 요소들을 결정하고 선량계산 모델에 의해 계산한 결과를 절대선량(cGy/100 MU)의 측면에서 측정과 비교하였다. 고정된 SSD (source to surface distance) 및 SCD(source to chamber distance) 조건에서 다양한 조사면과 깊이 5 cm와 10 cm에 대하여 계산값을 평가한 결과 6 MV와 15MV x-선에 대하여 대부분 1.0% 이내로 일치하였다. 반음영의 크기는 조사면에 의존하면서 6 MV에 대하여 0.29~0.43cm 범위 그리고 15 MV에 대하여 0.36~0.51 cm 범위로 평가되었다. 엽의 투과 및 누설의 측정결과 단층 엽들에 대하여 평균 6.6% (6 MV) 및 7.4% (15 MV) 그리고 겹층 엽들에 대하여 평균 약 0.5% (6 and 15 MV)로 나타났다. 인수검사를 통하여 mMLC의 선량적 특성을 확인할 수 있었으며 치료계획시스템의 오차범위를 근사적으로 평가할 수 있었다.

  • PDF

우리나라의 방사선작업종사자, 생활주변방사선, 환경방사선 등에 대한 융합적 관점의 안전 현황 고찰 (Statistical analysis of national examination for radiological technologists in convergence perspective)

  • 최경호;조정근
    • 한국융합학회논문지
    • /
    • 제9권5호
    • /
    • pp.85-90
    • /
    • 2018
  • 방사선 안전과 관련된 추가적인 정책을 수립 운영하기 위해서는 안전현황에 대한 기초적인 자료가 필요한데, 계량적인 관점에서 현황을 고찰한 연구는 많지 않다. 이에 본 연구에서는 방사선 안전과 관련된 영역 중, 방사선작업종사자, 생활 주변방사선 그리고 환경방사선 현황을 중심으로 다양한 통계적인 방법을 활용하여 계량적인 측면에서 고찰하였으며. 그 결과 다음을 알 수 있었다. 첫째, 2014년도 말 기준으로 9개 업종에 종사하는 방사선작업종사자 중 피폭선량이 가장 높은 업종은 NDT로서 다른 업종에 비하여 유의적으로 높게 나타났다. 둘째, 9개 업종의 방사선작업종사자에 대한 2010년 대비 2014년 피폭선량의 평균차이가 유의수준 5%에서 통계적으로 유의하지는 않은 것(p=0.221)으로 나타났다. 셋째, 전라북도 지역에 비하여 경기도 지역의 환경방사선량의 평균이 높은 것으로 나타났다. 본 연구의 결과는 향후 방사선작업종사자, 생활주변방사선, 환경방사선 관련 안전관리를 위한 기초자료로의 활용 및 방사선방호정책의 수립에 도움이 되기를 기대해 본다.

직업상 피폭에 따른 방사선 위험성 평가를 위한 다차원적 모델 (Multidimensional Model for Assessing Risks from Occupational Radiation Exposure of Workers)

  • 배유정;김병수;권다영;김용민
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.555-564
    • /
    • 2017
  • 직업상 피폭에 대한 현행 방사선 위험성 평가는 종사자의 피폭선량 평가 및 건강진단에 중점을 두고 있다. 이러한 개인 중심의 위험성 평가는 선량계 미착용 및 개개인의 기호로 인한 건강영향 문제 등 정확한 데이터 확보의 어려움으로 인한 오류의 가능성이 있다. 또한 평가의 기준이 되는 선량한도는 법적 최대 상한값으로 방사선 방호에 최적화된 값을 의미하지는 않는다. 이에 선원적, 환경적 및 인적 측면을 복합적으로 고려할 수 있고 방사선방호의 최적화를 이행할 수 있는 국가적 차원의 새로운 위험성 평가 모델이 요구되고 있다. 본 연구에서는 고용노동부의 위험성 평가에 기반하여 개인이 아닌 작업장 중심의 위험성 평가 모델을 연구하였다. 이를 위해 여러 분야의 위험성 추정 방법을 분석하여 방사선 분야에 적용하기 적합한 모델을 도출하고, 모델에 적용하기 위한 데이터 획득 방법 및 절차에 대해 기술하였다. 본 연구에서 도출한 작업장 중심의 다차원적 위험성 평가 모델은 위험성을 점수화하고 Rader Plot을 이용하여 표현함으로서 보다 정확한 방사선 위험성 평가를 가능하게 하며, 결론적으로 효율적인 종사자 관리, 선제적 종사자 보호 및 방사선 방호의 최적화 이행에 기여할 것으로 판단된다.

항공부문 우주방사선의 안전관리 적용을 위한 개선연구 (A Research on Improvement Measures for Safety Management of Aviation Cosmic Radiation)

  • 최성호;이진;김효중
    • 항공우주정책ㆍ법학회지
    • /
    • 제31권2호
    • /
    • pp.215-236
    • /
    • 2016
  • 본 논문은 항공부문 우주방사선 안전관리에 관한 적용 연구로써, 항공승무원 뿐만 아니라 항공교통이용자까지를 포괄한 연구로, 우리가 앞으로 심화할 것으로 예상되는 우주방사선 피폭에 대비해야 할 과제를 우선 제시하였다. 우리나라도 뒤늦게 우주방사선과 관련한 제도를 시행하고 있지만, 이에 대비한 강구책을 보다 실효성 있게 추진하기 위한 법률적인 개선뿐만 아니라 제도적인 측면을 보완 발전시키기 위한 다음과 같은 개선방안을 수행하여야 한다. 첫째, 국제기준에 부합한 선량한도의 적용이 필요하다. 이는 본 연구에서 언급한 우주방사선 선량한도 국제기준보다 우리나라 기준이 높거나 불합리하게 채택 적용하고 있기 때문에 국제권고를 초과하지 않는 범위로 재설정이 필요하다는 것이다. 둘째, 일반인에 대한 연간 유효 선량한도를 준수하기 위한 방법론이 필요하다. 왜냐하면 항공승무원만 명문화하고 일반인에 대해서는 배제하는 것은 국제방사선방호위원회에서 제시한 권고로, 우리나라는 "승무원에 대한 우주방사선 안전관리규정"에서도 일반인을 배제하여 제시하고 있다. 그러나 현재 항공법상에 항공교통이용자 보호기준이 있지만 항공권에 대한 피해예방만을 제시하고 있어서 국민건강을 위해할 수 있는 명분을 제공하고 있기 때문에 굳이 국제기준을 따르지 않는 개선이 필요하며, 이를 위해서는 법적으로나 제도적으로 시행될 수 있는 규제가 필요하다고 할 수 있다. 결론적으로 국제기준에 부합한 선량한도 설정과 모든 국민에게 우주방사선의 미소량이 항상 반응하고 있지만, 보다 많은 우주방사선이 공중 공간에 존재함에 따라 이의 누적량을 수치화한 개선방안이 법제화함으로써 우주방사선의 피폭으로부터 보호받을 수 있는 제도가 정착될 수 있을 것이다.

호흡동조방사선 치료 시 종양 치료의 정확도 평가 (Accuracy Evaluation of Tumor Therapy during Respiratory Gated Radiation Therapy)

  • 장은성;강수만;이철수;강세식
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.113-122
    • /
    • 2010
  • 목 적: 호흡동조방사선 치료 시 종양의 실제 움직임과 호흡추적장치로 측정한 피부 움직임의 차이를 자체 제작한 구동팬텀에서 가상의 종양을 이용하여 호흡과 유사하게 움직임에 따른 정적 상태, 동적 상태 및 호흡동조상태에서 표적 위치의 정확성의 측정치와 실측치를 평가하고 선량분포를 분석, 비교하고자 한다. 대상 및 방법: 호흡에 의해 움직이는 종양 측정을 위해 2차원적으로 움직이는 구동팬텀을 자체 제작하였다. 구동 팬톰의 움직임은 위. 아래 방향(SI) 각각 1.5 cm 왕복운동, 상 하 방향 2 cm으로 속도조절(1-5단계)이 되도록 하였다. 가로 4 cm, 세로 4 cm, 높이 0.5 cm의 아크릴 슬라이스에 직경 0.5 cm 종양을 납으로 표시하고, 위아래로 동일한 아크릴 슬라이스를 2장씩 쌓은 후 아크릴 슬라이스 세 번째와 네 번째 사이 Dmax 1.5 cm film을 삽입하였다. 가상의 타겟을 구동 팬텀 위에 위치시키고 6 MV X-선이 조사되는 정적인 상태, 호흡동조 및 동적인 상태에서 각각 5 Gy를 조사하였다. 구동팬텀 위에 표식자를 올린 후, 호흡추적장치를 이용하여 사전에 설정한 호흡시간의 변화에 따른 진폭과 위상변화를 분석하였다. 결 과: RPM respiratory gating system을 이용하여 호흡주기를 8단계로 나누어 각각을 12회씩 위상변화를 분석하여 평균과 표준편차를 구한결과 평균은 3.0 (1.5~1.5) sec에서 1.7 cm로 가장 크고, 3.0 (1.3~1.7) sec 5.0 (2.0~3.0) sec에서 0.2602 cm로 가장 크고 4.0 (2.0~2.0) sec에서 0.0866 cm로 가장 작았다. 또한 실측치에서 평균 및 표준편차를 구한 결과 t0에서 9.9 (6.6) mm $t_{10}$에서 10.6 mm (7.3), $t_{20}$ 16.5 mm (10.3), $t_{30}$ 10.2 mm (7.6)으로 나타났으며, 호기나 흡기 시간의 차이에 따른 규칙은 없고 대체로 균일한 평균과 표준편차의 분포를 나타내었다. 또한 정적 상태, 동적 상태 및 호흡동조상태에서 Gafchromic EBT film 의 방사선량을 분석한 결과, ICRU 62에서 권고한 90% 선량분포가 3 mm 이내에 포함되므로 정확성과 정도관리 측면에서 적합한 것으로 사료된다. 결 론: 구동팬톰을 이용하여 호흡움직임에 따른 정확성 및 선량분포차이를 Gafchromic film을 통하여 확인하였으며 결과를 바탕으로 호흡에 의해 변화가 생기는 장기에 대한 차이를 고려하여 치료계획을 한다면 종양과 정상조직에 적절한 선량계획을 세울 수 있어 치료효과 향상에 도움을 주게 될 것으로 생각한다.

  • PDF