A Study on the Optimum Design of Air-Conditioning Duct with Multiple Diffusers (다수의 취출구를 갖는 A/C덕트의 최적설계에 관한 연구)

  • 김민호;이대훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.98-106
    • /
    • 2002
  • The airflow characteristics of an air-conditioning duct with multiple diffusers were investigated through one-dimensional analysis, CFD simulation and experimental measurement. One-dimensional program based on Bernoulli's equation and minor loss equations was developed in order to evaluate the air distribution rate at each diffuser. In CFD simulation, three-dimensional flow characteristics inside air-conditioning duct were computed for incompressible viscous flow, adopting the RNG k-$\xi$turbulence model. Also, in an effort to equalize the discharge flow rate at each outlet, the optimization procedure has been performed to obtain the optimum diffuser area. In this process, square of difference between maximum discharge rate and minimum discharge rate is used as an object function. Diffuser area and discharge velocity are established as constraints. After optimization process, determined design variables are applied again in CFD simulation and experiment to validate the optimized result by one-dimensional program. Comparison with the experimental data of airflow rate distribution showed that the developed program seems to be acceptable and can be useful design tool for an automotive air-conditioning duct in an initial design stage.

A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Winter - Without Heat Loads from Occupancy - (대규모 실내경기장의 동계 온열환경 특성 실측조사 - 인체부하 미고려 조건 -)

  • Choi, Dong-Ho;Jeong, Seong-Jin;Seok, Ho-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.67-77
    • /
    • 2007
  • The purpose of this study is to provide fundamental heating design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with and without heating the space in winter. Heating loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF

A Study on the Indoor Thermal Environment of the Large Enclosure Without Cooling Loads from Occupancy in Summer (대공간내 인체발열 미고려시의 하계 온열환경 조사)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.3-8
    • /
    • 2008
  • The purpose of this study is to provide fundamental cooling design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with cooling the space in summer. Cooling loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF

A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Summer - Without Cooling Loads from Occupancy - (대규모 실내경기장의 하계 온열환경 특성 실측조사 - 인체부하 미고려 조건 -)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.6
    • /
    • pp.91-101
    • /
    • 2007
  • The purpose of this study is to provide fundamental cooling design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with and without cooling the space in summer. Colling loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF

Development of Large Diameter Hardfacing FCW for Life Extension of Hot Forging Die (열간단조 금형 수명연장을 위한 경화육성용접용 태경 FCW의 개발)

  • Kim, Sung-Ho;Jung, Yun-Ho;Baek, Seung-Hui;Jang, Jong-Hun;Park, Chul-Gyu;Woo, Hee-Chul;Jung, Byung-Ho;Cho, Sang-Myung
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.13-13
    • /
    • 2009
  • 현재 열간단조 금형을 제작함에 있어 육성용접을 실시하는 방법이 금형강 STD61, STD11 등으로 제작하는 방법에 비해 보수나 비용적인 측면에서 이점을 가지고 있기 때문에 점차적으로 증가하고 있는 추세이다. 열간단조 공정에서 금형은 $1000^{\circ}C$이상의 고온재료와 반복접촉하게 된다. 이때 이형제의 사용은 급속냉각 및 급속가열의 열피로를 가속시킨다. 또한, 금형은 반복충격에 의한 기계적 피로를 받게 된다. 이러한 금형의 사용환경을 고려한 FCW는 종래 고가의 $2.8{\sim}3.2{\Phi}$인 외국산 FCW를 사용하였으나 이를 대체한 $3.2{\Phi}$ 태경 FCW가 국내에서 개발되었다. 하지만 개발된 FCW를 사용하여 제작된 금형의 수명이 부족한 현상이 발생하였다. 이에 금형의 수명을 연장시킬 수 있는 내균열성 및 내열충격성을 확보한 태경 FCW의 개발과 개발된 FCW의 성능평가가 요구되었다. 특히 열간단조 금형에 있어서 중요한 내열충격성의 경우 가열과 냉각의 반복 Cycle에 의한 Thermal shock의 평가가 대부분이며 높은 Cycle로 인해 많은 시간이 걸리며, 또한 가열과 냉각을 오갈 수 있는 고가의 시험장치가 요구된다. 그러므로 개발된 FCW 육성용접부의 내균열성 및 내열충격성을 평가할 수 있는 방법에 대한 연구와 특히 내열충격성을 시간이 적게 걸리면서도 경제적으로 평가할 수 있는 방법에 대한 연구가 필요하다. 본 연구의 목적은 열간단조 금형 육성용접부의 내균열성 및 열충격특성을 평가할 수 있는 방법에 대한 검토와 특히 내열충격성에 대해 J.W.Kim등의 시험방법을 참고하여 시간이 적게 걸리면서 저 비용으로 열 충격특성을 평가할 수 있는 시험법을 고안하는 것이다. 이를 위한 방법으로 육성용접부의 내균열성을 평가하기 위한 상온 Bending을 실시하였고, 내열충격성을 평가하기 위한 염욕로를 이용하는 고온 Bending을 고안하여 실시하였다. 상온 Bending, 고온 Bending 모두 3점 굽힘시험을 적용하였다. 고온 Bending의 가열방법으로는 염욕로를 사용하여 시편이 대기중에서 약 $850^{\circ}C$의 온도가 될 수 있도록 하였다. 시편은 각각 열처리를 하여 요구 경도를 확보하였고, 이를 염욕로에서 5분간 가열 및 유지하여 취출 후 굽힘하중을 가하여 변위의 정도로 열충격을 평가하는 방법을 사용하였다. 상온 Bending은 극한변형량과 파단부 극한응력으로, 고온 Bending은 고온 극한변형량으로 평가를 하였고, 외국산 FCW를 사용한 육성용접부를 비교대상으로 하였다. 평가 결과 개발된 국산 $3.2{\Phi}$ 태경 FCW의 성능은 외국산 FCW와 유사하거나 우수한 것으로 평가되었고, 실제 금형을 제작하여 현장에 적용한 결과 금형의 수명이 연장된 것이 나타났다.

  • PDF

A Study on the Evaluation of Cabin Thermal Environment and Marine Fuels for Fuel Saving in Summer According to the Improvement of Air Conditioning System - The Case of Training Ship SAENURI - (공조시스템 개선에 따른 하절기 선실 온열환경 평가 및 유류절감에 관한 연구 - 실습선 새누리호를 중심으로 -)

  • Han, Seung-Hun;Kim, Hong-Ryel
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.6
    • /
    • pp.653-662
    • /
    • 2014
  • In this study, Mokpo national maritime university Training ship Centralizes Air Conditioning System was upgraded by installing onboard an Air-cooled Air conditioner. This resulted in the improvement of the performance and operation. This study compared refrigeration performance to former equipment and improving one. And through the actual measurement study about the cabin thermal environment, it will be used as basic data for marine air conditioning design and plan in the future. At same climate condition, when the Centralized Air Conditioning System and an improved air conditioning system operated, cabin temperature was at $24{\sim}28^{\circ}C$, humidity was 55~75 % as comfortable condition, Generator load measurement showed a saving of 48KW in the average load and 8 % in the full load factor. This also resulted in a saving of daily fuel oil consumption(FOC) at around 222 [${\ell}/day$] average. On the other hand, one cadet cabin(Cadet No.21) indicated a higher temperature due to heat transmission of engine room. It found us not to consider installing additional diffuser to reduce the heat transmission.