• Title/Summary/Keyword: 충전 시나리오

Search Result 53, Processing Time 0.033 seconds

Market Segmented Analysis of Electric Vehicle Purchasing Behavior in Seoul (서울시 전기차 구매행태에 대한 시장분할 분석)

  • HAHN, Jin-Seok;LEE, Jang-Ho
    • Journal of Korean Society of Transportation
    • /
    • v.36 no.2
    • /
    • pp.129-140
    • /
    • 2018
  • In this study, we analyzed the electric vehicle (EV) purchasing behavior with market segmentation in Seoul using the binary logit model. For the model estimation, the experimental design of SP survey generated 24 scenarios with purchase price, charging station availability, and driving range of EVs. The results of market segmentation analysis indicated that the owners of subcompact and compact size cars were primarily affected by the purchasing price while those of mid and full size cars were more sensitive to the charging station availability. By housing type, the charging station availability was the most important factor for the residents of apartment while the purchase price was the most important factor to choose the EVs. These results presented that the EV supply strategy of the automobile manufacturer should be diversified according to the marketing target and the expansion of the public charging infrastructure should be the top priority in the government policy.

Impact Evaluation of Plug-in Electric Vehicle Loading on Distribution Systems in North America (북미 배전계통에서의 플러그인 전기자동차에 대한 계통영향 평가)

  • Kook, Kyung-Soo;Maitra, Arindam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2236-2245
    • /
    • 2009
  • This paper proposes the process for evaluating the impact of charging the PHEV(Plug-In Hybrid Electric Vehicle) on the distribution systems, and analyzes the study results employing the actual systems as the PHEV is highly expected to increase in the automobile industries in North America in the near future. Since the charging load of the PHEV directly connected to the distribution systems would consume electric power much more than any other existing electric product of residential customers, the new modeling and process would be required to consider the PHEV in distribution systems planning. The EPRI(Electric Power Research Institute) is collaboratively conducting the impact study of PHEV on the distribution systems with power utilities in North America. This study models distribution systems and the charging load of the PHEV using OpenDSS software, and analyzes the impact of PHEV on the distribution systems by assuming various scenarios with different charging time and PHEV types.

Intent based Component Interaction Testing for Android Applications (안드로이드 어플리케이션의 인텐트 기반 컴포넌트 상호작용 테스팅 기법)

  • Baek, Tae-San;Lee, Woo Jin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.11a
    • /
    • pp.955-957
    • /
    • 2013
  • 안드로이드의 인텐트를 이용하여 주소록 어플리케이션에서 이메일 어플리케이션을 실행시킬 수 있다. 또한 어플리케이션 동작 중 배터리 부족 경고 또는 충전 케이블이 연결됨과 같은 시스템에서 브로드캐스트를 발생시킨다. 다른 어플리케이션의 컴포넌트를 실행시키고 시스템의 브로드캐스트를 처리하는 모든 것이 컴포넌트들 간의 상호작용이다. 컴포넌트들 간의 상호작용이 올바르게 이루어지지 않을 경우 다른 어플리케이션이 시작되거나, 보안상의 문제점 등이 발생할 수 있다. 본 논문에서는 위와 같은 문제점을 발견하기 위해 인텐트 기반의 안드로이드 상호작용 테스트를 위한 테스트 시나리오를 설계하는 기법에 대한 연구이다. 어플리케이션 내부의 컴포넌트 상호작용에 사용되는 명시적 인텐트와 다른 어플리케이션 또는 시스템의 컴포넌트들과의 상호작용에 사용되는 암시적 인텐트를 함께 고려하여 인텐트 목록을 생성하고 컴포넌트 상호작용 테스팅에 사용할 테스트 시나리오를 생성한다.

Analysis of Safety by Expansion of Hydrogen Charging Station Facilities (수소충전소 설비 증설에 따른 안전성 해석)

  • Park, Woo-Il;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.83-90
    • /
    • 2020
  • This study conducted a risk assessment using the HyKoRAM program created by international joint research. Risk assessment was conducted based on accident scenarios and worst-case scenarios that could occur in the facility, reflecting design specifications of major facilities and components such as compressors, storage tanks, and hydrogen pipes in the hydrogen charging station, and environmental conditions around the demonstration complex. By identifying potential risks of hydrogen charging stations, we are going to derive the worst leakage, fire, explosion, and accident scenarios that can occur in hydrogen storage tanks, treatment facilities, storage facilities, and analyze the possibility of accidents and the effects of damage on human bodies and surrounding facilities to review safety.

Optimal Supply Calculation of Electric Vehicle Slow Chargers Considering Charging Demand Based on Driving Distance (주행거리 기반 충전 수요를 고려한 전기자동차 완속 충전기 최적 공급량 산출)

  • Gimin Roh;Sujae Kim;Sangho Choo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.2
    • /
    • pp.142-156
    • /
    • 2024
  • The transition to electric vehicles is a crucial step toward achieving carbon neutrality in the transportation sector. Adequate charging infrastructure at residential locations is essential. In South Korea, the predominant form of housing is multifamily dwellings, necessitating the provision of public charging stations for numerous residents. Although the government mandates the availability of charging facilities and designated parking areas for electric vehicles, it bases the supply of charging stations solely on the number of parking spaces. Slow chargers, mainly 3.5kW charging outlets and 7kW slow chargers, are commonly used. While the former is advantageous for installation and use, its slower charging speed necessitates the coexistence of both types of chargers. This study presents an optimization model that allocates chargers capable of meeting charging demands based on daily driving distances. Furthermore, using the metaheuristic algorithm Tabu Search, this model satisfies the optimization requirements and minimizes the costs associated with charger supply and usage. To conduct a case study, data from personal travel surveys were used to estimate the driving distances, and a hypothetical charging scenario and environment were set up to determine the optimal supply of 22 units of 3.5kW charging outlets for the charging demands of 100 BEVs.

A Trends Analysis on Safety for CNG/HCNG Complex Fueling Station (CNG/HCNG 복합충전소의 안전에 관한 동향분석)

  • Lee, Seung-Hyun;Kang, Seung-Kyu;Sung, Jong-Gyu;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • In this research, the safety trends and technologies of HCNG, a mixture of hydrogen and natural gas, are analyzed. This is an attracting alternative fuels to meet the strengthened automotive exhaust gas emission standards. HCNG is very important opportunities and challenges in that it is available the existing CNG infrastructures, meets the strengthened emission standards, and the technical, social bridge of the coming era of hydrogen. It is essential for the commercialization of HCNG that hydrogen - compressed natural gas blended fuel for use in preparation of various safety considerations included accidents scenario, safety distance, hydrogen attack, ignition sources and fire detectors are examined. Risk assessments also are suggested as one of permission procedure for HCNG filling station.

Analysis on Flow Control Method for Simultaneous Fuel Filling of the Korea Space Launch Vehicle-II (한국형발사체 연료 동시충전을 위한 유량제어 방식에 대한 고찰)

  • Yeo, Inseok;Lee, Jaejun;An, Jaechel;Kang, Sunil
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.5-13
    • /
    • 2017
  • To lunch the Korea Space Launch Vehicle-II(KSLV-II), the second launch complex will be constructed on the Naro Space Center and Kerosene Filling System (KFS) will be also installed newly. KFS of KSLV-II launch complex system is being designed based on Naro Launch Complex. But this must supply fuel to fuel tanks of the vehicle with only a supply pump because KSLV-II is a 3-stage launch vehicle unlike Naro Launch Vehicle or Test Launch Vehicle (TLV). A sudden rise of pump output pressure is recognized during fuel filling scenario selection process. This occurs because return flow can not actively deal with a lot of flow change using flow control method of orifice type. To solve this problem, it is verified that fuel can be stably supplied by installation of accumulator and an appropriate adjustment of filling mode change sequence through flow analysis of various cases.

  • PDF

Analysis on Flow Control Method for Simultaneous Fuel Filling of the Korea Space Launch Vehicle-II (한국형발사체 연료 동시충전을 위한 유량제어 방식에 대한 고찰)

  • Yeo, Inseok;Lee, Jaejun;An, Jaechel;Kang, Sunil
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.132-140
    • /
    • 2018
  • To lunch the Korea Space Launch Vehicle-II(KSLV-II), a second launch complex will be built at the Naro Space Center, and a Kerosene Filling System (KFS) will be installed. KFS of KSLV-II launch complex system is being designed based on Naro Launch Complex. But this must supply fuel to fuel tanks of the vehicle with only a supply pump because KSLV-II is a 3-stage launch vehicle unlike Naro Launch Vehicle or Test Launch Vehicle (TLV). A sudden rise of pump output pressure is recognized during fuel filling scenario selection process. This occurs because return flow can not actively deal with much flow change using the orifice-type flow-control method. To solve this problem, it is verified that fuel can be stably supplied by installing an accumulator, designed for appropriate adjustment of filling-mode change sequence via flow analysis of various cases.

Quantitative Risk Assessment of Mobile LNG Filling Station (이동식 LNG 충전소 정량적 위험성 평가)

  • Jeon, Eun-Gyeong;Choi, Young-Joo;Kim, Pil-Jong;Yu, Chul-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.45-52
    • /
    • 2021
  • The government is converting the fuel for trucks, one of the causes of PM in Korea, form diesel to LNG. Mobile LNG station are being developed to solve the problems of insufficient charging infrastructure and facilitate the spread of LNG fuel. In this study, QRA was used th calculate the CA of the facility for a secure design prior to the development of the mobile LNG station and to predict the individual/societal risk the scenario. As a result, the danger of mobile LNG station was in ALARP.

A Study on the Minimum Safe Separation Distance from LPG Filling Station (액화석유가스 충전소의 안전거리에 관한 연구)

  • Jo Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.24-33
    • /
    • 1999
  • The minimum safe separation distances from LPG filling station was discussed in this work based on the accident data from 1987 to 1998 in south korea, the initial damage of accident, and standards of countries. The safety distances are adequate to reduce ignition probability by released gas and provide space for implementation of emergency response after ignition. Therefore, the distances are related to the distance to LFL(Lower Flammable Limit) and the length of jet fire to prevent accident escalation. The range of the distance was suggested in this work to make standard with considering economic, culture, and safe guards.

  • PDF