• Title/Summary/Keyword: 충전소

Search Result 216, Processing Time 0.025 seconds

Analysis of Hydrogen Sales Data at Hydrogen Charging Stations (수소 충전소의 수소 판매량 데이터 분석)

  • MINSU KIM;SUNGTAK JEON;TAEYOUNG JYUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.3
    • /
    • pp.246-255
    • /
    • 2023
  • Due to lack of hydrogen charging stations and hydrogen supply compared to the supply of hydrogen vehicles, social phenomena such as 2-hour queues and restrictions on charging capacity are occurring, which negatively affects the spread of hydrogen vehicles. In order to resolve these problems, it is essential to have a strategic operation of the hydrogen charging stations. To establish operational strategies, it is necessary to derive customer demand patterns and characteristics through the analysis of sales data. This study derived the demand patterns and characteristics of customers visiting hydrogen charging stations through data analysis from various perspectives, such as charging volume, charging speed, number of visits, and correlation with external factors, based on the hydrogen sales data of off-site hydrogen charging stations located in domestic residential areas.

EV charging station locations and a website to encourage carbon neutral activities (전기차 충전소 위치 및 탄소 중립 활동 장려 웹사이트)

  • Hyun-Sik Lee;Sung Jin Kim;Young Hyun Yoon;Jai Soon Baek
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.279-280
    • /
    • 2023
  • 최근 지구온난화로 인해 온도가 점점 상승하면서 홍수, 가뭄, 해수면 상승 등 이상 기후가 나타나고 있다. 이러한 상황을 막기 위해 기업과 국가 더 나아가 전 세계적으로 탄소 중립 활동을 실천하고 있다, 본 논문에서는 탄소 중립 활동에 도움을 주고자 전기차 충전소의 위치와 현재 상태를 실시간으로 확인할 수 있는 웹사이트를 서비스한다. 또한 사용자의 걷기 활동을 통해 이벤트를 진행하여 탄소 중립 활동을 장려하며, 다양한 교통정보 등을 서비스한다,

  • PDF

Illegal parking warning system in front of electric vehicle charger (전기차 충전기앞 불법 주차 경고 영상인식 시스템)

  • Yun, Tae-Jin;Lee, Tae-Hun;Lee, Yeong-Hoon;Jeong, Yong-Ju;Kim, Jae-Yoon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.443-444
    • /
    • 2019
  • 본 논문에서는 라즈베리파이(Raspberry Pi)와 실시간 객체 감지 기술인 YOLO를 이용한 전기차충전기앞불법주차 경고 영상인식 시스템을 제안한다. 최근 전기 자동차의 사용과 더불어 충전 인프라는 점점 늘어나는 중이지만, 여전히 전기차 충전기는 많지 않은 것이 현실이다. 전국 1,000여 곳이 넘는 전기차 충전소에 대해 법령으로 인한 규제를 시행 중임에도 불구하고 불법주차를 하는 일반차 오너들은 여전히 많다. 이로 인해 전기차 오너들은 충전에 많은 불편함이 있다. 이 시스템은 전기 자동차의 번호판을 인식하여 실시간 객체 감지 딥러닝 기법인 YOLO를 이용해 전기 자동차의 번호판에 특정 부분을 인식하고 특정 부분이 없는 일반 자동차가 전기차 충전기 앞 불법 주차를 하게 되면 부저와 LED경고를 통해 주차된 일반 차량에게 경고를 하여, 불법 주차자와 더불어 주변을 지나가는 행인들에게도 전기차 앞 불법 주차에 대해 각인을 시켜줄 수 있는 시스템이다.

  • PDF

A Study on the Quantitative Measurement of Oil Carry-over in Natural Gas Vehicle fueling Station Using A Gravimetric Method (무게측정법을 이용한 천연가스 자동차 충전소 오일전이 정량 분석에 대한 연구)

  • Hwang, Sung-Soo;Oh, Jun-Seok;Kim, Ki-Dong;Oh, Young-Sam;Choi, Kyung-Sik;Kim, Hack-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The core of the CNG fueling station is the compressor and most of CNG compressors in Korea require lubrication. Lubrication oil of CNG compressor that can be transferred into the pressure regulators and the engines of fueling system can cause a negative effect on NGV(Nature Gas Vehicle) performance during refueling due to oil Carry-over. In order to avoid the problem, it is necessary to enhance the quality of the compressed natural gas by measuring quantitatively the amount of the transferred oil. In this research, a sampling device and sampling tube were developed, which can be used with a gravimetric method of detection to measure CNG oil Carry-over. In addition, CNG samples were taken at 6 pre-selected CNG fueling stations and analysed for their trace oil Carry-over. The measured total oil Carry-over ranged from 2.569 to 6.509 ppm. This test measurements were compared with those of previous studies to verify the results.

Consequence Analysis of Hydrogen Filling Stations based on Cascade Compressing Systems (케스케이드 방식 압축시스템 기반의 수소충전소에 대한 정성적 위험성평가)

  • Ahn, Byeong-Jun;Rhim, Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.2
    • /
    • pp.13-21
    • /
    • 2021
  • Because of the recent expansion of hydrogen vehicle supply, the installation of hydrogen filling station is expected to gradually expand. This study attempts to predict the damage scale and propose a safer design form based on the scenario that assumes the worst case of a hydrogen station. A Flacs solver using computational fluid dynamics (CFD) was used to predict the damage scale, and the accuracy was verified by comparing it with the experimental results of previous researchers. The damage scale prediction was conducted for hydrogen leakage and explosion, and the prediction target was the KR model based on the measured values. And as a comparative review model, a roofless model was selected without a ceiling. As a result of analyzing the two models, it was possible to confirm the accumulation and retention of hydrogen gas up to 60 vol% or more in the KR model, whereas in the case of the Roofless model, the phenomenon of discharge and diffusion to the outside of the charging station by riding the wall after leakage. I was able to check. In conclusion, it was reviewed that the type of hydrogen charging station without ceiling is more advantageous for safety than the hydrogen filling station model.

전기안전사고사례 - 선박 정비작업 중 이동용 전선 손상으로 인한 감전 사망

  • Ryu, Bo-Hyeok
    • Electric Engineers Magazine
    • /
    • s.374
    • /
    • pp.38-39
    • /
    • 2013
  • 2013. 09. 13(금) 20시 35분경, 부산시 영도구에 소재한 ${\bigcirc}{\bigcirc}$조선소 협력업체에서 선박(오션에이스) 선미 좌현하부의 구멍 난 부위를 보수하는 작업 중 보조 작업자(남, 56세)가 피복이 손상된 이동용 전선 충전부에 접촉되어 감전 사망한 재해임.

  • PDF

The Component and Compositional Analysis of Trace Materials in LPG (LPG 잔류물질의 성분 및 조성 분석)

  • Kim, Yeong-Gu
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.317-323
    • /
    • 2002
  • The composition of trace materials in domestic circulated LPG are determined. The sampling points are two cylinders of LPG cylinder re-inspection center, six vaporizer of LPG-supplying group facilities, and the compressed oil from one LPG station. In the trace materials from cylinder of LPG cylinder-reinspection center, alkene and diene derivative (No. of carbon ${\leq}9),$ aromatic compounds, and tarry chemicals(No. of carbon ${\geq}10)$ are 1.5~39.9%, 0.7%, 57.8~96.0%, respectively. While in the trace materials from LPG-supplying group facilities and in the oil from LPG station, tarry chemicals(No. of carbon>10) exceed 96.6%. Nine samples are classified into three clusters. One cluster is the sample of SE company cylinder-reinspection center(Euclidian distance between S company LPG cylinder-reinspection center and SE company cylinder-reinspection center=2.11), the other is the sample of SE company LPG cylinder-reinspection center(Euclidian distance between from samples of LPG-supplying group facilities including compressed oil from LPG station=0.110) the third is the samples of LPG-supplying group facilities(Euclidian distances among them<0.075). The compositions of samples from LPG-supplying group facilities are similar to those of oil from LPG station. Furthermore densities of samples from LPG-supplying group facilities and compressed oil in LPG station are 0.873, 0.873 [0.00798 (99% confidence limits) respectively. It was presumed that tarry chemicals had been leached from the compressed oil of LPG supplying facilities.

A Study on Quantitative Risk Presentation of LNG Station (LNG충전시설의 위험도 표현에 관한 연구)

  • Ko, Jae-Wook;Yoo, Jin-Hwan;Kim, Bum-Su;Lee, Heon-Seok;Kim, Min-Seop
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • There are lots of energy facilities using gas(storage facility, compressed gas pipe, station, tank lorry) on the domestic. These major gas facilities cause major accidents associated with fire, explosion, toxic and etc. With the increased interest in reducing air pollution, supply of natural gas for gas vehicles is increasing. Thus, the number of establishments of LNG (Liquefied Natural Gas) and CNG(Compressed Natural Gas) stations is increasing as well. However, due to major gas accidents such as the fire and explosion accident of a Buchen LPG (Liquefied Petroleum Gas) station, it is difficult to establish a new station. In this research, we present quantitative risk assessment for LCNG;LNG multi-station and compare it result against individual risk criteria of HSE.

  • PDF

A Study on the Improvement of Hydrogen Tank Fueling Performance Using MC Methods (MC 기법을 이용한 수소 탱크 충전 성능 향상에 관한 연구)

  • JIAH CHOI;SANGWON JI;JISEONG JANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.447-455
    • /
    • 2023
  • SAE J2601, hydrogen fueling protocols, proposes two charging methods. The first is the table-based fueling protocol, and the second is the MC formula-based fueling protocol. Among them, MC formula-based fueling protocol calculates and supplies the target pressure and pressure ramp rate (PRR) using the pre-cooling temperature of the hydrogen and the physical parameters of the tank in the vehicle. The coefficient of the MC formula for deriving MC varies depending on the physical parameters of the tank in the vehicle. However, most studies use the MC coefficient derived from SAE J2601 as it is, despite the difference in the physical parameters of the tank applied to the study and the tank used to derive the MC coefficient from SAE J2601. In this study, the MC coefficient was derived by applying the hydrogen tank currently used, and the difference with the fueling performance using the MC coefficient proposed in SAE J2601 was verified. In addition, the difference was confirmed by comparing and analyzing the fueling performance of the table-based method currently used in hydrogen fueling stations and the MC formula-based method using MC coefficient derived in this study.

Development of Tie-Bar Installation Method for Concrete Pavement Widening (콘크리트포장 확장부 타이바 설치방법의 개발)

  • Hwang In-Kyu;Yang Sung-Chul;Jeong Jin-Hoon;Yoo Tae-Seok
    • International Journal of Highway Engineering
    • /
    • v.8 no.1 s.27
    • /
    • pp.33-43
    • /
    • 2006
  • Pull-out strength of tie-bin used in pavement construction is not an issue because those are embedded in newly placed concrete slabs. However, sufficient pull-out strength should be secured in widening constructions because, in case, the tie-bars are inserted into drilled holes of the existing slabs with liquid filler. Insufficient pull-out strength will result in lowered load transfer efficiency between adjacent slabs in addition to poor serviceability and durability due to joint widening. The pull-out strength of the tie-bars installed by current method is evaluated and improved methods are proposed. The field pull-out strength obtained by the current method was only 42.7% of required strength. Its first counterproposal is using to insert the liquid filler into drilled holes and stoppers to prevent it from flowing out of the holes. However, this method was not judged to secure desired level of quality control. The second counterproposal which substitutes the existing type of the tie-bars by SL anchor bolts was judged to secure sufficient pull out-strength in addition to the quality control and constructibility.

  • PDF