• Title/Summary/Keyword: 충전법

Search Result 429, Processing Time 0.031 seconds

A Study on the Model Test for Pneumatic Mine-Filling (공압식 갱내충전을 위한 모형실험 연구)

  • Yang, In-Jae;Shin, Dong-Choon;Yoon, Byung-Sik;Mok, Jin-Ho;Kim, Hak-Sung;Lee, Sang-Eun
    • Tunnel and Underground Space
    • /
    • v.24 no.6
    • /
    • pp.449-463
    • /
    • 2014
  • There are many case studies and application cases in abandoned mines for hydraulic filling method filled by slurry or paste form, but research on the pneumatic filling is not applied in Korea. The damage of steel pipe is occurred by wear due to the flow of filling material in the bent area of steel pipe in traditional pneumatic filling method. In this study, the new pneumatic filling method was developed using a newly devised improved nozzle to improve the above problem. The model test for mine filling was performed in the laboratory for the simulated accessible or inaccessible mine cavities, and the filling efficiency by the results obtained from the test was calculated. The filling efficiency was analyzed from the variation of outlet angle, feed rate and grain size of sand in model test of simulated accessible mine cavity. The superiority of improved pneumatic filling method was proved through the analysis of filling efficiency by the results obtained from each model tests of gravitational, traditional, and improved filling method in simulated inaccessible mine cavity.

THE CANAL SEALING EFFECT OF WARM LATERAL CONDENSATION OF GUTTA-PERCHA (가온 측방가압 근관충전법의 폐쇄효과)

  • Kim, Yong-Duk;Cho, Kyeu-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.429-446
    • /
    • 1994
  • The purpose of this study was to evaluate the sealing effect of warm lateral condensation technique by Endotec spreader, comparing with other canal filling techniques. One hundred and forty extracted human teeth with single canal were instrumented and randomly divided into four groups according to canal filling techniques including lateral condensation with sealer, warm lateral condensation with sealer, warm lateral condensation without sealer, and injection-molded thermoplasticized gutta-percha without sealer. Obturated canals were exposed to 2 % methylene blue solution at $37^{\circ}C$ for 24 hours and measurement of the degree of microleakage was done linearly and volumetrically with stereozoom microscope and UV-spectrophotometer respectively. The results were as follows ; When sealer was used, the canals obturated by warm lateral condensation showed less leakage linearly and volumetrically than the canals obturated by standard lateral condensation with no statistically significant difference. The obturated canals by warm lateral condensation with sealer showed less leakage linearly and volumetrically than the canals obturated by warm lateral condensation without sealer and by injection-molded thermoplasticized gutta-percha without sealer with statistical significance (p<0.05). No statistical difference revealed that the group filled with the use of the Endotec had significantly less leakage than any of the other groups. There was a significant correlation between the linear measurement and volumetric measurement(r=0.4459, p<0.05).

  • PDF

Comparative study on the apical sealing ability according to the obturation techniques (근관충전방법에 따른 치근단부 폐쇄능에 대한 비교연구)

  • Hwang, Ho-Keel;Park, Sun-Hee;Lee, Yeon-Jae
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.290-298
    • /
    • 2002
  • 3차원적으로 잘 충전된 근관은 치근단 누출과 재감염을 방지하며, 조직이 잘 치유될 수 있는 생물학적 환경을 제공해준다. 이 때문에 근관계의 완전한 충전은 근관치료의 중요한 목표 중의 하나이다. 본 연구의 목적은 4가지 방법으로 근관충전 후 디지털 방사선 사진을 촬영하여 근관충전의 질을 평가하고 투명표본을 제작하여 색소침투범위를 측정함으로써, 근관충전방법에 따른 치근단부 폐쇄능을 비교 평가하고자 하는 것이다. 직선형의 단근관을 갖는 80개의 전치를 선택하여 ProFile$^{\circledR}$ 니켈-티타늄 회전식 기구를 사용하여 근관을 성형한 후 무작위로 20개씩 4군으로 나누었다. 사용된 근관충전법은 다음과 같다:MicroSeal$^{\circledR}$(Group A), Thermafil$^{\circledR}$(Group B), Continuous wave 충전법(Group C), 측방가압충전법(Group D), 각 군에서 10개 치아는 Sealapex를, 나머지 10개 치아는 AH26$^{\circledR}$을 충전용 시멘트로 사용하였다. 근관충전이 끝난 치아는 충전의 질과 길이를 평가하기 위해, 근원심과 협설방향으로 디지털 방사선 사진을 이용하여 촬영하였다. 각 치아의 치근단부 2mm를 제외한 나머지 부위는 두겹의 nail varnish를 바르고, 2% methlylene blue용액에 48시간동안 침잠시켰다. 흐르는 물에 깨끗이 세척한 후, 투명치아를 만들었다. 선상의 색소침투를 관찰하고 치관측 최대깊이를 입체현미경하에서 40배율로 평가하여 다음과 같은 결과를 얻었다. 1. 충전방법에 따른 근단부 폐쇄효과를 비교시, 실험군 모두 비교적 양호한 근단부 폐쇄효과를 보였고 통계학적으로 유의성이 없었다. 2. 충전용 시멘트에 따른 근단부 폐쇄효과를 비교시, AH26$^{\circledR}$을 사용한 군에서 Sealapex를 사용한 군보다 더 적은 색소침 투를 나타냈다(p<0.05). MicroSeal$^{\circledR}$을 이용한 실험 1군내에서 AH26$^{\circledR}$을 사용하였을 때 미세누출이 더 적었고(p<0.05), 다른 군내에서는 통계학적으로 유의성이 없었다. 3. 근단부 충전상태에 따른 미세누출 비교시, 저충전, 과충전과 색소침투간에는 상관관계가 없었다. 4.충전방법에 따른 근단부 충전상태 평가시, Thermafil$^{\circledR}$을 이용한 실험 2군에서 과충전이 많이 나타났다(p<0.05). 이상의 결과로, 기존의 측방가압법 및 여러 열가소성 충전법이 유사한 근단부 폐쇄효과를 나타낸 바, 방법에 따른 술자의 숙련도, 충전시간, 재근관치료의 편이성 등을 고려하여 근관충전방법을 선택하는 것이 합리적일 것이라고 사료된다.

The Effectiveness of Obturating Techniques in Sealing Isthmuses (근관충전방법에 따른 근단부 isthmus의 폐쇄효과에 관한 비교연구)

  • Ho-Keel Hwang;Young-Guen Shin
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.6
    • /
    • pp.499-506
    • /
    • 2001
  • 불완전하게 충전되거나 충전이 되지않은 isthmus는 다근치에 있어서 근관치료의 높은 실패율을 나타낸다 따라서 본 연구의 목적은 isthmus를 갖는 근관을 골라 근관계의 기구조작을 시행하고 여러 가지 근관충전 방법을 이용하여 근관을 충전한 다음 근단부 형성시 적절한 파일의 크기와 치근단부의 밀폐효과를 각 부위별로 비교평가 해보고자 하는 것이다. Isthmus를 갖는 66개의 발거한 치아를 대상으로 기구조작을 통하여 근관확대를 완성하고 무작위로 각각 20개씩 3군으로 분류한 다음 아래와 같은 방법으로 근관을 충전하였다. : A군 측방가압충전법으로 충전한 군, B군 Continuous wave 충전법으로 충전한 군, C군 MicroSeal$^{TM}$을 이용하여 충전한 군. 나머지 6개의 치아는 3개씩 양성대조군과 음성대조군으로 정하였으며 기구조작 후 근관은 충전하지 않은 채로 두었다. 대조군을 제외한 모든 군은 각각 제조회사의 지시에 따라 근관충전한 후 각 시편의 치근단부 2mm를 제외하고 나머지 부위는 두겹의 nail polish를 발라주었으며 2% methylene blue용액에 침잠시켰다 일주일 후 꺼내어 흐르는 물에 깨끗이 세척한 다음 치근단 부위에서부터 1mm씩 잘라가면서 20배의 배율에서 염색액의 침투정도를 평가하였다. 염색액의 침투정도는 다음과 같이 평가되었다. A군과 B군에서는 많은 수의 시편에서 4mm 이상의 절단면에 염색액의 침투를 보인 반면 C군에서는 단지 3mm절단면에서 총 20개 중 3개의 시편에서 염색액의 침투를 보였을 뿐 그 이상의 절단면에서는 염색액의 침투를 보이지 않았다. 뿐만 아니라 isthmus를 갖는 제2형 근관계의 근단부 형성은 40번 크기보다는 큰 MAF가 요구되는 것으로 나타났다. 이러한 결과를 비추어볼 때 isthmus를 갖는 다근치에서 근관충전시 적어도 40번 이상의 MAF로 근단부 형성을 한 후, 열가소성 Continuous wave 충전법과 MicroSeal$^{TM}$을 이용한 근관충전법이 기존의 측방가압충전법 보다는 효과적인 것으로 나타났다.

  • PDF

SPECTROPHOTOMETRIC ANALYSIS ON THE SEALING EFFECT OF ULTRASONIC OBTURATION OF THE ROOT CANAL (초음파(超音波) 근관충진법(根管充眞法)의 폐쇄효과(閉鎖效果)에 관(關)한 분광광도계(分光光度界) 측정(測定))

  • Kim, Yang-Lag
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.46-57
    • /
    • 1990
  • The purpose of this study was to spectrophotometrically investigate the sealing effect of the ultrasonic canal obturation with softened gutta-percha utilizing an endosonic plugger by means of ultrasonic vibrations and heat. The 120 extracted human central and lateral incisors with single root were randomly selected, and the root canals were instrumented up to size #60 file by conventional method. The prepared canals were obtruated with gutta-percha by lateral condensation method, McSpadden technique and ultrasonic condensation method, with or without sealer. All specimens were immersed in 2% methylene blue in an incubator at $37^{\circ}C$ for 10 days. The teeth were then dissolved in 5ml of 60% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data statistically evaluated usint two-way ANOVA and Student's t-test. The results were as follows : No statistically significant difference in leakage was observed between the lateral condensation method and ultrasonic condensation method, with and without sealer. When sealer was used or not, McSpadden technique showed significantly greater leakage than lateral or ultrasonic condensation method. Statistical analysis of the data indicated that the canals obturated in conjunction with sealer demonstrated less dye leakage than the canals obturated without sealer(p<0.01), except McSpadden technique. The ultrasonic condensation method appeared comparable sealing ability to the lateral condensation method.

  • PDF

Research Trend of High-Efficiency Charging Method for Lithium Rechargeable Batteries (리튬이차전지의 고효율 충전법 연구 동향)

  • Kim, K.M.;Lee, Y.G.;Yang, Y.S.;Kim, J.
    • Electronics and Telecommunications Trends
    • /
    • v.25 no.5
    • /
    • pp.11-19
    • /
    • 2010
  • 유비쿼터스 시대의 모바일 전력원으로서 가장 유용한 리튬이차전지의 충전방식은 1991년 리튬이온전지의 상용화 이후 정전류-정전압 방식의 충전법이 고수되어 왔다. 그러나 압전, 열전 등 신재생에너지에 의한 에너지 하베스팅으로 생성되는 전력의 성질이 전압과 전류의 범위가 매우 다양하므로 효율적으로 저장할 수 있는 에너지 매니지먼트 체계가 필요하다. 이에 대한 기반연구로서 리튬이차전지의 고효율 충전을 위한 다양한 방식이 고려되어 왔으며, 본 동향분석서에서는 이러한 충전방식에 따라 리튬이차전지 내부 소재가 받는 영향과 여러 충전방식의 장단점을 분석하고, 최적 충전방식의 기준을 정리한다.

Control System Design of the LED Synchronous Lights with Solar Charging Method by Maximum Power Point Tracking (최대전력추종 태양광 충전법을 적용한 LED 동기점멸등 제어시스템 설계)

  • Son, Young-Dae;Huh, Seong-Min;Kim, Cherl-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.32-34
    • /
    • 2011
  • 본 논문은 최대전력추종 태양광 충전법을 적용한 LED 동기점멸등 제어시스템 설계 및 구현을 목표로 한다. 즉, 선박의 야간 안전항해를 돕기 위한 항로표지인 등부표에 장착되는 LED 동기점멸등의 구동제어 시스템, 최대전력추종 방식의 전류제어 벅 컨버터를 적용한 배터리 충전시스템의 설계 및 구현, 그리고 그 특성파악에 대해 중점적으로 다룬다. 시스템에 적용한 태양광 모듈의 모델링 및 MATLAB 시뮬레이션을 통해 추출한 태양전지 파라미터를 충전회로 시스템에 적용하여 최대전력추종 태양광 충전시스템을 설계하였다. 따라서, 본 논문에서는 원칩 마이크로컨트롤러를 사용하여 최대전력추종(MPPT) 태양광 충전제어시스템과 GPS활용 LED 동기점멸등 구동제어시스템을 구현하여, 그 특성파악을 통한 실시스템 적용가능성을 확인하였다.

  • PDF

Study on High-efficiency Hydraulic Filling Field Experiment for Subsidence Protection (지반침하 방지를 위한 고효율 수압식 충전 현장실험에 관한 연구)

  • Yang, In-Jae;Choi, Nam-Soo;Jeon, Chul-Soo;Lee, Sang-Eun;Shin, Dong-Choon
    • Tunnel and Underground Space
    • /
    • v.24 no.5
    • /
    • pp.373-385
    • /
    • 2014
  • Hydraulic filling methods are widely applied to suppress the land subsidence recently. But the research on high-efficiency hydraulic filling to protect the land subsidence is rare. In this study, field experiments to improve the efficiency of the hydraulic filling method are performed by changing the property, specification of the filling material and injection pipe. The filling amounts using vertical injection pipe, reducing tee (${\phi}100mm$) pipe, reducing tee (${\phi}80mm$) pipe and reducing tee (${\phi}50mm$) pipe showed 28.84 ton, 42.62 ton, 53.33 ton, and 63.33 ton respectively. The filling rates using reducing tee (${\phi}100mm$) pipe, reducing tee (${\phi}80mm$) pipe and reducing tee (${\phi}50mm$) pipe showed 47.8%, 84.9% and 119.6% respectively. Filling efficiency can be incresed by using reducing tee. This study shows that simply changing the type of injection pipe is expected to increase the hydraulic filling rate.

Effect of Retrograde Autologous Priming in Adult Cardiac Surgery for Minimizing Hemodilution and Transfusion Requirements (성인개심술에서 혈액희석 및 수혈을 최소화하기 위한 역행성 자가 혈액 충전법의 효과)

  • Kim Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.38 no.12 s.257
    • /
    • pp.821-827
    • /
    • 2005
  • Background: Hemodilution after priming of the cardiopulmonary bypass is known to increase the possibility of bleeding and homologous transfusion in adult cardiac surgery. We investigated the effects of retrograde autologous priming (RAP) to see whether it would decrease postoperative bleeding and homologous transfusion. Material and Method: We retrospectively reviewed 34 patients wpho underwent RAP and 46 patients who did not. Retrograde autologous priming consisted of arterial lire drainage, venous reservoir and oxygenator drainage and venous line drainage. We compared the amount of priming solution and RAP volume, perioperative hematocrit, postoperative bleeding and transfusion requirements in the two groups. Resuit: Mean withdrawal volume in RAP group was 613.5$\pm$160.6 mL and initial priming volume was 1381.9$\pm$37.2 mL. Hemoatocrits ($\%$) in RAP and control groups were 25.0$\pm$3.7 vs 20.9$\pm$3.6 (5 minutes after CPB), 25.9$\pm$3.7 vs 22.5$\pm$3.6 (30 minutes after CPB), 25.9$\pm$3.4 vs 23.8$\pm$2.8 (60 minutes after CPB), 31.9$\pm$3.9 vs 31.5$\pm$4.5 (postoperative 1 hour), 32.4$\pm$4.4 vs 32.1$\pm$4.5 (postoperative 6 hours), 33.4$\pm$5.0 vs 31.7$\pm$5.1 (postoperative 1 day)[repeated measures ANOVA, p < 0.05]. Chest tube drainages (mL) in the two groups were 357.2$\pm$177.1 vs 411.7$\pm$279.5 (postoperative 6 hours), 599.4$\pm$145.6 vs 678.8$\pm$256.4 (postoperative 24 hours)[t-test, p < 0.05]. Homologous transfusion was performed in 7 out of 34 patients in RAP group (20.6$\%$), and 16 out of 46 (34.8$\%$) in control group (p < 0.05). Conclusion: This study suggests that the effects of reducing the priming volume during cardiopulmonary bypass may result in lesser bleeding and homologous transfusion. Retrograde autologous priming would be used to reduce postoperative bleeding and chance of transfusion after adult cardiac surgery.

냉음극형 X-선 튜브의 제작을 위한 CNT 페이스트의 무기 충전제에 대한 연구

  • Kim, Jae-U;Gang, Jun-Tae;Jeong, Jin-U;Choe, Seong-Yeol;Choe, Jeong-Yong;An, Seung-Jun;Song, Yun-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.290.2-290.2
    • /
    • 2013
  • X-선 튜브는 의료 영상 및 치료, 산업용 제전 장치, 비파괴 X-선 영상 장치 등에서 사용되는데 기존의 열전자원을 이용한 X-선 튜브와는 달리, 냉음극형 X-선 튜브는 빠른 속도의 디지털 구동이 가능하며 전력 소비가 낮은 장점이 있다. 따라서, 최근 많은 연구자들에 의해서 냉음극형 X-선 튜브에 관한 연구가 활발하게 진행되고 있다. 냉음극형 X-선 튜브는 전계 방출을 이용한 전자원을 사용하며, 탄소나노튜브 (CNT), Si, 다양한 종류의 나노선 등이 대표적이다. 그 중에서 CNT는 높은 종횡비로 인해 전계 방출 특성이 우수하여 가장 대표적인 물질이다. CNT를 이용한 전자원을 제작하기 위해서는 직접 성장법, 전기영동법, 스크린 프린팅법, 디핑법 등 다양한 방법이 존재한다. 직접 성장법을 제외한 방법들은 모재료인 CNT와 용매, 금속재료들을 섞어 페이스트나 수용액의 상태를 제작하여야 한다. 이 때, 금속 재료는 기판과 CNT간의 접착 및 전자 전도 통로의 역할을 하는 무기 충전제이며 일반적으로 나노 혹은 수 마이크로미터 크기의 상태로 존재하는 것을 주로 사용한다. X-선 튜브 제작은 일반적으로 외벽을 유리 혹은 세라믹을 주로 사용하는데 아노드 전극 및 캐소드 전극 등과 결합하여 진공 밀봉된 형태가 되어야 한다. 브레이징 방법은 금속과 세라믹을 결합하는데 매우 유용한 방법이며, 그 중에서도 진공 브레이징 방법은 다량의 부품을 한 번에 결합시킬 수 있다. 하지만 진공 브레이징 공정의 온도는 약 $700{\sim}1,000^{\circ}C$이며 이는 금속 재료가 충분히 증발할 수 있는 온도가 된다. 본 발표에서는 고온 진공 상태에서의 무기 충전제의 증발에 대한 현상을 관찰하고 고온진공 상태에서 증발없이 무기 충전제로의 역할을 할 수 있도록 다양한 금속 및 합금에 대한 연구를 수행하였다. 또한, 이 연구를 통해 선택된 무기 충전제를 포함하여 CNT 페이스트를 볼밀링 방법을 이용하여 제작하였으며, 이를 이용한 CNT 에미터가 X-선 튜브의 전자원으로 사용될 수 있는지 확인하기 위해 전계 방출 실험을 함께 실시하였다. 제작된 CNT 에미터가 우수한 전계 방출 특성을 가지고 있음을 확인하였으며, 이는 본 연구를 통해 선택된 금속 및 합금 재료가 무기 충전제로의 역할을 잘 수행하고 있음을 보여준다.

  • PDF