• Title/Summary/Keyword: 충격 저감

Search Result 255, Processing Time 0.024 seconds

A Study on Relationship between Track Impact Factor and Track Support Stiffness of Turnout System on Urban Transit (도시철도 분기기 궤도구조의 궤도지지강성과 궤도충격계수의 상관관계에 관한 연구)

  • Choi, Jung-Youl;Park, Jong-Yoon;Lee, Kyu-Yong;Chung, Jee Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.461-466
    • /
    • 2020
  • In this study, the relationship between the track support stiffness and the track impact factor for a sleeper floating track and a turnout system with wood ties currently employed in Korean urban transit was assessed by performing field tests using actual vehicles running along the service lines. Field tests were performed on four track systems (i.e., sleeper floating track, and point, lead and crossing sections of turnout system). The theoretically designed track impact factor and track support stiffness were compared with the corresponding track impact factor and track support stiffness measured through field tests for the target tracks on the service line. The track impact factor for the service line appeared to increase with the deviation of track support stiffness according to vehicle driving direction; therefore, it was inferred that the deviation of track support stiffness between each track section directly affected the track impact factor.

A Study on the Actual Survey and Reduction of Plumbing Noise in Apartment Houses (공동주택 급배수 설비소음의 실태 및 저감방안에 관한 연구)

  • Kim, Heung-Sik;Ji, Yong-Kyoun;Yoon, Se-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.45-54
    • /
    • 1990
  • As the results of actual survey of indoor noise in apartment houses, it represents that plumbing noise and floor impact noise are most unsatisfactory factors to inhabitants. In this paper, the actual condition of plumbing noise in apartment houses was measured and the methods of plumbing noise reduction are suggested. For these suggestions, the actual survey of plumbing noise and the model test on structure-borne sound of water supply pipe and drain sound were carried out.

  • PDF

Experimental study on reduction of impulsive noise generating at exit of high-speed railway tunnel (고속철도 터널출구에서 발생하는 충격성 소음의 저감을 위한 실험적 연구)

  • Kim, Hui-Dong;Setoguchi, Toshiaki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2375-2385
    • /
    • 1996
  • As a compression wave is emitted from a duct, an impulsive wave generates and causes an impulsive noise that is at present a serious environmental noise pollution. In order to clarify the acoustic characteristics of the noise and to reduce their pressure levels, a series of model experiments were conducted on the impulsive waves emitted from an open end of a shock tube. The impulsive waves with various intensities were obtained by controlling the operation pressure ratio of the shock tube. Various kinds of silencers such as the exit boxes with baffle plates, were applied to the duct exit to reduce the impulsive noises. The effects of geometry of silencers and shock Mach number on the noise reduction were clarified. From the measurements of sound pressure level, it was found that installing the baffle plate into the exit box is effective in lowering the noise level at far fields, and that the recommendable geometries of silencer are L/D=1, H/D=1 and H/D=0.75.

Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad (바닥충격음 완충재의 동적특성과 소음저감 성능 비교)

  • Yang, Soo-Young;Lee, Dong-Hoon;Hong, Boung-Kuk;Song, Hwa-Young;Lee, Joo-Wone
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF

Analysis and Evaluation of Impact Sound Insulation of Concrete Floor Structures in Response to Characteristics of Heavy-weight Impact Sources (중량충격원에 따른 콘크리트 바닥판의 차음특성 분석 및 평가에 관한 연구)

  • Yoo, Seung-Yup;Yeon, Jun-Oh;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.10
    • /
    • pp.1062-1068
    • /
    • 2009
  • In this study, the impact force levels of bang machine and impact ball were measured, then the heavy-weight impact sounds generated by the bang machine and impact ball were investigated. It was found that the heavy-weight impact sources generated through modal excitation, and the impact force of the impact ball was similar to that of real impact source. The heavy-weight impact sounds were also measured in the real apartments with different slab thickness and floor structures. The results showed that the floor impact sound levels in terms of $L_{iFmax,AW}$, generated by impact ball sounds were reduced by using the resilient isolators. The frequency characteristics of heavy-weight impact sounds at 125 and 250 Hz were consistent with the characteristics of impact force spectrum. However, the difference between the impact sounds and the impact forces were found at 63 and 500 Hz due to the resonance of the floor structure and flanking noise, respectively.

A Study of Impact Reduction Characteristics of Hat-Shaped Stiffened Panel Under Hypervelocity Impact (초고속 충돌을 받는 모자형 보강 패널의 충격 저감 특성에 관한 연구)

  • Yang, Tae-Ho;Lee, Young-Shin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.7
    • /
    • pp.929-935
    • /
    • 2013
  • This paper presents the results of sizing optimization of ahat-shaped stiffener on a rectangular stiffened panel. The stiffened panel is subjected to impact loading by a projectile with a velocity of 1500-2500 m/s. To determine the size of the hat-shaped stiffener, sizing optimization was performed. The sizing optimization consists of three functions: objective, constraint, and design functions. The objective function is used to maximize the fundamental frequency of the stiffened panel. The constraint function is that the stiffener volume is less than 10% of the plate volume. The design function is the dimensions of the hat-shaped stiffener. By using the stiffened panel with the optimized hat-shaped stiffener, a hypervelocity impact was simulated, and the velocity and kinetic energy on the optimized stiffener was obtained. To evaluate the impact reduction on the stiffened panel, the velocity and kinetic energy of the projectile was normalized and compared.

Prediction of Heavy-Weight Floor Impact Sound in Multi-unit House using Finite Element Analysis (유한요소해석을 이용한 공동주택의 중량충격음 예측)

  • Mun, Dae-Ho;Lee, Sang-Hyun;Hwang, Jae-Seung;Baek, Gil-Ok;Park, Hong-Gun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.645-657
    • /
    • 2015
  • In this study floor impact noise and structure acceleration response of bare concrete slabs were predicted by using Finite Element Analysis(FEA). Prediction results were compared with experimental results to prove the accuracy of numerical model. Acoustic absorption were addressed by using panel impedance coefficients with frequency characteristics and structural modal damping of numerical model were applied by modal testing results and analysis of prediction and test results. By using frequency response function, the floor acceleration and acoustic pressure responses for various impact sources were calculated at the same time. In the FEA, the natural frequencies and the shapes of vibration and acoustic modes can be estimated through the eigen-value analysis, and it can be visually seen the vibration and sound pressure field and the contribution of major modes.

Numerical Study on Ground Vibration Reduction and Fragmentation in a Controlled Blasting Utilizing Directional U Shape Charge Holder (U형 장약홀더를 이용한 발파공법에서 지반진동 저감특성 및 파괴효율에 관한 수치해석적 연구)

  • Kim, Hyon-Soo;Baek, Beom-Hyun;Oh, Se-Wook;Han, Dong-Hun;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.34 no.1
    • /
    • pp.11-18
    • /
    • 2016
  • It is necessary to minimize ground vibration and noise due to blasting work in urban environment. The blast induced ground vibration and noise are generally generated by a portion of detonation energy, where most of the energy is utilized for rock breakage and movement of rock mass. Recently a blast method utilizing U-shaped steel charge holder was suggested to reduce the ground vibration without decreasing destructive power toward the free surface. In this study, single hole blasting utilizing U-shaped steel charge holder were simulated and the stress waves caused by the detonation of explosives were monitored using AUTODYN software. In order to examine the fragmentation efficiency of the U-shaped steel charge holder, one free face blasting models which adapt the blast induced stress waves were simulated by dynamic fracture process analysis (DFPA) code. In addition, the general blasting models were also simulated to investigate the fragmentation effectiveness of the U-shaped steel charge holder in rock blasting.

Floor Noise Isolation System of the Residential Buildings Using Waste Rubbers (폐고무를 이용한 공공주택 층간소음차단 시스템)

  • Oh, Jeong Seok;Suh, Jaechan;Kim, Jin Kuk
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.427-431
    • /
    • 2017
  • Recently, complaints of floor noise have been growing up with the rapid increase of the residential buildings. This demands the effective floor noise isolation system. Since the construction of high-rise the residential buildings will be increased even more in future, the noise isolation is a more important technology in the market. In this study, a new floor noise isolation panel (FNIP) was designed and manufactured using waste rubbers. The noise isolation was investigated at both laboratory and field conditions. Light and heavy weight shock wave showed 52 dB and 48 dB in the field test, respectively. The new system could reduce the total floor thickness by 22~42 mm.

A Study on the Noise and Vibration Reduction at Supports Center on a Tall Building Apartment (초고층 빌딩의 헬스장 구조소음 및 진동 대책)

  • 박해동;백재호;이홍기;전종균
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.527-532
    • /
    • 2003
  • 아파트의 층간소음저감을 위한 다양한 기술이 개발되고 있다. 콘크리트 건물의 단일층을 경계로 한 소음저감을 위한 공기음의 투과손실을 증가하는 방법이 주로 적용되고 있으나, 철골조 초고층아파트 스포츠 시설 운영시 이에 대한 대책으로 공기음의 대책과 구조음의 대책을 두단계에 걸쳐 수립하였다. 초고층 아파트 내부에 스포츠 시설의 배치는 이를 이용하는 사용자에게 편리성의 주지만 철골조의 특성상 충격성 진동원이 발생하는 스포츠 시설은 상하부층인 아파트에 소음진동의 연향으로 인해 이를 방지하는 설계가 요구된다. 일반적인 아파트의 충간 소음진동문제는 이를 발생시키는 상부거주자의 예절과 충간 소음진동 저감 기술이지만 아파트내부의 동일층을 경계로 위치한 스포츠 시설은 시설의 사용성에 반해 하부층에 미치는 영향을 기술적으로 저감하여야 한다. 입주한 초고층아파트의 스포츠 시설에서 발생하는 소음진동 민원문제를 풀기 위하여, 하부층 민원인이 느끼지 못하는 수준의 소음과 진동 허용치를 상호 결정하고 이를 만족하기 위한 차음 및 구조소음 설계를 수행한 사례이다.

  • PDF