• Title/Summary/Keyword: 충격 저감

Search Result 255, Processing Time 0.02 seconds

Correlation between Dynamic Characteristics of Isolation Material and Impact Noise Reduction of Light-weight Impact Source (충격음 저감재의 동특성과 실험실 경량충격음레벨 저감량의 상관관계)

  • 이주원;정갑철;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.191-195
    • /
    • 2003
  • 충격음 저감재의 동탄성계수와 감쇠계수는 차단성능을 평가하는데 있어 중요한 물성치가 된다. 저감재의 동탄성계수는 뜬바닥구조의 고유진동수를 결정짓게 되며, 저감재의 동탄성계수가 높을수록, 즉 고유진동수가 높아짐에 따라 실험실 경량충격음레벨 저감량은 지수함수적으로 감소됨을 실험을 통해 알 수 있다. 또한, 저감재를 포함한 뜬바닥구조를 1자유도 진동계로 가정한 이론값과 실험실 경량충격음레벨 저감량의 결과가 비교적 잘 일치하는 것으로 나타났으며, 이 때 감쇠계수의 영향은 반드시 고려되어야 한다.

  • PDF

Pyroshock and Vibration Characteristics of PEEK Washer Shock Absorbers (PEEK 와셔를 적용한 충격저감장치의 파이로 충격 및 진동 특성)

  • Youn, Se-Hyun;Jang, Young-Soon;Han, Jae-Hung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.3
    • /
    • pp.285-290
    • /
    • 2008
  • Pyrotechnic shock or pyroshock is characterized as a transient vibration phenomena which shows large acceleration and high frequency range up to 10kHz during the operation of separation devices where explosives are used. During the flight of a launch vehicle, pyro-shock is mainly generated at several events such as satellite separation, fairing separation and stage separation. In this paper, characteristics of pyroshock are introduced briefly, and PEEK washer shock absorber is applied for the reduction of pyroshock in the high frequency range. With some electronic devices, reduction characteristic of pyroshock using washer type shock absorber are studied. Random vibration tests are also performed for the verification of vibrational characteristics.

A Physical Properties of Lightweight Foamed Concrete According to Lightweight Aggregate Types and Foaming agent Types (경량골재와 기포제 종류에 따른 경량기포 콘크리트의 물리적 특성)

  • Kim, Ha-Seog;Lee, Sea-Hyun;Sun, Jung-Soo;Kim, Jin-Man
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.435-444
    • /
    • 2016
  • In Korea, approximately 48% of all households live in apartments, which are a form of multi-unit dwellings, and this figure increases up to 58%, when row houses and multiplex houses are included. As such, majority of the population reside in multi-unit dwellings where they are exposed to the problem of floor impact noise that can cause disputes and conflicts. Accordingly, this study was conducted to manufacture a high-weight, high-stiffness foamed concrete in order to develop a technology to reduce the floor impact noise. For the purpose of deriving the optimum mixing ratio for the foamed concrete that best reduces the floor impact noise, the amounts of the foaming agent, lightweight aggregate and binder were varied accordingly. Also, the target characteristics of the concrete to be developed included density of over $0.7t/m^3$, compressive strength of over $2.0N/mm^2$ and thermal conductivity of under 0.19 W/mK. The results of the experiment showed that the fluidity was very excellent at over 190 mm, regardless of the type and input amount of foaming agent and lightweight aggregate. The density and compressive strength measurements showed that the target density and compressive strength were satisfied in the specimen with 50% foam mixing ratio for foamed concrete and in all of the mixtures for the lightweight aggregate foamed concrete. In addition, the thermal conductivity measurements showed that the target thermal conductivity was satisfied in all of the foamed concrete specimens, except for VS50, in the 25% replacement ratio case for Type A aggregate, and all of the mixtures for Type B aggregate.

Vibration and Impact Transmission for each Variable of Woodpile Metamaterial (우드파일 메타물질의 변수 별 진동 및 충격에 끼치는 영향)

  • Ha, Young sun;Hwang, Hui Y.;Cheon, Seong S.
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.155-160
    • /
    • 2021
  • Metamaterials are complexes of elements that can create properties not found in naturally occurring materials, such as changing the direction of forces, creating negative stiffness, or altering vibration and impact properties. In the case of wood pile metamaterials that are easy to manufacture and have excellent performance in reducing vibration and shock in the vertical direction, basic research on variables affecting shock transmission is needed to reduce shock. Although research on impact reduction according to geometrical factors is being conducted recently, studies on the effect of material variables on impact reduction are insufficient. In this paper, finite element analysis was carried out by variablizing the geometrical properties (lamination angle, diameter, length) and material properties (modulus of elasticity, specific gravity, Poisson's ratio) of wood pile cylinders. Through finite element analysis, the shape of the wooden pile cylinder delivering impact was confirmed, and the effect of each variable on the reduction of impact force and energy was considered through main effect diagram analysis, and frequency band analysis was performed through fast Fourier transform. proceeded In order to reduce the impact force and vibration, it was found that the variables affecting the contact area of t he cylinder have a significant effect.

Improvement of evaluation method for impact sound reduction performance of floor coverings (바닥 상부 마감재의 충격음 저감성능에 대한 평가방법 개선)

  • Jin-Yun Chung;Han-Sol Song;Guk-Gon Song;Yong-Jin Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.161-167
    • /
    • 2023
  • Recently, floor impact sound has become a serious social problem in Korea. There is an increasing need to improve floor impact sound performance using floor covering installed on the floor of apartment houses. KS F ISO 717-2 and KS F 2863 require measurement under conditions in which the resilient material is not installed. But most apartment houses in Korea install resilient materials to reduce floor imapct sound. The performance evaluation method of floor covering should provide reduced performance for use by residents of apartment houses with resilient materials. Therefore, this paper proposes a reduction performance evaluation under the conditions in which a resilient material is installed to verify the performance of floor covering.

Development of Laminated Blade Based Shock Absorber Using Viscoelastic Adhesive Tape (점탄성 테이프를 적용한 적층형 블레이드 기반 충격저감장치)

  • Jae-Seop Choi;Yeon-Hyeok Park;Hyun-Ung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.2
    • /
    • pp.86-93
    • /
    • 2023
  • Pyrotechnic separation devices have been widely used as holding and release mechanism for deployable appendage. However, pyro-shock can cause temporal or permanent damage on shock sensitive components such as electronics, mechanism, and brittle components. This study proposed a low-stiffness blade based passive shock absorber using a multi-layered stiffener laminated with viscoelastic acrylic tapes for reducing transmitted pyro-shock upon explosion of pyrotechnic separation devices. The multi-layered structure with viscoelastic tape has high-damping characteristics to effectively secure structural integrity of low-stiffness blades under the launch environment. The design effectiveness was verified through a shock test by dropping a pendulum. The structural integrity of the shock absorber under a launch environment was evaluated through structural analysis under load conditions with a deployable payload.

Study on the Noise Reduction of the High Voltage DC Relay (고전압 DC 릴레이의 소음 저감에 관한 연구)

  • Lee, Gyeong-Ho;Kim, Yeong-Bong;Park, Hong-Tae;Son, Jin-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.788-792
    • /
    • 2007
  • 국내외의 자동차 메이커는 고효율, 저공해 자동차 개발에 집중하고 있으며, 그 방법으로 하이브리드 자동차가 최우선시 되고 있다. 하이브리드 자동차의 밧데리 팩을 구성하는 핵심 부품 중 하나인 고전압 직류 릴레이는 주행 중 엔진 구동력을 보조하는 구동모터에 전기 에너지를 공급하는 밧데리의 출력을 개폐하는 기기이다. 고전압 직류 릴레이의 개폐 동작시 발생하는 소음은 자동차 운전 중 실내로 유입되어 운전자의 승차감을 떨어뜨리는 요인이 되므로 릴레이의 개폐 동작시 발생하는 소음 저감을 위한 연구가 필요하다. 본 연구에서는 폐로(ON) 동작시 발생하는 소음 저감을 위해 소음원인 충격력을 감소시키기 위한 이중 접압스프링 구조를 제안하였으며, 소음 저감 성능평가를 수행하였다. 먼저 정확한 충격해석을 위해 고전압 직류 릴레이의 최소 동작 전압인 5.9V부터 상시 인가 전압인 12V까지 총 6개의 전압레벨에서 릴레이의 전자력을 측정하였으며, 기존 접압스프링 구조와 이중 접압스프링 구조에 관하여 외연적 탄소성 유한요소 프로그램인 LS-DYNA를 사용하여 충격해석을 수행하였다. 고전압 직류 릴레이의 소음원인 가동전극과 고정전극에서 발생하는 일차 충격력과 가동철심과 고정철심에서 발생하는 이차 충격력을 비교, 평가하였다.

  • PDF

Effect of the Interface Structure and Section Shape of Isolation Material in Floating Floor Impcat Vibration Level Decrease (뜬바닥 구조에서 층간차음재의 계면구조 및 단면형상이 충격진동량 저감효과에 미치는 영향)

  • 김범수;양수영;제현수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.296-299
    • /
    • 2004
  • 단열 완충재의 하부단면에서 양각 형태가 전체 면적에서 .차지하는 비율에 따라 진동 충격음 저감량을 실험하였다. 양각 형태가 차지하는 비율이 높더라도 진동 충격음 저감량에는 큰 성능을 나타내지 않았다. 바닥 구조에서 슬래브와 상판 사이에 단열완충재를 설치할 경우 중량 충격음이 오히려 증가하는 경향을 보이고 있다. 이것은 뜬 바닥 구조에서 완충재의 설치로 인하여 슬래브와 상판간의 거동이 다르게 발생하기 때문이다.

  • PDF

Development of a Laboratory Test Device for the Performance Evaluation of Light-weight Impact Sound (경량충격음 성능 평가를 위한 실험실용 시험장치 개발)

  • 양수영;홍병국;송화영;김범수;이동훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.505-508
    • /
    • 2004
  • 단열완충재 제품간의 경량충원 저감성능 평가를 객관적이고 신속하게 판별하기 위하여 실험실용 시험장치를 개발하였다. EVA계열 및 EPPㆍEPS계열의 단열완충재들에 대한 경량충격원 시험에서 제품간의 성능비교가 가능하였으며, 동탄성계수 및 손실계수 측정과 병행함으로써 제품들간의 우열성을 보다 정밀하게 평가할 수 있었다.

  • PDF