• Title/Summary/Keyword: 출구각

Search Result 217, Processing Time 0.022 seconds

Experimental Observation of Instability of Supersonic Submerged Jets (수중초음속제트의 불안정성에 대한 실험적 고찰)

  • 정재권;이대훈;차홍석;박승오;권세진
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.45-52
    • /
    • 2002
  • An experimental investigation on the structure and dynamic behavior of two dimensional over-expanded air jets exiting into water was carried out. The hish speed digital video imaging and static pressure distribution measurement were made to characterize the structure and time-dependant behavior of the jets. Mach number at the jet exit was 2.0 and was slightly less than the value predicted by the ideal nozzle calculation. Variance of jet spreading angle at different stagnation condition was measured as a function of mass flow rate. Periodic nature of the air jet distortion in water was observed and the frequency of the repetition was approximately 5-6 Hz for all cases tested. Three characteristic length scales were defined to characterize jet structure. $L_1$, maximum width of the plume when the periodic instability occurs, $L_2$, width of the jet where secondary reverse flow entrained jet flow and $L_3$, distance from the jet exit to the location where entrainment of the secondary reverse flow occurs. The ratio of $L_1$ and $L_2$ decreased with increasing stagnation pressure, i.e. mass flow rate. $L_3$ increased with increasing stagnation pressure. The temporal behavior of static pressure measurements also showed peak around frequency of 5, which corresponds the frequency obtained by visual measurements

Characteristics of a Wet Air Cleaning System for Removal of Air Pollutants (습식 공기청정장치의 공기오염물질 제거 특성)

  • Bae, Gwi-Nam;Kim, Yong Pyo;Baik, Nam Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.21-31
    • /
    • 2000
  • Performance characteristics of a wet air cleaning system were investigated experimentally, and discussed in relation with physicochemical properties of the target pollutants. The system is composed of an air cleaner, a separator, and a medium filter. Removal efficiency of the system was measured for ambient particles and gaseous air pollutants: $SO_2$, NO, $NO_2$, HCHO, and $NH_3$. For particle removal test, particles were introduced into the system through a fan, and the particle size distribution was measured at three locations by using two laser particle counters. Particle removal efficiency for each system component was obtained from the particle size distribution. It was found that the separator primarily removed coarse particles greater than $5{\mu}m$ in diameter, and that the medium filter mainly removed fine particles less than $5{\mu}m$ in diameter. For gas removal test, air with gaseous air pollutant was injected into the outlet of the fan, and the concentration was measured both at the upstream of the air cleaner and at the downstream of the separator. It was found that the gaseous species with high Henry's law coefficients, such as $SO_2$, HCHO, and $NH_3$, showed high removal efficiency, but the gaseous species with low Henry's law coefficients, such as NO and $NO_2$, showed low removal efficiencies. It was also found that negative ions were generated from the air cleaner.

  • PDF

A Study on Flow Distribution in a Clean Room with Multiple Exits (다수의 출구를 가지는 크린룸 내부의 기류분포에 관한 연구)

  • Lee, Jae-Heon;Lee, Sie-Un;Kim, Sukhyun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.418-425
    • /
    • 1988
  • Since conventional computer program is workable only with velocity boundary condition, in practical fluid passage such as clean room which usually have wide inlets and outlets, it is not easy to measure velocity itself because of its vector property. Furthermore a certain assumption of velocity at boundaries may lead to physically unreasonable results. From this motivation, we have developed a computer program to predict whole flow field imposed on pressure-based boundary condition which can be measured by relatively simple method. The only additional velocity boundary condition that should be imposed on to make the problem unique, are no slip condition at all walls and zero cross stream velocity at inlet. The result of present study was compared with that by Bernoulli equation being used practically. They were coincident well each other within 5%, therefore the validity of the present method is proved. In the present work, the flow field in a clean room subject to pressure-based boundary conditions at an inlet and two exits was predicted numerically. The pressure difference between the inlet and the left exit which keeps relatively low pressure among two exits is fixed as 150[Pa] and the pressure at the right exit is varied from zero to 150[Pa] by the increment of 25[Pa]. For each cases the flow characteristics in the clean room, the velocity profile at the inlet, and the flow rate through the two exits was predicted. The flow rate through the right exit imposed on relatively higher pressure than the left exit decreased linearly according to the increase of pressure of the right exit. When the pressure of the right exit is increased enough to cause back flow at the exit, the flow rate is rapidly decreased.

  • PDF

Development of a Grid-based Daily Watershed Runoff Model and the Evaluation of Its Applicability (분포형 유역 일유출 모형의 개발 및 적용성 검토)

  • Hong, Woo-Yong;Park, Geun-Ae;Jeong, In-Kyun;Kim, Seong-Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.5B
    • /
    • pp.459-469
    • /
    • 2010
  • This study is to develop a grid-based daily runoff model considering seasonal vegetation canopy condition. The model simulates the temporal and spatial variation of runoff components (surface, interflow, and baseflow), evapotranspiration (ET) and soil moisture contents of each grid element. The model is composed of three main modules of runoff, ET, and soil moisture. The total runoff was simulated by using soil water storage capacity of the day, and was allocated by introducing recession curves of each runoff component. The ET was calculated by Penman-Monteith method considering MODIS leaf area index (LAI). The daily soil moisture was routed by soil water balance equation. The model was evaluated for 930 $km^2$ Yongdam watershed. The model uses 1 km spatial data on landuse, soil, boundary, MODIS LAI. The daily weather data was built using IDW method (2000-2008). Model calibration was carried out to compare with the observed streamflow at the watershed outlet. The Nash-Sutcliffe model efficiency was 0.78~0.93. The watershed soil moisture was sensitive to precipitation and soil texture, consequently affected the streamflow, and the evapotranspiration responded to landuse type.

A Comparative Study on the Measurement Model of Anti-Corruption Index : Anti-Corruption Index and CCEJ's Corruption Index (부패지수 측정모형에 대한 비교연구 : 서울시 시정청렴성지수 측정모형과 경실련 부패지수 측정모형을 중심으로)

  • Park, Yong-Chie;Lee, Chung-Min
    • Survey Research
    • /
    • v.6 no.1
    • /
    • pp.1-38
    • /
    • 2005
  • Considering the importance of corruption index measurement model and the diffusion of popular awareness about the importance of anti-corruption, this research compared and analyzed existing corruption index measurement models. This paper has selected "Anti-Corruption Index model(ACI model)" that was developed by Seoul Development Institute and "CCEJ's Corruption Index model" which is under use by the Citizens' Coaltion for Economic Justice. These two models were analyzed in terms of appropriateness of 'the indicator and index choice method', 'the research design' and 'the use of statistical data'. This analysis shows that two models have some problems. First, at the level of indicator and index choice method, the indicators of CCEJ's corruption index model is too atomized and redundant. As not putting weight of indicator, it did not consider importance of each indicator. Citizens who evaluated the level of corruption didn't participate in the weight evaluation team, which results in failure of the model to reflect the citizens' opinion. Also, because the question about Seoul Metropolis' corruption level is not included, it is not detected difference between real corruption level and perceptive corruption level. Second, in terms of appropriateness of research design, the sample of the CCEJ' corruption index model is too small to get credibility. The objectivity of research method seems to be low because survey was performed by exit interview. In addition, 38 items are overfull in the questionnire of CCEJ's corruption index model compare to 13 items in ACI model. Also, in making up questions, the terms are redundant and unobvious. Third, in regarding with feasibility of the statistical data, the CCEJ's corruption index model uses regulation data for disciplinary punishment of 25 local governments in Seoul from 1995 to 1999. But, it is common ideas of scholars that statistical data indicates the tip of an iceberg in corruption. So for using a statistical data, it needs a data of enough quantity and has a high level credibility. In addition, objective method of giving weight is not developed. In this point of view, the use of statistical data has some limits. To solve this problem, ① objective data should be included in the indicators, ② various indicators should be developed and ③ a method of giving weight should be improved.

  • PDF

Antioxidative Effect of Onion and Mustard Powder Extracts on Fish Oil (양파 및 겨자분말 추출물의 어유에 대한 항산화효과)

  • BYUN Han-Seok;YOON Ho-Dong;KIM Seon-Bong;PARK Young-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.5
    • /
    • pp.453-458
    • /
    • 1986
  • The present study was directed to investigate the antioxidative effects of onion and mustard powder extracts on fish oil. The oxidative changes of sardine oil with and without onion and mustard powder extract were estimated by measuring peroxide value (POV), thiobarbituric acid (TBA) value, weighing method, acid value (AV) and fatty acid composition, periodically. The results obtained are summarized as follows ; From view point of POV, fat soluble fraction of onion and mustard powder showed much inhibitory effect on the oxidation of sardine oil, marked induction period to be prolonged about 18 and 20 days, respectively. But the POV in fat soluble fraction of mustard powder increased remarkably in the early stage of storage, so it did not show inhibitory effect on the oxidation of sardine oil. In the TBA value of sardine oil during storage, the water soluble fraction of onion and mustard powder were more slowly increased than other fractions. The weighing change of sardine oil, contained in the water soluble fraction of mustard powder, was slower than other fractions, marking $0.5\%$ of weight gain during 30 day storage. On the other hand water and $80\%$ ethanol soluble fractions of onion were marked $2.3\%\;and\;5.8\%$ of weight gain during 30 day storage. In the oxidative degradation of docosahexaenoic acid, water soluble fractions of mustard powder and onion extracts showed the strongest inhiditory effect.

  • PDF

Improvement of Energy Efficiency of Plants Factory by Arranging Air Circulation Fan and Air Flow Control Based on CFD (CFD 기반의 순환 팬 배치 및 유속조절에 의한 식물공장의 에너지 효율 향상)

  • Moon, Seung-Mi;Kwon, Sook-Youn;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2015
  • As information technology fusion is accelerated, the researches to improve the quality and productivity of crops inside a plant factory actively progress. Advanced growth environment management technology that can provide thermal environment and air flow suited to the growth of crops and considering the characteristics inside a facility is necessary to maximize productivity inside a plant factory. Currently running plant factories are designed to rely on experience or personal judgment; hence, design and operation technology specific to plant factories are not established, inherently producing problems such as uneven crop production due to the deviation of temperature and air flow and additional increases in energy consumption after prolonged cultivation. The optimization process has to be set up in advance for the arrangement of air flow devices and operation technology using computational fluid dynamics (CFD) during the design stage of a facility for plant factories to resolve the problems. In this study, the optimum arrangement and air flow of air circulation fans were investigated to save energy while minimizing temperature deviation at each point inside a plant factory using CFD. The condition for simulation was categorized into a total of 12 types according to installation location, quantity, and air flow changes in air circulation fans. Also, the variables of boundary conditions for simulation were set in the same level. The analysis results for each case showed that an average temperature of 296.33K matching with a set temperature and average air flow velocity of 0.51m/s suiting plant growth were well-maintained under Case 4 condition wherein two sets of air circulation fans were installed at the upper part of plant cultivation beds. Further, control of air circulation fan set under Case D yielded the most excellent results from Case D-3 conditions wherein air velocity at the outlet was adjusted to 2.9m/s.