• Title/Summary/Keyword: 축열효율

Search Result 113, Processing Time 0.025 seconds

A Study on the Heat Flow Characteristics and High Efficiency Thermal Storage of Inflowing Warm Air in the Room (실내유입온기의 열유동특성과 고효율 축열에 관한 연구)

  • Pak, Ee-Tong;Jeong, Un-Chul;Lee, Do-Young
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.13-22
    • /
    • 1997
  • A study on the distribution characteristics of inflowed warm air is important to analyze warm air storage in a room. Also, in point of energy saving during heating, warm air flow characteristics occurred by circulation and distribution of inflowed warm air should be analyzed, and the storage efficiency should be considered in order to increase efficiency of heating system. For this study, in the real-sized model room, the temperature differences between inflowing warm air and inner room air are 10, 20, $30^{\circ}C$(3steps), and the flow rates of inflowing warm air are 0.5, 1, 2, 3m/s(4steps) respectively as dynamic parameters. Also, anemos and vane diffuser are used as inlet geometric condition. Consequently, on geometric conditions, high thermal storage efficiency can be obtained with the vane diffuser, and heat flow characteristics depend on the inflowing velocity more than reference temperature difference.

  • PDF

Study and Survey of Operating Efficiency with Cool Storage System (빙축열냉방시스템의 운전효율에 관한 조사연구)

  • 손학식;심창호;김강현;김재철
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study is to maintain high efficiency and reasonable use of cool thermal storage systems operated in the domestic building sector. As the result of efficiency test from the five types of operated cool storage systems on the condition that COP ranges are 2.6 to 3.4 during the day time and 2.1 to 3.0 during the night time and it decreased by more than 30% of rated COP given 3.8 to 3.0. The Analysis of cool storage rate shows that only 3 (21.4%) systems out of 15 buildings hold to over 40% capacity for its total capacity. To prevent the decrease in operating efficiency, it should correct the malfunction of 3-way valve and expansion valve and the mistake of control values for schedule program and increase cooling tower capacity. In order to improve piping line, it needs bypass brine line off refrigerator, separation of chilled water line with Ice Slurry system at day and night time and speed control of chilled and warm water pumps. This study does require the more studies on improving difficulty of increasing cooling load with Ice on Coil system, waterproofing with Ice Ball system, COP drop during the night time with Ice Lens, low operating temperature during the day time with Ice Slurry and increasing of Power loss due to hot gas de-icing with Ice Harvest in the future.

Thermal Efficiency Analysis of the Conical Solar Concentrator According to the Black Coating of Absorber (흡수기 도색 여부에 따른 원추형 집광기 집열효율 분석)

  • Hwang, Seong Geun;Na, Mun Soo;Woo, Sung Jae;Lee, Joo Hee;Lee, Gwi Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.125-125
    • /
    • 2017
  • 본 연구에서 원추형 태양열 집광기의 흡수관 표면의 흑색 도색 여부에 따른 효율분석을 수행하였다. 원추형 집광기 시스템은 열 손실 최소화 및 집광비가 우수한 $45^{\circ}$의 원추각을 갖는 원추형 집광기를 설계 및 제작하였다. 원추형 태양열 집광시스템은 열매체 축열을 위한 온도센서가 내장된 축열조와 태양에너지를 집열시키는 원추형 집광기, 유량측정을 위한 유량계, 열매체의 강제순환을 위한 펌프로 구성되어있다. 또한 지속적인 태양추적을 위해 2축 태양 추적 장치를 설치하였다. 흡수관은 원추형 집광기의 중심부에 설비되었으며, 열매체의 순환을 위해 이중 열교환기 구조로 제작되었다. 흡수관의 길이는 열 손실을 최소화하기 위하여 집광기의 높이와 동일하게 설계하였다. 원추형 집광시스템의 작동유체인 물은 펌프에 의해 흡수관과 축열조를 강제순환 하게되고, 용량이 70L인 축열조에 흡수관으로부터 흡수된 태양 복사열이 저장된다. 원추형 집광시스템의 성능실험은 청명한 날 유량 2L/min, 4L/min, 6L/min에 대해 수행되었으며, 집열효율을 계산하여 비교 및 분석하였다. 흑색으로 도색된 흡수기를 부착한 원추형 집광시스템의 집열효율은 82.25%로 나타났으며, 무 도색 흡수관을 갖는 원추형 집광시스템은 73.26%의 집열효율을 나타내었다. 따라서 본 연구를 통해 흡수관 표면의 흑색 도색이 원추형 집광시스템의 집열효율에 큰 영향을 미친다는 것을 알 수 있었다.

  • PDF

Performance Prediction of Heat Regenerators with using Spheres: Relation between Heat Transfer and Pressure Drop (구형 축열체를 사용한 축열기의 성능예측: 압력손실과 열전달의 관계)

  • 조한창;조길원;이용국
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.35-41
    • /
    • 2003
  • Heat regenerator occupied by regenerative materials improves thermal efficiency of regenerative combustion system through the recovery of heat of exhaust gaset. By using one-dimensional two-phase fluid dynamics model, the unsteady thermal flow of heat regenerator with spherical particles, was numerically simulated to evaluate the heat transfer and pressure drop and thereby to suggest the parameter for designing heat regenerator. It takes about 7 hours for the steady state of the flow field in regenerator, in which heat absorption of regenerative particle is concurrent with the same magnitude of heat desorption. The regenerative particle experiences small temperature fluctuation below 10 K during the reversing process. The performance of thermal flow in heat regenerator varies with inlet velocity of exhaust gas and air, configuration of regenerator (cross-sectional area and length) and diameter of regenerative particle. As the gas velocity increases, the heat transfer between gas and particle enhances and with the increase the pressure losses. As particle diameter decreases, the air is preheated higher and the exhaust gases are cooled more with the increase of pressure losses.

축열공조 시스템의 최근 동향

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.273
    • /
    • pp.60-66
    • /
    • 1999
  • 에너지 공급기반이 취약한 일본에서 에너지의 이용효율 향상과 에너지 절약의 촉진은 중요한 과제의 하나이다. 이를 위하여 일본 정부는 1997년 4월 ''종합에너지대책 추진 각료회의''에서 자에너지의 추진과 전력공급의 안정 및 공급설비의 증대 억제에 의한 전력공급코스트의 저감을 위하여 전력부하 평준화의 추진을 결정하였다. 이것에 이어 ''97년 7월에는 ''전력부하평준화대책검토위원회''가 발족되고 12월에는 중간보고로서, ''전력코스트삭감=축열공조(저온도 포함) 보급확대''가 제안되어 거국적인 축열 보급확대의 필요성이 인식되게 되었다. 빙축열 공조시스템은 주간 전력소비를 억제하고 야간전력을 사용함으로써 탄산가스 배출을 삭감하는 효과도 기대되고 있어, 앞으로 일본 국내 공조시스템의 일익을 담당하며 국가에 의한 지원도 받아 급속한 시장침투가 확대될 것으로 전망되고 있다. 미쓰비시전기에서는 타사에 앞서서 선진적인 빙축열 공조시스템을 제작$\cdot$판매하고 있으며 업계의 선도적 위치를 유지하고 있다.

  • PDF

Thermal Interference Modeling in the Aquifer Thermal Energy Storage Systems (대수층 축열 시스템의 열 간섭 모델링)

  • Kim, Jong-chan;Lee, Young-min;Yoon, Woon-Sang;Koo, Min-Ho;Keehm, Young-seuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.596-599
    • /
    • 2009
  • 대수층 축열 시스템(ATES)의 효율은 지중에 저장된 열 사이의 간섭에 의해 결정이 되며, 열 간섭에 영향을 미치는 요인들은 시추공 간 이격거리, 대수층의 수리 전도도, 주입/양수량 등이 있다. 따라서 이 연구에서는 지하수-지열 거동 모델링을 통하여 열 간섭이 일어나는 현상과 열 간섭이 시스템 효율에 미치는 영향을 분석하였다. 모델링 결과로부터 이격거리는 작을수록 그리고 대수층의 수리전도도와 주입/양수량은 클수록 열 간섭이 잘 일어나는 것을 확인하였고, 열 간섭 계수가 1일 때는 시스템 효율이 상대적으로 크게 낮아지고, 열 간섭 계수가 1 미만일 때는 변화가 미미한 것을 확인하였다. ATES 를 이용한 냉난방 시스템을 시공 하고 있는 안성 연구지역에 대한 장기 예측 모델링을 수행 하였다. 모델링 결과 이격거리가 80 m 이고, 주입/양수량이 100 $m^3/day$ 일 때, 시스템 가동 7년경과 뒤 여름철과 겨울철에 계산된 시스템 효율은 각각 36 RT 와 31 RT 로 나타났다. 따라서 주입/양수량을 100 $m^3/day$로 했을 때, 냉난방 대상건물의 필요 부하인 20 RT 를 충분히 충족할 수 있을 것으로 판단된다.

  • PDF

지역난방용 축열조의 소개

  • 이건태
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.12
    • /
    • pp.35-36
    • /
    • 2001
  • 지역난방 방식에 의한 열공급이 개별적 열이용에 비해 에너지 효율이 높고 환경유해 물질의 배출을 최소화시킬 수 있는 장점으로 인해 집단 거주 지역을 중심으로 이용도가 놓아지고 있다. 따라서, 본 고에서는 지역난방 방식의 주요 설비중의 하나인 축열조의 역할, 운전, 종류 및 설계방법 등을 요약하였다.

  • PDF

동양최대 규모의 용산역사 에너지절감 설비 채택 추진 장본인 연간 약 6억원의 에너지비용 절감

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.31
    • /
    • pp.28-29
    • /
    • 2004
  • 이경희 과장은 ''용산민자역사'' 공사에서 에너지절감 설비를 책임지고 수행한 장본인이다. 그가 올해 에너지절약 유공자의 한 사람으로 지난 11월 12일 에너지절약촉진대회에서 산자부 장관상을 받은 것도 이러한 공로를 인정하고 땀방울을 격려하기 위해 그의 동료들이 적극 추천했기 때문이다. 그가 수행한 설비는 빙축열냉방시스템과 고효율 공조장비. 빙축열은 터보냉동기에 비해 연간 4억원의 절감효과를 가지고 있으며 고효율 공조장비는 연간 2억정도의 에너지세이빙효과를 가지고 있다.

  • PDF

A Development of Automation system and a way to use Solar Energy System Eefficiently in Greenhouse -Study on Growth and Yield of a cucumber in soil heating- (시설원예용 태양열 시스템의 효율적 이용과 자동화 장치개발(2) -지중가온에 의한 오이 생육 및 수량에 관한 연구-)

  • 김진현;오중열;구건효;김태욱
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.05a
    • /
    • pp.61-67
    • /
    • 1998
  • 1973년과 1978년의 1,2차 Oil Shock로 인하여 정부는 대체에너지 개발을 입법화하여 태양열의 이용을 촉진시켜왔다. 그 후 약 20년간 태양열 이용에 대한 효과적인 집열과 축열기술의 개발에 연구가 추진되었으며, 집열판(Flat-plate collector)의 개발과 열교환기, 축열장치의 설계 등 효율향상을 통하여 건축의 난방, 온수급탕 등이 주종을 이루었다. (중략)

  • PDF

Development of Power Supply Time Controller during Off-Peak Period for Thermal-storage Electric Heat Radiator (축열식 전기온풍기의 심야전력 공급시간 자동제어장치 개발)

  • Kwon, Seong-Chul;Han, Seung-Ho;Ko, Kee-Joong;Chung, Woo-Yong;Lee, Hak-Ju;Na, ki-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2334-2336
    • /
    • 2002
  • 한전에서는 수요관리정책의 일환으로 심야전력요금제도를 운영하고, 심야축열기기를 보급하여 기저부하증대 및 부하율을 개선하여 전력공급 원가절감에 노력하여 왔으나, 최근 유가상승 등의 원인으로 1999년과 2000년에 심야전력 난방기기의 급격한 보급증가로 인한 심야시간대 동계 최대 전력수요가 발생하여 22시 이후 단신간 부하급증으로 일부지역의 배전선로 회선용량부족 및 부하불평형으로 정전을 유발하게 되는 등 많은 어려움이 발생하였다. 본 논문은 심야수요급증으로 인한 대책의 일환으로 축열식 심야난방기기의 하나인 축열식 전기온풍기에 대하여 심야전력의 공급시간 자동제어장치를 개발하였다. 축열 잔열량을 측정하여 그 잉여량 만큼의 시간동안 심야전력의 공급을 지연하여 심야전력 공급초기에 집중되는 심야기기의 가동을 억제하여 심야부하를 분산하게 된다. 이로써 축열식 난방기기에 의한 동계 최대 전력수요 발생을 억제하여, 배전선로의 효율적인 운영에 기여할 것으로 기대된다.

  • PDF