• Title/Summary/Keyword: 축산 난방 시스템

Search Result 5, Processing Time 0.021 seconds

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

Construction of an Underground Heat Exchanger for Pig Housing (양돈용 지열교환기의 개발)

  • ;;H. J. Heege
    • Journal of Animal Environmental Science
    • /
    • v.1 no.2
    • /
    • pp.125-136
    • /
    • 1995
  • To use the earth heat for the pig housing, an underground heat exchanger has constructed in depth of 2.5m and 20m length. The temperature of the outlet air was max. 8 kelvin higher than that of inlet air in winter season. In spite of the -7$^{\circ}C$ outside temperature, it could keep the air temperature from the earth tube above zero degree. The heating performance was maximum in value of 3.25Wh/㎥ and average of 1.75Wh/㎥ by the airflow volume of 340㎥/h. The slope of relative humidity from outlet air has shown gentler than that of inlet air. By using the underground heat exchanger, it would be possible to prepare an relatively uniform relative humidity in the swine stalls. The temperatures on the earth, where PVC pipes are buried, have shown 10~12$^{\circ}C$ on March. This can reduce the difference between day and night temperature during this season by using the underground heat exchanger.

  • PDF

Evaluation of thermal stress of poultry according to stocking densities using mumerical BES model (BES 수치모델을 이용한 사육 밀도별 가금류 고온 스트레스 평가)

  • Kwon, Kyeong-seok;Ha, Tahwan;Choi, Hee-chul;Kim, Jong-bok;Lee, Jun-yeob;Jeon, Jung-hwan;Yang, Ka-young;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sang-yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.456-463
    • /
    • 2019
  • Micro climatic conditions within the livestock facility are affected by various factors such as ventilation, cooling, heating, insulation and latent and sensible heat generation from animals. In this study, numerical BES method was used to simulate energy flow inside the poultry house. Based on the BES method and THI concept, degree of thermal stress of poultry was evaluated according to the locations in South Korea. Comparison of THI values within the poultry house was also carried out according to the stocking densities to reflect recent animal-welfare issue. Significant decrease in thermal stress of poultry was observed when the stocking density of $30kg/m^2$ was applied in the change of the seasons(p<0.05) however, there was no statistically significant difference in summer season(p>0.05). It meant that installation of proper cooling system is urgently needed. For Iksan city of Jeollabuk-do province, total 252 hours of profit for thermal stress was found according to decrease in the stocking density.

Characteristics of Membrane Permeability on the Separation of Solid in a Liquid Livestock Manure (축분액비의 고액분리에 있어서 분리막의 투과특성)

  • 황명구;차기철;이명규
    • Journal of Animal Environmental Science
    • /
    • v.6 no.3
    • /
    • pp.175-184
    • /
    • 2000
  • A lab-scale MF membrane reactor was installed to investigate the membrane permeability, characteristics of membrane fouling at each conditions, and quality of permeate (liquid livestock manure) in the separation of solid-matters using membrane. Experiment was divided three filtration type such as follows; continuous filtration, gravity filtration, and intermittent filtration. As a result of experiment, flux 1 LMH was maintained for 7days, and trans-membrane pressure(TMP) was increased gradually under 10cmHg, but it was increased immediately after 10cmHg, respectively. However, the flux was increased, the Tmax was decreased exponential more and more. During the pure-flux test, most of the fouling of membrane was reversible. At the gravity filtration, permeate could be obtained as 1.75 LMH for 3.5days without any other electronic pressure. As an investigation of membrane surface, this study could be decided that the reason of fouling at the lower flux (Run 1 and 2) was attached matters in membrane surface, but at the higher flux (Run 4-6) was concentration polarization.

  • PDF