• 제목/요약/키워드: 축류형

검색결과 137건 처리시간 0.024초

외측 회전형 심구형 유도전동기의 특성 (The characteristics of deep slot outside rotor type IM)

  • 안병원;박영산;노영오;배철오
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.547-552
    • /
    • 2000
  • 팬의 동력원으로 사용되고 있는 일반전동기는 실치 시 팬의 전동기 부분이 돌출되어 송풍량을 제한 한다든지 곡관을 설치해야하는 문제점이 있다. 따라서 이러한 단점을 보완하기 위한 새로운 형식의 축류팬용 유도전동기를 개발하여 특성을 파악하였다. 이 유도전동기는 기존전동기와는 달리 내측이 전기자인 고정자이고 외측이 회전자로 구성되어 있다.

  • PDF

초소형 가스터빈 엔진 성능시험 (Performance test of a micro-turbine jet engine)

  • 신영기;김종문
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.788-793
    • /
    • 2001
  • Test experience with a micro-turbine jet engine is introduced. The engine provides us with valuable opportunities to experience know-hows essential for engine development. It consists of a single radial compressor and a single stage turbine. Engine starting procedure has been established after many trials and errors. Static and dynamic engine performance tests were conducted. Static performance was found to be inferior to that advertised by the manufacturer. Further improvement is needed. Dynamic performance revealed that engine thrust overshoots unfavorably for the purpose of UAV control.

  • PDF

벽체 매립형 환기용 팬 성능개선에 관한 연구 (Study on the Performance Improvement of Ventilation Fan Installed in Walls of Underground Parking Lots)

  • 권용일
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.206-211
    • /
    • 2014
  • The objective of the present study was to identify ventilation problems, and also to suggest new axial fan systems for the improvement of IAQ in the underground parking lots. Numerical results for air mean-velocity, local mean age, and sound power level are presented along with some of fan angles. The results showed the influence of airflow patterns on the fan performances installed in the underground parking lots. Discharge air volume is increased with the angle of the blade. And also, the main factors affecting the noise of the ventilation fan was found to be a rotational speed.

전산해석에 의한 일체형 원자로용 주냉각재 펌프의 성능분석 (Performance Evaluation of a Main Coolant Pump for the Modular Nuclear Reactor by Computational Fluid Dynamics)

  • 윤의수;오형우;박상진
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.818-824
    • /
    • 2006
  • The hydrodynamic performance analysis of an axial-flow main coolant pump for the modular nuclear reactor has been carried out using a commercial computational fluid dynamics (CFD) software. The prediction capability of the CFD software adopted in the present study was validated in comparison with the experimental data. Predicted performance curves agree satisfactorily well with the experimental results for the main coolant pump over the normal operating range. π Ie prediction method presented herein can be used effectively as a tool for the hydrodynamic design optimization and assist the understanding of the operational characteristics of general purpose axial-flow pumps.

축류송풍기 부착형 공냉식 열교환기의 진동 저감 (Vibration Reduction of an Air Cooled Heat Exchanger with Axial Flow Fan)

  • 정구충;최연선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.75-81
    • /
    • 2000
  • Vibration problems induced by an air cooled heat exchanger with axial flow fan were investigated during the operation of a petrochemical plant. Two different studies were done; one was experimental field test and the other was theoretical verification. To find main cause of the blade passing frequency of the fan after installing additional blockage board at the air inlet of the axial fan, the frequency spectrum was measured. The vibrations of the blade passing frequency became higher. The natural frequency of driving support of the heat exchanger was theoretically calculated. It was approximately equal to the blade passing frequency. During the normal operation of the plant, it was impossible to modify the structure of the driving support. Instead, the blade number was increased to reduce vibration level. It increased the ratio of the forcing frequency to the natural frequency of the driving support over the resonance region.

  • PDF

일체형원자로 SMART 냉각재 순환펌프의 전산성능예측 (Computational Performance Prediction of Main Coolant Pump for the Integral Reactor SMART)

  • 김민환;이재선;박진석;김종인;김긍구
    • 한국전산유체공학회지
    • /
    • 제8권3호
    • /
    • pp.32-40
    • /
    • 2003
  • CFD analyses of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump including suction and discharge parts are presented and compared with experimental data. The purpose of the current study is to validate the CFD method for the performance analysis of the main coolant pump for SMART and to investigate the effect of suction and discharge shapes on the pump performance. To generate a performance curve, not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicts the experimental head value. In the range of the higher flow rates, the results are also in very good agreement with the experimental data, in magnitude but also in terms of slope of variation. For lower flow rates, the results shows that the analysis considering the suction and discharge well describe the typical S-shape performance curve of the axial pump.

물 가스 개질 고속선회 소각로에 관한 융합연구 (Convergent Study on the Hydro-Gas Reforming Cyclo-Incinerator)

  • 한두희
    • 한국융합학회논문지
    • /
    • 제11권10호
    • /
    • pp.231-236
    • /
    • 2020
  • 물 개질반응 고속선회 소각로 시험 설비를 제작하였다. 개질 반응실과 연소실은 직접 연결이 되게 하였다. 소각로와 집진 장치는 일체형으로 만들어 2중 격벽식 공기 냉각 구조로 만들었다. 송풍기를 집진장치 내부에 내장하여 공간적으로 효율성을 향상시켰다. 집진부의 옆에 부착된 다수의 집진통을 이용하여 분진을 수거하여 백필터가 별도로 필요없는 축류 유동형 다단식 집진장치를 적용하였다. 배출되는 가스 중 다이옥신을 측정한 결과 기준치 이하의 결과를 얻었다. 배출가스와 중금속을 측정한 결과 환경기준치 이하의 결과를 얻었다.

스윕 각이 적용된 부분 흡입형 초음속 축류 터빈의 정상, 비정상 공력 특성에 관한 수치적 연구 (Numerical Study on Steady and Unsteady Flow Characteristics of Nozzle-Rotor Flow in a Partial Admission Supersonic Axial Turbine with Sweep Angle)

  • 정수인;김귀순
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.173-179
    • /
    • 2012
  • 본 논문에서는 부분 흡입형 초음속 터빈의 로터 블레이드에 ${\pm}15^{\circ}$의 스윕 각도를 적용하여 그에 의한 효과와 공력 특성을 살펴보기 위해 정상상태 유동해석과 비정상상태 유동해석을 동시에 수행하고 그 결과를 비교해 보았다. 3차원 Navier-Stokes 유동해석에는 상용 코드인 FLUENT 6.3 Parallel을 사용하였다. 모든 계산 케이스들에서 정상상태 유동해석에 비해 비정상상태의 경우가 손실이 더욱 크게 나오는 결과를 나타내었다. 후방스윕(BSW)모델은 기준모델(NSW)에 비해 팁 간극으로 빠져나가는 누설 손실량을 줄이는데 큰 효과가 있었고 비정상상태 유동 해석에서는 로터 출구면 정효율의 증가현상이 더욱 뚜렷하게 나타났다.

  • PDF

충동형 터빈 캐스케이드의 깃 하중 측정에 관한 연구 (A Study on the Blade Load Measurement of Partial-admission Turbine Cascade)

  • 임동화;정진만;이은석;김진한;최종수
    • 한국항공우주학회지
    • /
    • 제35권2호
    • /
    • pp.143-148
    • /
    • 2007
  • 액체 추진 로켓을 구동하는 충동형 터빈은 크기가 작고 가벼워야 하며 큰 출력을 발생시켜야 한다. 충동형 터빈은 초음속 조건에서 작동되기 때문에 유동 특성이 매우 복잡하여 성능 예측은 주로 수치해석에 의존해 왔다. 그러나 신뢰성을 확보하기 위하여는 해석결과를 실험으로 검증하는 과정이 필요하다. 본 연구에서는 설계에 사용되는 주요 변수들의 영향을 확인하기 위하여 회전하는 3차원 축류 터빈을 2차원 형상으로 모사하여 실험하였다. 먼저 노즐 출구에서의 마하수를 측정하였으며, 이론적인 노즐 추력식을 유도하여 터빈 블레이드에 작용하는 깃하중을 계산하였고 측정된 결과와 비교하였다. 또한 추력 계수를 구하고 이를 통해 터빈 출력을 예측하여 설계 요구 조건의 타당성을 확인하였다

고반복율 및 고정밀방식을 이용한 펄스형 $CO_2$ Laser 시스템 설계 및 평가 (Design and evalution of pulsed $CO_2$ laser system using high repetition ratio and high precision)

  • 김흥수;김휘영
    • 한국컴퓨터산업학회논문지
    • /
    • 제2권8호
    • /
    • pp.1055-1062
    • /
    • 2001
  • 본 연구에서는 1KHz 부근의 펄스 반복율을 가지는 경제적이고 컴팩트한 펄스형 $CO_2$ 레이저의 개발에 관해서 기술하였다. 고압 고주파 펄스 변압기와 수 십 KHz의 스위칭에 적합한 IGBT를 사용한 고압 펄스전원 장치를 레이저 공진기에 접목시켜 새로운 방식의 고반복 $CO_2$ 레이저 장치를 개발하였다. 전원장치에 사용된 2개의 IGBT를 정밀하게 제어하기 위해서 제어부에는 PIC 마이크로프로세서가 사용되었고 공진기는 수냉방식의 저속축류형으로 제작되었다. 완성된 장치의 펄스 반복율과 동작압력 그리고 레이저 매질 가스의 혼합비의 변화에 따른 레이저빔의 출력 특성실험을 통하여 가스 배압비 $CO_2$$N_2$:He = 1:9:15펄스 반복율 700 Hz, 동작압력 15 Torr에서 최대 레이저 출력 약 20.5 W, 최대 효율 약 8%를 달성하였다.

  • PDF