• Title/Summary/Keyword: 최적화질

Search Result 205, Processing Time 0.034 seconds

A Simulation Study on Image Quality of Virtual Monochromatic Image using Dual-energy Method (이중에너지 방법을 이용한 가상 단색 영상의 화질 시뮬레이션 연구)

  • Son, Ki-Hong;Lee, Soo-Yeul;Kim, Dae-Hong;Chung, Myung-Ae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.553-558
    • /
    • 2022
  • The purpose of this work was a simulation study to evaluate the virtual monochromatic (VM) image quality of blood vessels compared to the monochromatic image. Dual-energy images were obtained based on the linear attenuation coefficients of five materials at 50 keV and 80 keV at low- and high-energies, respectively. A weighting factor is required to synthesize the VM image, and the liver and bone were used as basis materials to obtain the weighting factor. VM images were synthesized at energies ranging from 30 keV to 100 keV. Image quality was evaluated by Contrast to noise ratio (CNR) and noise by setting calcium and contrast medium as signals and blood as background. According to the results, the energies with the maximum CNR were 50 keV and 60 keV for calcium and contrast medium, respectively. The energies showing the minimum noise were 70 keV, 70 keV, and 60 keV in calcium, iodine contrast medium, and blood, respectively. The VM image can contribute to the improvement of diagnostic performance in CT examination because it can implement an image at the optimal energy that minimize noise and maximize CNR.

Denoising of Digital Mammography Images Using Wavelet Transform (웨이블릿을 이용한 디지털유방영상의 노이즈 제거)

  • Choi, Seokyoon;Ko, Seongjin;Kang, Sesik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.181-189
    • /
    • 2013
  • The optimum exposure parameters are found when examined using the automatic mode in FFDM. improve the image quality by applying denoising algorithm and propose methods to reduce AGD(Average Grandular Dose) a patient can receive. For the experiment, Nuclear Associates Model 18-222 phantom was the used, and the entrance dose and AGD were measured. And then, Signal, Noise, SNR and FOM(Figure of Merit) were measured, compared and analyzed image denoising before and after. As the experiment result, first, SNR was the highest at Mo/Mo 23kVp and W/Rh 35kvp was the lowest for the average glandular dose. It showed to use 28kVp of W/Rh to be the best through the result of FOM. SNR was the highest at Mo/Mo 23kVp(image denoising), and it showed to W/Rh and 28kVp to be the best in the FOM result which AGD was considered at the same time. By the image denoising, it is possible to reduce noise while maintain important information in the image.

Role of Radiation Therapy for Stage III Thymoma (제 3기 흉선종에서 방사선치료의 역할)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.16-20
    • /
    • 2001
  • Purpose : To evaluate the effectiveness and tolerance of the postoperative radiation therapy for patients with Stage III thymoma and to define the optimal radiotherapeutic regimen Materials and Methods : We retrospectively analyzed the records of 24 patients with Stage III thymoma who were referred for postoperative radiation therapy in our institution from June, 1987 to May, 1999. Surgical therapy consisted of total resection in one patient, subtotal resection in seventeen, and biopsy alone in six patients. Age of the patients was ranged from 20 to 62 years with mean age of 47 years. Male to female ratio was 14 to 10. Radiation therapy was delivered with linear accelerator producing either 6 MeV or 10 MeV photons. The irradiated volume included anterior mediastinum and known residual disease. The supraclavicular fossae were not irradiated. The delivered total dose was ranged from 30 to 56 Gy. One patient received 30 Gy and eighteen patients received minimum of 50 Gy. Follow up period was ranged from 12 months to 8 years with median follow up of 40 months. Results : The overall local control rate for entire group of patients was $67\%$ at 5 years. The cumulative local failure rates at one, three and five year were $18\%,\;28\%\;and\;33\%$, respectively. In patients treated with subtotal resection and biopsy alone, local control rate was $76\%\;and\;33\%$, respectively. The actuarial observed survival rate at 5 years was $57\%$, and actuarial adjusted survival at 5 years was $72\%$. The difference between 5 year survival rates for patients treated with subtotal resection and biopsy alone was not statistically significant $(62\%\;vs\;30\%)$. Conclusion : We might conclude that postoperative radiation therapy was safe and effective treatment for patients with Stage III thymoma. Postoperative radiation therapy is recommended in cases where tumor margin is close or incomplete resection is accomplished.

  • PDF

Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study (약하게 조영증강된 병변의 유방 전용 CT 영상의 대조도 개선을 위한 적응적 영상 재조정 방법: 팬텀 연구)

  • Bitbyeol Kim;Ho Kyung Kim;Jinsung Kim;Yongkan Ki;Ji Hyeon Joo;Hosang Jeon;Dahl Park;Wontaek Kim;Jiho Nam;Dong Hyeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1477-1492
    • /
    • 2021
  • Purpose Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions, an adaptive image rescaling (AIR) technique was proposed. Materials and Methods Two disks containing five identical holes and five holes of different diameters were scanned using 60/100 kVp to obtain single-energy CT (SECT), dual-energy CT (DECT), and AIR images. A piece of pork was also scanned as a subclinical trial. The image quality was evaluated using image contrast and contrast-to-noise ratio (CNR). The difference of imaging performances was confirmed using student's t test. Results Total mean image contrast of AIR (0.70) reached 74.5% of that of DECT (0.94) and was higher than that of SECT (0.22) by 318.2%. Total mean CNR of AIR (5.08) was 35.5% of that of SECT (14.30) and was higher than that of DECT (2.28) by 222.8%. A similar trend was observed in the subclinical study. Conclusion The results demonstrated superior image contrast of AIR over SECT, and its higher overall image quality compared to DECT with half the exposure. Therefore, AIR seems to have the potential to improve the detectability of lesions with dedicated breast CT.

Basic Principles of CT Dose Index and Understanding of CT Parameter for Dose Reduction Technique (CT선량지표의 원리와 선량감소 방안에 관한 연구)

  • Kim, Jung-Su;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.51-61
    • /
    • 2015
  • Computed tomography(CT) using radiation have potential risks. All medical radiographic examinations should require the justification of medical imaging examinations and optimization of the image quality and radiation exposure. The CT examination was higher radiation dose then general radiography. Especially pediatric CT examinations need to great caution of radiation risk. Because of pediatric patient was more sensitive of radiation exposure. Therefore, physician should consider the knowledge of CT radiation exposure indicator information for reduce a needless radiation exposure. This article was aim to understanding of CT exposure indicator, size-specific dose estimates by American Association of Physicists in Medicine (AAPM) report 204, XR 25 and understanding of CT dose reduction technique.

Dynamic Textual Information Presenting Methods on Digital Displays (디지털 디스플레이에서의 동적 문자정보 제시 방법)

  • Lee, Kyong-Hee;Cheng, Hong-In
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.45-52
    • /
    • 2005
  • Displays, playing an essential role in HCI, have been developed to deliver more vivid and live pictures. LCD and PDP have the most common usage among various displays to present the dynamic textual information in restricted and open places. Important and unsolicited information is being provided by hundreds of displays while we don't even perceive the information. Watching context, effective color combinations of the text and background, speeds of presentation, contexts, and types of display for leading method, moving words cross the display from right to left, were investigated with readability, comprehensibility, and overall satisfaction were compared. LCD peformed better than PDP on all comparisons u4th typical text (black, white) and background (white, black) color better than other color combinations. Normal and fast text presentation was believed more preferred when only textual information was given while slower presentation was evaluated more efficient if multimedia contents were presented with textual information.

  • PDF

An Image Coding Algorithm for the Representation of the Set of the Zoom Images (Zoom 영상 표현을 위한 영상 코딩 알고리듬)

  • Jang, Bo-Hyeon;Kim, Do-Hyeon;Yang, Yeong-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.5
    • /
    • pp.498-508
    • /
    • 2001
  • In this paper, we propose an efficient coding algorithm for the zoom images to find the optimal depth and texture information. The proposed algorithm is the area-based method consisting of two consecutive steps, i) the depth extraction step and ii) the texture extraction step. The X-Y plane of the object space is divided into triangular patches and the depth value of the node is determined in the first step and then the texture of the each patch is extracted in the second step. In the depth extraction step, the depth of the node is determined by applying the block-based disparity compensation method to the windowed area centered at the node. In the second step, the texture of the triangular patches is extracted from the zoom images by applying the affine transformation based disparity compensation method to the triangular patches with the depth value extracted from the first step. To improve the quality of image, the interpolation is peformed on the object space instead of the interpolation on the image plane.

  • PDF

Application Method of Unmanned Aerial Vehicle for Crop Monitoring in Korea (국내 작황 모니터링을 위한 무인항공기 적용방안)

  • Na, Sang-il;Park, Chan-won;So, Kyu-ho;Ahn, Ho-yong;Lee, Kyung-do
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.5
    • /
    • pp.829-846
    • /
    • 2018
  • Crop monitoring can provide useful information for farmers to establish farm management strategies suitable for optimum production of vegetables. But, traditional monitoring has used field measurements involving destructive sampling and laboratory analysis, which is costly and time consuming. Unmanned Aerial vehicle (UAV) could be effectively applied in a field of crop monitoring for estimation of cultivated area, growth parameters, growth disorder and yield, because it can acquire high-resolution images quickly and repeatedly. And lower flight altitude compared with satellite, UAV can obtain high quality images even in cloudy weather. This study examined the possibility of utilizing UAV in the field of crop monitoring and was to suggest the application method for production of crop status information from UAV.

The Integration of Segmentation Based Environment Models from Multiple Images (다중 영상으로부터 생성된 분할 기반 환경 모델들의 통합)

  • 류승택;윤경현
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.7
    • /
    • pp.1286-1301
    • /
    • 2003
  • This paper introduces segmentation based environment modeling method and integration method using multiple environment map for constructing the realtime image-based panoramic navigation system. The segmentation-based environment modeling method is easy to implement on the environment map and can be used for environment modeling by extracting the depth value by the segmentation of the environment map. However, an environment model that is constructed using a single environment map has the problem of a blurring effect caused by the fixed resolution, and the stretching effect of the 3D model caused when information that does not exist on the environment map occurs due to the occlusion. In this paper, we suggest environment models integration method using multiple environment map to resolve the above problem. This method can express parallax effect and expand the environment model to express wide range of environment. The segmentation-based environment modeling method using multiple environment map can build a detail model with optimal resolution.

  • PDF

Bottleneck-Free Architecture of A High Speed Printer (고속프린터의 병목 없는 구조)

  • Lee, Kang-Woo
    • The KIPS Transactions:PartA
    • /
    • v.11A no.3
    • /
    • pp.115-128
    • /
    • 2004
  • The proliferation of Information Technology and Business Automation become the mainstay of the growth of world printer market. Especially the demand for high speed printers increases drastically as the need for printing service station in networked computing environment grows. However outstanding research activities are seldom reported. Only efforts are currently focused on the printing quality and development of application programs for low or midium speed printers. This stimulates the research for high-speed printers. In this paper, we first defined the architectural components of high-speed printers so that the performance requirements can be satisfied. The individual impacts of each module on overall throughput are then elaborately analysed. Based on this result, we accomplished well-tuned system architecture which presents up to 163.52 PPM. Another contribution of this paper can be found in that this is one of the first articles that deal with the architecture and the performance of high-speed printers.