• Title/Summary/Keyword: 최적응집

Search Result 299, Processing Time 0.028 seconds

Reduction of Dehydrated Cake by the Optimization of Flocculation Factors and the Single Flocculant/Dual Flocculation System (응집인자 최적화 및 다단응집 시스템을 이용한 탈수 케이크 감량)

  • Kim, Hyung-Jun;Bae, Young-Han;Lee, Sang-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.839-846
    • /
    • 2008
  • The flocculation characteristics of polyacrylamide base flocculants were estimated to reduce the moisture content of the dehydrated cakes. The dewaterability for sewage sludge was found to have a marked effect depending on the flocculant type, agitating speed and time, kind of dissolution water, etc. The optimal agitating speed and time were 700 rpm and 3 sec, respectively, in this experimental condition. and the dewaterability was proportion to the agitating speed upto 700rpm. When recycle water as the dissolution water was used, the solution viscosity of all kind of flocculants was decreased. However, the change of its viscosity are not proportioned to the dewaterabilities for each flocculant. Flocculation system of combinations of the first and sencond flocculation using single flocculant was investigated. Effects of the ratio of first and second dosage for dual flocculation on the dewaterability were also investigated. The optimum conditions of dual flocculation system are 75% and 50% as first dosages for low and high viscous flocculant for total dosage of common flocculation, respectively. Based on the results, an overall mechanism of dual flocculation system is proposed and it is envisaged that optimization of flocculation processes in this way can result in considerable savings in cost.

Removal of Color and non-biodegradable organic matter from biologically treated effluent by coagulation. (응집에 의한 생물학적 처리수의 색도 및 난분해성 유기물 제거)

  • Seo, Tae-Gyeong;Park, Sang-Min;Park, No-Baek;Jeon, Hang-Bae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.859-863
    • /
    • 2008
  • 축산폐수, 침출수 등의 고농도 폐수를 생물학적으로 처리할 경우 최종 방류수는 강한 색도를 띠며 고분자량의 유기물질을 다량 함유한다. 이는 생물학적으로 분해하기 어려운 유기성 복합체와 생화학적 반응에 의한 중간생성물로 색도를 띠는 천연유기물질(NOM)을 포함한다. 생물학적 처리수의 색도는 심미적인 불안감, 방류수역의 수질오염 및 공중보건상의 잠재적 위해성을 갖는다. 또한, 수자원 이용측면에서 정수처리공정에서의 약품투입량 증가와 특히, 소독부산물 생성이라는 잠재적 문제점이 뒤따른다. 따라서 이러한 문제점을 해소하기 위한 생물학적 2차 처리수의 후속처리가 요구되며, 실제로 난분해성 유기물과 색도를 제거하기 위한 흡착, 막 분리, 고급산화(AOP) 및 화학적 응집 등의 물리-화학적 공정에 대한 연구가 수행되어왔다. 특히, 화학적 응집은 무기응집제 또는 고분자중합체(Polymer)를 이용하여 콜로이드성 입자와 색도를 띠는 난분해성 유기물을 전기적 불안정화를 유도함으로서 흡착 및 응집과정을 통해 제거하는 공정으로 많은 연구자들에 의해 연구되어왔다. 그러나 난분해성 유기물과 색도제거는 대상원수의 성상과 화학적 특성 등에 따라 각각의 제거효율과 최적 운전조건이 상이하게 나타난다. 화학적 응집공정은 비교적 높은 제거효율을 보이지만, 운전 및 유지관리의 기술적 어려움, 경제적 비효율성 등으로 인하여 적용에 어려움을 겪고 있는 실정이다. 본 논문에서는 생물학적 혐기-호기성 공정에서 방류되는 축산폐수의 2차 처리수를 대상으로 화학적 응집에 의한 색도 및 난분해성 유기물의 제거거동을 고찰하였다. 대상 처리수의 $TCOD_{Cr}$ 농도는 평균 410 mg/L인 반면, $BOD_5$는 7-15 mg/L 범위로 난분해성 유기물을 다량 함유하고 있음을 알 수 있었다. 이에 황산알루미늄(Aluminium sulfate; $Al_2(SO_4){\cdot}14H_2O$)과 염화철(ferric chloride)의 무기응집제를 이용하여 자 테스트(jar test)를 수행한 결과, 동일한 응집제 주입량에서 염화철의 유기물 제거 효율이 높은 것으로 나타났다. 황산알루미늄과 염화철의 경우 각각의 응집제 주입율 5.85mM에서 89%, 7.03mM에서 97.5%의 최대 유기물 제거효율을 보여주었으며, 이 때 최종 pH는 4.0-5.6 범위이었다. 한편, 대상 원수 내의 콜로이드성 입자 또는 용존성 유기물의 작용기(functional group)는 일반적으로 음으로 하전 되어 있어 응집에 의해 잘 제거되지 않는 특성을 가지고 있다. 따라서 과량의 응집제를 주입하여 다가의 양이온성 금속염을 흡착시켜 전기적으로 중화시키고, 생성된 침전성 수화물 내에 포획 또는 여과시켜 제거하게 된다. 이 때, 금속염 수화종의 전하밀도가 응집효율에 영향을 주는 것으로 알려져 있는데, 다가의 양이온은 전기적 이중층(Double layer) 압축에 의한 불안정화를 향상시킬 수 있기 때문에다. 또한, 2가 금속염은 색도유발물질과 흡착하여 humate 또는 fulvate 등의 착화합물(complex)을 형성시켜 응집효율을 향상시킬 수 있다. 따라서 본 연구에서는 생물학적 2차 처리수의 화학적 응집처리에 있어서 알루미늄염 등의 다가이온 첨가가 응집에 미치는 영향을 관찰하고, 후속되는 플록형성 및 침전공정에 의한 제거효율을 비교, 평가함으로써 2차 처리수로부터 난분해성 유기물과 색도를 보다 효과적이고 경제적으로 제거할 수 있는 최적인자를 도출하고자 하였다.

  • PDF

Treatment of Livestock Wastewater with Coagulant-loess (황토를 이용한 축산폐수의 처리에 관한 연구)

  • Park, Jin-Hee;Kim, Bo-Guk;Won, Chan-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1799-1808
    • /
    • 2000
  • To investigate the applicability of loess as a coagulant. the optimum conditions of coagulation and efficiency comparison of several coagulants (PAC, PACS, LAS) in chemical treatment of livestock wastewater were performed. As a result, the optimum mixing ratio of loess and lime(CaO) was 3:7. The optimum dosage of the mixed coagulant was 30 g/L. The optimum speed for rapid mixing of the mixed coagulant was 200 rpm at 1 min. and the optimum speed for slow mixing was 50 rpm at 10 min. The mixed coagulant showed the removal efficiency of turbidity, SS, BOD, $COD_{cr}$. T-P and TKN to 95.8%, 92.5%, 71.6%, 71.1%, 98.2% and 32.5%, respectively, which was better than other several coagulants. The mixed coagulant was possible to use as substitutional coagulants of traditional coagulant, and the producted sludge can use as a soil amendments.

  • PDF

Determination of Set Point of Streaming Current for Optimum Coagulation (최적 응집을 위한 Streaming Current의 기준값 설정에 관한 연구)

  • Yu, Myong-Jin;Jang, Mi-Jeong;Park, Gui-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.34-41
    • /
    • 2006
  • The objectives of this study were to investigate the affecting factors on streaming current(SC) and to evaluate set point(SP). For the study, a pilot scale apparatus with a capacity of 12 L/min was operated at Guui water intake of Seoul. SC was monitored with varying poly aluminium chlorides(PACs) dose and water quality parameters like conductivity, turbidity, temperature, and pH. The removal efficiencies were evaluated in terms of turbidity and dissolved organic carbon(DOC) with varying coagulation conditions. The effects of affecting factors on SC and SP were also estimated. According to the result observed from the variation of SC with water quality parameters during the experimental period, tendencies of SC and conductivity were very similar, and SC and conductivity had a strong linear relation. At the optimum condition of coagulation, SP decreased as the rainy season changed to the dry season, during the experimental period. Especially, in condition of low turbidity, conductivity had relatively more effect on SC than turbidity. As conductivity increased, SP decreased and coagulant dose per unit increase of SC gradually increased. In view of the results so far obtained, it may be possible to determine the SP range considering the real time variation of water quality, especially conductivity.

Removal of Color from a Biological Piggery Wastewater Treatment Effluent by Chemical Coagulation (화학적 응집을 이용한 생물학적 돈분폐수 처리수의 색도제거)

  • Park, Noh-Back;Seo, Tae-Kyeong;Choi, Woo-Young;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.1047-1053
    • /
    • 2008
  • This study was to evaluate the optimum conditions for chemical coagulation to remove color from the effluent of a piggery wastewater treatment process. The DOC concentration in the effluent was about 227.3 mg/L, color was 2,430 CU, turbidity was 22.1 NTU, and UV$_{254}$-absorbance was 3.7 cm$^{-1}$. The fractions of hydrophobic, transphilic, and hydrophilic substance of the effluent was about 55.3%, 17.4%, 27.3% respectively. Also, molecular weight cut-off(MWCO) of below 0.5 K, 0.5 K to 1 K, 1 K to 10 K, 10 K to 30 K, and over 30 K were 74.2%, 7.3%, 5.5%, 7.1%, and 5.9% respectively. SCD(streaming current Detector) was used to find out the optimum pH values and coagulant dosages. The optimum dosages and pH of Al$^{3+}$ were 5.84 mM and 5.3, while those of Fe$^{3+}$ were 9.25 mM and 5.0, respectively. At optimum conditions of coagulation, color removal efficiencies for aluminium sulfate and ferric chloride were as high as 91.9 and 98.7%, respectively. Chemical coagulation showed good performance to remove color from on biologically treated piggery wastewater.

Characteristics of Coagulation-Flocculation-Sedimentation Process with BAF Process on Drinking Water Treatment using Nakdong River Water (BAF와 연계한 응집.침전공정에 의한 정수처리 특성)

  • Ko, Su-Hyun;Choi, Jeung-Woo;Hyun, Kil-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.3
    • /
    • pp.237-243
    • /
    • 2000
  • 최근에 경제성장과 생활향상에 따른 물수요량이 급증함과 동시에 소비자의 질적요구가 강화되고 있는 실정이다. 기존 상수원인 하천의 수질오염으로 인하여 소비자의 요구사항을 충족시키기 위해서는 기존 정수처리법의 개선이 요구된다. 따라서 본 연구에서는 기존 급속여과법의 전염소 처리공정 및 응집.침전 공정의 개선을 통하여 음용수 수질을 개선하고자 하였다. 전염소 대신에 적용한 생물막여과 공정(BAF)의 처리효과 및 응집.침전 공정의 경우는 교반강도에 따른 침전효과에 따른 수질특성을 조사하였다. BAF공정은 탁월한 $NH_4$-N의 제거를 통하여 후속공정에 대한 오염부하량을 저감시킬수 있었고, 응집.침전의 경우 본 연구에서 제안한 응집제 주입량에 따른 교반강도의 실험식인에 의하여 구한 최적교반강도용 용집공정에 적용시 응집.침전의 효과를 향상시킨 수 있어 음용수 수질 향상을 기대 할 수 있었다.

  • PDF

Dissolution Characteristics of Magnesite Ore in Hydrochloric Acid Solution and Removal of Impurity (마그네사이트 광석(鑛石)의 염산용해(鹽酸熔解) 특성(特性) 및 불순물(不純物) 제거)

  • Eom, Hyoung-Choon;Park, Hyung-Kyu;Kim, Chul-Joo;Kim, Sung-Don;Yoon, Ho-Sung
    • Resources Recycling
    • /
    • v.18 no.6
    • /
    • pp.38-45
    • /
    • 2009
  • Dissolution characteristics of magnesite ore in hydrochloric acid solution and removal of impurity were investigated. The dissolution yield increased with increasing temperature and with decreasing particle size. The optimum conditions for dissolution were found to be reaction period of 120 min, reaction temperature of $80^{\circ}C$ and mean particle size of 100. Under optimal dissolution condition the extraction of Mg was 98%. It was found that most of Si and Al exist in the residue, and they can be removed by filtering. Dissolved impurity ions were precipitated as metal hydroxides by pH adjustment. Polymers were used as coagulants for metal hydroxides and the suitable coagulant dosage was 1mg/100ml of non-ionic polymer.

Biochemical Properties of Locular Fluid Lectin of Tomato (토마토 Locular Fluid Lectin의 생화학적 성질)

  • Roh, Kwang-Soo
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.48-53
    • /
    • 2008
  • Lectin was isolated from locular fluid of tomato by affinity chromatography using Sephadex G-200, and studied its some biochemical properties. SDS-PAGE of the isolated lectin revealed a tetramer composed of two identical subunits with molecular weights of 39 and 23 kDa. The isolated lectin was agglutinated by trypsin-treated human ABO type blood erythrocytes with similar potency, and the most activity of agglutination was found at B type blood erythrocyte. This lectin showed maximum thermal stability at $70^{\circ}C$, and was relatively stable to heat with the higher activity at $40-80^{\circ}C$. The optimal temperature and pH of this lectin were $50^{\circ}C$ and pH 7.0, respectively.