• Title/Summary/Keyword: 최적압전길이

Search Result 7, Processing Time 0.027 seconds

A Study on the Step-up Properties of Piezoelectric Ceramic Transformer (압전세라믹 변압기의 승압특성에 관한 연구)

  • 김용혁;최명규;이원식;김재호
    • Electrical & Electronic Materials
    • /
    • v.2 no.2
    • /
    • pp.143-151
    • /
    • 1989
  • 본 논문은 압전 세라믹스 재료를 사용한 장방형 압전 변압기의 승압특성에 관한 연구이다. 승압기구 분석을 위하여 진동모드에 따른 주파수 Spectrum을 구동부측곽 발전부측에 대해 각각 조사하였다. 시편구조(전극길이, 두께, 폭)에 따른 진동상태와 승압비를 평가하고 압전 변압기로써 가져야 될 최적조건을 제시하였다. 또한 부하저항에 병렬로 연결된 등가손실저항과 발전부 공진임피던스 사이의 관련성을 검토하였다.

  • PDF

Characteristics Variation Analysis by Shape of Piezoelectric Ultrasonic Transducer with Non-Uniform Thickness (두께 불균일 압전 초음파 트랜스듀서의 형태에 따른 특성변화 해석)

  • Kim, Dong-Hyun;Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.271-278
    • /
    • 2008
  • The electro-mechanical characteristics were theoretically analyzed for the wideband ultrasonic transducer made of non-uniform thickness piezoelectric vibrator. This paper proposes a combination of exponential functions which describes the thickness variation along the length of the vibrator to derive the input admittance and power transfer function of the transducer. The bandwidth and the power transfer function of the transducer were investigated while the lateral shape of the vibrator changes. The results showed there is an optimum shape for the wideband characteristics of the transducer, and the bandwidth has increased up to over 100% as the ratio of minimum value of thickness to maximum value decreases. However, the power transfer function had a downward trend as the ratio of thickness decreases. Also we confirmed that even though the value of transfer function increases as the length of the piezoelectric vibrator increases, the shape providing wideband characteristics is very limited. It means that precision processing is required to manufacturing a wideband ultrasonic transducer with high efficiency.

Effect of Piezoactuator Length Variation for Vibration Control of Beams (보의 진동제어를 위한 압전 액추에이터의 길이변화 효과 연구)

  • Lee, Young-Sup
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.11
    • /
    • pp.1185-1191
    • /
    • 2008
  • This paper presents an approach to define an optimal piezoactuator length to actively control structural vibration. The optimal ratio of the piezoactuator length against the beam length when a pair of piezoceramic actuator and accelerometer is used to suppress unwanted vibration with direct velocity feedback(DVFB) control strategy is not clearly defined so far. It is well known that DVFB control can be very useful when a pair of sensor and actuator is collocated on structures with a high gain and excellent stability. It is considered that three different collocated Pairs of piezoelectric actuators (20, 50 and 100 mm long) and accelerometers installed on three identical clamped-clamped beams($30{\times}20{\times}1mm$). The response of each sensor-actuator pair requires strictly positive real(SPR) property to apply a high feedback gain. However the length of the piezoactuator affects the SPR property of the sensor-actuator response. Intensive simulation and experiment show the effect of the actuator length variation is strongly related with the frequency range of the SPR property. Thus an optimal length ratio was suggested to obtain relevant performance with a good stability under the DVFB strategy.

Resonant Mode Analysis of Microwave Film Bulk Acoustic Wave Resonator using 3D Finite Element Method (3차원 유한 요소법을 이용한 초고주파 압전 박막 공진기의 공진 모드해석)

  • 정재호;송영민;이용현;이정희;고광식;최현철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.18-26
    • /
    • 2001
  • In this paper, the resonant characteristics and modes of the film bulk acoustic wave resonator (FBAR) used in 1~2 GHz frequency region are analyzed by it's input impedance which was calculated by three dimensional finite element method formulated as eigenvalue problem using electro-mechanical wave equation and boundary condition. It was extracted that the resonant and the spurious characteristics considering the effects of electrode area and shape variation and unsymmetry of upper and lower electrode. Those effects couldn't be analyzed by on dimensional analysis, e.g. Mason equivalent model. The simulation result was confirmed by comparing with the simulation data from Mason model analysis and the measured data of the ZnO FBAR fabricated using micro-machining technique. Also, through the simulation of the area variations of FBAR, it was obtained that the optimum ratio of length and thickness is 20:1 and the minimum ratio is 5:1 to operate thickness vibration mode.

  • PDF

Design and Evaluation of Ultrasonic dental scaler produced for Finite Element Analysis (유한요소 해석을 통한 치과용 초음파 Scaler의 설계 및 평가)

  • Kim, Chul-Min;Lee, Young-Jin;Jeong, Young-Hun;Paik, Jong-Hoo;Kang, Kook-Jin;Lee, Jeong-Bae;Lee, Seung-Dae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.20-20
    • /
    • 2009
  • 치아의 치석제거 및 치골절삭에 사용되는 초음파 스케일러는 일반적으로 마그넷형과 압전형으로 구분할 수 있으며, 최근에 들어 소형화, 저전력, 정밀성, 저비용 등의 장점으로 인해 압전형이 주로 사용되고 있다. 국내의 대부분의 치과에서 한 대 이상 운용되는 초음파 스케일러는 대부분 유럽 제품으로며, 국내에서는 이를 대체하기 위한 제품이 출시되고 있으나 아직까지 유럽 제품에 비해 출력강도, 정밀도 등에서 성능이 모자란 현실로 시장에서 외면 받고 있다. 본 연구에서는 앞서 언급한 압전 초음파 스케일러에 대한 체계적인 연구를 진행하여 외국에 비해 상대적으로 성능이 떨어지는 초음파 스케일러의 성능을 개선하고자 하였다. 이를 위하여 스케일러의 진동 발생부, 즉 압전 세라믹과 SUS 재질의 head, tail 부로 구성된 진동발생부의 최적구조톨 도출하기 위하여 유한요소 해석을 실시하였으며, 스케일러의 중심주파수 28kHz에서 최대 출력이 발생할 수 있는 구조를 도출하였다. 스케일러의 Head 와 Tail 부문의 두께와 직경, 길이 변화에 따른 중심주파수 및 출력 변위의 경향분석을 실시하였으며, 이상의 결과를 바탕으로 실제 스케일러를 제작하여 시뮬레이션의 유효성을 검증하였다. 이상의 과정으로 거쳐 개발된 압전 초음파 스케일러는 다양한 Tip 종류의 영향을 최소화할 수 있으며, 중심주파수는 28~30kHz 에서 뛰어난 성능을 나타내어 기종 유럽제품의 성능을 앞지르는 특성을 확보할 수 있었다.

  • PDF

A study on driving characteristics of thin-type ultrasonic motor (Thin-type 초음파모터의 구동특성연구)

  • Jeong, Seong-Su;Jun, Ho-Ik;Chong, Hyon-Ho;Kim, Jong-Wook;Park, Min-Ho;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.193-193
    • /
    • 2009
  • Thin-type 초음파모터의 구조는 크로스형태의 앓은 스테이터에 윗면과 아랫면에 각각 8개의 압전세라믹이 부착된 형태이고, 압전세라믹의 분극방향은 로터와 접촉하는 스테이터의 중심부인 네 개의 타점에서 순차적인 타원변위가 생성되도록 결정된다. 유한요소해석프로그램인 ATILA 5.2.4를 사용하여 형태, 길이, 두께, 스테이터 재질, 클램프특성이 최적 설계된 모델을 제작하였고, 푸쉬풀 게이지, x-y 스테이지, rpm 메터, 토크 게이지, 맨코더, AD컨버터를 이용하여 피드백 제어 구동시스템을 구성하였다. 그림 I은 마이크로컨트롤러 (ATmega)와 피드백회로를 이용한 구동 드라이버를 보여준다. 한 주기에서 1/4분주의 순차적인 네 개의 구형파를 생성하고, 이를 push-pull회로를 통하여 90도의 위상차가 나는 정현파를 생성하여 초음파 모터의 구동전원으로 사용한다. 피드백 회로인 엔코더와 AD 컨버터는 초음파모터의 속도를 피드백하여 정속도 운전을 위한 전압제어에 사용되었다. 특성 측정 결과, 제품화된 드라이버와 비교하여 큰 차이를 보이지 않았고 피드백 회로를 통하여 부하변화에 따른 속도의 극심한 변화를 0.2~0.4[N]의 범위에서 정속도 운전이 가능하였으며, 장시간의 운전에도 온도 및 속도특성이 안정적임을 확인하였다.

  • PDF

Driving Characteristic of The Thin Type Ultrasonic Motor using Microcontroller (Microcontroller를 이용한 박형 초음파모터의 구동특성)

  • Jeong, Seong-Su;Jun, Ho-Ik;Chong, Hyon-Ho;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.201-201
    • /
    • 2008
  • 박형초음파모터의 구조는 그림 1(a) 와 같이 크로스형태의 앓은 스테이터에 윗면과 아랫면에 각각 8 개의 압전세라믹이 부착된 형태이다. 압전세라믹의 분극방향은 로터와 접촉하는 스테이터의 A, B, C, D 네 개의 타점에서 순차적인 타원변위가 생성되도록 결정된다. 유한요소해석프로그램인 ATILA 5.2.4를 사용하여 최적설계를 한 결과 폭 3[mm], 길이 18[mm], 두께 1.8[mm], Brass 재질, Mid surface clamp 조건에서 입력전압 18[Vrms] 일 때 0.3[${\mu}m$]의 변위를 보였다. 최적설계된 모델을 제작하였고, 정확한 실험결과를 얻기 위해서 푸쉬풀게이지, x-y스테이지, rpm 메타, 토크게이지를 이용하여 실험테이블을 구성하였다. 그림 1(b) 는 마이크로컨트롤러를 이용한 구동 드라이버를 보여준다. 한 주기에서 1/4분주의 순차적인 네 개의 구형파를 생성하고, 이를 push-pull회로를 동하여 90도의 위상차가 나는 정현파를 생성하여 초음파 모터의 구동전원으로 사용한다. 엔코더와 AD 컨버터를 이용하여 정속도 운전을 위한 피드백 제어가 된다. 제안된 구동드라이버를 이용하여 측정한 결과, 구동 주파수 88.6[kHz], 입력전압 [40Vrms], preload 0.2 [N]에서 130 [rmp] 의 속도와 25 [gfcm] 의 토크특성을 보였다. 압력전압을 증가시킬수록 속도는 선형적인 증가를 보였고, 토크는 이와 반대로 감소하는 특성을 보였다. 피드백 제어회로가 없는 경우에는 preload 변화에 따른 극심한 속도 변화를 보였고, 피드백 제어를 하였을 경우에는 0.2~0.4[N]의 범위에서 정속도 운전이 가능함을 확인하였다. 기존의 주파수발생기와 파워 엠프를 이용한 구동장비와의 특성비교에서도 큰 차이를 보이지 않았으며, 장시간의 운전에도 안정적인 구동이 가능함을 확인하였다.

  • PDF