• Title/Summary/Keyword: 최적감쇠

Search Result 248, Processing Time 0.032 seconds

Ultimate Strength Analysis of Connections of Floating Pendulum Wave Energy Converter (부유식 진자형 파력발전장치의 연결부 최종강도해석)

  • Sohn, Jung Min;Cheon, Ho Jeong;Shin, Seung Ho;Hong, Key Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.1
    • /
    • pp.36-41
    • /
    • 2014
  • A floating offshore structure has high tendency to occur the buckling when compressive, bending and shear loads applied. When the buckling is occurred, in-plane stiffness of structure is remarkably decreased. And it has a harmful effect on the local structural strength as well as global structural strength. In the present study, it has been investigated the ultimate strength of tubular members which is located between a floater and a damping plate of the floating pendulum wave energy converter. Nonlinear finite element method is conducted using the initial imperfection according to 1st buckling mode which is obtained from the elastic buckling analysis. It is also noted the ultimate bending strength characteristic varying with a diameter, thickness and stiffeners of the tubular member.

Development of Cable Excitation System for Evaluating Dynamic Characteristics of Stay Cables (사장교 케이블 동특성 평가를 위한 케이블 가진시스템 개발)

  • Kim, Nam-Sik;Jeong, Woon;Seo, Ju-Won;Ahn, Sang-Sup
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.71-79
    • /
    • 2003
  • As a critical member of cable-stayed bridges, stay cables play on important role of supporting the entire structure. Traffic, wind or rain-wind induced vibrations of stay cables would be a major cause of degrading both safety and serviceability of the bridge. One of the effective alternatives to solve this problem is to employ the cable dampers. In order to design the cable damper optimally, it is necessary to exactly estimate the dynamic characteristics of the existing cables. To achieve more reliable dynamic properties of stay cables, precise excitations inducing forced vibration are needed. Therefore, in this study, a cable excitation system(exciter) controlled digitally was developed. And to evaluate the performance of the cable exciter developed, a solution of the differential equation of cable motion considering the exciter was derived, Using the cable exciter, sine sweeping and resonance tests on a cable model were carried out to obtain the dynamic characteristics effectively.

Performance analysis of CSMA based MAC protocols for underwater communications (수중 통신에 적합한 CSMA기반 매체접근제어 프로토콜 연구)

  • Song, Min-Je;Jang, Youn-Seon
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1068-1072
    • /
    • 2018
  • In underwater communications, there are many challenges due to energy limitations, long propagation delay, low data rate, and high power loss, unlike terrestrial RF communications. Especially, the propagation delay of underwater acoustic channel is five orders of magnitude higher than in electro-magnetic terrestrial channels due to the low speed of sound(1,500m/s). Thus, the MAC protocols for terrestrial communications are not suitable for underwater network. In this paper, we studied the considerations for MAC protocol in underwater acoustic channel. Here, we concentrated on CSMA based MAC protocols. From the results, we confirmed that the number of control packets has an important effect on the performance in underwater environment. These results would be useful in designing MAC protocols for underwater acoustic communications.

Rainfall estimation and evaluation for a small-scale rainfall radar in Busan Eco-Delta Smart city (부산 에코델타 스마트시티 소형 강우레이더 강우추정 및 평가)

  • Wan Sik Yu;Kyoung Pil Kim;Shin Uk Kang;Seong Sim Yoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.277-277
    • /
    • 2023
  • 최근 기후변화의 영향으로 호우의 발생빈도가 증가하고 있는 추세이며, 도시지역의 호우는 돌발적이고 국지적인 특성을 가지고 있어 인명과 재산피해 역시 증가하고 있으며, 급격한 도시화로 인한 구조적으로 홍수에 취약한 실정이다. 국지성 도시호우는 저층(1 km 내외)에서 형성되는 강우가 지배적이며, 기존의 대형레이더는 높은 산 정상에 설치되어 1.5 km 이상의 강우관측을 중심으로 운영됨에 따라 저층강우의 탐지 및 변동성 관측에 취약하여, 이에 대형 레이더에서 뿐만 아니라 도시단위의 국지성 호우관측에 대응할 수 있는 소형 레이더 기반 고정밀 강우관측 마련 및 운영 기술이 필요하다. 현재 K-water는 부산 에코델타 스마트시티에 도시 물재해 플랫폼 구현의 일환으로 돌발강우사전 탐지 및 도시의 신속·정확한 강우 관측을 위하여 높은 시공간 해상도를 제공하는 이중편파X 밴드 소형 강우레이더를 설치하고, 효율적 운용을 위해 각 고도각에서의 빔 차폐율을 확인하고 이를 고려한 최적 관측전략을 수립하였다. 또한 Z-Phi 방법을 이용한 반사도 감쇠 보정 기술을 개발하였으며, 강우 추정을 위해 하이브리드 고도면 합성 기법(HSR) 기법을 적용하고 검증하였다. 이후 소형 레이더의 정량적 추정강수를 이용하여 강우예측 정보를 생산하기 위해 이류모델을 적용하고, 비슬산과 소형 합성 레이더 추정강수로 선행 10분에서 180분까지 예측할 수 있도록 개발하였다. 또한, 지상강우관측 자료와의 정확도 비교 평가를 수행하고, 행정구역 및 표준유역의 예측 평균강우량을 생산하여 부산 에코델타 스마트시티 도시 물재해 통합관리 시스템과 연계운영을 위한 후속 과업을 수행중에 있다.

  • PDF

Study on flexible segment efficiency for seismic performance improvement of subsea tunnel (해저터널 내진성능 향상을 위한 Flexible segment 효용성 연구)

  • Jang, Dong-In;Kim, Jong-Ill;Kwak, Chang-Won;Park, Inn-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.503-515
    • /
    • 2017
  • Underground structures that have recently become larger are required to be stable not only during normal times but also during earthquakes. Especially, it is very important to maintain the stability of the subsea tunnels during the earthquake. The objective of this paper is to verify the effectiveness of the flexible segment, which is one of the breakthrough facilities to maintain the stability of the subsea tunnel during the earthquake using the shaking table test. Another goal of this paper is to propose the optimum position of the flexible segment through 3D dynamic numerical analysis based on the verified results from shaking table tests. The 1g shaking table test considering the similarity ratio (1:100) to the cross section of the selected artificial subsea tunnel was carried out considering the Geongju and Artificial seismic waves, longitudinal and lateral wave, and with/without flexible segments eight times or more. As a result of the shaking table test, it was confirmed that the flexible segment is effective in improving the seismic performance of the undersea tunnel in all the experimental results. In addition, 3D dynamic numerical analysis was performed to select the optimum position of the flexible segment which is effective for improving seismic performance. As a result, it was confirmed that the seismic acceleration is attenuated when the flexible segment is installed adjacent to the branch section in subsea tunnel.

Extraction of Parameters for Acupoint Discrimination and Design of discrimination system (경혈식별을 위한 파라메터 추출 및 식별시스템의 설계)

  • 이용흠;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.89-101
    • /
    • 2001
  • The conventional pattern-methods for discrimination of acupoint, meridian line which is the basic object of diagnosis and medical treatment in oriental medicine is discriminated the conduction point by the stimulation in body skin with DC. But, it is not sufficient to truth in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper is extracting the optimal parameter of frequency and waveform in order to improve the conventional pattern, and proposing the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, this algorithm proposes to be able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It is able to decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. It is compared the performance of system applying the extracted optimal parameter and algorithm, and it is confirmed that there is difference in discrimination parameter of acupoint reacted to the individual and the meridian. It is compared that discrimination, coincident ratio of the traditional acupoints as the acupoint stimulation pattern. It is confirmed truth of optimal parameter and discrimination algorithm. Keyword: Meridian, Discrimination, Coincident, Body effect, Reproductivity, SPAC, Optimal parameter.

  • PDF

Estimation of Rockbolt Integrity by Using Non-Destructive Testing Techniques(I) -Numerical and Experimental of Applicability- (비파괴 시험기법을 이용한 록볼트의 건전도 평가(I) -수치해석 및 실험적 적용성 평가-)

  • Lee, Jong-Sub;Lee, Yong-Jun;Eom, Tae-Won;Han, Shin-In;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.1
    • /
    • pp.3-12
    • /
    • 2006
  • The purpose of this study is to describe the Non-Destructive Testing(NDT) of the rockbolt and investigate the applicability of the NDT methods to estimate the integrity of the rockbolt. To examine the rockbolt integrity including rockbolt itself and grouting material, two methods are adopted: numerical and experimental methods. In the numerical method, the numerical code DISPERSE is used to analyze the dispersion of the rockbolt. The dispersion curve shows the effects of the thickness and stiffness of grouted materials on the embedded rockbolt. Therefore, the optimal frequency for the integrity test of the rockbolt is obtained: 20~120kHz in L(1,0) mode. In the experimental methods, destructive and non-destructive tests are carried out in a laboratory. In the non-destructive test, the low frequency mode generated by an impact and t he high frequency mode generated by an ultrasonic transducer seem to characterize the rockbolt condition readily. The experimental results show that the guided waves attenuate more significantly when the stiffness of the grouted material increases and/or the zone of the defect increases. Meanwhile, the ultimate capacity of rockbolt was evaluated through the pull-out tests and is compared to the NDT results. This study demonstrates that the NDT is a valuable tool for the rockbolt integrity evaluation.

  • PDF

Evaluation of high power ultrasonic energy transmission characteristics of a liquid matching layer by using sonoluminescence (소노루미네센스를 이용한 액체정합층의 고출력 초음파에너지 전달특성 평가)

  • Kim, Jungsoon;Kim, Haeun;Son, Jinyoung;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.5
    • /
    • pp.408-416
    • /
    • 2021
  • In the ultrasonic dispersion, in order to avoid direct contact of the radiation surface of ultrasonic transducers with a liquid sample, the liquid sample is separated by a glass container and it receives ultrasonic energy through an acoustic medium. The transmission efficiency of the ultrasonic energy in the multi-layered ultrasonic system is an important factor. In this study, we suggested a method that can improve the ultrasonic energy transfer efficiency by using a propylene glycol solution as a liquid matching layer in the multi-layered acoustic system. In this method, a propylene glycol solution was filled between the Langevin-type ultrasonic transducer and the luminol solution and the sonoluminescence phenomena in the luminol solution, which is caused by nonlinear effect of high power ultrasound radiated from the transducer, was examined by using a Photo Multiplier Tube (PMT). The transmission efficiency depending on the concentration of propylene glycol solution was observed, and we can see that as the concentration of the propylene glycol solution increased, the matching effect increased while the acoustic attenuation increased. It was confirmed that there is an optimal concentration compromised these two conflicting conditions, and the optimum concentration of the propylene glycol solution was determined experimentally.

Optimization and Development of Prediction Model on the Removal Condition of Livestock Wastewater using a Response Surface Method in the Photo-Fenton Oxidation Process (Photo-Fenton 산화공정에서 반응표면분석법을 이용한 축산폐수의 COD 처리조건 최적화 및 예측식 수립)

  • Cho, Il-Hyoung;Chang, Soon-Woong;Lee, Si-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.642-652
    • /
    • 2008
  • The aim of our research was to apply experimental design methodology in the optimization condition of Photo-Fenton oxidation of the residual livestock wastewater after the coagulation process. The reactions of Photo-Fenton oxidation were mathematically described as a function of parameters amount of Fe(II)($x_1$), $H_2O_2(x_2)$ and pH($x_3$) being modeled by the use of the Box-Behnken method, which was used for fitting 2nd order response surface models and was alternative to central composite designs. The application of RSM using the Box-Behnken method yielded the following regression equation, which is an empirical relationship between the removal(%) of livestock wastewater and test variables in coded unit: Y = 79.3 + 15.61x$_1$ - 7.31x$_2$ - 4.26x$_3$ - 18x$_1{^2}$ - 10x$_2{^2}$ - 11.9x$_3{^2}$ + 2.49x$_1$x$_2$ - 4.4x$_2$x$_3$ - 1.65x$_1$x$_3$. The model predicted also agreed with the experimentally observed result(R$^2$ = 0.96) The results show that the response of treatment removal(%) in Photo-Fenton oxidation of livestock wastewater were significantly affected by the synergistic effect of linear terms(Fe(II)($x_1$), $H_2O_2(x_2)$, pH(x$_3$)), whereas Fe(II) $\times$ Fe(II)(x$_1{^2}$), $H_2O_2$ $\times$ $H_2O_2$(x$_2{^2}$) and pH $\times$ pH(x$_3{^2}$) on the quadratic terms were significantly affected by the antagonistic effect. $H_2O_2$ $\times$ pH(x$_2$x$_3$) had also a antagonistic effect in the cross-product term. The estimated ridge of the expected maximum response and optimal conditions for Y using canonical analysis were 84 $\pm$ 0.95% and (Fe(II)(X$_1$) = 0.0146 mM, $H_2O_2$(X$_2$) = 0.0867 mM and pH(X$_3$) = 4.704, respectively. The optimal ratio of Fe/H$_2O_2$ was also 0.17 at the pH 4.7.

Luminescence and Photostimulated Luminescence of $Eu^{2+}$ in Alkaline Earth Chlorides (염화알칼리토금속 화합물에 도핑된 $Eu^{2+}$ 이온의 광발광 및 광자극발광특성)

  • Kim, Sung-Hwan;Kim, Sun-Chil
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.141-145
    • /
    • 2006
  • In this study, $Eu^{2+}$ ion was used as an activator in order to enhance the PL(photoluminescene) and PSL(photostimulated luminescence) intensity of $MCl_2:Eu^{2+}$(M = Ca, Sr, Ba)phosphors and the chracteristics of PL and PSL of the phosphors were investigated. The emission of $MCl_2:Eu^{2+}$(M = Ca, Sr, Ba) phosphors shows a shift wavelength when the host caution changes. The optimal preparing conditions of $CaCl_2:Eu^{2+}$ phosphor were 0.5 mol% of $EuCl_2$ and the sintering temperature were $745^{\circ}C$, 45 min. in $H_2$ atmosphere. The PL and PSL spectra of $CaCl_2:Eu^{2+}$ locate in the range of $365{\sim}388\;nm$, peaking at 370 and 380 nm. The optimal preparing conditions of $BaCl_2:Eu^{2+}$ phosphor were 0.5 mol% of $EuCl_2$ and the sintering temperature were $905^{\circ}C$, 45 min. in $H_2$ atmosphere. The PL and PSL spectra of $BaCl_2:Eu^{2+}$ locate in the range of $370{\sim}460\;nm$, peaking at 398 nm. The optimal preparing conditions of $SrCl_2:Eu^{2+}$ phosphor were 0.5mol% of $EuCl_2$ and the sintering temperature were $840^{\circ}C$, 45min. in $H_2$ atmosphere. The PL and PSL spectra of $SrCl_2:Eu^{2+}$ locate in the range of $380{\sim}440\;nm$, peaking at 407 nm. The dose response of the $MCl_2:Eu^{2+}$(0.5 mol%)(M = Ba, Sr) phosphors were linear within $0.25{\sim}200\;mGy$ of 100 kV X-ray and the PSL intensity of the $SrCl_2:Eu^{2+}$ and $BaCl_2:Eu^{2+}$ phosphors faded to approximately 60 and 40% respectively after 120 min at room temperature.

  • PDF