• Title/Summary/Keyword: 최저유속

Search Result 31, Processing Time 0.022 seconds

Oceanographic Conditions in Relation to Laver Production in Kwangyang Bay, Korea (광양만의 김 생산과 양식장환경과의 관계에 대하여)

  • HONG Jae-Sang;SONG Choon Bok;KIM Nam-Gil;KIM Jong Man;HUH Hyung Tack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.3
    • /
    • pp.237-247
    • /
    • 1987
  • The present study deals with the physico-chemical and meteorological conditions in Porphyra-cultivation ground to determine the relationship between laver production and its environmental factors in Kwangyang Bay from January to April in 1986. As a result, major environmental factors which are thought to have a great influence upon the poor harvest during the cultivation period are as follows; 1) the excessive rainfall in the beginning of cultivation period 2) the accumulation of suspended matters on the thallus of laver 3) the decrease of current velocity and the stagnation of the water in the cultivation ground.

  • PDF

A case of discharge estimation for unmeasured operation period by real-time discharge measurement (자동유량측정시설 미계측 운영기간에 대한 유량산정 적용사례)

  • Cho, Sang Uk;Oh, Dong Heon;Baek, Jong Seok;Kim, Chi Young;Cha, Jun Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.320-320
    • /
    • 2020
  • 하천이용을 위한 다양한 개발사업이 이루어지고 있고 대규모 보가 설치되면서 과거와는 다른 변화된 수리조건에서 기존의 방법으로는 유량자료 생산이 더욱 어려워졌기 때문에 자동유량측정시설의 필요성이 증대되어 조위나 배수 영향을 받는 지점에서 기존 방식을 대체하거나 보완할 수 있는 새로운 유량측정방법으로 자리매김하게 되었다. 자동유량측정시설은 2020년 4월 현재 기준으로 한강 19개소, 낙동강 23개소, 금강 10개소, 영산간 10개소 총 62개소가 운영 중이다. 하지만 4대강 사업 이후, 수질 문제 등의 이유로 2017년 6월부터 순차적으로 4대강 보를 개방하여 보 운영수위에 따라 유속측정이 곤란한 관측소가 증가하고 있으며 이로 인해 환경부 수자원정보센터에서는 보 운영 별 최저수위에서도 자동유량측정시설 운영이 가능하도록 시설물을 개선하는 사업을 실시하고 있다. 개선사업 기간 동안 자료생산의 공백이 발생하지 않도록 인력에 의한 유량측정성과를 확보하여 관측소별 대안유량 산정방법을 개발하였다. 개발된 대안유량은 관측소 개선공사 기간뿐만 아니라 보 운영에 따른 수위저하로 인한 미계측 기간에도 적용하여 유량자료의 손실을 최소화 하도록 하였다. 2019년 운영현황을 범위로 전체 관측소 62개 중 4대강 보 구간에서 관측소 개선공사 8개소와 수위 저하로 유속측정이 불가능한 12개소 중 수위-유량관계곡선식 적용이 가능한 2개소를 제외한 10개소를 대상으로 평균 76일 결측이 발생한 것에 대해 대안유량 산정방법을 적용하여 전 기간 유량자료를 보완하였다. 그 결과 전체 2019년 자동유량측정시설 유량산정률은 99.8%로 자료생산의 공백을 최소화 할 수 있었으며 향후, 보 구간 자동유량측정시설 개선이 완료된 후에도 장비 이상 또는 이상치 발생 시에도 대안유량 산정방법을 활용하여 자료생산의 공백을 최소화 할 수 있을 것으로 기대하고 있다.

  • PDF

The variation of channel flow through opening the gate at Shimgok-Cheon by using SMS program (SMS를 이용한 인천 심곡천 하구 수문개방에 따른 하천흐름변화 분석)

  • Kim, Chanyeong;Jeong Gwansoo;Kim, Youngkyu
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.6
    • /
    • pp.385-392
    • /
    • 2024
  • By installing the gate at the estuary to prevent the inflow of seawater into the river, it was prevented the inflow of seawater into the river, but as a result, the velocity of the river was rapidly decreased, turning it into a river with almost stoped flow. Since a river must have flow to maintain its function, in this study, it examined improving the flow of the river through the operation of a gate in Simgok-cheon where is a river that has been closed by a hydrological system at the estuary and almost stoped flow. It was considered that if the gate are operated according to the tide level, it could be changed into a river through which water flows by raising it to 0.49 m/s, which is about 10 times faster than the current slow flow rate of 0.05 m/s while maintaining the highest or lowest target elevation.

Morphological characteristics of the upper airway and pressure drop analysis using 3D CFD in OSA patients (폐쇄성 수면무호흡 환자의 상기도 형태의 특징과 압력강하에 관한 3차원 전산유체역학해석)

  • Mo, Sung-Seo;Ahn, Hyung-Taek;Lee, Jeong-Seon;Chung, Yoo-Sam;Moon, Yoon-Shik;Pae, Eung-Kwon;Sung, Sang-Jin
    • The korean journal of orthodontics
    • /
    • v.40 no.2
    • /
    • pp.66-76
    • /
    • 2010
  • Objective: Obstructive sleep apnea (OSA) is a common disorder which is characterized by a recurrence of entire or partial collapse of the pharyngeal airway during sleep. A given tidal volume must traverse the soft tissue tube structure of the upper airway, so the tendency for airway obstruction is influenced by the geometries of the duct and characteristics of the airflow in respect to fluid dynamics. Methods: Individualized 3D FEA models were reconstructed from pretreatment computerized tomogram images of three patients with obstructive sleep apnea. 3D computational fluid dynamics analysis was used to observe the effect of airway geometry on the flow velocity, negative pressure and pressure drop in the upper airway at an inspiration flow rate of 170, 200, and 230 ml/s per nostril. Results: In all 3 models, large airflow velocity and negative pressure were observed around the section of minimum area (SMA), the region which narrows around the velopharynx and oropharynx. The bigger the Out-A (outlet area)/ SMA-A (SMA area) ratio, the greater was the change in airflow velocity and negative pressure. Conclusions: Pressure drop meaning the difference between highest pressure at nostril and lowest pressure at SMA, is a good indicator for upper airway resistance which increased more as the airflow volume was increased.

Estimation of Water Purification Ability with Applying Porous Concrete to Weir and Riverbed Materials (다공성 콘크리트의 보 및 하상재료 적용에 따른 하천 수질정화 능력 평가)

  • Choi, I-Song;Kim, Jin-Hong;Choi, Gye-Woon;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.1013-1023
    • /
    • 2003
  • This study was performed to improve water quality of stream by applying hydraulic structures (weir and river bed material) made of porous concrete. The physical and chemical characteristics of porous concrete were measured to estimate application possibility of it in hydraulic structures and it was considered as a proper material for the hydraulic structures. In the results of comparison for the component of matters attached on the hydraulic structures made of porous and ordinary concrete, DW (dry weight) amount attached on porous concrete was 1.6 times higher than that on ordinary concrete under the condition of the same flow rate but influence by flow rate (difference of 10 times) was not shown. Therefore, we could understand that the material of media was more important in DW amount than flow rate. The rate of AFDM (ash free dry mass) to DW also was more at porous concrete than at ordinary concrete. Especially, the high rates of nitrogen and phosphorous in matters attached on porous concrete verify that they were removed by assimilation, adsorption and metabolism of periphyton. The removal percentage of SS, BOD, COD, T-N and T-P by hydraulic structures applying porous concrete compared with ordinary concrete was increased by 34.6%, 36.9%, 33.9%, 18.3% and 21.6%, respectively. Therefore, applying porous concrete to hydraulic structure is expected to contribute to improvement of stream water quality.

SOME PHYSICAL OCEANOGRAPHIC RESEARCH ON KWANG YANG BAY ( I ) (광양만의 물리적 해황에 관한 연구 ( I ))

  • 장지원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.10 no.1
    • /
    • pp.1-18
    • /
    • 1974
  • Some coastal oceanographic investigations in Kwang Yang Bay were carried out bimonthly from April to September (The first half period of the research project) in 1974. The behaviour of the waters, distributions of water temperature and salinity and diffusion characteristic by dye release experiments in the bay are studied for the problems of practical importance in connection with water pollution. Velocities and directions of tidal currents at five fixed stations were observed. And dye diffusion experiment was also carried out on the sea. According to the results from this study, the salinity of the water is lower, ranging from about $28\;\textperthousand\;to\;32\textperthousand$, on all over the surface in the bay with the cause that the fresh water flows in from the Sumjin river. Diffusivities in this sea by means of Rhodamine B diffusion elliperiment were $785.6\;{\times}\;10^2\;\textrm{m}^2/sec$ in major axis, $15.6\;{\times}\;10^2 \;\textrm{m}^2/sec$/sec in minor axis in the direction on patch after 30 minutes from the dye release.

  • PDF

Study on Ventilation Efficiency of A Naturally Ventilated Broiler House-( I ) Summer Season (자연환기식 육계사내의 환기효율성 조사연구-( I )하절기)

  • 이인복;유병기;정문성;윤진하;전종길;김경원;성시흥
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • Most of broiler houses in Korea have the trouble of environmental control such as suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens. Accordingly, it is very urgent to develop optimum designs of naturally and mechanically ventilated broiler houses for Korean climate. In this study, the internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were measured at a naturally ventilated broiler house. The data were collected during summer season including local weather data. It was found that the difference between measured and optimum air temperatures was $14.0^{\circ}C$ in maximum during the summer time. The daily maximum range of internal averaged air temperature was found $10.5^{\circ}C$ while the uniformity was $5.2^{\circ}C$ in maximum. The maximum, average, and minimum internal averaged relative humidity were 89.3%, 73.7%, and 49.2%, respectively while locally measured were 95.1% and 47.2%, respectively in maximum and minimum. Considering Temperature-humidity index, during summer season, over 97% of totally rearing period was shown that counter plan is needed for thermal stress while it was very dangerous situation for 22% of the rearing period. The ammonia gas and dust concentrations were seriously affected by the broilers activity, growth level, and relative humidity.

  • PDF

Flow analysis of the Sump Pump (흡수정의 유동해석)

  • Jung, Han-Byul;Noh, Seung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.673-680
    • /
    • 2017
  • sump pump is a system that draws in water that is stored in a dam or reservoir. They are used to pump large amounts of water for cooling systems in large power plants, such as thermal and nuclear plants. However, if the flow and sump pump ratio are small, the flow rate increases around the inlet port. This causes a turbulent vortex or swirl flows. The turbulent flow reduces the performance and can cause failure. Various methods have been devised to solve the problem, but a correct solution has not been found for low water level. The most efficient solution is to install an anti-vortex device (AVD) or increase the length of the sump inlet, which makes the flow uniform. This paper presents a computational fluid dynamics (CFD) analysis of the flow characteristics in a sump pump for different sump inlet lengths and AVD types. Modeling was performed in three stages based on the pump intake, sump, and pump. For accurate analysis, the grid was made denser in the intake part, and the grid for the sump pump and AVD were also dense. 1.2-1.5 million grid elements were generated using ANSYS ICEM-CFD 14.5 with a mixture of tetra and prism elements. The analysis was done using the SST turbulence model of ANSYS CFX14.5, a commercial CFD program. The conditions were as follows: H.W.L 6.0 m, L.W.L 3.5, Qmax 4.000 kg/s, Qavg 3.500 kg/s Qmin 2.500 kg/s. The results of analysis by the vertex angle and velocity distribution are as follows. A sump pump with an Ext E-type AVD was accepted at a high water level. However, further studies are needed for a low water level using the Ext E-type AVD as a base.

Evaluation of the Smoke Characteristics of Some Plastics in an Enclosed Compartment (밀폐된 구획 내 일부 플라스틱류의 연기 특성 평가)

  • Ji-Sun You;Kyeong-Sin Kang;Jae-Sung Lee;Yeong-Jin Chung
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.421-425
    • /
    • 2023
  • The smoke properties of some plastics were investigated, including polymethyl methacrylate (PMMA), polycarbonate (PC), polyvinyl chloride (PVC), and polyacetal. For smoke density, related values of static smoke characteristics were measured using a smoke density tester according to ISO 5659-2. In addition, combustion with and without flame was measured independently. Under the condition of radiant heat of 50 kW/m2 using the flame method, the measured value of the maximum specific optical density (Dm) of smoke showed the lowest value for PMMA (401.26) and the highest value for PVC (1345.04). In addition, PMMA (262.82) was the lowest and PVC (1385.43) was the highest in the measured Dm of smoke under the condition of radiant heat of 50 kW/m2 in the non-flame method. Smoke generation during combustion of the object is significantly affected by the radiant heat flux, and carbonizable plastics showed a higher amount of smoke than non-carbonizable plastics during combustion. Polymers with aromatic groups in the main polymer chain generated a large amount of smoke because a large amount of char was generated due to thermal decomposition.

Observations on the Coastal Ocean Response to Typhoon Maemi at the East Sea Real-time Ocean Buoy (동해 실시간 해양관측 부이로부터 관측한 태풍 매미에 대한 연안해양의 반응 고찰)

  • Nam, Sung-Hyun;Yun, Jae-Yul;Kim, Kuh
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.3
    • /
    • pp.111-118
    • /
    • 2004
  • An ocean buoy was deployed 10 km off Donghae city, Korea at a depth of 130 m to measure meteorological (air pressure, air temperature, wind speed, wind gust, wind direction, relative humidity) and oceanographic data (water properties and currents in the whole column) in real-time. The buoy recorded a maximum wind gust of 25 m/s (10 minutes' average speed of 20 m/s) and a minimum air pressure of 980 hPa when the eye of typhoon Maemi passed by near the Uljin city, Korea at 03:00 on 13 September 2003. The wave height reached maximum of 9 m with the significant wave height of 4 m at 04:00 (1 hour after the passage of Maemi). The currents measured near the surface reached up to about 100 cm/s at 13:00 (10 hours after the passage of Maemi). The mixed layer (high temperature and low salinity) thickness, which was accompanied by strong southward current, gradually increased from 20 m to 40 m during the 10 hours. A simple two layer model for the response to an impulsive alongshore wind over an uniformly sloping bottom developed by Csanady (1984) showed reasonable estimates of alongshore and offshore currents and interface displacement for the condition of typhoon Maemi at the buoy position (x=8.15 km) during the 10 hours.