• Title/Summary/Keyword: 최소 유지 거리

Search Result 89, Processing Time 0.031 seconds

A Study on Radiation Exposure Dose of Patients and Operator during Percutaneous Vertebroplasty (경피적 추체 성형술 시행 시 환자와 시술자의 방사선 피폭선량에 관한 연구)

  • Lee, Jae-Heon;Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.139-144
    • /
    • 2017
  • Percutaneous vertebroplasty (PVP) is increasingly used to treat osteoporotic vertebral fractures, myeloma and osteolytic vertebral metastases. The purpose of this study was to measure the absorbed radiation exposure dose and time during PVP and to assess the possibility of deterministic radiation effects to the operator and patient. The radiation dose and time measure by three pain physicians performed consecutive procedures using the twenty case PVP. Patient's dosimeter placed at the anteroposterior(AP) side was treatment of the vertebra body located in the upper level 2-3 and lateral(LAT) side was flank proximal to C-arm tube of back. Operator's dosimeter placed at the apron outside of upper sternum (thyroid), left chest, lower extremity and apron inside of left chest. Results: Radiation exposure times were $3.6{\pm}0.71min$. Measurements on the Patient radiation dose were AP $121.4{\pm}48.1{\mu}Sv$, LAT side $614.7{\pm}177.1{\mu}Sv$. Operator radiation dose were outside of the lead apron upper sternum $33.7{\pm}7.3{\mu}Sv$, outside of the lead apron chest $49.2{\pm}15.0{\mu}Sv$, outside of the lead apron lower extremity $12.8{\pm}3.8{\mu}Sv$ and inside of the lead apron chest $4.2{\pm}1.4{\mu}Sv$. To escape from the danger of radiation first long distance from the c-arm tube second exposure time reduced second lead apron used fluoroscopy during PVP is more safety patient and operation from the radiation exposure.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

A study on long-term soft tissue changes after superior repositioning of the maxilla (상악골의 수술적 상방이동에 대한 연조직의 장기적 변화에 관한 연구)

  • Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.627-635
    • /
    • 1999
  • Soft tissue changes that occurred between presurgery to 5-years post-surgery in 49 orthognathic surgery patients whose maxillae were moved upward by Le Fort I osteotomy were examined by lateral cephalometric film. The objective of this paper was to document soft tissue changes at long-term follow-up after superior repositioning of the maxilla and to relate soft tissue and hard tissue changes in this group. The results were as follows. 1. On average, soft tissue landmarks in the nose and the upper lip were not changed statistically significantly except superior movement of superior labial sulcus and forward movement of pronasale between presurgery and 5 years postsurgery. 2. Upward and forward movement of the lower lip were found at 5 years postsurgery in comparison with presurgery and genioplasty added this effects. 3. Upper lip length and vertical dimension of upper vermilion didn't show any significant changes, but increase of lower lip length and decrease of vertical dimension of lower vermilion were statistically significant between presurgery and 5 years post-surgery. 4. The decrease of upper incisor exposure and interlabial distance from presurgery to 1 year were continued from 1 year to 5 years and the amount of the decrease was more than that of vertical movement of the maxilla by surgery. 5. Long term changes in soft tissue landmarks from 1 to 5 years postsurgery exceeded hard tissue changes, meaning soft tissue moved down more than skeletal changes.

  • PDF

Spatial Genetic Structure at a Korean Pine (Pinus koraiensis) Stand on Mt. Jumbong in Korea Based on Isozyme Studies (점봉산(點鳳山) 잣나무임분(林分)의 개체목(個體木) 공간분포(空間分布)에 따른 유전구조(遺傳構造))

  • Hong, Kyung-Nak;Kwon, Young-Jin;Chung, Jae-Min;Shin, Chang-Ho;Hong, Yong-Pyo;Kang, Bum-Yong
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.1
    • /
    • pp.43-54
    • /
    • 2001
  • Genetic differentiation of populations is resulted from the environmental and the genetic effects, and the interactions between them. Whereas, the major factors influencing to the genetic differentiation within populations are the gene flow induced by seed or pollen dispersial, the microsite heterogeneity, and the density-dependent distribution of individuals. For the purpose of studying spatial genetic structure and the distribution pattern of Korean pines(Pinus koraiensis), we set up one $100{\times}100m$ plot at a Korean pine stand in Quercus mongolica community on Mt. Jumbong in Korea. To estimate the coefficient of spatial autocorrelation as Moran's index and an analogue, simple block distance, isozyme markers were analyzed in 325 Korean pines. For 11 polymorphic loci observed in 9 enzyme systems, the average percentage of polymorphic loci, the observed and expected heterozygocity were 72.2% 0.200, and 0.251, respectively. It was revealed the excess of homozygotes was observed in the plot, which suggests that here may be more number of consanguineous trees than expected. On the basis of isozyme genotypes observed in this study, 325 trees were classified into 147 groups in which the maximum number of trees for one group was 34. From the distance class of 24-32m, the genetic heterogeneity began to increase. The variation of simple block distance against the growth performance by tree height and diameter also showed the same trend at 24~32m class. According to high fixation index(F=0.204), the spatial genetic structure within a stand, the analysis of the growth performance, and the distribution patterns of identical genotypes, we inferred that the genetic structure of a Korean pine stand in Mt. Jumbong has been maintained rather density-dependent mechanism than the gene flow, such as the pollen dispersial or the heavy input of seeds following the forest gaps. The genetic patchy size was determined between 24~32m, which suggests that the selection of individuals for the ex situ conservation of Korean pine in Mt. Jumbong may be desirable to be made with the spatial distance over 37 meters between trees.

  • PDF

Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients (토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가)

  • Woo, Joong-Yeol;Kim, Joo-Ho;Kim, Joon-Won;Baek, Jong-Geal;Park, Kwang-Soon;Lee, Jong-Min;Son, Dong-Min;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2012
  • Purpose: We evaluated usefulness of abdominal compressor for stereotactic body radiotherapy (SBRT) with unresectable hepatocellular carcinoma (HCC) patients and hepato-biliary cancer and metastatic liver cancer patients. Materials and Methods: From November 2011 to March 2012, we selected HCC patients who gained reduction of diaphragm movement >1 cm through abdominal compressor (diaphragm control, elekta, sweden) for HT (Hi-Art Tomotherapy, USA). We got planning computed tomography (CT) images and 4 dimensional (4D) images through 4D CT (somatom sensation, siemens, germany). The gross tumor volume (GTV) included a gross tumor and margins considering tumor movement. The planning target volume (PTV) included a 5 to 7 mm safety margin around GTV. We classified patients into two groups according to distance between tumor and organs at risk (OAR, stomach, duodenum, bowel). Patients with the distance more than 1 cm are classified as the 1st group and they received SBRT of 4 or 5 fractions. Patients with the distance less than 1 cm are classified as the 2nd group and they received tomotherapy of 20 fractions. Megavoltage computed tomography (MVCT) were performed 4 or 10 fractions. When we verify a MVCT fusion considering priority to liver than bone-technique. We sent MVCT images to Mim_vista (Mimsoftware, ver .5.4. USA) and we re-delineated stomach, duodenum and bowel to bowel_organ and delineated liver. First, we analyzed MVCT images to check the setup variation. Second we compared dose difference between tumor and OAR based on adaptive dose through adaptive planning station and Mim_vista. Results: Average setup variation from MVCT was $-0.66{\pm}1.53$ mm (left-right) $0.39{\pm}4.17$ mm (superior-inferior), $0.71{\pm}1.74$ mm (anterior-posterior), $-0.18{\pm}0.30$ degrees (roll). 1st group ($d{\geq}1$) and 2nd group (d<1) were similar to setup variation. 1st group ($d{\geq}1$) of $V_{diff3%}$ (volume of 3% difference of dose) of GTV through adaptive planing station was $0.78{\pm}0.05%$, PTV was $9.97{\pm}3.62%$, $V_{diff5%}$ was GTV 0.0%, PTV was $2.9{\pm}0.95%$, maximum dose difference rate of bowel_organ was $-6.85{\pm}1.11%$. 2nd Group (d<1) GTV of $V_{diff3%}$ was $1.62{\pm}0.55%$, PTV was $8.61{\pm}2.01%$, $V_{diff5%}$ of GTV was 0.0%, PTV was $5.33{\pm}2.32%$, maximum dose difference rate of bowel_organ was $28.33{\pm}24.41%$. Conclusion: Despite we saw diaphragm movement more than 5 mm with flouroscopy after use an abdominal compressor, average setup_variation from MVCT was less than 5 mm. Therefore, we could estimate the range of setup_error within a 5 mm. Target's dose difference rate of 1st group ($d{\geq}1$) and 2nd group (d<1) were similar, while 1st group ($d{\geq}1$) and 2nd group (d<1)'s bowel_organ's maximum dose difference rate's maximum difference was more than 35%, 1st group ($d{\geq}1$)'s bowel_organ's maximum dose difference rate was smaller than 2nd group (d<1). When applicating SBRT to HCC, abdominal compressor is useful to control diaphragm movement in selected patients with more than 1 cm bowel_organ distance.

  • PDF

Genetic Diversity and Relationship of the Walleye Pollock, Theragra chalcogramma Based on Microsatellite Analysis (Microsatellite marker 분석을 이용한 명태(Theragra chalcogramma) 5 집단의 유전적 다양성 및 유연관계 분석)

  • Dong, Chun Mae;Kang, Jung-Ha;Byun, Soon-Gyu;Park, Kie-Young;Park, Jung Youn;Kong, Hee Jeong;An, Cheul Min;Kim, Gun-Do;Kim, Eun-Mi
    • Journal of Life Science
    • /
    • v.26 no.11
    • /
    • pp.1237-1244
    • /
    • 2016
  • A comprehensive analysis of the genetic diversity and relationship of the cold-water fishery walleye pollock (Theragra chalcogramma), the most abundant economically important fishery resource in the East sea of Korea, has not been carried out, despite its importance in Korea. The present study assessed the genetic diversity and relationship between five walleye pollock populations (Korean population, Russian population, USA population, and Japanese populations) of T. chalcogramma using eight microsatellite DNA (msDNA) markers to provide the scientific data for the preservation and management of the Pollock fishery resource. The results of the analysis of 186 individuals of the Pollock revealed a range of 7.13-10.63 numbers of alleles (mean number of alleles=9.05). The means of observed heterozygosity ($H_O$), expected heterozygosity ($H_E$) were 0.732 and 0.698, respectively. The results of genetic distance, Pairwise $F_{ST}$, UPGMA (UPGMA: un-weighted pair-group method with an arithmetical average) (the phylogenetic tree), PCA (PCA: Principal Coordinate analysis) analysis pointed to significant differences between the Korean population, Russian population, USA population, and Japanese populations, although small (p<0.05). These results shed light on the genetic diversity and relationships of T. chalcogramma and can be utilized for research on the evaluation and conservation of Korean T. chalcogramma as genetic resources.

Locational and Constructional Characteristics of Imrijeong & Palgwae-jeong in Nonsan - Focused on the Relation with Jukrim-Seowon - (논산 임리정(臨履亭)과 팔괘정(八卦亭)의 입지 및 조영 특성 - 죽림서원(竹林書院)과의 관계를 중심으로 -)

  • Lee, Hyun-Woo;Rho, Jae-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.70-81
    • /
    • 2013
  • In this study, the locational and constructional characteristics of Jukrimseowon, pavilion Imrijeong, and Palgwaejeong located in Nonsan, Ganggyung-eup were reviewed and the interrelation of these three places were studied through references including records of those days; Sagyeyonbo(沙溪年譜), Jukrimseowon dorok(竹林書院都錄), Imrijeonggi(臨履亭記), Jukrimseowon Myojeongbi(竹林書院廟庭碑), Namyurok(南遊錄). The result is as follows. Jukrimseowon enshrining Yukhyeon(六賢) is arranged as 'Hongsalmoon-Woisalmoon-Dongjae(憲章堂; Heonjangdang)' and 'LIbrary-Naesammoon(神門; shin moon)-Sau(竹林祠: Jukimsa)', excluding a lecture hall. In case of Sagye Jangsang Kim's Imrijeong(沙溪金長生) and Uam Shiyoel Song(尤庵宋時烈)'s Palgwaejeong respectively constructed 50 meters and 10 meters each away from Jurimseowon, detail designs such as scale, roofs, surface, windows, doors, and tablets as well as its prospect are nearly identified. Especially Taking Imrijeong and Palgwaejeong's locational conditions composed of rocks centered on Jukrimseowon, those are maintain the bilateral symmetry as much as possible and surround the shrine. It appeared that the Jukrimseowon's shrine enshrining Yulgok(栗谷) and Ugye(牛溪) was rebuilt during the reconstruction of auditoriums because of political conditions after the renovation of Kiing Injo and it was called as 'Hwangsanseowon(黃山書院)' with Imrijeong which was a lecture hall. It was an inevitable consequence to keep the bilateral symmetry which is a basic order of auditorium structure by maintaining and using Imrijeong and Palgwaejeong as a lecture hall of the auditorium after the reconstruction at least. Consequently, the desperate attempt to adjust the arrangement and visual imbalance of Imrijeong built with periodical differences and Hwangsanseowon resulted from the construction of shrine was Palgwaejeong built under Monggoibyuk of Hwansan Taken these circumstances together, Jukrimseowon is a 'shrine-centered auditorium' with characteristics of auditorium, constructed by integrating Imrijeong which was used as a lecture hall after the construction of shrine and Palgwaejeong repaired through the reconstruction. The construction of Palgwaejeong and the formative conformity with Imrijeong are assumed as an consequence intended for the compensation of Jukrimseowon's function and role as an auditorium. This study will provide an opportunity to focus on the auditorium and pavilion's complementary function as well as the Confucian and constructional functions by revealing the fact that pavilions were established as a complementary facility for the lecture hall of auditorium.

Validity and Pertinence of Administrative Capital City Proposal (행정수도 건설안의 타당성과 시의성)

  • 김형국
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.2
    • /
    • pp.312-323
    • /
    • 2003
  • This writer absolutely agrees with the government that regional disequilibrium is severe enough to consider moving the administrative capital. Pursuing this course solely to establish a balanced development, however, is not a convincing enough reason. The capital city is directly related to not only the social and economic situation but, much more importantly, to the domestic political situation as well. In the mid-1970s, the proposal by the Third Republic to move the capital city temporarily was based completely on security reasons. At e time, the then opposition leader Kim, Dae-jung said that establishing a safe distance from the demilitarized zone(DMZ) reflected a typically military decision. His view was that retaining the capital city close to the DMZ would show more consideration for the will of the people to defend their own country. In fact, independent Pakistan moved its capital city from Karachi to Islamabad, situated dose to Kashmir the subject of hot territorial dispute with India. It is regrettable that no consideration has been given to the urgent political situation in the Korean peninsula, which is presently enveloped in a dense nuclear fog. As a person requires health to pursue his/her dream, a country must have security to implement a balanced territorial development. According to current urban theories, the fate of a country depends on its major cities. A negligently guarded capital city runs the risk of becoming hostage and bringing ruin to the whole country. In this vein, North Koreas undoubted main target of attack in the armed communist reunification of Korea is Seoul. For the preservation of our state, therefore, it is only right that Seoul must be shielded to prevent becoming hostage to North Korea. The location of the US Armed Forces to the north of the capital city is based on the judgment that defense of Seoul is of absolute importance. At the same time, regardless of their different standpoints, South and North Korea agree that division of the Korean people into two separate countries is abnormal. Reunification, which so far has defied all predictions, may be realized earlier than anyone expects. The day of reunification seems to be the best day for the relocation of the capital city. Building a proper capital city would take at least twenty years, and a capital city cannot be dragged from one place to another. On the day of a free and democratic reunification, a national agreement will be reached naturally to find a nationally symbolic city as in Brazil or Australia. Even if security does not pose a problem, the governments way of thinking would not greatly contribute to the balanced development of the country. The Chungcheon region, which is earmarked as the new location of the capital city, has been the greatest beneficiary of its proximity to the capital region. Not being a disadvantaged region, locating the capital city there would not help alleviate regional disparity. If it is absolutely necessary to find a candidate region at present, considering security, balanced regional development and post-reunification scenario of the future, Cheolwon area located in the middle of the Korean peninsula may be a plausible choice. Even if the transfer of capital is delayed in consideration of the present political conflict between the South and the North Koreas, there is a definite shortcut to realizing a balanced regional development. It can be found not in the geographical dispersal of the central government, but in the decentralization of power to the provinces. If the government has surplus money to build a new symbolic capital city, it is only right that it should improve, for instance, the quality of drinking water which now everyone eschews, and to help the regional subway authority whose chronic deficit state resoled in a recent disastrous accident. And it is proper to time the transfer of capital city to coincide with that of the reunification of Korea whenever Providence intends.

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.