• Title/Summary/Keyword: 최소기준

Search Result 1,578, Processing Time 0.027 seconds

Hydrological Characteristics of the Underground Discharge at Moolgol in Dokdo, Korea (독도 물골 지하유출수의 수문학적 특성)

  • Woo, Nam C.;Lee, Dong Y.;Park, Jong H.;Kim, Yoon B.;Woo, Min S.;Park, Chan H.
    • Economic and Environmental Geology
    • /
    • v.55 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • Whether Dokdo can sustain human habitation or economic life of their own plays an important role to the legal status of the island in the international maritime law. This study reports the hydrological survey results regarding the water resource of the island occurred at Moolgol in Seodo. The amount of underground discharge at Moolgol was estimated at least 1.1 m3/d, conforming the results of previous studies. Based on the oxygen and hydrogen isotope ratios of water, the discharge appeared to originate from precipitation, and about 36% of the daily precipitation moves fast to the Moolgol through the joints developed in the volcanic bedrocks. Quality of the discharged water shows relatively higher concentrations in Cl and NO3 to be used for drinking and domestic purposes, probably affected by the sea spray and waves from surrounding sea and the birds' excretion such as black-tailed gulls.

Safety Identification Lamp Visibility of Micro Cars (초소형전기차의 안전식별등 시인성에 관한 연구)

  • Baek, Seong Chae;Seo, Im Ki;Kim, Jeong Hyun;Park, Je Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.417-425
    • /
    • 2022
  • Interest in micro cars is growing around the world, and policy support for micro cars has been increasing in Korea. It is important to meet minimum safety standards for the operation of micro cars on roads due to concerns around micro car safety and the limited driving range of micro cars. In this study, visibility experiments that included safety identification of micro cars were conducted to try and prevent a decrease in driver reaction time. Safety identification lights were installed to the rear of a micro car, and the visibility and discomfort of the vehicle were evaluated to determine whether the micro car was safe to drive on an expressway. As a result, the installation effect of Micro car which install safety identification lamp was found when joining the point at an acceleration lane of the grade separation intersection, and that light on/off could be effective when entering an expressway. If the micro car operation plan proposed in this study is applied, the safety of micro cars on expressways can be increased by improving the visibility of micro car.

Comparisons of Image Quality and Entrance Surface Doses according to Care Dose 4D + Care kV in Chest CT (Chest CT에서 Care Dose 4D+Care kV에 따른 화질과 입사표면선량 비교)

  • Kang, Eun-Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • This study compared DLP values along with phantom entrance surface doses and the image quality of chest CT scans made using a Care Dose 4D+Care kV System, scans that are made using only the Care Dose 4D function, and scans that are made with changes made by applying 80 kVp, 100 kVp, 120 kVp, and 140 kVp to the Care Dose 4D and tube voltage to search for methods to maintain the highest image quality with minimal patient doses. It was shown that DLP values decreased 6.727% when scans were taken with Chest Care Dose 4D + Care kV semi 100 and 6.481% when scans were taken with Chest Care Dose 4D + Care kV. With Chest Non as a standard, skin surface doses decreased 16.519% when scans were taken with Chest Care Dose 4D + Care kV semi 100 and 15.705% when scans were taken with Chest Care Dose 4D + Care kV. With comparisons of image quality, when comparisons were made with Chest Non, comparisons made of SNR values and CNR values in all scanning conditions including Care Dose 4D + Care kV showed that there were no significant differences at P>0.05. Imaging using Chest Care Dose 4D + Care kV in chest CT showed that exposure doses decreased similarly to result values gained from the best conditions through manual adjustments of kV and mAS, and there were no significant differences in image SNR and CNR. If the Chest Care Dose 4D + Care kV function is used, image quality is maintained and patient exposure to radiation can be reduced.

Satisfaction with Neighborhood Environments for Dog Walking and Exercise (반려견 산책 및 운동을 위한 근린환경 인식 및 만족도 연구)

  • Song, Jin-Gyeoung;Lee, Jeong-Yeon;Lee, Hyung-Sook
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.4
    • /
    • pp.53-62
    • /
    • 2022
  • Animal companionship is gaining popularity in Korea, and interest in dog walking is also increasing as a strategy to maintain the physical and mental health of dogs and dog owners. The purpose of this study was to investigate the perception and satisfaction of dog owners with the neighborhood environments for dog walking and to examine the willingness to pay (WTP) for an off-leash dog park. Of a total of 249 online survey respondents, 47.8% said they take a walk at least once a day and mainly walk around nearby neighborhoods or parks. Respondents showed a high attachment to their dogs and recognized that dog walks help increase physical activity and maintain the health of owners and their dogs. The satisfaction with neighborhood environments, such as attractive views and the connection of walking trails, was low, and there was a high demand for off-leash dog parks. The truncated mean WTP was estimated to be 85,618 Korean Won, and the result of regression analysis and t-test revealed that walking frequency and the satisfaction with dog walking facilities were statistically significant in the WTP. In order to encourage dog walking to promote physical activity and health, more attention needs to be devoted to improving neighborhood environments for dog walking.

Rotational Prism Stitching Interferometer for High-resolution Surface Testing (고해상도 표면 측정을 위한 회전 프리즘 정합 간섭계)

  • In-Ung Song;Woo-Sung Kwon;Hagyong Khim;Yun-Woo Lee;Jong Ung Lee;Ho-Soon Yang
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.3
    • /
    • pp.117-123
    • /
    • 2023
  • The size of an optical surface can significantly affect the performance of an optical system, and high spatial frequency errors have a greater impact. Therefore, it is crucial to measure the surface figure error with high frequency. To address this, a new method called rotational prism stitching interferometer (RPSI) is proposed in this study. The RPSI is a type of stitching interferometer that enhances spatial resolution, but it differs from conventional stitching interferometers in that it does not require the movement of either the mirror tested or the interferometer itself to obtain sub-aperture interferograms. Instead, the RPSI uses a beam expander and a rotating Dove prism to select particular sub-apertures from the entire aperture. These sub-apertures are then stitched together to obtain a full-aperture result proportional to the square of the beam expander's magnification. The RPSI's effectiveness was demonstrated by measuring a 40 mm diameter spherical mirror using a three-magnification beam expander and comparing the results with those obtained from a commercial interferometer. The RPSI achieved surface testing results with nine times higher sampling density than the interferometer alone, with a small difference of approximately 1 nm RMS.

Ordinary Kriging of Daily Mean SST (Sea Surface Temperature) around South Korea and the Analysis of Interpolation Accuracy (정규크리깅을 이용한 우리나라 주변해역 일평균 해수면온도 격자지도화 및 내삽정확도 분석)

  • Ahn, Jihye;Lee, Yangwon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.1
    • /
    • pp.51-66
    • /
    • 2022
  • SST (Sea Surface Temperature) is based on the atmosphere-ocean interaction, one of the most important mechanisms for the Earth system. Because it is a crucial oceanic and meteorological factor for understanding climate change, gap-free grid data at a specific spatial and temporal resolution is beneficial in SST studies. This paper examined the production of daily SST grid maps from 137 stations in 2020 through the ordinary kriging with variogram optimization and their accuracy assessment. The variogram optimization was achieved by WLS (Weighted Least Squares) method, and the blind tests for the interpolation accuracy assessment were conducted by an objective and spatially unbiased sampling scheme. The four-round blind tests showed a pretty high accuracy: a root mean square error between 0.995 and 1.035℃ and a correlation coefficient between 0.981 and 0.982. In terms of season, the accuracy in summer was a bit lower, presumably because of the abrupt change in SST affected by the typhoon. The accuracy was better in the far seas than in the near seas. West Sea showed better accuracy than East or South Sea. It is because the semi-enclosed sea in the near seas can have different physical characteristics. The seasonal and regional factors should be considered for accuracy improvement in future work, and the improved SST can be a member of the SST ensemble around South Korea.

Perception of Science Core Competencies of High School Students who Participated in the 'Skills' based Inquiry Class of the 2015 Revised Science Curriculum (2015 개정 과학과 교육과정의 '기능' 기반 탐구 수업에 참여한 고등학생의 과학과 핵심역량에 대한 인식)

  • Sangyou Park;Wonho Choi
    • Journal of The Korean Association For Science Education
    • /
    • v.43 no.2
    • /
    • pp.87-98
    • /
    • 2023
  • In this study, we investigated the change in science core competency perception of high school students and the reason for change when science inquiry classes were conducted using eight 'skills' of the 2015 revised science curriculum. Fifteen first-year high school students in Jeollanam-do participated in the science inquiry class of this study, and the class was conducted for 20 hours (5 hours a day for four days). The inquiry activities used in the class consisted of four activity stages (research problems, research methods, research results, and conclusions) and each stage was constructed to include at least one 'skill (Problem Recognition, Model Development and Use, Inquiry Design and Performance, Data Collection, Analysis and Interpretation, Mathematical Thinking and Computer Application, Conclusion and Evaluation, Evidence-based Discussion and Demonstration, and Communication)'. As a result of the study, students' perception of the five science core competencies increased statistically significantly at the significance level of 0.01 through inquiry classes and more than 93% of students recognized that their science core competencies improved through the classes. However, since the class of this study was conducted for a small number of students, it is difficult to generalize the effect of the class, and so it is necessary to conduct a quantitative study for many students.

Prediction of Physical Properties and Shear Wave Velocity of the Ground Using the Flat TDR System (Flat TDR 시스템을 이용한 지반의 물리적 특성 및 전단파속도 예측)

  • Jeong, Chanwook;Kim, Daehyeon
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.173-191
    • /
    • 2022
  • In this study, the shear wave velocity of the ground was measured using Flat TDR, and the precision analysis of the measured value and the verification of field applicability were performed. The shear wave velocity measurement value was derived in the field using the piezo-stack combined in the Flat TDR. analyzed. As a result of the experiment, the average value of the change in shear wave speed at the time of grout material injection was 10.15 m/s at the beginning of age, and the average value of the change in shear wave speed after the 7th to 14th days was 65.99 m/s, showing a tendency to increase with age. Also, it was found that dry density and shear wave speed increased as the water content increased on the dry side, and that the dry density and shear wave rate decreased as the water content increased on the wet side as the water content increased. The shear modulus value derived from the field test was confirmed to be a minimum of 17.36 MPa and a maximum of 28.13 MPa, confirming a measurement value similar to the reference value. Through this, it can be seen that the measured value of the shear modulus using Flat TDR is reliable data, and it can be determined that the compaction management of the site can be effectively managed in the future.

Effect of open proximal contact on adjacent tooth and implant (개방된 인접면 접촉이 인접자연치와 임플란트에 미치는 영향)

  • Moon, Sohyun;Kim, Gwangyun;Cho, Seonghun;Song, Joohun;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate how open contacts impact the natural teeth and dental implant prostheses. Materials and Methods: Following criteria were used to select 20 implant crowns with open proximal contacts as the experimental group (Group A): the restorations were delivered in Chosun University Dental Hospital between 2008 and 2018, the restorations are in the posterior region, opposing teeth are fixed dental prostheses, neighboring teeth are sound natural teeth, the patient had been on the maintenance program for at least 3 years. Another 20 implant crowns with closed proximal contacts were selected as the control group (Group B) using the same criteria. Between the two groups, dental caries and food impaction of the neighboring natural teeth and marginal bone-loss of the implants were compared and evaluated. Results: There was no statistically significant difference between Group A and Group B in the occurrence rates of dental caries, food impaction, and marginal bone-loss. The amount of marginal bone-loss, however, revealed statistically significant differences between the two groups, with Group A showing 0.80 ± 0.39 mm loss and Group B showing 1.1 ± 0.43 mm loss. Conclusion: Implant prostheses with open contacts could be clinically considered in select cases as such restorations revealed no harmful effects on neighboring teeth and implant restorations within the perimeters of this study.

A Study of a Pilot Test for a Blasting Performance Evaluation Using a Dry Hole Charged with ANFO (건공화 공법의 발파 성능 평가를 위한 현장 시험에 관한 연구)

  • Lee, Seung Hun;Chong, Song-Hun;Choi, Hyung Bin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.197-208
    • /
    • 2022
  • The existence of shallow bedrock and the desire to use underground space necessitate the use of blasting methods. The standard blasting method under water after drilling is associated with certain technical difficulties, including reduced detonation power, the use of a fixed charge per delay, and decoupling. However, there is no blasting method to replace the existing blasting method. In this paper, a dry hole charged with ANFO blasting is assessed while employing a dry hole pumping system to remove water from the drill borehole. Additional standard blasting is also utilized to compare the blasting performances of the two methods. The least-squares linear regression method is adopted to analyze the blasting vibration velocity quantitatively using the measured vibration velocity for each blasting method and the vibration velocity model as a function of the scaled distance. The results show that the dry hole charged with ANFO blasting will lead to greater damping of the blasting vibration, more energy dissipation to crush the surrounding rock, and closer distances for the allowable velocity of the blasting vibration. Also, standard blasting shows much longer influencing distances and a wider range of the blasting pattern. The pilot test confirms the blasting efficiency of dry hole charged with ANFO blasting.