• Title/Summary/Keyword: 최대층간변위

Search Result 51, Processing Time 0.024 seconds

Inelastic Time History Analysis of a 5-Story RC OMRF Considering Inelastic Shear Behavior of Beam-Column Joint (보-기둥 접합부 비탄성 전단거동을 고려한 5층 철근콘크리트 보통모멘트골조의 비탄성 시간이력해석)

  • Kang, Suk-Bong;Kim, Tae-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.633-641
    • /
    • 2012
  • In this study, the effects of the inelastic shear behavior of beam-column joint on the response of RC OMRF are evaluated in the inelastic time history analysis. For an example, a 5-story structure for site class SB and seismic design category C was designed in accordance with KBC2009. Bending moment-curvature relationship for beam and column was evaluated using fiber model and bending moment-rotation relationship for beam-column joint was calculated using simple and unified joint shear behavior model and moment equilibrium relationship. The hysteretic behavior was simulated using three-parameter model suggested in IDARC program. The inelastic time history analysis with PGA for return period of 2400 years showed that the model with inelastic beam-column joint yielded smaller maximum base shear force but nearly equivalent maximum roof displacement and maximum story drift as those obtained from analysis using rigid joint. The maximum story drift satisfied the criteria of KBC2009. Therefore, the inelastic shear behavior of beam-column joint could be neglected in the structural design.

Damping and Isolation Performance of Steel Structure (철골 구조물의 제진 및 면진성능)

  • Yun, Hyun-Do;Park, Wan-Shin;Han, Byung-Chan;Hwang, Sun-Kyoung;Lee, Giu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.221-230
    • /
    • 2004
  • In this paper, the dynamic response of a multi-story steel moment resisting frame equipped with viscoelastic dampers or lead rubber bearing type isolators subjected to seismic loads is investigated analytically. The objective of this study is to find the best location of viscoelastic dampers by the maximum stress method and maximum story drifts method from structure analysis. Also, a secondary objective of the study is to compare the member force, combined stress, and natural period of the structure retrofitted with viscoelastic dampers or lead rubber bearing type isolators to find effective vibration control method.

Non-Prismatic Beam Element for Beams with RBS Connection (RBS 연결부를 갖는 보에 대한 부등 단면 보 요소)

  • Kim, Kee Dong;Ko, Man Gi;Hwang, Byoung Kuk;Pae, Chang Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.6 s.73
    • /
    • pp.833-846
    • /
    • 2004
  • This study presents a non-prismatic beam element for modeling the elastic behavior of steel beams, which have the post-Northridge connections in steel moment frames. The elastic stiffness matrix, including the shear effects for non-prismatic members with reduced beam section (RBS) connection, is in closed form. A simplified approach is also suggested, which uses a prismatic beam element to model beams with the RBS connection. This method can estimate quiteexactly the maximum story drift ratios of frames with the RBS connection. The effects of reduced beam section connection on the elastic stiffness of steel moment frames were investigated. The selection of a proper model to account for deformations at the joint might have a more important role in estimating the maximum story drift ratios of frames with better accuracy than the RBS cutouts.

Prototype Development and Experimentation to Improve the Seismic Performance of Curtain walls (커튼월의 내진성능 향상을 위한 시제품 개발 및 실험)

  • Min, Byoung jun;Won, Jeong hun;Jeon Jin woo;Kang, Hyun Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.4
    • /
    • pp.14-24
    • /
    • 2023
  • The purpose of this study is to develop a prototype curtain wall with improved seismic performance and to verify the seismic performance by conducting an inter-floor displacement test. To this end, a prototype of the curtain wall was manufactured and a displacement similar to the earthquake load was induced, and then the damaged state of the curtain wall was checked. As a result of the first test, the frame and glass of the curtain wall were not damaged, but the Weather Sealant was partially damaged. As a result of the second test, there was no problem of glass breakage in seismic class (special), seismic class (I), seismic class (II), and AAMA 501.6. Through this experiment, the seismic performance of the curtain wall prototype was verified.

Member Sizing Optimization for Seismic Design of the Inverted V-braced Steel Frames with Suspended Zipper Strut (Zipper를 가진 역V형 가새골조의 다목적 최적내진설계기법)

  • Oh, Byung-Kwan;Park, Hyo-Seon;Choi, Se-Woon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.6
    • /
    • pp.555-562
    • /
    • 2016
  • Seismic design of braced frames that simultaneously considers economic issues and structural performance represents a rather complicated engineering problem, and therefore, a systematic and well-established methodology is needed. This study proposes a multi-objective seismic design method for an inverted V-braced frame with suspended zipper struts that uses the non-dominated sorting genetic algorithm-II(NSGA-II). The structural weight and the maximum inter-story drift ratio as the objective functions are simultaneously minimized to optimize the cost and seismic performance of the structure. To investigate which of strength- and performance-based design criteria for braced frames is the critical design condition, the constraint conditions on the two design methods are simultaneously considered (i.e. the constraint conditions based on the strength and plastic deformation of members). The linear static analysis method and the nonlinear static analysis method are adopted to check the strength- and plastic deformation-based design constraints, respectively. The proposed optimal method are applied to three- and six-story steel frame examples, and the solutions improved for the considered objective functions were found.

A Study on Hybrid Wall System on Connection Type of Coupling Beam (커플링 보의 접합방식에 따른 복합 벽체 시스템에 관한 연구)

  • Yun, Hyun-Do;Park, Wan-Shin;Han, Byung-Chan;Yun, Yeo-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.201-208
    • /
    • 2003
  • The Hybrid Wall System(HWS) building composed of center core reinforced concrete walls and exterior steel frame has open space around the center core walls. It is necessary to develop design methodologies for the HWS building that the coupled shear walls withstand the most of lateral load and expect the most energy dissipation at the coupling beams and at wall foots. Major factors considered in this paper are connection type of coupling beams and scale of story. The studies of the system are investigated in terms of shear force, overturning moment, maximum lateral displacement, story drift ratio, and dynamical characteristics under the action of vertical and lateral forces such as wind and seismic loads.

Dynamic Behavior of 2D 8-Story Unbraced Steel Frame with Partially Restrained Composite Connection (합성반강접 접합부를 갖는 2차원 8층 비가새 철골골조의 동적거동)

  • Kang, Suk Bong;Lee, Kyung Taek
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.5
    • /
    • pp.503-513
    • /
    • 2007
  • The seismic responses of a building are affected by the connection characteristics that have effects on structural stiffness. In this study, push-over analysis and time history analysis were performed to estimate structural behavior of 2D eight-story unbraced steel structures with partially restrained composite connections using a nonlinear dynamic analysis program. Nonlinear $M-{\theta}$characteristics of connection and material inelastic characteristics of composite beam and steel column were considered. The idealization of composite semi-rigid connection as fully rigid connection yielded an increase in initial stiffness and ultimate strength in the push-over analysis. In time history analysis, the stiffness and hysteretic behavior of connections have effects on base-shear force, maximum story-drift and maximum moment in beams and columns. For seismic waves with PGA of 0.4 g, the structure with the semi-rigid composite connections shows the maximum story-drift with less than the life safety criteria by FEMA 273 and no inelastic behavior of beam and column, whereas in the structure with rigid connections, beams and columns have experienced inelastic behaviors.

Cyclic Testing of Bracket and WUF-B Type Weak-Axis Steel Moment Connections (브라켓 및 WUF-B 형식 철골모멘트골조 약축접합부 내진성능평가)

  • Lee, Kang Min;Jeong, Hee Taek;Yoon, Seok Ryong;Lee, Eun Mo;Oh, Kyung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2008
  • There has been much focus on the strong axis steel moment connections after the Northridge earthquake in 1994. However, research studieson the seismic behavior of weak axis moment connections could be hardly found despite the fact that these connection details have been frequently used as seismic details of MRF in Korea. Therefore, the objective of this research is to provide better knowledge on the seismic behavior of weak-axis steel moment connections, which can be widely applicable to many structures with similar characteristics. For this purpose, an experimental program was designed and performed with twotypes of weak-axis steel moment connections, namely the bracket type and WUF-B type, based on the survey of existing field data and literatures. Using the experimental results obtained from the quasi-static cyclic testing of these specimens, structural performances of the joints such as hysteretic curves, maximum strength capacities and the strain of reinforced bars were investigated. From the test results, the bracket-type connection was shown to have more than a 5% story drift capacity, compared with the WUF-B type connection's 4%. These specimens were also shown to have higher strength capacities than the nominal design strength. The bracket-type connection showed a slow strength degradation after maximum strength was researched. However,the WUF-B type connection showed a rapid strength degradation that caused brittle behavior.

Experiments of the Lateral Loading Capacity of Exterior Joints of Non-seismically Designed RC Frames in Korea (비내진설계된 우리나라 RC 외부 접합부의 횡저항 능력에 관한 실험)

  • Lee, Young-Wook;Park, Hyeong-Kyeon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.29-36
    • /
    • 2010
  • To investigate the cyclic characteristics of exterior joints in RC frame buildings which are typically used after 1988, 70% scaled T-shaped beam-column subassemblies were designed and tested with a displacement control that is composed of 9 steps, until 3.5% story drift was reached. Axial forces are applied to columns during the experiment to simulate a real situation. The results show that the non-seismic detailed specimens failed before reaching 0.85% story drift, and their strengths are less than 0.85 times the nominal flexural strength which beam or columns should reach. The relationship of principal stress and story drift of exterior joints is similar to the one that Priestly proposed.

Seismic Performance of Low-rise Piloti RC Buildings with Eccentric Core (편심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능)

  • Kim, Sung-Yong;Kim, Kyung-Nam;Yoon, Tae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.490-498
    • /
    • 2020
  • In this study, the seismic performance of low-rise piloti buildings with eccentric core (shear wall) positions was analyzed and reviewed. A prototype was selected among constructed low-rise piloti buildings with eccentric cores designed based on KBC2005. The seismic performance of the building showed plastic behavior in the X-direction and elastic behavior in the Y-direction. The inter-story drift is larger than that of a concentric core case and has the maximum allowed drift ratio. The displacement ratio of the first story is much larger than that of upper stories, and the frame structure in the first story is vulnerable to lateral force. Therefore, low-rise piloti buildings with eccentric cores need to have less lateral displacement, as well as reinforcement of the lateral resistance capacity in seismic design and seismic retrofit.