• Title/Summary/Keyword: 최대진폭

Search Result 263, Processing Time 0.023 seconds

Improving Wave Propagation Performance of an Ultrasonic Waveguide for Heat Isolation (열 차단용 초음파 도파관의 전파성능 향상 연구)

  • 최인석;전한용;김인수;김진오
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.545-553
    • /
    • 2003
  • This paper is concerned with protecting piezoelectric transducers used in an ultrasonic flowmeter from the high temperature of hot fluid in a pipe by using a waveguide and with improving the propagation of ultrasonic longitudinal vibration in the waveguide. Waveguide material has been chosen for efficient insulation of heat transferred in the waveguide, and the minimum length of the waveguide for protecting piezoelectric transducer has been estimated. Forced response of the longitudinal vibration in a uniform circular rod has been obtained and the length of the waveguide has been selected for maximum amplitude. Longitudinal vibration response of a conically-tapered rod excited at a natural frequency has been obtained to confirm that wave motion is amplified as the cross-sectional size of the waveguide decreases along the axial direction. The fact that dispersion of a pulse wave in a waveguide is reduced as the cross-sectional radius is decreased has been examined theoretically and confirmed experimentally by using a single-rod waveguide. A bundle-type waveguide has proven to be a practical one through the evaluation of the wave propagation performance.

Performance Evaluation of VSDA Blind Equalization Algorithm for 16-QAM Signal (16-QAM 신호에 대한 VSDA 블라인드 등화 알고리즘의 성능 평가)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.85-91
    • /
    • 2014
  • This paper relates with the VSDA (Variable stepsize Square contour Decision directed Algorithm) adaptive equalization algorithm that is used for the minimization of the intersymbol interference due to the distortion which occurs in the time dispersive channel for the transmission of 16-QAM signal.. In the conventional SCA, it is possible to compensates the amplitude and phase in the received signal that are mixed with the intersymbol interference by the constellatin dependent constant by using the 2nd order statistics of the transmitted signal. But in the VSDA, it is possible to the increasing the equalization performance by adding the concept of distance adjusted approach for constellation matching and the cost function of decision directed. We compare the performance of VSDA and SCA algorithm by the computer simulation. For this, the equalizer output signal constellation, residual isi, maximum distortion and MSE were used in the performace index. As a result of computer simulation, the VSDA algorithm has better than the SCA in convergence speed, but it gives nearly same equalization performance in other index.

Respiratory Effort Monitoring Using Pulse Transit Time in Human (인체에서 맥파전달시간을 이용한 호흡노력 모니터링)

  • 정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.485-489
    • /
    • 2002
  • In this study. respiratory efforts were monitored by the change of pulse transit time (PTT) which is related with the arterial pressure PTT is the time interval between the peak of R wave in ECG and the maximal slope point of photoplethysmogram(PPG). Biosignals, ECG and finger photoplethysmogram(PPG), were converted to digital data, and PTT was evaluated in personal computer with every heart beat. Results were presented as a graph using spline interpolation. The software was implemented in C$\^$++/ as a window-based application program. PTT was periodically changed according to airflow in resting respiration. In the resting respiration, PTT was changed according to the respiratory cycle. The amplitude of PTT fluctuation was increased by deep respiration, and increased by partial airway obstruction. These results suggest that PTT is responsible to respiratory effort which could be evaluated by the pattern of PTT change. And it is expected that PTT could be applied in the monitoring of respiratory effort by noninvasive methods, and is very useful method for the evaluation of respiratory distress.

The Application of Ultrasonic Spectroscopy System for Phase Transition of Liquid Crystal (액정의 상전이 측정에 대한 초음파 spectroscopy 시스템의 적용)

  • Kim, Jeong-Koo;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.31-35
    • /
    • 2004
  • A new measuring system for ultrasonic spectroscopy was constructed, utilizing PVDF [poly(vinylidene fluoride)] polymer films as wideband transducers. In a test of its performance, this measuring system was successfully applied to study of the nematic-isotropic phase transition in MBBA(p-methoxybenzylidene-p-n-butylan iline) liquid crystal. We could be confirmed that the phase transition in MBBA is $47^{\circ}C$, which is agree with the exciting optical method. The dependence of frequency on the phase transition was not observed, and but Maximum ultrasonic amplitude is measured for the resonance frequency 2MHz in PVDF transducers, These results shows that the spectroscopy with PVDF transducers takes advantage of studying the transient phenomena. When our apparatus is applied in medical purposes, It will be possible diagnostic for sickle-cell anemia and arterial sclerosis.

  • PDF

Analysis of Motion of Batoid Fins for Thrust Generation by Using Fluid-Structure Interaction Method (추진력 생성을 위한 가오리 날개 짓의 유체-구조연성 수치해석)

  • Kwon, Dong-Hyun;Lee, Jong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1575-1580
    • /
    • 2010
  • Recently, the development of bio-mimetic underwater vehicles that can emulate the characteristic movements of marine fish and mammals has attracted considerable attention. In this study, the motion of the batoid (i.e., cownose ray) fin that facilitates excellent cruising and maneuvering during underwater movement has been studied. The velocity achieved and distance covered with each fin movement are numerically studied. A fluid-structure interaction method is used to perform 3D time-dependent numerical analysis, wherein an adaptive mesh is employed to account for the large deformation of a fin interacting with a fluid. The results of a preliminary study show that the thrust of a ray fin is highly dependent on the frequency. Further, once the fin amplitude required for generating a given thrust is evaluated for the conditions experienced by an actual ray, the frequency and amplitude values for achieving better thrust are determined.

Rising Tendencies of both Tidal Elevation and Surge Level at the Southwestern Coast (서남해안의 해수면 상승과 해일고 증가 경향)

  • Kang, Ju-Whan;Park, Seon-Jung;Park, Min-Won
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.1
    • /
    • pp.14-24
    • /
    • 2008
  • Recently, rising tendency of high water level is detected at southwestern coast. The result of harmonic analysis shows increasing trend of mean sea level, decreasing trend of the amplitudes of semi-diurnal tidal constituents, and increase of Sa tidal constituent, therefore, additional increase of high water level at Summer season. It shows also that maximum surge level has increased greatly, according to the frequent visit of big typhoon such as RUSA and MAEMI. Considering the correspondence of Sa and typhoon period, namely July${\sim}$September, extraordinary high water level would be more probable. Especially, Mokpo and Jeju would be considered to have many chances of extraordinary high water level in the future.

Analysis of the Fracture Behavior of Plate-type Piezoelectric Composite Actuators by Acoustic Emission Monitoring (음향방출법을 이용한 평판형 압전 복합재료 작동기의 파괴거동 해석)

  • Woo, Sung-Choong;Goo, Nam-Seo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.220-230
    • /
    • 2006
  • Fracture behavior of a monolithic PZT and a plate-type piezoelectric composite actuator (PCA) has been investigated under a bending load at three points by an acoustic emission (AE) monitoring. AE signal from a monolithic PZT at the maximum bending load shows the characteristics of high amplitude and long duration with a low frequency band of $100{\sim}230kHz$ which is confirmed by fast Fourier transform (FFT). For a PCA, it is concluded that AE signals with high amplitude over 80dB and low dominant frequency band of $170{\sim}223kHz$ emitted in the stage I are due to the brittle fracture in the PZT layer and the delamination between the PZT layer and the adjacent fiber composite layer. Based on the above analysis of AE behavior and damage observations with an optical microscopy and a scanning electron microscopy, AE characteristics related to fracture behavior of asymmetrically laminated PCA have been elucidated.

Consideration of the Effect according to Variation of Material and Respiration in Cone-Beam CT (Cone-Beam CT에서 물질 및 호흡 변화가 영상에 미치는 영향에 대한 고찰)

  • Na, Jun-Young;Kim, Jung-Mi;Kim, Dae-Sup;Kang, Tae-Young;Baek, Geum-Mun;Kwon, Gyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • Purpose: Image Guided Radiation Therapy (IGRT) has been carried out using On-Board Imager system (OBI) in Asan Medical Center. For this reason, This study was to analyze and evaluate the impact on Cone-Beam CT according to variation of material and respiration. Materials and Methods: This study was to acquire and analyze Cone-Beam CT three times for two material: Cylider acryl (lung equvalent material, diameter 3 cm), Fiducial Marker (using clinic) under Motion Phantom able to adjust respiration pattern randomly was varying period, amplitude and baseline vis-a-vis reference respiration pattern. Results: First, According to a kind of material, when being showed 100% in the acryl and 120% in the Fiducial Marker under the condition of same movement of the motion phantom. Second, According to the respiratory alteration, when being showed 1.13 in the baseline shift 1.8 mm and 1.27 in the baseline shift 3.3 mm for acryl. when being showed 1.01 in 1 sec of period and 1.045 in 2.5 sec of period for acryl. When being showed 0.86 in 0.7 times the standard of amplitude and 1.43 in 1.7 times the standard of amplitude for acryl. when being showed 1.18 in the baseline shift 1.8 mm and 1.34 in the baseline shift 3.3 mm for Fiducial Marker. when being showed 1.0 in 1 sec of period and 1.0 in 2.5 sec of period for Fiducial Marker. When being showed 0.99 in 0.7 times the standard of amplitude and 1.66 in 1.7 times the standard of amplitude for Fiducial Marker. Conclusion: The effect of image size of CBCT was 20% in the case of Fiducial marker. The impact of changes in breathing pattern was minimum 13% - maximum 43% for Arcyl, min. 18% - max. 66% for Fiducial marker. This difference makes serious uncertainty. So, Must be stabilized breathing of patient before acquiring CBCT. also must be monitored breathing of patient in the middle of acquire. If you observe considerable change of breathing when acquiring CBCT. After Image Guided, must be need to check treatment site using fluoroscopy. If a change is too big, re-acquiring CBCT.

  • PDF

Design and Implementation of Multifunction 2-Channel Receiver for 3 Dimensional Phased Array Radar (3차원 위상배열 레이다용 다기능 2채널 수신기 설계 및 제작)

  • 강승민;양진모;송재원
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.9
    • /
    • pp.1-12
    • /
    • 1998
  • We have implemented receiver for a 3 Dimensional Phased-Array Radar detecting the azimuth angle, the altitude, the range of a target on real time. This system consists of high frequency module, which protects receiver and controls sensitivity, intermediate frequency module, monopulse detector, IQ phase detector, AGC controller. A two-channel receiver with same function is implemented for increasing accuracy of target altitude data by amplitude comparison monopulse method. The TSS sensitivity of the receiver is -98dBm. The bandwidth of the receiver is 500 MHz. We can control the system gain manually by 100 dB when be AGC off. The gain and phase unbalance of two channels is 5 dB and 30 degree, respectively. The image rejection rate of the IQ detector is 30 dB. We used duroid substrate and package- type device.

  • PDF

An Experimental Study for the Liquefaction Resistance Strength of Saturated Sand Using Real Earthquake Loading (실지진하중을 이용한 포화사질토의 액상화 저항강도에 관한 실험적 연구)

  • 심재욱;박근보;최재순;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.329-337
    • /
    • 2002
  • Based on the equivalent uniform stress concept presented by Seed and Idriss, sinusoidal cyclic loads which simplified the earthquake loads have been applied in evaluating the liquefaction resistance strength experimentally. However, the liquefaction resistance strength of soil based on the equivalent uniform stress concept can not exactly reflect the dynamic characteristics of the irregular earthquake motion. In this study, the criterion of the liquefaction resistance strength was determined by applying real earthquake loading to the cyclic triaxial test. From the test results, relationships between liquefaction behaviors of saturated sand and earthquake characteristics such as magnitude or time-duration were determined. Magnitude scaling factors to determine the soil liquefaction resistance strength in seismic design were also proposed.