• Title/Summary/Keyword: 최대제어력

Search Result 174, Processing Time 0.032 seconds

Brittle rock property and damage index assessment for predicting brittle failure in underground opening (지하공동의 취성파괴 예측을 위한 암석물성 및 손상지수 평가)

  • Lee, Kang-Hyun;Bang, Joon-Ho;Kim, Jin-Ha;Kim, Sang-Ho;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.327-351
    • /
    • 2009
  • Laboratory tests are performed in this paper to investigate the brittle failure characteristics of over-stressed rocks taken in deep depth. Also, numerical simulation performed using that the so-called CWFS(Cohesion Weakening Frictional Strengthening) model is known to predict brittle failure phenomenon reasonably well. The most typical rock types of Korean peninsula - granite and gneiss - were used for testing. Results of uniaxial compression tests showed that the crack initiation stress was about 41 % to 42% of the uniaxial compressive strength regardless of rock types, where as, the crack damage stress of granite was about 75%, and that of gneiss was about 97%. Through the damage-controlled test, strength parameters of each rock were obtained as a function of damage degree. After the peak, the crack damage stress and the maximum stress were decreased, The cohesion was decreased and the friction angle was increased with increase of rock damage. Before reaching the peak, the elastic modulus was slightly increased, while decreased after the peak. Poisson's ratio was increased as the damage of rock proceeds. Comparison of uniaxial compression tests and damage-controlled tests shows the crack initiation stress estimated from the damage-controlled test fluctuated within the range of crack initiation stress obtained from the uniaxial compression test; the crack damage stress was less than that estimated from the uniaxial compression test. In order to predict the critical depth that brittle failure occurs, numerical simulations using the CWFS model were performed for an example site. Material parameters obtained from the laboratory tests mentioned above were used for CWFS simulation. Comparison between the critical depth predicted from the numerical simulation using the CWFS model and that predicted by using the damage index proposed by Martin et al.(l999), showed that critical depth cannot be reasonably predicted by the currently used damage index except for circular tunnels. A modified damage index was proposed by the author which takes the shape of tunnels other than circular into account.

Comparisons of Soil Water Retention Characteristics and FDR Sensor Calibration of Field Soils in Korean Orchards (노지 과수원 토성별 수분보유 특성 및 FDR 센서 보정계수 비교)

  • Lee, Kiram;Kim, Jongkyun;Lee, Jaebeom;Kim, Jongyun
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.401-408
    • /
    • 2022
  • As research on a controlled environment system based on crop growth environment sensing for sustainable production of horticultural crops and its industrial use has been important, research on how to properly utilize soil moisture sensors for outdoor cultivation is being actively conducted. This experiment was conducted to suggest the proper method of utilizing the TEROS 12, an FDR (frequency domain reflectometry) sensor, which is frequently used in industry and research fields, for each orchard soil in three regions in Korea. We collected soils from each orchard where fruit trees were grown, investigated the soil characteristics and soil water retention curve, and compared TEROS 12 sensor calibration equations to correlate the sensor output to the corresponding soil volumetric water content through linear and cubic regressions for each soil sample. The estimated value from the calibration equation provided by the manufacturer was also compared. The soil collected from all three orchards showed different soil characteristics and volumetric water content values by each soil water retention level across the soil samples. In addition, the cubic calibration equation for TEROS 12 sensor showed the highest coefficient of determination higher than 0.95, and the lowest RMSE for all soil samples. When estimating volumetric water contents from TEROS 12 sensor output using the calibration equation provided by the manufacturer, their calculated volumetric water contents were lower than the actual volumetric water contents, with the difference up to 0.09-0.17 m3·m-3 depending on the soil samples, indicating an appropriate calibration for each soil should be preceded before FDR sensor utilization. Also, there was a difference in the range of soil volumetric water content corresponding to the soil water retention levels across the soil samples, suggesting that the soil water retention information should be required to properly interpret the volumetric water content value of the soil. Moreover, soil with a high content of sand had a relatively narrow range of volumetric water contents for irrigation, thus reducing the accuracy of an FDR sensor measurement. In conclusion, analyzing soil water retention characteristics of the target soil and the soil-specific calibration would be necessary to properly quantify the soil water status and determine their adequate irrigation point using an FDR sensor.

Design and simulation of hydraulic system for launch vehicle holding device (우주발사체 지상고정장치 유압시스템 설계 및 해석)

  • Kim, Dae Rae;Yang, Seong Pil;Lee, Jaejun;Kim, Bum Suk;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1087-1094
    • /
    • 2016
  • The responsibility of the vehicle holding device (VHD) is to hold the launch vehicle while it is stayed on launch pad and release the holding mechanism to allow a lift-off of launch vehicle at a moment of lift-off. During a release of the holding mechanism, in order to prevent the Ka doing a doing a doing mode which is vertical oscillation of entire liquid propellant and very severe for vehicle structure, gradual release of holding force is required. Also, a release operation of all 4 VHD should be synchronized very precisely. In this study, to comply the "gradual release and synchronized operation requirement", concept of VHD hydraulic system using an accumulator, pyro valve and orifice to control speed of hydraulic cylinder is proposed instead of using complicated hydraulic components. Then through multi-body dynamic analysis and computational hydraulic analysis, a size of orifice to meet a target speed of hydraulic cylinder is calculated. Through this study, simple and reliable VHD hydraulic system complying requirements is designed.

Isolation and Morphological Characterization of Ttichoderma harzianum SJG-99721, a Powerful Biocontrol Agent (길항작용을 나타내는 Trichoderma harzianum SJG-99721의 분리 및 형태학적 특징)

  • 이호용;민봉희
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.2
    • /
    • pp.130-135
    • /
    • 2002
  • Species of Genus Trichoderma are commercially applied as biological control agents against fungal Pathogens. A powerful biocontrol agent, Trichoderma sp. SJG-99721 was isolated from 305 isolates by morphological characters, chitinase activities and antifungal activities against Phytophthora capsiei. The isolate was identified as Trichoderma harzianum from various features such as growth rate at $27^\circ{C}$, significant growth ratio of $27^\circ{C}$ to $17^\circ{C}$, amount of aerial mycelium, types of branching: system, and disposition patterns of phialide and phialospore. Trichoderma harzianum SJG-99721 have been shown to act as a powerful biological agent against fungal phytopathogens; Botrytis cinerea, Rhizoctonia solani, Phytophthora cryptogea, Phytophthora capsiei, Sclerotinia sclerotiorum, Mycoshaerella melonis, Alternaria sotani, Fusarium oxysporum, Collectotrichum gloesporioodes, Alternaria alternata, Phythium ultimum, Phytophthora drechsleri, Pyricularia grisea.

Retail-Store Type Digital Signage Solution Development And Usability Test Using Android Mini PC (안드로이드 미니PC를 이용한 Retail-Store형 디지털사이니지 솔루션 개발 및 사용성 테스트)

  • Lim, Jungtaek;Shin, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.4
    • /
    • pp.29-44
    • /
    • 2015
  • Digital Signage, a way of advertising or delivering information to viewers through digital displays, has expanded from being just an advertising channel in public places. Recently, it has become widely prevalent in restaurants and retail stores. Despite its wide expansion, digital signage is limited to specific usages and services and the devices it uses are also quite expensive. This study introduces a stick-type digital signage product that operates on Android OS, which addresses all the weaknesses of digital signage with much more reasonable pricing and stable operation. For stability, performance tests were executed on the hardware and applications. The results for hardware performance were extremely promising, as each scenario's maximum performance results, measured by Load Runner programs, reached target indexes. Also, as a result of the usability test, all participants, including non-digital signage system users (novices), were able to easily learn all the tasks. As a result of user satisfaction survey, positive responses were exhibited for ease of learning and usability (LEU), helpfulness and problem solving capabilities (HPSC), affective aspect and multimedia properties (AAMP), commands and minimal memory load (CMML), and control and efficiency (CE).

Assessment of the Damage in High Performance Fiber-Reinforced Cement Composite under Compressive Loading Using Acoustic Emission (AE기법에 의한 압축력을 받는 고인성 섬유보강 시멘트 복합체의 손상 평가)

  • Kim, Sun-Woo;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.589-597
    • /
    • 2009
  • High Performance Fiber-reinforced Cement Composite (HPFRCC) shows the multiple crack and damage tolerance capacity due to the interfacial bonding of the fibers to the cement matrix. For practical application, it is needed to investigate the fractural behavior of HPFRCC and understand the micro-mechanism of cement matrix with reinforcing fiber. This study is devoted to the investigation of the AE signals in HPFRCC under monotonic and cyclic uniaxial compressive loading, and total four series were tested. The major experimental parameters include the type and volume fraction of fiber (PE, PVA, SC), the hybrid type and loading pattern. The test results showed that the damage progress by compressive behavior of the HPFRCC is a characteristic for the hybrid fiber type and volume fraction. It is found from acoustic emission (AE) parameter value, that the second and third compressive load cycles resulted in successive decrease of the amplitude as compared with the first compressive load cycle. Also, the AE Kaiser effect existed in HPFRCC specimens up to 80% of its ultimate strength. These observations suggested that the AE Kaiser effect has good potential to be used as a new tool to monitor the loading history of HPFRCC.

An Experimental Study on the Mechanical Properties of HPFRCCs Reinforced with the Micro and Macro Fibers (마이크로 및 매크로 섬유에 의해 보강된 고인성 시멘트 복합재료의 역학적 특성에 관한 실험적 연구)

  • Kim Moo-Han;Kim Jae-Hwan;Kim Yong-Ro;Kim Young-Duck
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.263-271
    • /
    • 2005
  • HPFRCC(High Performance Fiber Reinforced Cementitious Composite) is a class of FRCCs(Fiber Reinforced Cementitious Composites) that exhibit multiple cracking. Multiple cracking leads to improvement in properties such as ductility, toughness, fracture energy, strain hardening, strain capacity, and deformation capacity under tension, compression, and bending. These improved properties of HPFRCCs have triggered unique and versatile structural applications, including damage reduction, damage tolerance, energy absorption, crack distribution, deformation compatibility, and delamination resistance. These mechanical properties of HPFRCCs become different from the kinds and shapes of used fiber, and it is known that the effective size of fiber in macro crack is different from that in micro crack. This paper reports an experimental findings on the mechanical properties of HPFRCCs reinforced with the micro fiber(PP50, PVA100 and PVA200) and macro fiber(PVA660, SF500). Uniaxial compressive tests and three point bending tests are carried out in order to compare with the mechanical properties of HPFRCCs reinforced with micro fibers or hybrid fibers such as compressive strength, ultimate bending stress, toughness, deformation capacity and crack pattern under bending, etc.,

Evaluation of EGR applicability for NOx reduction in lean-burn LPG direct injection engine (초희박 LPG 직접분사식 엔진에서 질소산화물 저감을 위한 배기재순환 적용성 평가)

  • Park, Cheolwoong;Cho, Seehyeon;Kim, Taeyoung;Cho, Gyubaek;Lee, Janghee
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.22-28
    • /
    • 2015
  • In order to keep the competitiveness of LPG fuel for transportation fuel, the difference in fuel consumption with gasoline and cost for an aftertreatment system should be reduced with continuous development of technology for LPG engine. In the present study, spray-guided type direct injection combustion system, whose configuration is composed of direct injector in the vicinity of spark plug, was employed to realize stable lean combustion. A certain level of nitrogen oxides($NO_x$) emits due to a locally rich mixture regions in the stratified mixture. With the application of EGR system for the reduction of $NO_x$, 15% of $NO_x$ reduction was achieved whereas fuel consumption and hydrocarbon emission increased. By the application of EGR, the combustion speed reduced especially appeared at initial flame development period and peak heat release rates and increasing rates for heat release rate decreased as EGR rate increased due to the dilution effect of intake air.

Effect of DC bias on structure of hydrogenated amorphous silicon and microcrystalline silicon

  • 이윤정;주성재;임승현;윤의준
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.84-84
    • /
    • 2000
  • 수소화된 비정질 실리콘(a-Si:H)과 미세결정질 실리콘 ($\mu$c-Si:H)은 저온.건식 공정인 PECVD로 값싼 유리 기판을 사용하여 넓은 면적에 증착이 가능하다는 큰 장점으로 인해 광전소자(photovoltaic device)와 박막 트랜지스터(TFTs)등에 폭넓게 응용되어 왔으며 최근에는 nm 크기의 실리콘 결정(nc-Si)에서 가시광선 영역의 발광 현상이 발견됨에 따라 광소자로서의 특성을 제어하기 위해서는 성장 조건과 공정 변수에 따른 구조 변화에 대한 연구가 선행되어야 한다. 본 연구에서는 UHV-ECR-PECVD 법을 이용하여 H2로 희석된 SiH4로부터 a-Si:H과 $\mu$c-Si:H를 증착하였다. 그림 1은 SiH4 20sccm/H2 50sccm/25$0^{\circ}C$에서 기판의 DC bias를 변화시키면서 박막을 증착시킬 때 나타나는 박막의 구조 변화를 raman spectrum의 To phonon peak의 위치와 반가폭의 변화로 나타낸 것이다. 비정질 실리콘 박막은 DC bias를 증가시킴에 따라 무질서도가 증가하다가 어떤 critical DC bias에서 최대치를 이룬후 다시 질서도가 증가한다. 이온의 충격력에 의해 박막내에 응력이 축적되면 박막의 에너지 상태가 높아지고 이 축적된 응력이 ordering에 대한 에너지 장벽을 넘을 수 있을 만큼 커지게 되면 응력이 풀리면서 ordering이 가능해지는 것으로 생각된다. 그림 2는 수소 결합 형태의 변화이다. 박막의 무질서도가 증가할 경우 알려진 바와 같이 2000cm-1근처의 peak은 감소하고 2100cm-1 부근이 peak이 증가하는 현상을 보였다. 본 논문에서는 여러 공정 변수, 특히 DC bias에 따르는 박막의 구조 변화와 다른 성장 조건(온도, 유량비)이 critical DC bias나 결정화, 결정성 등에 미치는 영향에 대한 분석결과를 보고하고자 한다.등을 이용하여 광학적 밴드갭, 광흡수 계수, Tauc Plot, 그리고 파장대별 빛의 투과도의 변화를 분석하였으며 각 변수가 변화함에 따라 광학적 밴드갭의 변화를 정량적으로 조사함으로써 분자결합상태와 밴드갭과 광 흡수 계수간의상관관계를 규명하였고, 각 변수에 따른 표면의 조도를 확인하였다. 비정질 Si1-xCx 박막을 증착하여 특성을 분석한 결과 성장된 박막의 성장률은 Carbonfid의 증가에 따라 다른 성장특성을 보였고, Silcne(SiH4) 가스량의 감소와 함께 박막의 성장률이 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 줄어들어 성장률이 Silane가스량에 의해 지배됨을 볼 수 있다. UV-VIS spectrophotometer에 의한 비정질 SiC 박막의 투과도와 파장과의 관계에 있어 유리를 기판으로 사용했으므로 유리의투과도를 감안했으며, 유리에 대한 상대적인 비율 관계로 투과도를 나타냈었다. 또한 비저질 SiC 박막의 흡수계수는 Ellipsometry에 의해 측정된 Δ과 Ψ값을 이용하여 시뮬레이션한 결과로 비정질 SiC 박막의 두께를 이용하여 구하였다. 또한 Tauc Plot을 통해 박막의 optical band gap을 2.6~3.7eV로 조절할 수 있었다. 20$0^{\circ}C$이상으로 증가시켜도 광투과율은 큰 변화를 나타내지 않았다.부터 전분-지질복합제의 형성 촉진이 시사되었다.이것으로 인하여 호화억제에 의한 노화 방지효과가 기대되었지만 실제로 빵의 노화는 현저히 진행되었다. 이것은 quinua 대체량 증가에 따른 반죽의 안정성이 저하되어 버린 것으로 생각되어진다. 더욱이 lipase를 첨가하면 반죽이 분화하는 경향이 보여졌지만 첨가량 75ppm에 있어서 상당히 비용적의 증대가 보였다. 이것은 lipase의 가수분해에 의해

  • PDF

Combination Effects of Large Dam and Weirs on Downstream Habitat Structure: Case Study in the Tamjin River Basin, Korea (대형 댐과 농업용 보가 하류 서식처 특성에 미치는 영향 연구: 탐진강 유역을 대상으로)

  • Ock, Giyoung;Kang, Ji-Hyun;Park, Hyung-Geun;Kang, Dong-Won
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.4
    • /
    • pp.638-646
    • /
    • 2018
  • The purpose of this study was to investigate the long-term habitat morphological alteration resulting from a large dam and weirs in the Tamjin River. To achieve this, we carried out a hydrograph analysis and a substrate size distribution analysis. We also estimated the channel width, bar area and vegetation encroachment using aerial photographs taken before and after the construction of the dam and weirs. The result of the hydrological analysis showed that flooding downstream was greatly reduced with small peaks occurrence after the dam construction. Interestingly, normal hydrographs in the main channel appeared just after tributary conjunction. There was a similar pattern in the substrate size analysis. Despite coarsened substrate just downstream of the dam site, more sand appeared again after introduction of the tributary. However, there was an increase in the bar area downstream of the dam's channels with most bars covered with vegetation. The channel width increased at the upper area of weirs through impoundment, but decreased downstream because of vegetation encroachment. This study indicate that unregulated tributary plays an important role in restoring hydro-physical habitat conditions in mainstream channels below a large dam. However, numerous weirs could be a causal factor to accelerate habitat deterioration in the dam downstream channels.