• Title/Summary/Keyword: 촬영 각도

Search Result 1,397, Processing Time 0.026 seconds

A Study on Double Angle of Optic Foramen in the Rhese Method (Rhese법 촬영에서 시신경구멍의 이중 각도에 대한 연구)

  • Park, Sang-Jo;Yoo, Ji-Na;Yoo, Myung-Seok;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.313-319
    • /
    • 2017
  • The purpose of this study is to confirm the double of optic foramen in Korean and apply it to the Rhese method. First, the angle between the right optic foramen and the MSP was measured on the axial image using MPR technique of the 3D CT. Second, we measured the angle between the right optic foramen and OML in sagittal of MPR images. As a result, the angle between the optic foramen and the MSP was $39.9{\pm}4.63^{\circ}$ on average, which was different from the $53^{\circ}$ presented by Rhese method(p<0.05). The angle between optic foramen and OML was $40.8{\pm}6.6^{\circ}$. In conclusion, this study confirms that the standard of the Rhese method proposed in current textbook is difficult to apply to Koreans. Therefore, it is necessary to study angle of Korean standard in various general x-ray technique.

A Study on the Optimal X-ray Angle to Observe Calcaneus (발꿈치뼈를 관찰하기 위한 최적의 X-ray 각도에 대한 고찰)

  • Sang-Min Shin;Bo-Moon Seo;Hae-In Jeon;Gyoung-Han Lee;Min-Cheol Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.2 no.1
    • /
    • pp.17-21
    • /
    • 2023
  • In this study, using an X-ray device (Drgem TS-CSP) and foot phantom (SFT-1556), the angle of the X-ray tube was changed to 30°, 35°, 40°, 45°, and 50°, and the image was evaluated by quantitative and qualitative evaluation. In the blind test, it was the highest at 4.34 points at 40°, and in the part calculation using the Image J program, the angle was the largest at 1750 at 50°. In addition, in the area evaluation excluding overlapping areas, the X-ray tube showed the largest value at 40° Therefore, it was found that the X-ray tube angle was suitable when the X-ray tube angle was 40° as a projection method for observing the calcaneus.

Optimal Location Allocation of CCTV Using 3D Simulation (3차원 시뮬레이션을 활용한 CCTV 최적입지선정)

  • PARK, Jeong-Woo;LEE, Seong-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.92-105
    • /
    • 2016
  • This study aims to establish a simulation method for CCTV (Closed Circuit Television) sight area. The simulation incorporates variables for computing CCTV sight area including CCTV specifications and installation. Currently CCTV is used for traffic, crime prevention and fire prevention by local governments. However, new locations are selected by administrator decision rather than analysis of the optimal location. In order to determine optimum location, a method to CCTV compute range is needed, which incorporates specifications according to CCTV purpose. For this purpose, limitations of previous research methods must be recognized and the simulation method must supplement these limitations. Here in this study, we derived CCTV sight area variables for realistic analysis to complement the limitations of previous studies. A total of eight elements were derived from image device sensors and installation: wide angle, height, angle, setting height, setting angle, and others. This research implemented a 3D simulation technique that can be applied to the derived factors and automate them using ArcObject and Visual C#. This simulation method can calculate sight range in accordance with CCTV specifications. Furthermore, when installing additional CCTVs, it can derive optimal allocation position. The results of this study will provide rational choices for specification selection and CCTV location by interagency collaborative projects.

The Validity of Head Posture Aligner in Posteroanterior Cephalometry (정모 두부 방사선 사진 촬영시 Head Posture Aligner의 유용성에 관한 연구)

  • Kim, Eun-Hee;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.543-552
    • /
    • 2000
  • The purposes of this study were to evaluate the reproducibility of posteroanterior(PA) cephalograms obtained by two methods, the Head Posture Aligner(HPA) method in natural head posture and the conventional method(operator-guided method), and to compare the vertical rotational differences of the head Posture between lateral and PA cephalograms according to the method. The sample was consisted of 30 adults. At first day, a PA cephalogram and a lateral cephalogram were obtained from each subject by two methods to investigate the difference of vertical rotational posture between lateral and PA cephalograms. Two weeks later, another PA cephalogram was obtained using each method to evaluate the reproducibility of head posture. Five height measurements and nine width measurements were used in the paired t-test to compare the reproducibility of the PA cephalometric measurements between two methods. The differences of vertical rotational posture between lateral and PA cephalograms were calculated from a computer program and compared according to the method used, and following results were obtained. 1. Height measurements obtained by operator-guided method showed significant differences according to the time interval and revealed low reproducibility. 2. Height measurements obtained by HPA method did not show significant differences according to the time interval and presented high reproducibility. 3. In the comparison of width measurement, two methods did not show distinct differences in reproducibility. 4. The difference of vertical rotational posture between lateral and PA cephalograms showed $0.8^{\circ}$ in the HPA method, more less than $2.5^{\circ}$ in the operator-guided method. The results of the present study suggest that the HPA may be helpful in the PA cephalometric radiography in terms of reproducibility.

  • PDF

A Comparison of Density and Patient Doses According to kVp and mAs Changes in General Radiography (일반촬영에서 kVp와 mAs의 변화에 따른 농도와 환자 선량 비교)

  • Kang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.987-994
    • /
    • 2019
  • Low energy x-rays that occur in the low tube voltage radiography of general radiography are absorbed strongly in the body and do not aid image quality enhancement. This study maintains titer in general radiography while using tube current that are proportional to density and the tube voltage 15% principle according to density to reduce patient exposure doses, and area doses and entrance surface doses were measured to compare patient exposure doses. In hand, knee, abdomen, and skull radiography, kVp was increased to 115% and mAs was decreased to 50% and kVp was decreased to 85% while mAs was increased to 200% and area doses and entrance surface doses were measured to compare relative doses. Also, 5 places in each image were set, density was measured, and Kruskal wallis H test was conducted to observe significance probabilities between groups. To fix density, kVp was increased to 115% and mAs was decreased to 50% and after measurements of mean area doses and entrance surface doses were made by each part, each decreased to 58.68% and 59.85% when standard doses were set to 100%, and each increased to 147.28% and 159.9% when kVp was decreased to 85% and mAs was increased to 200%. Comparisons of density changes showed that hand, knee, abdomen, and skull radiography all displayed significance probabilities>0.05, showing no changes in concentration. Radiography that increases kVp and lowers mAs through reasonable calculations within ranges that don't affect resolution and contrast seems to be a simple way to decrease patient exposure doses.

Standard of Creativity in the Copyrightable Photographic Works (사진저작물의 창작성 판단 기준)

  • Choi, Eun-Heui
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.93-105
    • /
    • 2015
  • Upon ruling that two photographs of "Solsum(located in Samchuk city)" are not substantially similar, issues on the level of protection for the copyrighted photographs expecially on landscape, which appearance could be similar whoever takes, were raised. Accordingly, this study summarizes and suggests the standards of expression differentiating from idea on photographic works. The results are as such. Elements of expression on photographs are positioning of subject, framing, selection of camera angle, control of light's direction and quantity, length of exposure, speed of shutter, timing or posing of the shutter. kinds of emulsion, methods of development, and any other methods of creative and characteristic photography. On the other hand, elements of ideas of photographic works are theme, concept, feeling, appearance of objects, time or season of taking a picture, vantage point, choice of horizontal or vertical angle, etc. As a result, this study reconfirms that copyright law entitles photographers to copyright as to their minimal degree of creativity, not as to their sweat of brows.

Analysys on Factors Affecting Velocity Errors On the Application of LSPIV (LSPIV를 적용시 오차발생 요인 분석)

  • Kim, Young-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1779-1783
    • /
    • 2008
  • 영상해석을 통한 흐름해석의 방법인 Large-Scale Particle Image Velocimetry (LSPIV)는 실험실내의 소규모 흐름해석에 이용하던 Particle Image Velocimetry (PIV)를 자연하천이나 실험실에서 넓은 영역($4m^2{\sim}45,000m^2$)에 적용할 수 있도록 확장시킨 것으로 지난 10여년전부터 세계적으로 널리 이에 대한 연구가 진행되고 있다. PIV는 seeding, illumination, recording 그리고 image processing으로 구성된다. LSPIV(Large Scale PIV)는 PIV의 기본원리를 근거로 하여 기존의 PIV에 비하여 실험실 내에서의 수리모형실험이나 일반 하천에서의 유속측정과 같은 큰 규모의 흐름해석을 할 수 있도록 seeding, illumination에 대한 조정이 필요 하고, 촬영된 image에 대한 왜곡을 없애는 작업이 필요하다. LSPIV는 PIV의 네 가지 단계를 포함하여 seeding, illumination, recording, image transformation, image processing 및 post-processing의 여섯 단계로 구성되어진다 (Li, 2002). LSPIV의 적용시 각 단계마다 유속계산시 오차를 발생시키는 27가지의 요인들이 존재하고 있는바 (Kim, 2006), 본 연구에서는 이들 중 실내의 실험실에서 파악이 가능한 인자들에 대해 그들 각각의 인자들이 유속 측정에 미치는 오차의 정도를 파악하고자 하였다. 본 연구에서는 LSPIV의 적용시 이용되는 이미지의 개수와 이미지 촬영시 적용된 이미지의 해상도에 따른 오차의 발생 정도를 조사하였다. 이미지 촬영에 있어서 비디오카메라를 이용할 경우 촬영시간에 따라 많은 수의 이미지를 취득할 수 있은바 이미지의 수에 따른 유속계산오차를 파악하고자 하였다. 또한 디지털 카메라를 이용할 경우 여러 가지 이미지 해상도를 이용할 수 있으므로 적용한 이미지 해상도에 따른 유속계산에 미치는 오차의 크기를 파악하고자 하였다. 이미지의 갯수가 유속계산시 미치는 오차의 영향의 정도를 조사하기 위해서 초당 30 frame을 촬영할 수 있는 비디오카메라를 이용하여 91초 동안 촬영된 이미지로부터 매 5번째의 이미지를 추출하여 455개의 이미지를 준비하였고 이로부터 이미지수를 10, 50, 100, 200, 300, 400의 순서로 증가시키면서 이미지 개수로부터 나타나는 유속계산 오차를 조사한 결과 이미지의 개수가 50매 이상인 경우는 이로 인한 오차가 1% 이하로 감소함을 파악하였다. 촬영된 이미지의 해상도가 유속계산시 미치는 영향을 조사하기 위해 디지털카메라를 적용하여 세가지 이미지 해상도(640*480, 1280*960, 2048*1536 pixel)로 변화시키면서 유속측정 오차를 분석한 결과 저해상도의 이미지를 이용한 경우 고해상도 이미지를 이용한 경우와 비교하여 3% 가량의 차이를 나타내었다.

  • PDF