• Title/Summary/Keyword: 촬영각도

Search Result 312, Processing Time 0.026 seconds

A Study on Projection Angles for an Optimal Image of PNS Water's View on Children (유.소아 부비강 Water's 영상의 이상적 구현을 위한 촬영기준각도 변화에 관한 연구)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Sung-Kyu;Hong, Sang-Woo;Kim, Je-Bong
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patients's skull. And then, we calculated the incidence angles(Angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general(random) patients's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patients' ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle(Angle B) between OML and IP(Image Plate). The angle between OML and IP is about $43^{\circ} in 4-years-old children, which is higher than $37^{\circ}, as age increases the angle decreases, it goes to $37^{\circ} around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage.

  • PDF

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat (전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성)

  • Seo, Sun-Youl;Cho, Jeong-Hee;Han, Man-Seok;Kim, Tae-Hyung;Yoo, Se-Jong;Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2760-2766
    • /
    • 2013
  • Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.

Effects of vertical head rotation on the posteroanterior cephalometric measurements (정모두부방사선사진 촬영시 두부의 수직회전에 따른 투사오차)

  • Koh, Eun-Hee;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.73-84
    • /
    • 2003
  • This study was performed to find out how much projection errors in the cephalometric measurements were made by vertical head rotation in taking posteroanterior cephalograms. 25 adults without any apparent facial asymmetry or severe sagittal skeletal discrepancy were selected and the posteroanterior cephalograms were taken with the head rotated $5^{\circ},\;10^{\circ}$ superior and inferior each to the reference $position(0^{\circ})$. The 7 height, 5 width and 6 angular measurements were taken at each 5 positions. Through the statistical analysis of all measurements taken at each rotated position, folowing results were obtained.1. The projection errors of height measurements were remarkably target than those of width or angular measure nents. f. Among the height measurements, the farther to the rotation axis the measurements were, the larger the projection errors were. 3. Among the width measurements, mandibular width and mandibular width of mandibular first molars showed significant differences between the values taken at each rotated position, while nasal width, maxillary width and intermolar width of maxillary first molars did not. 4. Among the angular measurements, the angle between horizontal reference line and the line that is connected to crista galli and antegonion or maxillare showed significant differences between the values taken at each rotated Position. The above results suggest that it is needed to the effort to keep constant head position for taking the useful posteroanterior cephalogra, because projection errors are caused by vertical head rotation.

The Diagnosis of Rheumatologic and Degenerative Arthritis by X-ray Sacroiliac Joint Projection (X-ray 엉치엉덩관절 촬영법을 통한 류마티스 및 퇴행성관절염 진단)

  • Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.397-402
    • /
    • 2018
  • The study best image for diagnosis of fracture, dislocation and unilateral degenerative arthritis of the Sacroiliac joint, this study was performed to obtain the best image of the joint space of the hip joint by giving angle change to the pelvis phantom and the x-ray tube. I received evaluation. The results of the Receiver Operating Characteristic that in the case of simple photographs for the detection of joint arthritis and degenerative arthritis in the prone position, the photograph taken in the prone position raises the buttocks of the opposite side of the test by $25^{\circ}{\sim}30^{\circ}$ and the x-ray tube is perpendicular to the sagittal plane passing 2.5 cm inward from the thorny vertebra In the lying position, lift the Sacroiliac joint of the test side by $25^{\circ}{\sim}30^{\circ}$, and take a $5^{\circ}$ angle of the x-ray tube angle toward the foot toward the center of the upper bruch spine from it will be helpful to diagnose arthritis. the center of the upper bruch spine to the side of the ankle joints in the transverse direction And posterior direction, it will be helpful to diagnose arthritis.

Determination of Appropriate Exposure Angles for the Reverse Water's View using a Head Phantom (두부 팬텀을 이용한 Reverse Water's View에 관한 적절한 촬영 각도 분석)

  • Lee, Min-Su;Lee, Keun-Ohk;Choi, Jae-Ho;Jung, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.187-195
    • /
    • 2017
  • Early diagnosis for upper facial trauma is difficult by using the standard Water's view (S-Water's) in general radiograph due to overlapping of anatomical structures, the uncertainty of patient positioning, and specific patients with obese, pediatric, old, or high-risk. The purpose of this study was to analyze appropriate exposure angles through a comparison of two different protocols (S-Water's vs. reverse Water's view (R-Water's)) by using a head phantom. A head phantom and general radiograph with 75 kVp, 400 mA, 45 ms 18 mAs, and SID 100 cm. Images of R-Water's were obtained by different angles in the range of $0^{\circ}$ to $50^{\circ}$, which adjusted an angle at 1 degree interval in supine position. Survey elements were developed and three observers were evaluated with four elements including the maxillary sinus, zygomatic arch, petrous ridge, and image distortion. Statistical significant analysis were used the Krippendorff's alpha and Fleiss' kappa. The intra-class correlation (ICC) coefficient for three observers were high with maxillary, 0.957 (0.903, 0.995); zygomatic arch, 0.939 (0.866, 0.987); petrous ridge, 0.972 (0.897, 1.000); and image distortion, 0.949 (0.830, 1.000). The high-quality image (HI) and perfect agreement (PA) for acquired exposure angles were high in range of the maxillary sinus ($36^{\circ}-44^{\circ}C$), zygomatic arch ($33^{\circ}-40^{\circ}$), petrous ridge ($32^{\circ}-50^{\circ}$), and image distortion ($44^{\circ}-50^{\circ}$). Consequently, an appropriate exposure angles for the R-Water's view in the supine position for patients with facial trauma are in the from $36^{\circ}$ to $40^{\circ}$ in this phantom study. The results of this study will be helpful for the rapid diagnosis of facial fractures by simple radiography.

Analysis of influence of twisting angle between contacts on arc behavior in spiral type VI by analysing arc photographs and arc voltage (나선형 VI전극 내부에서 아크촬영사진과 아크전압분석을 통한 전극간 비틀림 각도가 아크거동에 미치는 영향 분석)

  • Kim, Byoung-Chul;Park, Jong-Bae;Park, Hongl-Tae;Kang, Seong-Wha;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.151-152
    • /
    • 2008
  • 본 논문에서는 전극간의 비틀림 각도가 아크거동에 미치는 영향을 알아보기 위해 고속카메라를 이용한 아크촬영과 아크전압측정을 동반한 전류차단시험을 실시하였다. 측정결과를 이용한 아크거동 분석결과를 각 모델에 대한 유한요소해석을 통한 로렌츠 힘 계산결과와 결부시켜 비틀림 각도가 아크거동에 미치는 영향을 분석하였다.

  • PDF

Distortion Corrected Black and White Document Image Generation Based on Camera (카메라기반의 왜곡이 보정된 흑백 문서 영상 생성)

  • Kim, Jin-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.18-26
    • /
    • 2015
  • Geometric distortion and shadow effect due to capturing angle could be included in document copy images that are captured by a camera in stead of a scanner. In this paper, a clean black and white document image generation algorithm by distortion correction and shadow elimination based on a camera, is proposed. In order to correct geometric distortion such as straightening un-straight boundary lines occurred by camera lens radial distortion and eliminating outlying area included by camera direction, second derivative filter based document boundary detection method is developed. Black and white images have been generated by adaptive binarization method by eliminating shadow effect. Experimental results of the black and white document image generation algorithm by recovering geometrical distortion and eliminating shadow effect for the document images captured by smart phone camera, shows very good processing results.

A Fuzzy-based License Plate Extraction Method under Real Conditions (퍼지원리에 기반한 차량 번호판 추출 방법)

  • Kwon, Sung-Jin;Kim, Gyeong-Hwan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.850-852
    • /
    • 2005
  • 차량을 포함하는 임의의 영상에서 번호판 추출은 다양한 조명조건 및 배경, 촬영 각도, 번호판 종류 등의 요인으로 인해 고도의 영상처리 과정을 필요로 한다. 본 논문에서는 실제 환경에서 발생할 수 있는 이러한 요인들에 대해 강건한 번호판 추출 방법을 제안한다. 제안하는 방법은 입력영상의 RGB 성분들을 색상성분과 영암성분으로 분리할 수 있는 칼라모델 HSI로 변환하고 H(hue)와 S(saturation)성분을 이용하여 번호판의 배경색상을 고려한 칼라 퍼지지도를 구성한다. 또한, I(intensity)성분을 이용하여 에지밀도를 추출하고 에지밀도 지도에 기반한 영역분리 퍼지지도를 생성한다. 마지막으로, 후보영역 탐색을 위해 칼라 퍼지지도와 영역분리 퍼지지도를 결합하고, 연결성분 해석(Connected Component Analysis)을 통해 ROI(Region Of Interest)를 추출한다. 제안하는 방법의 유효성 검증을 위해 조명 및 촬영 각도에 제한을 거의 두지 않고 촬영된 차량 영상 410장을 실험 영상으로 사용하였다. 실험 결과에서는 $97.1\%$의 효과적인 추출 성공률을 볼 수 있었다.

  • PDF

A Study on Double Angle of Optic Foramen in the Rhese Method (Rhese법 촬영에서 시신경구멍의 이중 각도에 대한 연구)

  • Park, Sang-Jo;Yoo, Ji-Na;Yoo, Myung-Seok;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.313-319
    • /
    • 2017
  • The purpose of this study is to confirm the double of optic foramen in Korean and apply it to the Rhese method. First, the angle between the right optic foramen and the MSP was measured on the axial image using MPR technique of the 3D CT. Second, we measured the angle between the right optic foramen and OML in sagittal of MPR images. As a result, the angle between the optic foramen and the MSP was $39.9{\pm}4.63^{\circ}$ on average, which was different from the $53^{\circ}$ presented by Rhese method(p<0.05). The angle between optic foramen and OML was $40.8{\pm}6.6^{\circ}$. In conclusion, this study confirms that the standard of the Rhese method proposed in current textbook is difficult to apply to Koreans. Therefore, it is necessary to study angle of Korean standard in various general x-ray technique.

The Tangential Projection Method for Checking Existence and Nonexistence of Radius Groove Penetration of Screw after Distal Radius Fracture Operation Used the T-type Plate (T형 금속판을 이용한 요골 원위부 골절 수술 후 나사못의 요골구 관통 유무를 확인하기 위한 접선방향 촬영법)

  • Seo, Sun-Youl;Hong, Ki-Jang;Han, Man-Seok;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.335-340
    • /
    • 2010
  • This paper is about a projection method to check existence of radius groove penetration of screw after distal radius fracture operation using the T-type plate. Angle of Radius groove was analyzed by fifty one CT images that contains patients' wrist and twenty cases of radius specimens. After making radius phantom by plaster, we set the screw so that it penetrated 2.4 mm depth of radius groove. Then, we projected the phantom by X-ray in change of the elevation and supination angle of distal radius by 5 degree interval on 0~30 degree. The average value of groove angle in the wrist CT images was 14.4 degree and the radius specimens was 16.3 degree. Screws penetrating radius groove of the phantom have different lengths according to elevation angle and supination angle. Consequently, in order to confirm existence and nonexistence of radius groove penetration of the screw in tangential projection after distal radius fracture operation using the T-type plate, we recommend 5 degree of elevation angle and 20 degree of supination angle.