• Title/Summary/Keyword: 총유기물질

Search Result 33, Processing Time 0.021 seconds

The Removal Characteristics of Organic Matter in Drinking Water Source by Coagulation and Ultrafiltration Process (응집 및 한외여과 공정에 의한 상수원수의 유기물질 제거 특성)

  • Kim, Hyun-Sik;Lim, Ji-Young;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.5-10
    • /
    • 2018
  • This study was evaluated the characteristics of organic materials in the water source and the removal characteristics of organic materials by ultrafiltration including mixing and coagulation process. As a results of the study, it was found that the total organic carbon in the water source was mostly caused by the dissolved organic materials. As the specific ultraviolet absorbance value of the raw water was low, we found the soluble organic material has a high hydrophilic and low molecular material composition ratio. As a result of ultrafiltration experiment including mixing and coagulation process, the average removal rate of total organic carbon, dissolved organic carbon and ultraviolet absorbance at 254 were 37.9%, 30.3%, and 28.2%, respectively.

Spatial-Temporal Characteristics for Non-degradable materials in Dongjin Watershed (동진강수계 난분해성 물질의 시공간적 거통 특성 분석 연구)

  • Kim, Se Min;Kim, kyung Oh;Park, Young Ki
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.424-424
    • /
    • 2019
  • 수질오염 저감을 위한 유기물질의 처리를 위해 생물학적 처리에 중점을 둔 하 폐수 처리시설의 증가에 따라 BOD로 대표되는 생분해성 유기물질은 꾸준히 감소하였으나, COD농도의 경우 뚜렷한 감소를 보이지 않고 있다. 유기물질 중 특히 난분해성 물질의 증가는 상수원으로 사용되는 하천의 경우 조류 증식 등을 유발하고 여과공정에 영향을 미쳐 상수처리의 효율을 떨어뜨리는 등의 환경적인 문제를 야기할 수 있다. 기존 BOD, COD로 대표되는 유기물질의 경우 각 유기물질별 상관관계 및 유출특성 등에 대한 연구는 많이 이루어졌으나, 난분해성 물질에 대한 조사는 상대적으로 미진한 실정이다. 특히 동진강수계는 '새만금 제2단계 수질개선종합대책' 등 장기적인 수질개선 대책들이 추진되면서 하천의 BOD5 및 TP는 감소추세를 보이고 있으나, COD는 개선되지 않고 증가하는 추세를 보이고 있다. 동진강의 말단부의 경우 COD/BOD5의 비율이 지속적으로 증가하는 추세를 보이고 있어 상대적으로 난분해성 유기물질에 대한 관리의 중요성이 대두되고 있다. 이러한 COD 및 COD/BOD5의 증가 추세는 국내 4대강에서 전반적으로 나타나고 있는 추세로서, 정부는 2013년부터 하천 및 호소의 생활환경기준에 TOC 항목을 도입하여 2016년부터 호소환경기준의 대표항목을 COD에서 TOC로 대체하였으며, 폐수배출시설에 대해서도 점차적으로 확대 적용할 계획으로, 난분해성물질을 포함하는 총유기물질 관리를 위해서 수질 및 수생태계 환경기준에서 유기물질에 대한 환경기준을 BOD5와 COD에서 TOC로 변경하는 정책을 추진 중에 있다. 본 연구에서는 동진강 유역의 본류 및 지류에서 TOC등 유기물질의 시공간적인 분포와 오염원별 배출특성을 현장조사를 통해 조사 분석하였다. 조사 시기는 건기시, 강우시로 구분하여 수행하였으며 조사항목은 일반수질항목, 유기물질 항목, 유기물질 성상 분석 등에 대하여 수행하였다. 난분해성물질 관리를 위한 기초자료확보를 통하여 새만금호의 수질개선 및 목표수질 달성에 기여 할 것으로 판단된다.

  • PDF

Correlation analysis between TOC and organic matter indices in influent and effluent of public sewage treatment facilities (공공하수처리시설 유입수 및 방류수에서 TOC와 유기물질 관리지표간의 상관성 분석)

  • Son, Dong-Jin;Jeong, Dong-Hwan;Park, Kyoo-Hong
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.4
    • /
    • pp.122-129
    • /
    • 2021
  • As the total organic carbon (TOC) becomes a new water quality standard as an organic matter (OM) index for public sewage treatment facilities (PSTFs) in Korea from 2021, a comparison study needs to be conducted by examining the correlation between TOC and the existing OM indices (DOC, BOD5, CODMn, CODCr). 500 PSTFs were categorized by process configuration and capacity, and correlation between OM indices in influent and effluent was analyzed. The CODMn/TOC showed higher correlation than other OM indices. This results can be used to basic data for various research associated with TOC.

Comparison of Instrument Characteristics on the Total Organic Carbon Analysis Method in Water Samples (수질분야 총유기탄소 분석방법에 따른 장비별 특성 비교)

  • Hye-Sung Kim;Eun-Tae Hwang;Chan-Geun Lee;Young-Cheol Cho
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.353-362
    • /
    • 2023
  • TOC, which can measure more than 90% of organic substances, can be measured quickly and easily,replacing BOD and COD, which were indicators of organic pollutants. According to water quality pollution control standards, when measuring TOC, if the inorganic carbon ratio in the sample is over 50%, the NPOC (Non-Purgeable Organic Carbon) method should be used. If volatile organic compounds (VOCs) are present at a certain concentration, the TC-IC (subtracting inorganic carbon from total carbon) method should be used. To validate the limitations of these analytical conditions, experiments were conducted by varying the ratio of TOC to IC in purified water and measuring the concentration of TOC in test solutions. The results showed no significant difference between the TC-IC method and the NPOC method. When measuring samples with added VOC standard solutions, it was observed that the carbon loss due to purging was not significant when using the NPOC method. Therefore, it is concluded that the choice of analytical method does not lead to significant differences when VOCs are present in the sample. To account for potential variations in results based on water quality pollution control standards and regulations regarding the approval and testing of environmental measurement devices, a comparison of field sample concentration values was made using two widely used types of TOC analyzers in Korea. The results showed variations of 0.02 to 0.83 mg/L between methods depending on the manufacturer, highlighting the need for caution when selecting an instrument.

Characteristics and Effective Usage of Organic Indexes in Water Environments -Lakes in Nakdong River Basin- (물환경에서의 유기물질 지표 특성 및 효율적 이용방안 -낙동강수계 호소수를 대상으로-)

  • Kang, Meea
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.153-160
    • /
    • 2014
  • TOC environmental standard was established to understand the pollution level accurately and to improve the water quality. It was found that the relationship between COD and TOC showed a significant coefficient($R^2$=0.639) in four lakes for drinking water located in Nakdong River basin. The relationship between COD and TOC($R^2$=0.774) was higher with respect to the elevated concentration level when the data was added. Resulting in the oxidation(C) was $62{\pm}8%$ regardless of COD concentrations. It was difficult to find a significant difference by lakes. The result showed the similar organic property in study lakes. It was necessary to evaluate the level of organic matters in consideration of characteristics and utilization of lakes to use COD data wisely until TOC data be accumulated sufficiently.

Retention properties of organic matters and nutrients in wetland soils and coastal sediments (습지토양 및 연안퇴적물의 유기물질 및 영양물질 보유 특성)

  • Park, Soyoung;Yi, Yong Min;Yoon, Han-Sam;Sung, Kijune
    • Journal of Wetlands Research
    • /
    • v.14 no.2
    • /
    • pp.265-275
    • /
    • 2012
  • As climate change is becoming a growing concern and the importance of water management is increasing, the retention of carbon and nutrients in wetland soils including inland and coastal area has become important. In this study, retention characteristics of organic matter and nutrients of coastal sediment and soils in different types of wetlands such as constructed wetland, natural (inland marsh, estuary, tidal flat) wetlands were investigated. A correlation analysis was also performed to understand the relationship among organic matter properties, nutrient concentrations and soil texture of wetland soils. The degree of retention of organic matter and nitrogen in wetland soils varied with the wetland type. Inland wetlands retain more nitrogen than estuary or coastal wetlands, and natural wetlands retain more organic matter and nitrogen than constructed ones. Coastal sediments in a bay area where seawater circulation is restricted have more nutrients than those in estuary or tidal flats where seawater circulates well. The results showed that the sediment chemical oxygen demand has a high correlation with the total organic carbon and the total nitrogen in the studied area.

Water Management Plan for the Nakdong River Using TOC and COD (총유기탄소와 화학적산소요구량을 이용한 낙동강 물관리 방안)

  • Bo Eun Kim;Meea Kang;Gyo-Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2023
  • The Nakdong river is both a natural resource crucial to underwater ecosystems and a water source for its basin's residents. Industrial wastewater and domestic sewage must meet the relevant standards for discharged water before they can flow into the river. The correlation between old and new measures of organic matter was examined using water quality data from 50 monitoring locations in the main stream of the Nakdong river. The coefficient of determination (R2) for total organic carbon (TOC), the new measure of organic matter, and chemical oxygen demand (COD), the old measure of organic matter, in the main stream of the Nakdong river was 0.6134, indicating high correlation. Water quality at each location assessed using TOC and COD showed disparities that cannot be ignored: quality appeared higher when evaluating the main stream of the Nakdong river using TOC instead of COD. Therefore, there remains a need to review water quality ratings based on TOC; continuous monitoring of COD is also required. In addition, the cause of the difference should be clearly identified to help assess artificial sources of pollution and natural factors affecting organic matter. Water management of the Nakdong river will then be possible using the water quality rating.

Bacterial attachment on granular activated carbon and effect of chlorine disinfection (입상활성탄 부착세균과 염소소독 연구)

  • Baek, Youngae;Joe, Woohyun;Hong, Byungeui;Choi, Youngjune;Ahn, Seoungkoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.339-344
    • /
    • 2009
  • The authors investigated the bacterial community attached to granular activated carbon(GAC) particles and the susceptibility of the community to chlorine disinfection. The study was carried out at the G Water Treatment Plant in Seoul, which was in full-scale operation. Bacteria attached to the surface of GAC increased gradually with treatment from $0.4{\times}106{\sim}8.5{\times}106 CFU/g$. TOC removal was under 1.0 mg/L due to increased bacterial community on the surface of GAC. It was found that TOC removal was closely related with physical and biological parameters such as pore volume and the number of attached bacteria. When the washed and the attached cells were disinfected with 1.0mg/L of chlorine for 1 hour, the washed cells with chlorination could be controlled, but the number of the attached cells increased gradually. The results suggest a possibility that the treatment and disinfection barriers can be penetrated and pathogenic bacteria may break into the drinking water supplying system.

Full-scale Case Study on the Relationship between Surface Characteristics of GAC and TOC Removal (입상활성탄의 표면특성과 TOC제거와의 상관성 연구)

  • Baek, Youngae;Joe, Woohyun;Hong, Byungeui;Kim, Kwangho;Choi, Young-june
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.323-328
    • /
    • 2008
  • During the full-scale water treatment operation at "G" Water Treatment Plant in Seoul, we investigated changes in pore volume distribution and specific surface area of GAC with time. The pore volume of the used GAC decreased to the level below 0.6 cc/g while that of the brand new GAC was ranged 0.7~0.9 cc/g. The specific surface area of GAC pores changed within the range between $1100{\sim}1200m^2/g$ and $700{\sim}800m^2/g$. Bacteria attached to the surface of GAC shows a gradual increase ($0.4{\time}10^6{\sim}8.5{\time}10^6CFU/g$) under scanninig electron microscope (SEM). TOC removal was enhanced due to growth of the attached bacteria on GAC. It was found that TOC removal was closely related with physical parameters (pore volume, specific surface area) linearly under the investigated conditions. The used GAC need to be exchanged into new one or re-generated to remove organic matters (TOC) effectively from the finished drinking water.

Selection of the Optimum Organic Matter Index for Surface Water Quality Management (지표수 수질관리를 위한 적정 유기물질지표 선정)

  • Han, Dae Ho;Choi, Ji-Yong
    • Journal of Environmental Policy
    • /
    • v.10 no.4
    • /
    • pp.61-80
    • /
    • 2011
  • Through concentrated investments in environmental regulations centered around BOD, which is a biodegradable matter index, and basic environmental infrastructures, national BOD pollution level has continuously improved. Nonetheless, limitations of BOD management system has become evident through nation-wide stagnation and/or increases of refractory organic matters, such as COD, at main drinking water sources, and the need for a new index, which can easily indicate different environmental conditions, has increased. Therefore, this study suggests a new organic management index for a proper management of surface water. $COD_{Cr}$ and TOC were examined as candidates for surface water quality management index, and it was found that TOC was more appropriate than $COD_{Cr}$ as an organic matter management index. Through this study, it was found that TOC possesses following qualities: a more representative index; international acceptability; monitoring program is easier; better availability of analysis techniques; better accuracy and precision of analysis; less time required for analysis; ease of operation; management of disinfection byproducts; connection with present policies; existence of foreign and domestic application case studies; and correlation with water ecosystem.

  • PDF