• Title/Summary/Keyword: 총오류의 최소화

Search Result 26, Processing Time 0.024 seconds

Regional Disparity of Ambulatory Health Care Utilization (시공간 분석을 이용한 외래 의료이용의 지역적 차이 분석)

  • Shin, Ho-Sung;Lee, Sue-Hyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.4
    • /
    • pp.138-150
    • /
    • 2012
  • The purpose of this study was to examine the regional disparity of ambulatory health care utilization considering spatio-temporal variation in South Korea during 1996-2008(precisely, in 1996, 1999, 2002, 2005, and 2008) using bayesian hierarchial spatio-temporal model. The spatial pattern uses an intrinsic gaussian conditional autoregressive (CAR) error component. Ornstein-Uhlenbeck method was applied to detect the temporal patterns. The results showed that substantial temporal-geographical variation depending on diseases exists in Korea. On the Contrary to the pattern of total outpatient utilizations, for example, the areas that chronic diseases distributed relatively high were most in rural where the proportion of elderly population was higher than in the urban. Chungcheongnam-do, Junlabuk-do, and Kyeongsangbuk-do had higher risks in hypertension, whereas arthritis was higher risk in the Kyeonggi-do, Chungcheongbuk-do, Junlanam-do, and Junlabuk-do. The results of this study suggested that the effective health intervention programmes needed to alleviate the regional variation of health care utilization. These outcomes also provided the foundation for further investigation of risk factors and interventions in these high-risk areas.

A Study on Degradation Phenomenon Based on Test Device for Aging Diagnosis in PV Modules (태양광모듈의 열화진단 시험장치 구현 및 열화특성에 관한 연구)

  • Shen, Jian;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.27-35
    • /
    • 2021
  • Generally, a proper evaluation method of the aging phenomenon of PV modules is required as the electrical performance and lifespan of PV modules can degrade significantly due to several environmental factors, while they are generally known as devices that are used semi-permanently for more than 20 years. On the other hand, there is a lack of objectivity in the existing evaluation method of the aging phenomenon, which compares the adjusted PV output based on STC with the initial PV module specifications due to the data distortion while adjusting the measured data. Therefore, this study implemented a test device for an aging diagnosis to measure and collect actual data from a PV module section and modeled the data for aging using MATLAB S/W to minimize the variability of the PV output, communication error, and delay. Furthermore, this study confirmed the usefulness of the presented test device for aging diagnosis of the PV modules by diagnosing the total period and yearly-basis degradation rate of aging PV modules as 25.73% and 1.55%, respectively, according to the on-site output characteristics of the PV modules by season.

A Case Study on the Risk Analysis for the Installation of Measurement Error Verification Facility in Hydrogen Refueling Station (수소 충전소 계량오차 검증 설비 설치를 위한 위험성 분석 사례 연구)

  • Hwayoung, Lee;Hyeonwoo, Jang;Minkyung, Lee;Jeonghwan, Kim;Jaehun, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.30-36
    • /
    • 2022
  • In commercial transactions of energy sources using hydrogen charging stations, high-accuracy flow meters are needed to prevent accidents such as overcharging due to inaccurate measurements and to ensure transparency in hydrogen commercial transactions through accurate measurements. This research developed a Corioli-type flowmeter prototype and conducted a risk assessment to prevent accidents during a process change comparison experiment for existing charging stations to verify the measurement performance. A process change section was defined for the installation of measurement facilities for empirical experiments and HAZOP was conducted. In addition, JSA was also conducted to secure the safety of experimenters, such as preventing valve mis-opening during empirical experiments. Measures were established to improve the risk factors derived through HAZOP, and work procedures were established to minimize human errors and ensure the safety of workers through JSA. The design change and system manufacturing for the installation of the metering system were completed by reflecting the risk assessment results, and safety could be confirmed through the performance comparison test of the developed meter prototype. The developed prototype flow meter showed a total of 30 flow measurements under the operating conditions of 70 MPa, and the average error was -1.58% to 3.96%. Such a metering error was analyzed to have the same performance as a flow meter installed and operated for commercial use.

Optimization of Approximate Modular Multiplier for R-LWE Cryptosystem (R-LWE 암호화를 위한 근사 모듈식 다항식 곱셈기 최적화)

  • Jae-Woo, Lee;Youngmin, Kim
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.736-741
    • /
    • 2022
  • Lattice-based cryptography is the most practical post-quantum cryptography because it enjoys strong worst-case security, relatively efficient implementation, and simplicity. Ring learning with errors (R-LWE) is a public key encryption (PKE) method of lattice-based encryption (LBC), and the most important operation of R-LWE is the modular polynomial multiplication of rings. This paper proposes a method for optimizing modular multipliers based on approximate computing (AC) technology, targeting the medium-security parameter set of the R-LWE cryptosystem. First, as a simple way to implement complex logic, LUT is used to omit some of the approximate multiplication operations, and the 2's complement method is used to calculate the number of bits whose value is 1 when converting the value of the input data to binary. We propose a total of two methods to reduce the number of required adders by minimizing them. The proposed LUT-based modular multiplier reduced both speed and area by 9% compared to the existing R-LWE modular multiplier, and the modular multiplier using the 2's complement method reduced the area by 40% and improved the speed by 2%. appear. Finally, the area of the optimized modular multiplier with both of these methods applied was reduced by up to 43% compared to the previous one, and the speed was reduced by up to 10%.

Standardization of Identification-number for Processed Food in Food-traceability-system (가공식품에 대한 이력추적관리번호 부여체계의 표준화 방안)

  • Choi, Joon-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.2
    • /
    • pp.194-201
    • /
    • 2012
  • Facing a number of global food-related accidents, the concept and system for food traceability have been designed and introduced in many countries to manage the food-safety risks. To connect and harmonize the various food traceability-information in food traceability system according to the food supply chain, the coding system of identification-number for food-traceability has to be standardized. The GTIN (Global Trade Item Number) barcode system which has been globally standardized and implemented, is reviewed with the mandatory food-labeling regulation in expiration date of processed foods. The integration of GTIN-13 bar-code system for food-traceability is a crucial factor to expand its function in the food-related industrial areas. In this literature, the standard coding system of identification-number for food-traceability is proposed with 20 digit coding number which is combined with GTIN-13 bar-code (13 digit), expiration date (6 digit), and additional classification code (1 digit). This proposed standard coding system for identification-number has a several advantages in application for prohibiting the sale of hazard goods, food-recall, and inquiring food traceability-information. And also, this proposed coding system could enhance the food traceability system by communicating and harmonizing the information with the national network such as UNI-PASS and electronic Tax-invoice system. For the global application, the identification-number for food-traceability needs to be cooperated with the upcoming global standards such as GTIN-128 bar-code and GS1 DataBar.

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF