• Title/Summary/Keyword: 초효율성 분석

Search Result 200, Processing Time 0.031 seconds

A Study on Proficiency Comparison Testing Between Testers Using ISO/IEC 25023 Software Quality Characteristics Evaluation (ISO/IEC 25023 소프트웨어 품질 특성 평가를 이용한 시험자간 비교시험에 관한 연구)

  • Lee, Chang-Hee;Kim, Myung-Sup;Kim, Yoon-Sook;Noh, A-Reum;Yang, Jung-Sim;Song, Sung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.18-27
    • /
    • 2020
  • This study compared and analyzed the results of proficiency testing between testers based on the international standard ISO/IEC 17043 proficiency testing requirements using ISO/IEC 25023 software quality characteristics evaluation. Application of the test was submitted to the KASTO as a software test in the electric test field defined by KOLAS. Among ISO/IEC 25023, the evaluation items for proficiency testing between testers were selected as functional completeness and time behavior. The comparison test between testers was carried out on May 28, 2019 at the accredited LG Electronics SW Laboratory in Seoul and attended by KOLAS assessors. The test evaluation method was measured once per tester with functional completeness, and measurement was repeated 10 times per tester according to time behavior. As a result, in the case of functional completeness, all 12 test steps were passed, and the satisfaction was evaluated. Time behavior was repeated 10 times, and the mean was 9.45 ± 0.01 seconds for testers 1 and 3 and 9.52 ± 0.0 seconds for tester 2, but there was no statistically significant difference. In conclusion, the proficiency of the testers was equal, and the reliability of the test results of the test institute was confirmed.

Additional CSP calculation method considering Human Error (휴먼에러를 고려한 추가 CSP 산정 방안)

  • Baek, Sung-Il;Ha, Yun-chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.759-767
    • /
    • 2021
  • Most weapons systems that are Force Integration are expensive equipment that reflects the latest technology, and the operation and maintenance cost is increasing continuously. Factors that efficiently operate and maintain these weapon systems include maintenance plans, economic costs, and repair part requirements. Among them, predicting the repair parts requirements during the life cycle in advance is an important way to increase operation and maintenance cost efficiency and operating availability. The start of requirement analysis for repair parts is a calculation of the CSP (CSP: Concurrent Spare parts, CSP hereafter) that is distributed when the weapon system is deployed. The CSP is an essential component of achieving the operating availability during this period because the weapon system aims to successfully perform a given operation mission without resupply for an initial set period. In the present study, the CSP calculation method was analyzed, reflecting the failure rate and operating time of items, but the analyzed CSP was aimed at preparing for technical failure, but in the initial operating environment, it is limited in coping with unexpected failures caused by human error. The failure is not included in the scope of free maintenance and is a serious factor in making the weapon system inoperable during the initial operation period. To prevent the inoperable status of a weapon system, CSP that considers human error is required in the initial operating environment, and the calculation criteria and measures are proposed.

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.

3D Modelling Shape Embodiment and Efficiency Analysis of Reservoir that using RTK-GPS and E/S (RTK-GPS와 E/S를 이용한 저수지의 3D 모델링 형상 구현과 효율성 분석)

  • Lee, Jae-One;Park, Un-Yong;Yang, Young-Bo;Kim, Yong-Suk
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.13 no.1 s.31
    • /
    • pp.11-17
    • /
    • 2005
  • A lot of small-scale reservoirs that is extravagant in whole country are controlled state or real condition that correct data about the practice contents is not equipped all up to now. In this study, YungNam districts that region Gyeong-Ju city reservoir is distributed much of when flow speedily choose 23 peace among 73 small scale reservoir and experimented. Acquired data every 5 seconds, and user E/S and user value TS for orthocenter to 1 second interval and executes present condition measurement using RTK-GPS. Could was wave and state that reservoir of 15 places (about 65%) gives protective care that do 3D modelling with acquired data, and now correct contents about reservoir state past through comparative analysis with data. Also, area of full water and wave that analyze effective storage and area of full water of 23 places reservoir could know that 20.63%, effective storage decreased as 3.34%. I wish to contribute about analysis about present reservoir state through this and method the adminstration direction.

  • PDF

3D Modelling Shape Embodiment and Efficiency Analysis of Reservoir (저수지의 3D 모델링 형상 구현과 효율성 분석)

  • Song, Youn-Kyung;Hong, Soon-Hyun;Hong, Jung-Soo
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.2
    • /
    • pp.113-120
    • /
    • 2006
  • A lot of small-scale reservoirs that is extravagant in whole country are controlled state or real conditionthat correct data about the practice contents is not equipped all up to now. In this study, YungNam districts that region Gyeong-Ju city reservoir is distributed much of when flow speedily choose 23 peace among 73 small scale reservoir and experimented. Acquired data every 5 seconds, and user E/S and user value TS for orthocenter to 1 second interval and executes present ondition measurement using RTK-GPS. Could was wave and state that reservoir of 15 places (about 65%) gives protective care that do 3D modelling with acquired data, and now correct contents about reservoir state past through comparative analysis with data. Also, area of full water and wave that analyze effective storage and area of full water of 23 places reservoir could know that 20.63%, effective storage decreased as 3.34%. I wish to contribute about analysis about present reservoir state through this and method the adminstration direction.

  • PDF

Analysis of Teacher's Needs on a Life-cycle System of the Educational Digital Contents through a Case Study of EDUNET (에듀넷 사례를 통한 교육용 디지털 콘텐츠 수명주기에 대한 교사 요구사항 분석)

  • Cha, Hyunjin;Hwang, Yunja
    • The Journal of Korean Association of Computer Education
    • /
    • v.22 no.3
    • /
    • pp.101-112
    • /
    • 2019
  • This study aims to draw implications on a life-cycle system of digital contents through a case study about EDUNET in order to maintain the quality and efficiency of the service for educational digital contents in the primary and secondary education area. To achieve the objective, lead teachers in EDUNET service participated in requirements analysis about the life-cycle of the digital contents, for example, contents utilization periods, the periods for being updated, etc. From the results, it was found that a systematic life-cycle framework should be established to re-evaluate the contents in service and provide a quality of contents, responding to consistent changes for educational environments in teaching-learning and for educational topics/directions, or according to educational content's substance such as curriculum or extra-curriculum. This study contributes to suggesting needs to implement the systematic management of contents based on a life-cycle system by analyzing user's requirements in order to provide user-friendly service for the K-12 educational digital contents.

Development of Ultra-Rapid Multiplex PCR Detection against 6 Major Pathogens in Honeybee (꿀벌 6종 주요 병원체에 대한 초고속 다중 PCR 검출법의 개발)

  • Lim, Su-Jin;Kim, Jung-Min;Lee, Chil-Woo;Yoon, Byoung-Su
    • Journal of Apiculture
    • /
    • v.32 no.1
    • /
    • pp.27-39
    • /
    • 2017
  • PCR-chip-based ultra-rapid multiplex PCRs for detection of six major infectious pathogens in honeybee were developed. The 6 kinds of major infectious pathogens in honeybee included Paenibacillus larvae causing American Foulbrood, Melissococcus plutonius causing European Foulbrood as bacteria, Ascosphaera apis (Chalkbrood), Aspergillus flavus (Stonebrood), Nosema apis and Nosema ceranae (Nosemosis) as fungi. The developed PCR-chip-based ultra-rapid multiplex PCR showed successful amplification for all six major pathogens in the presence of more than $10^3$ molecules. The time for confirming amplification (Threshold cycles; Ct-time) was about 7 minutes for two species, and about 9 minutes for four species. Total 40 cycles of PCR took 11 minutes 42 seconds and time for melting point analysis was 1 minute 15 seconds. Total time for whole PCR detection was estimated 12 minutes 57 seconds (40 cycles of PCR and melting point analysis). PCR-chip based ultra-rapid multiplex PCR using standard DNA substrates showed close to 100% accuracy and no false-amplification was found with honeybee genomic DNA. Ultra-rapid multiplex PCR is expected to be a fast and efficient pathogen detection method not only in the laboratory but also in the apiary field.

An application of Smoothed Particle Hydrodynamics on intake system analysis in a dam (입자법을 이용한 댐 취수 운영의 3차원 해석 적용)

  • Kim, Sunghoon;Cho, Kwangjoon;Park, Chungik;Moon, Sukju;Kim, Jongchan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.92-92
    • /
    • 2019
  • 최근 기존의 격자방식의 해석 방법을 벗어나 해석 영역에 대한 분할을 별도로 고려치 않는 수치기법의 실무적 적용사례가 증가 하고 있으며, 이러한 방식중 SPH(Smoothed Particle Hydrodynamics) 방식이 근자에 수자원 분야에서도 도입되어 관수로 및 개수로 해석 또는 복합해석 등에 활용된 바 있다. 최초 도입된 무격자방식의 모형들은 주로 복잡한 형상을 지니는 유체기계 등에 활용성이 높았던 바, 큰 규모의 해석 도메인을 가지는 수자원 분야에서의 SPH의 실무적용 평가와 효율성의 확보를 위해서, 본 연구는 국내 댐을 시범 대상으로 하여 SPH 수치해석 툴을 적용하고자 하였다. 분석 대상댐은 국내 P댐으로서 관리수위의 변동은 크지 않으나, 댐 직상류의 만곡이 심하고 다수의 대규모 취수구를 가진 곳으로 상시 발전방류 및 수시 댐 수문방류에 의해 유체의 흐름이 2,3차원의 복잡성을 띄고있기 때문에, 3차원 전산유체역학 Tool의 적용이 적절한 것으로 판단하였다. 해석을 위해 하류경계조건을 댐축과 문비로 설정하였고 상류 1km까지를 해석의 도메인으로 설정하였다. 소요시간을 줄이기 위해 여러 번의 모의를 거쳐 입자의 평균 입경은 0.6m로 제안하고 시격은 1초 미만(평균 0.5초)로 설정하였다. 수문 및 발전방류는 해당댐의 1~2년 빈도 수준에 해당하는 $5,000m^3/s$ 이하의 유량을 기준으로 하여 모의를 수행하였다. 모의의 안정성을 확보한 이후에는 해당 댐지역의 하류영향을 고려한 문비제어를 반영한 다양한 방식의 수문운영 및 취수지점의 순간 수위 영향을 검토하였다. 그 결과로 본 모의에서는 특정한 수문의 운영 조건에서는 댐수위 계측지점과 인근 취수지점 간에도 0.2m 수준의 순간 수위차가 발생할 수 있음을 보였으며, 이는 경우에 따라 취수시설의 일시적 장애요소로 발생할 수 있음을 의미한다. 따라서, 현재의 취수구조물과 문비운영 특성에 따라 발생가능한 취수장애를 줄일 수 있는 운영조건의 탐색을 위해서 수치모의를 추가로 하였으며, 이 때 댐축 상류의 유속분포에 대한 추가 검토도 수행하였다. 다만, 댐에서 방류시 하류조건에 대한 검토는 추후 보강되어야 할 것으로 판단된다.

  • PDF

Economic Analysis of Two-Layer Quiet Asphalt Pavement Considering Noise Cost Benefits (소음 편익 비용을 고려한 복층 저소음 아스팔트 포장의 경제성 분석)

  • Kang, Haet Vit;Park, Ki Sun;Kim, Nak Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1581-1587
    • /
    • 2014
  • Two-lalyered quiet asphalt pavements are well known for their noise reduction capabilities compared to the conventional ones. This study was conducted to analyze the economic effects on two-layered quiet asphalt pavement rather than on one-layered. Noise prediction was performed on the data surveyed from the two-layered quiet asphalt pavement. In addition, the economic analysis was executed considering cost benefits using the noise prediction result. The permeability test was also investigated to evaluate the clogging recovery of two-layered quiet asphalt pavement. Analysis results revealed that the construction cost of two-layered quiet asphalt pavements was cheaper than that of the conventional soundproof walls. The two-layered quiet asphalt pavement with simulated clogging conditions was satisfied the permeability requirements of the permeable asphalt pavements. The permeability test results showed that the permeable time was recorded as 6.77 seconds for one cycle of cleaning job with 400 mL of water.

A Study on Efficient Management of Traffic Flow on Intersection (효율적인 신호교차로 운영방안 연구)

  • Hwang, In-Sik;Kim, Su-Sung;Oh, Se-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.3
    • /
    • pp.45-55
    • /
    • 2009
  • This study was intended to increase efficiency of traffic flow management on intersection. The result suggested to establish a left-turn at own risk lane to increase efficiency of traffic flow on intersection. The scope of the research was to investigate the geometric structure of a signal-controlled intersection, traffic volume(density) with respect to directions and traffic signal display, and to select a signalling intersection into which a car waiting for a traffic signal enters by adjusting the display sequence of traffic signal. The delay with respect to directions and for the whole intersection was compared for the current situation and an improvement plan. Using TSIS, a traffic analysis package, the traffic situation on an intersection was investigated. Based on the simulation result for Seok-Jeon intersection in Ma-San selected from the field investigation of intersections to which an improvement plans would be applicable, the waiting time in the direction without a entering traffic signal was decreased to be 78.6 seconds per car and that of the direction expecting the increase of waiting time was increased by 4 seconds per car only. It was confirmed that the waiting time for the whole intersection was improved.

  • PDF