• Title/Summary/Keyword: 초음파 주사

Search Result 198, Processing Time 0.022 seconds

In-situ Rock Stress Measurement at the Water Tunnel Sites in the OO Oil Storage Facility with Hydraulic Fracturing Method (수압파쇄법을 이용한 OO 원유비축시설 내 수벽 터널에서의 초기응력 측정)

  • Bae, Seong-Ho;Kim, Jae-Min;Kim, Jang-Soon;Lee, Young-Ho
    • Tunnel and Underground Space
    • /
    • v.18 no.1
    • /
    • pp.80-89
    • /
    • 2008
  • The influence of in-situ rock stress on the stability of an underground rock structure increases as the construction depth become deeper and the scale of a rock structure become larger. In general, hydraulic fracturing stress measurement has been performed in the surface boreholes of the target area at the design stage of an underground structure. However, for some areas where the high horizontal stresses were observed or where the overstressed conditions caused by topographical and geological factors are expected, it is desirable to conduct additional in-situ stress measurement in the underground construction site to obtain more detailed stress information for ensuring the stability of a rock structure and the propriety of current design. The study area was a construction site for the additional underground oil storage facility located in the south-east part of OO city, Jeollanam-do. Previous detailed site investigation prior to the design of underground structures revealed that the excessive horizontal stress field with the horizontal stress ratio(K) greater than 3.0 was observed in the construction area. In this study, a total of 13 hydraulic fracturing stress measurements was conducted in two boreholes drill from the two water tunnel sites in the study area. The investigation zone was from 180 m to 300 m in depth from the surface and all of the fracture tracing works were carried out by acoustic televiewer scanning. For some testing intervals at more than 200 m ind depth from surface, the high horizontal stress components the horizontal stress ratio(K) greater than 2.50 were observed. And the overall investigation results showed a good agreement with the previously performed test.

이방성대수층에서의 투수량계수 텐서

  • 강철희;이대하;이철우;김용제;채병곤;우남칠
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.172-175
    • /
    • 2001
  • 이 연구에서는 5개의 시추공에 대한 양수시험을 실시하여 대수층의 수리학적 이방성과 지하수의 주 유동방향을 규명하고자 하였다. 코아검층 및 초음파주사검층을 통해 각각의 공에 대한 균열방향을 결정하고 이를 토대로 통합해본 결과 크게 세 방향의 균열군이 집중성을 보였다. 가장 빈도가 높은 균열의 방향은 N0$^{\circ}$~40$^{\circ}$E/30$^{\circ}$~50$^{\circ}$SE 그리고 N30$^{\circ}$~ 80 $^{\circ}$W/20$^{\circ}$~50$^{\circ}$ NE이 방향이 함께 나타났으며 두 번째 균열의 방향은 N0$^{\circ}$ ~50$^{\circ}$E/60$^{\circ}$ ~80$^{\circ}$NW로 나타났다. 세 번째 방향은 N30$^{\circ}$~50 $^{\circ}$W/70$^{\circ}$~80$^{\circ}$SW방향의 균열로 구성된다. 이처럼 지표하에서는 크게 세 방향의 균열이 다른 방향을 보이는 균열에 비해 상대적으로 큰 빈도를 가지며 발달하고 있음을 알 수 있다. 대수층이 이방성이고 균질하다는 가정하에 양수시험을 실시하여 각각의 공에 대한 최대 투수량계수 ( $T_{{\varepsilon}{\varepsilon}}$)와 최소 투수량계수 ( $T_{ηη}$)값을 산출하고 주 텐서방향 ($\theta$)을 결정하였다. 그 결과 BH-1, BH-4, BH=5공을 제외한 BH-2, BH-3호공에서의 이방성 투수량계수텐서값은 이 논문의 가정인 대수층이 이방성이고 균질하다는 가정에 일치하지 않았다. 따라서 원형좌표계에 도시하였을 때 다른 공에 비해서 비균질성이 심한 결과로 인해 이방성타원체 에서 많이 벗어남을 보였다. 이로인해 3개의 공 BH-1, BH-4, BH-5호공을 사용하여 대수층의 이방성을 분석하여 보았다. BH-1호공에서의 $T_{{\varepsilon}{\varepsilon}}$는 171.90 $m^2$/day, $T_{ηη}$는 71.0l $m^2$/day이고 주 텐서방향은 Nl5.39$^{\circ}$ E로 나타났다. BH-4호공의 $T_{{\varepsilon}{\varepsilon}}$는 268.20 $m^2$/day, $T_{ηη}$는 28.75 $m^2$/day이고 주 텐서방향은 N7.55$^{\circ}$E이며 BH-5호공에서의 $T_{{\varepsilon}{\varepsilon}}$는 168.40 $m^2$/day, $T_{ηη}$는 66.80 $m^2$/day이고 주 텐서방향은 N76.59$^{\circ}$E로 나타났다. 이처럼 연구지역에서의 각각의 공에 대한 투수량계수텐서는 서로 다르게 나타났으며 이에 따른 주 텐서방향도 서로 다름을 알 수 있다.

  • PDF

Physical Properties of and Joint Distribution Within the Cheongju Granitic Mass, as Assessed from Drill-core and Geophysical Well-logging Data (시추 및 물리검층자료의 상관해석을 통한 청주화강암체의 물성 정보 및 절리 분포)

  • Lee, Sun-Jung;Lee, Cheol-Hee;Jang, Hyung-Su;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.15-24
    • /
    • 2011
  • To clarify the distribution of joints and fracture zones in the Cheongju granitic mass, we analyzed drill-core and geophysical well-logging data obtained at two boreholes located 30 m from each other. Lithological properties were investigated from the drill-core data and the samples were classified based on the rock mass rating (RMR) and on rock quality designation (RQD). Subsurface discontinuities within soft and hard rocks were examined by geophysical well-logging and cross-hole seismic tomography. The velocity structures constructed from seismic tomography are well correlated with the profile of bedrock depth, previously mapped from a seismic refraction survey. Dynamic elastic moduli, obtained from full waveform sonic and ${\gamma}-{\gamma}$ logging, were interrelated with P-wave velocities to investigate the dynamic properties of the rock mass. Compared with the correlation graph between elastic moduli and velocities for hard rock at borehole BH-1, the correlation points for BH-2 data showed a wide scatter. These scattered points reflect the greater abundance of joints and fractures near borehole BH-2. This interpretation is supported by observations by acoustic televiewer (ATV) and optical televiewer (OTV) image loggings.

Fabrication of Photocatalytic $TiO_2$ Thin Film Using Aerosol Deposition Method (Aerosol Deposition 법을 이용한 광촉매 $TiO_2$ 박막 제조)

  • Choi Byung-Kyu;Min Seok-Hong;Kim Jong-Oh;Kang Kyong-Tae;Choi Won-Youl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.4 s.33
    • /
    • pp.55-59
    • /
    • 2004
  • We fabricates the $TiO_2$ thin film from anatase phase $TiO_2$ powder having good photocatalytic property using aerosol deposition method at room temperature. Aerosol deposition method, which sprays an aerosol powder with ultrasonic velocity and deposits a thin film on substrate at low temperature, has the advantages of low thermal stress and low cost. To fabricate the $TiO_2$ thin film, the aerosol bath pressure and chamber pressure were 500 torr and 0.4 torr, respectively. The difference of aerosol bath pressure and chamber pressure accelerated the $TiO_2$ nano powder to ultrasonic velocity through the nozzle of $0.4 mm{\times}10 mm$ and $TiO_2$ thin film was finally formed. SS mesh with diameter of 50 mm was used as a substrate to apply the $TiO_2$ thin film to water quality purification. The raw powder was dehydrated for the good dispersion of $TiO_2$ powder. To suppress the formation of second particle, the powder was dispersed for 90 min in alcohol bath by ultrasonic treatment and desiccated. The grain size of $1 {\mu}m$ was observed in $TiO_2$ thin film deposited on SUS mesh by scanning electron microscopy (SEM). The anatase phase of $TiO_2$ thin film was also observed by X-ray diffraction (XRD) and the anatase phase of raw powder was nicely maintained after aerosol deposition. The results are applicable to water treatment filter having photocatalytic reaction.

  • PDF

Highly-permeable SBS/UiO-66 Mixed Matrix Membranes for CO2/N2 Separation (CO2/N2 분리를 위한 SBS/UiO-66 기반의 고투과성 혼합 매질 분리막)

  • Kim, Young Jun;Moon, Seung Jae;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.30 no.5
    • /
    • pp.319-325
    • /
    • 2020
  • In this study, we developed mixed matrix membranes by blending thermoplastic elastomer, i.e. polystyreneblock-polybutadiene-block-polystyrene (SBS) block copolymer with the synthesized UiO-66 particles for CO2/N2 gas separation. To investigate the effect of UiO-66 particles in the SBS matrix, we prepared different mixed matrix membranes (MMMs) by varying the mass ratio of SBS and UiO-66 in the blend. To fabricate well-dispersed UiO-66, the SBS/UiO-66 mixture was sonicated and stirred thoroughly. The physico-chemical properties of prepared membranes were characterized by Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscope (SEM). The gas separation performance was measured by time-lag method. The permeability of the MMMs increased significantly as the content of UiO-66 increased, but the CO2/N2 selectivity did not decrease significantly. The membranes containing 20% of UiO-66 particles showed the best performance with the CO2 permeability and CO2/N2 selectivity of 663.8 barrer and 13.3, respectively. This result showed performance closer to upper bound than pure SBS membrane in the Robeson plot, as the added UiO-66 particles did not significantly sacrifice selectivity and more than doubled gas permeability.

Management of Urinary Tract Infections in Children: A Survey of Pediatricians in Daegu City (대구지역 소아청소년과 의사들의 요로감염 관리 실태분석)

  • Lee, Sang Su;Kang, Seok Jeong;Lee, Jae Min;Cho, Min Hyun;Park, Yong Hoon
    • Childhood Kidney Diseases
    • /
    • v.16 no.2
    • /
    • pp.95-101
    • /
    • 2012
  • Purpose: Recently, many evidence-based guidelines for the management of urinary tract infection (UTI) have been developed because of the importance of proper management. However, there is a lack of data regarding how pediatricians manage UTIs in Korea. Therefore, we surveyed pediatricians to determine whether they manage UTIs in an appropriate manner. Methods: A postal questionnaire survey of 78 pediatricians practicing in Daegu city was performed. Subjects were asked about diagnosis, imaging studies, treatment, and prevention of UTIs. Results: Most of the respondents (94.8%) performed urinalysis to diagnose UTI in febrile children with an unknown fever focus. However, many preferred inaccurate collection methods, such as bagged urine collection, and did not obtain urine cultures. The most frequently performed imaging modality was renal-bladder ultrasonogram. Orally administered antibiotics were preferred unless admission was needed. After diagnosis of UTI, the pediatricians usually provided information to caregivers about the disease itself and supplementary treatment. Of the respondents, only 28.6% had their own guidelines for management of vesicoureteral reflux. Conclusion: Most pediatricians suspected UTI in febrile children with an unknown focus appropriately. Nevertheless, the fact that many pediatricians preferred inaccurate urine collection methods and did not perform sufficient imaging studies to detect associated abnormalities likely resulted in overtreatment due to false-positive diagnosis of UTI and a low probability of ruling out genitourinary anatomical problems. To improve the quality of management of UTI, pediatricians should follow scientific and evidence-based guidelines.

Mineralogy of Size Fractions in Sancheong Kaolin and Its Origin (산청고령토 입도분리시료들의 광물조성 변화와 그 원인)

  • Jeong, Gi-Young;Kim, Soo-Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.22-31
    • /
    • 1992
  • The Sancheong kaolin was fractionated into 9 size fractions by wet sieving, sedimentation, and centrifugation. The systematic X-ray diffraction combined with electron microscopy shows that the clay mineral composition of each size fraction is related to the original fabric of kaolin. Minerals such as halloysite (10${\AA}$), kaolinite, illite, and goethite which were formed by procipitation from solution are generally concentrated in the finer fractions, whereas verniculite which was formed by pseudomorphic transformation from other primary minerals are concentrated in the coarser factions. Kaolinits of various types which were formed by precipitation or transformation show a wide size range but they are generally concentrated in the coarser fractions. Halloysite or halloysite-kaolinite clusters in coarse fractions are the fragmentation products of the walls of original boxwork clusters in coarse fractions are the fragmentation products of the walls of original boxwork kaolin which escaped the complete dispersion even through the grinding, ultrasonic agitation, and chemical treatment. Separation of fully hydrated halloysite and kaolinite was possible by systematic wet size fractionation. The coarse-grained minerals such as vermiculite and kaolinite are usually removed during the preparation of clay fraction smaller than 2${\mu}m$, whereas the fine-grained minerals such as illite and goethite are overlooked in X-ray diffraction of the bulk samples because of their minor contents. The systematic wet size fractionation is needed for understanding of the exact mineralogy of kaolin of weathering origin.

  • PDF

Friction Welding of Ni-Base ODS Alloy Prepared by Mechanical Alloying (기계적 합금법으로 제조된 Ni기 산화물 분산강화 합금의 마찰압접에 관한 연구)

  • 강지훈;박성계;김지순;권영순
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 1994.10b
    • /
    • pp.15-15
    • /
    • 1994
  • M MA ODS 합금의 보다 폭넓용 실용확훌 위해 크게 요구되고 있는 적정 접합기술 개발의 한 방안£로, 마찰압접(Friction Welding) 방법의 가능성옳 조사하기 위하여 마찰압력과 시간, 마 찰 후 접촉압력(Upset Pressure) 풍을 다양하게 변화시켜 접합체톨 제조한 후, 접합체 강도에 대한 인장시험과 접합계연의 결합 및 미세구조에 대한 현미경 관찰, EDS에 의한 원소분석, 접 합이옴부의 경도분포와 파단면 분석 풍율 행하였다. 실험에 사용된 모재는 기계적 합금법으로 제조된 Inca사의 Ni기 MA 754 합금이었으며, 직경 l 10 mm, 길이 50 mm로 가공한 후, 아세통£로 초음파 세척하여 접합에 사용하였다. 접합온 브 레이크식 마찰압접기틀 사용하여 행하였으며, 회전시험편의 회전수는 2400 rpm이었A며, 다른 한쪽의 고정시험편과의 마찰압력 및 마찰시간온 각각 50 - 500 MPa과 1-5초로, 또한 업셋압 력도 50 - 600 MPa로 변화시켰다. 이때 업셋압력은 모든 시편에 대해 일정하게 6초동안 가하 였다. 얻어진 접합체는 각 압접조건 당 2개 이상의 접합시험편에 대해 상온 인장강도톨 측정하 였으며, 파단이 일어난 위치를 확인한 후 파면에 대한 분석율 주사전자현미경(SEM)과 에너지 분산형 분광분석기mDS)릎 사용하여 행하였다. 컵합이옴부의 첩합성올 확인하기 위하여, 접합 체를 접합변에 수직으로 절단, 연마한 후 광학현미경과 SEM, EDS 퉁으로 관찰, 분석하여 접 합부의 형상과 결합형성 여부, 접합계면의 미세조직 퉁옳 조사하였다. 또한 마찰압접에 따론 모재와 접합계연부의 경도분포훌 접합이옴부로부터 모재쪽으로 일정 간격율 두어 마이크로 비 커스 경도기로 측정, 조사하였다. 이상의 설험 결과, 다옴과 같온 결론옳 얻었다. ( (1) 접합체 강도가 모채 강도의 95% 이상이 되는 양호한 렵합체흩 얻기 위한 마찰압력 조건 온, 2400 rpm의 회전속도와 6초의 업셋압력 유지시간에서 마찰압력과 업셋압력, 그리고 마찰시 간이 각각 400 MPa 이상과 500 MPa 이상,2초입율 확인하였다. ( (2) 컵합이옴부의 관찰 결과, 모든 마찰압접 조건에서 컵합이옴부는, 기폰 모재의 texture 조직 을 유지하고 있는 모재부 영역(영역 ill)과 첩합계면부에 인접하여 업셋압력이 주어질 때 단조 효과에 의해 계연 외부로 metal flow가 일어나면서 형성된 영역 II, 매우 미세한 결정립으로 구성된 중앙부의 영역 1 로 이투어져 있옴융 확인하였다. ( (3) 최적접합조건이 충족되지 않온 경우, 접합부의 영역 I 에서 관찰된 void와 균열, 불균일한 접합계면 통의 접합결함에 Al과 Y. Ti 퉁£로 구성된 산화물률이 용집되어 있옴을 확인하였 다-( (4) 접합체의 파단 양상온 크게 접합부 파단과 모재부 파단, 이률의 혼합형 파단i로 나눌수 있었다. 모재부 파단의 경우, 파단면이 매끄럽고 파변상의 결정립도 매우 미세하였으며, 산확물 의 용집도 찾아보기 어려웠 나, 접합부 파단의 경우에는 파변의 굴곡이 비교척 심하고 연성 입계파괴의 형태를 보였£며, 결정립도 모채부 파단의 경우에 비해 조대하였다. 조대하였다.

  • PDF

Surface Characteristics of Dental Casting Palladium Alloy for Replacement of Gold Alloy (금대체를 위한 치과주조용 파라듐 합금의 표면특성)

  • Park, Seon-Yeong;Hwang, In-Jo;Yu, Ji-Min;Park, Min-Gyu;Im, Sang-Gyu;Bae, Ho-Seong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.196-196
    • /
    • 2016
  • 치과나 기공소로부터 높은 원가로 인한 재료선택에 어려움을 겪고 있어 귀금속 금합금의 물성을 가질 수 있도록 하면서 가격급등으로 인한 문제 해결하기 위한 비귀금속 합금으로 대체가 필요하기에 이에 따른 연구가 이루어져 국산 제품의 상품화를 위해 파라듐을 이용하여 적합한 새로운 합금을 개발하는 것이 필요하다. 치과용 골드합금은 미국치과의사 협회의 구정에 의하면 1형부터 4형까지 분류하고 있으며 3형에 해당하는 강도와 기계적인 특성을 갖도록 파라듐으로 대체하는 연구가 진행중이거나 시판되고 있다. 따라서 본 연구에서는 2형, 3형 및 4형을 대체가능하도록 팔라듐을 기반으로 한 새로운 합금을 설계하고 합금의 성분원 소인 Au(1~5), Pd(20~25), Ag(70~75), In(1.5) 및 Zn(2)등으로 조성을 변화시켜 측량 후 합금을 제조하기 위하여 아르곤 분위기하의 진공아크용해로를 이용하여 용해하였다. 정량된 금속을 진공아크 용해로에 장입하고 용해는 균질한 합금이 되도록 최소한 6회 이상 용융을 실시하며 합금성분의 손실이 발행하지 않도록 보정을 하였다. 합금의 미세조직 관찰을 위하여 샘플을 고속 다이아몬드 정밀 절단기(Acculom-5, STRUERS, Denmark)를 이용하여 절단한 후 2000 grit의 Sic 연마지에서 단계적으로 $0.3{\mu}m$ 알루미나 분말까지 연마한 후 초음파 세척을 하였다. 준비한 시편은 KCN과 $(NH_4)_2S_2O_8$을 1:1로 혼합한 부식액으로 에칭한 후 OM과 SEM을 이용하여 조직을 관찰하였으며 각 샘플의 성분변화는 EDS 분석을 통해 확인하고 결정구조는 XRD를 사용하여 분석하였다. 경도시험은 비커스경도시험기를 이용하여 5kg의 하중을 30초간 작동시켜 압흔을 연결된 micron으로 평균값을 측정하였다. 각 시편의 부식거동은 POTENTIOSTAT(Model PARSTAT 2273, EG&G, USA)을 이용하여 구강 내환경화 유사한 $36.5{\pm}1^{\circ}C$의 0.9% NaCl에서 실시하였다. 인가전위는 -1500mV에서 1000mV까지 1.67 mV/min의 주사속도로 인가하여 시험을 수행하였으며 분극곡선으로부터 부식전위와 부식전류밀도 및 부동태영역의 전류밀도로 금속의 용출거동을 조사하였으며 부식이 끝난 시편은 FE-SEM과 EDS를 사용하여 조사하였다. 기계적인 특성은 Pd-Ag에 3wt%의 Au를 첨가한 합금이 Pd-Ag에 1.5wt%합금을 첨가한 경우에 비하여 기계적인 특성이 증가하고 내식성이 크게 증가하였다. 이들 합금에 Cu를 11wt%를 첨가한 경우는 비커스경도가 200이상으로 높게 나타났지만 내식성이 크게 감소하였다.

  • PDF

Improvement of Endoscopic Image using De-Interlacing Technique (De-Interlace 기법을 이용한 내시경 영상의 화질 개선)

  • 신동익;조민수;허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.469-476
    • /
    • 1998
  • In the case of acquisition and displaying medical Images such as ultrasonography and endoscopy on VGA monitor of PC system, image degradation of tear-drop appears through scan conversion. In this study, we compare several methods which can solve this degradation and implement the hardware system that resolves this problem in real-time with PC. It is possible to represent high quality image display and real-time processing and acquisition with specific de-interlacing device and PCI bridge on our hardware system. Image quality is improved remarkably on our hardware system. It is implemented as PC-based system, so acquiring, saving images and describing text comment on those images and PACS networking can be easily implemented.metabolism. All images were spatially normalized to MNI standard PET template and smoothed with 16mm FWHM Gaussian kernel using SPM96. Mean count in cerebral region was normalized. The VOls for 34 cerebral regions were previously defined on the standard template and 17 different counts of mirrored regions to hemispheric midline were extracted from spatially normalized images. A three-layer feed-forward error back-propagation neural network classifier with 7 input nodes and 3 output nodes was used. The network was trained to interpret metabolic patterns and produce identical diagnoses with those of expert viewers. The performance of the neural network was optimized by testing with 5~40 nodes in hidden layer. Randomly selected 40 images from each group were used to train the network and the remainders were used to test the learned network. The optimized neural network gave a maximum agreement rate of 80.3% with expert viewers. It used 20 hidden nodes and was trained for 1508 epochs. Also, neural network gave agreement rates of 75~80% with 10 or 30 nodes in hidden layer. We conclude that artificial neural network performed as well as human experts and could be potentially useful as clinical decision support tool for the localization of epileptogenic zones.

  • PDF