• Title/Summary/Keyword: 초음파 주사

Search Result 198, Processing Time 0.027 seconds

Accuracy of the Glenohumeral Joint Injection According to the Approach (도달 방법에 따른 관절와상완 관절내 주사의 정확도)

  • Choi, Nam Yong;Lee, Kang Wook;Kim, Hyung Seok;Song, Hyun Seok
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.45-52
    • /
    • 2013
  • Purpose: We wanted to compare the accuracy between the blind anterior approach and ultrasound guided posterior approach, which are preferred in the present clinical practice for the glenohumeral joint injection. Materials and Methods: The consecutive 95 cases were included in that the glenohumeral joint injection was done in the university hospital and the medical record and ultrasonography were available. There were 52 cases which were injected by blind anterior approach (group I) and 43 cases who were injected by ultrasound guided posterior approach (group II). The injection was decided as accurate if the fluid was visualized in the posterior joint under the ultrasound. We evaluated the range of motion before and after 2 weeks of injection. A subjective satisfaction of the patients was interviewed at the 2 weeks after injection. Results: The accuracy of the glenohumeral joint injections of the group I and group II was 80.8% and 90.7%, respectively. The range of motion was improved for the all cases regardless of the approaches. At the 2 weeks after injection, the subjective satisfaction (better than good) was achieved in 73.7%. Conclusion: The accuracy of the blind anterior approach for the glenohumeral joint injection was 80.8%. The accuracy of the ultrasound guided posterior approach was 90.7%. In this comparative study by the one physician, the ultrasound guided posterior approach showed the better accuracy.

  • PDF

Assessment of the Rock Strength using Borehole Acoustic Scanner (초음파 주사검층 방법을 이용한 암반강도 평가에 관한 연구)

  • Lee Kwangbae;Heo Seung;Song Young-Soo;Song Seungyup;Kim Haksoo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.4
    • /
    • pp.225-233
    • /
    • 2004
  • The purpose of this study is to provide the geo-technical information by assessment of the in-situ rock strength using the reflected wave energy and travel time data acquired by the borehole acoustic scanner. In order to compare and analyze the relationship between the uniaxial compressive strength and the reflected wave energy, the laboratory test and the borehole acoustic scanning were conducted for the set of specimens, such as mortar, concrete, and rock samples which have different rock type. Finally, we verified the applicability of the reflected wave energy acquired by the borehole acoustic scanner to quantitatively estimate the in-situ rock strength.

Injection Therapy for Calcific Tendinitis of Shoulder Under the Sonographic Guidance (초음파하 극상근 석회화 건염 주사 요법)

  • Nam, Ki Young;Moon, Young Lae;Yang, Kyung Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.10-13
    • /
    • 2008
  • Purpose: To evaluate the efficiency of needling and injection technique without steroid for symptomatic calcific tendinitis of the shoulder. Material and Methods: We chose 12 symptomatic calcific tendinitis patients, whose ages ranged from 35 to 64. Procedure ware dry needling and injection of prolotherapic agent near the lesion. Results: All the case revealed prominent improvement without limitation of shoulder function, especially in active painful stage. Conclusion: Sonographic injection technique for calcific tendinitis would be one of the good modality not only for symptomatic relieve but also good functional recovery.

  • PDF

Three Dimensional Ultrasonographic Evaluation with Intra-articular Saline Injection in Rotator Cuff Tear (회전근 개 파열의 수술 전 3차원 초음파 검사에서 관절내 생리식염수 주사 후 검사의 정확도)

  • Yum, Jae-Kwang;Shin, Yong-Woon;Park, Shin-Seung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Purpose: The purpose of this study is to find out the accuracy and usability of the three dimensional ultrasonography in measuring the size of the rotator cuff tear, especially before and after the injection of normal saline into the glenohumeral joint. Materials and Methods: 14 patients of rotator cuff tear who were diagnosed and operated from August 2007 to September 2008 were included in this study and authors compared the size of rotator cuff tear measured with three dimensional ultrasonography with the real size measured intraoperatively. In preoperative ultrasonographic evaluation, horizontal and longitudinal length of rotator cuff tear before and after injection of normal saline intraarticularly. During the arthroscopic operation the size of tear was measured by passing a Kirschner wire through a spinal needle and direct measure was performed in open surgery. Results: The average difference was 8 mm in horizontal and 1.9 mm in longitudinal length of tear without saline injection between ultrasonographic and intraoperative measure. The average difference was 4.1 mm in horizontal and 1.6 mm in longitudinal length of tear after the normal saline injection. Conclusion: In three dimensional ultrasonographic evaluation in rotator cuff tear, intraarticular normal saline injection would produce more accurate results.

  • PDF

Ultrasound-Guided Shoulder Injections (초음파 유도하 견관절 주사요법)

  • Moon, Young Lae;Jun, Yong Cheol;Sun, Jae Myeong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.393-401
    • /
    • 2019
  • The shoulder pain is one of the most common problems to orthopaedic surgeons in clinic. Among therapeutic modality used to manage this pain, joint and periarticular injection, as well as suprascapular nerve block, show good clinical outcome. Ultrasound guidance is a safe technique, increasing the safety and accuracy of the procedure and reducing complications. An accurate understanding of the surface anatomy is important in performing the ultrasound-guided shoulder injections. This article aims to describe the surface anatomy and sono anatomy of both the shoulder and the surrounding structures and also summarize different infiltration techniques and peripheral nerve blocks.

Position Control Technique of Ultrasonic Scanner for an Automated Ultrasonic Testing Using Surface Wave (표면파를 이용한 자동 초음파탐상검사 주사장치의 위치제어 기술)

  • Lee, Jong-Po;Park, Chul-Hoon;Um, Byong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.30-37
    • /
    • 2003
  • In order to replace the manual ultrasonic testing(UT) with an automated UT(AUT), a scanner which enables us to control the positions of a transducer is essential. Encoders have been commonly used to obtain the position information from the conventional scanners controlled by motor. Encoders have various advantages in many aspects. However, if the slip of motor wheel occurs during scanning, various errors are involved in the position accuracy. Thus, the position information of encoders becomes meaningless in case of slip. The reliability of AUT results nay become serious problem. Hence, slip must be avoided, but it can not be completely avoided at present time. In this paper, a new idea that surface wave is used to solve this problem and replace encoders has been proposed. It is shown that this idea can be employed in AUT scanner without encoders. That is, one transducer transmitting surface wave is fixed and the other transducer attached to the scanner receives UT signal. Then, computer calculates the present position of scanner based on the information given by surface wave. Thus, the movement of a scanner can be controlled by the amount of input based on the information obtained.

Application of Laser-based Ultrasonic Technique for Evaluation of Corrosion and Defects in Pipeline (배관부 부식 및 결함 평가를 위한 레이저 유도 초음파 적용 기술)

  • Choi, Sang-Woo;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.95-102
    • /
    • 2005
  • There are many tube and pipeline in nuclear power plant under high temperature and high pressure. Erosion and corrosion defects were expected on these tube and pipe-line by environmental and mechanical factors. These erosion and corrosion defects ran be evaluated by ultrasonic technique. In these study, Scanning Laser Source(SLS) technique was applied to detect defect and construct image. This technique also makes detection possible on rough and curved surfaces such as tube and pipe-line by scanning. Conventional ultrasonic scanning technique requires immersion of specimen or water jet for transferring ultrasonic wave between transducer and specimen. However, this SLS technique does not need contacting and couplant to generate surface wave and to get flaw images. Therefore, this SLS technique has several advantages, for complicated production inspection, non-contact, remote from specimen, and high resolution. In this study, SLS images were obtained with various conditions of generation laser ultrasound and receiving in order to enhance detectability of flaws on the tube. Stress corrosion cracks were produced on tube and images of stress corrosion cracks were constructed by using SLS technique.

Ultrasound-Guided Proliferative and Local Steroid Injection for Subacromial Bursitis (견봉하 점액낭염에서 초음파 하 증식과 국소 스테로이드 병합 주사 요법)

  • Nam, Ki Young;Moon, Young Lae
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.6-9
    • /
    • 2008
  • Purpose: To investigate the effectiveness of injection therapy in the treatment of subacromial bursitis. Materials and Methods: A total of 38 patients with sonographic confirmation of subacromial bursitis were recruited into this study. The shoulder abduction range of motion and visual analog scale (VAS) were compared before injections and 3 wks after the completion of injections. Results: The shoulder range of abduction before injection was $77.89{\pm}14.17$ degrees and improved to $148.68{\pm}13.39$ degrees 3 wks after the injection treatments (P<0.05). VAS before injection was $6.8{\pm}1.4$ and improved to $1.4{\pm}0.8$ 3 wks after the injection treatments (P<0.05). Conclusions: Ultrasound may be used as an adjuvant tool in guiding the needle accurately into the inflamed subacromial bursa. The ultrasound-guided injection technique can result in significant improvement in shoulder abduction range of motion in treating patients with subacromial bursitis.

  • PDF

Blind and Ultrasonography-guided Injection Therapy for Calcific Tendinitis of Supraspinatus (극상건 석회화 건염에 대한 맹검 주사요법과 초음파하 주사요법)

  • Moon, Young-Lae;Nam, Gi-Young;Noh, Kyung-Hwan
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.86-90
    • /
    • 2008
  • Purpose: To evaluate the differences between blindly and ultrasonography (US)-guided during multiple needling and dextrose injection technique for calcific tendinitis of shoulder. Materials and Methods: We chose 36 symptomatic calcific tendinitis patients, whose age ranged from 27 to 69. Our procedures were multiple needling and injection of dextrose over the lesion of calcific deposits. The bind injection group were 19 patients whose age ranged from 27 to 64-year-old (mean 52.2), and the US-guided injection group were 17 patients ranged from 31 to 69-year-old (mean 49.0). We compare these groups by VAS (visual analogue scale) and range of motion before and after procedures. Results: There is no difference between two groups in VAS and ROM before procedure (p>0.05). Two groups revealed significant improvement without limitation of shoulder function, however, the group under US-guided revealed better results than under blind (VAS:p=0.001, Flexion:p=0.000, Abduction:p=0.000, External rotation: p=0.016). Conclusion: Ultrasonography-guided procedure showed better results than blind, so the use of ultrasonography is more promising procedure.

  • PDF

Ultrasound-guided Intervention in Cervical Spine (경추부 초음파 유도하 중재술)

  • Moon, Sang Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.49-66
    • /
    • 2014
  • Traditionally, cervical interventions have been performed under fluoroscopy. But radiation exposure is the major concern when obtaining fluoroscopic images and even under real-time fluoroscopy with contrast media or CT guidance, some cases of serious spinal cord injuries, cerebellar and brain stem infarction have been reported by unintentional intra-arterial injections especially during the transforaminal root blocks. Recently, the use of ultrasound-guided cervical interventions have increased. Ultrasound offers visualization of soft tissues including major neurovascular structures and also allows to observe the spread of injectant materials around the target structure. Ultrasound is radiation free, easy to use and the image can be performed continuously while the injectant is visualized in real-time, increasing the precision of injection. Importantly, ultrasound allows visualization of major nerves and vessels and thus leads to improve safety of cervical interventions by decreasing the incidence of injury or injection into nearby vasculature. We therefore reviewed to investigate the feasibility of performing cervical interventions under real-time ultrasound guidance.

  • PDF