• Title/Summary/Keyword: 초음파 온도변화

Search Result 153, Processing Time 0.027 seconds

Feasibility of Ultrasonic Inspection for Nuclear Grade Graphite (원자력급 흑연의 산화 정도에 따른 초음파특성 변화 및 초음파탐상의 타당성 연구)

  • Park, Jae-Seok;Yoon, Byung-Sik;Jang, Chang-Heui;Lee, Jong-Po
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.436-442
    • /
    • 2008
  • Graphite material has been recognized as a very competitive candidate for reflector, moderator, and structural material for very high temperature reactor (VHTR). Since VHTR is operated up to $900-950^{\circ}C$, small amount of impurity may accelerate the oxidation and degradation of carbon graphite, which results in increased porosity and lowered fracture toughness. In this study, ultrasonic wave propagation properties were investigated for both as-received and degradated material, and the feasibility of ultrasonic testing (UT) was estimated based on the result of ultrasonic property measurements. The ultrasonic properties of carbon graphite were half, more than 5 times, and 1/3 for velocity, attenuation, and signal-to-noise (S/N) ratio respectively. Degradation reduces the ultrasonic velocity slightly by 100 m/s, however the attenuation is about 2 times of as-receive state. The results of probability of detection (POD) estimation based on S/N ratio for side-drilled-hole (SDHs) of which depths were less than 100 mm were merely affected by oxidation and degradation. This result suggests that UT would be reliable method for nondestructive testing of carbon graphite material of which thickness is not over 100 mm. In accordance with the result produced by commercial automated ultrasonic testing (AUT) system, human error of ultrasonic testing is barely expected for the material of which thickness is not over 80 mm.

Preparation of methylammonium lead halide perovskite thin films by dual feed ultrasonic spray method (이중주입 초음파분무법에 의한 메틸암모늄 할로젠화 납 페로브스카이트 박막의 제조)

  • Kim, Rock Yoon;Kim, Tae Huei;Park, Kyung Bong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.1
    • /
    • pp.6-11
    • /
    • 2019
  • Methylammonium lead halide ($MAPbX_3$, X = I, Br) thin films, used as the light absorber of perovskite solar cells, were prepared using the dual feed ultrasonic spray method. Going through a deposition at a substrate temperature of below $60^{\circ}C$ and then a final heat treatment at $75^{\circ}C$ for 5 minutes using dual feed ultrasonic spray method, $MAPbI_3$ single phase could be formed. Whereas undergoing a deposition at temperatures above $80^{\circ}C$, the spheroidal grains could be changed into rod-shaped fractal structures due to the decomposition of the perovskite phase. Furthermore, using the same method at a higher heat treatment temperature of $100^{\circ}C$, $MAPbI_{3-x}Br_x$ thin films could also be formed from $MAPbI_3$ and $MAPbIBr_2$ solution.

Measurement Method Using Change of Frequency Characteristics in Two-Layered Piezoelectric Transducer (2층 구조 압전 트랜스듀서의 주파수 특성 변화를 이용한 물리계측법의 제안)

  • Kim Joung-Ho;Kim Moo-Joon;Ha Kang-Lyeol;Lee Chae-Bong;Kim Chun-Duck
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.365-368
    • /
    • 2002
  • 수중에서와 같이 전자기파의 사용이 곤란한 환경에서 정보의 전달 방법으로 초음파를 사용하는 것이 일반적이다. 그러나 기존의 방법은 음파의 전파 경로 상에 있어서 잡음, 온도, 음속 등의 환경에 많은 영향을 받기 때문에 정확한 정보의 전달이 곤란한 경우가 있다. 본 연구에서는 전기적 용량으로 특성을 제어할 수 있는 2층 구조 압전 트랜스듀서에 있어서 전기적 용량 변화에 따른 공진 모드간의 효율 비의 변화를 이용하여 전파 경로 상의 환경 변화에 독립적인 원격 물리 계측법을 제안하고 그 가능성을 확인하였다.

  • PDF

Synthesis of spherical SiO2 using scaled-up ultrasonic pyrolysis process (스케일-업 된 초음파 분무 열분해 공정을 이용한 구형 SiO2 분말 합성)

  • Kang, Woo-kyu;Lee, Ji-Hyeon;Kim, Jin-Ho;Hwang, Kwang-Taek;Jang, Gun-Eik
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.1
    • /
    • pp.12-18
    • /
    • 2019
  • The spherical $SiO_2$ powders were synthesized by the scaled-up ultrasonic pyrolysis (USP). The aqueous $SiO_2$ sol, which contained 20~30 nm $SiO_2$ particles, was used as a precursor for the scaled-up USP. The effects of the USP operating conditions and precursor conditions were systematically investigated, including reaction temperature, gas flow rate, and the concentration of $SiO_2$ sol on the morphologies of synthesized $SiO_2$ particles. the synthesized $SiO_2$ particle showed a pseudo-crystal phase, spherical morphology, and a smooth surface. The size of the spherical $SiO_2$ particle decreased as both reaction temperature increased and precursor concentration decreased. In addition, the synthesized $SiO_2$ particle size was increased by increasing the gas flow rate. Lastly, the scaled-up USP was compared with the lab-scale USP based on the same process conditions. Due to a short retention time in the reaction tube during the USP process, the $SiO_2$ particle synthesized via the lab-scale USP showed a larger particle size.

A Study on the High Frequency Ultrasonic Attenuation Characterization in Artificially Aging Degraded 2.25Cr-1Mo Steel (2.25Cr-1Mo 강 인공 열화재의 고주파수 초음파 감쇠특성에 관한 연구)

  • Park, Ik-Keun;Park, Un-Su;Kim, Chung-Seok;Kim, Hyun-Mook;Kwun, Sook-In;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.439-445
    • /
    • 2001
  • The destructive method is reliable and widely used lot the estimation of material degradation but, it have time-consuming and a great difficulty in preparing specimens from in-service industrial facilities. Therefore, the estimation of degraded structural materials used at high temperature by nondestructive evaluation such as electric resistance method, replica method, Barkhausen noise method, electro-chemical method and ultrasonic method are strongly desired. Ultrasonic nondestructive evaluation technique has been reported good to attain efficiency of measurement, high sensitivity of measurement, and rapidity and reliability of result interpretation. In this study, it was verified experimentally the feasibility of the evaluation of degraded 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at $630^{\circ}C$ by high frequency longitudinal wave method investigating the change of attenuation coefficient by FFT analysis and wavelet transform. Because of carbide precipitation increase and spheroidization near grain boundary of microstructure to aging degradation, attenuation coefficient had a tendency to increase as degradation proceeded. It was identified possibly to evaluate degradation using the characteristics of high-frequency ultrasonics. Frequency dependence of ultrasonic attenuation coefficient to aging degradation appeared large, which made sure that attenuation coefficient is an important parameter for evaluation of aging degradation.

  • PDF

The Usefulness of Transesophageal Echocardiography During Heart Surgery (개심술을 시행하는 환자에서 경식도 심초음파의 이용)

  • 조규도;김치경
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1205-1213
    • /
    • 1997
  • This study reviewed useful aspects of the intraoperative transesophageal echocardiography among the patients in whom heart surgery were undertaken between January 1996 and July 1996 at St.Pauls hospital, Medical College of Catholic University, Seoul, Korea. During that period, 61 patients were operated on because of valvular heart disease(25 patients), coronary artery disease(22 patients), congenital heart disease(13 patients), and combined coronary artery disease and valvular heart disease(1 patient). Two patients(1 redo-VSD and 1 valvular heart diease) needed repeated aortic cross clamping and complementary procedures because of incomplete initial procedures. There was no incidence of air embolism. We could observe significant relationship of cardiac output monitoring methods either by thermodilution technique and transesophageal echocardiography by linear regression analysis(p<0.001). We tested myocardial response(percentage of systolic wall thickness, PSWT) with low dose dobutamine challenge to predict post-CABG myocardial perfusion. And the test showed statistically significant resp.onse(sensitivity 76%, specificity 94.7%, positive predictive value 95%, negative predictive value 75%). These results suggest that cardiac surgeon could draw more benefits by intraoperative transesophageal echocardiography.

  • PDF

Change of Solubilization Characteristics of Rice Straw by Different Pre-treatments (전처리 방법에 따른 볏짚의 가용화 특성 변화)

  • Hong, Seung-Gil;Shin, JoungDu;Heo, Jeong-Wook;Park, Woo-Kyun;Kwon, Soon-Ik;Park, Noh-Back;Shin, Hyun-Seon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.1
    • /
    • pp.71-77
    • /
    • 2012
  • In order to find a feasibility of applying an agricultural biomass to the anaerobic digestion system, the effects of pre-treatment of rice straw was investigated by different sizes,temperatures, ultrasonic frequencies, and with/without NaOH treatment on the change of soluble organic matter, which is generated most dominantly in Korea. It was observed that SCOD(soluble chemical oxygen demand) as the index for the decomposition of rice straw increased with the smaller particle size, higher reaction temperature and alkali treatment. With treatment of 5% NaOH, it was shown that the highest concentrations of SCOD were observed at 9,000 mg $L^{-1}$ and 6,000mg $L^{-1}$ at $35^{\circ}C$ and $55^{\circ}C$, respectively. Agitating with ultrasonic irradiation could be enhanced SCOD of rice straw less than 3 cm with 40 kHz of ultrasound. Optimal RPM in this study was at 150 rpm regardless of reaction temperatures.

Development of the Image Stage Gauge using the Image Process Technique (영상처리기술을 이용한 영상수위계 개발)

  • Kim, Won;Kim, Chi-Young;Kim, Dong-Gu;Lee, Chan-Joo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.500-504
    • /
    • 2006
  • 하천 수위 측정을 위해서 우물통을 기본으로 하는 부자식, 초음파식, 기포식, 압력식, 레이다식 등 다양한 장비가 사용되고 있다. 이와 같은 장비는 모두 간접적인 방법으로 수위를 측정하기 때문에 기준값을 바탕으로 보정이 필요하며, 장비의 특성에 따라 여러 가지 장단점을 지니고 있다. 부자식의 경우 오래 전부터 사용되어 안정적으로 수위를 측정할 수 있는 것으로 평가되고는 있으나 우물통 막힘 등으로 인해 오측 혹은 결측이 발생하는 경우가 있다. 최근에 많이 사용되고 있는 센서식 장비의 경우에는 센서에 대한 정기적인 보정이 필요하며, 일부 장비의 경우 온도에 따라 측정값이 변화하는 단점이 있다. 수위 측정 방식은 접촉식과 비접촉식으로 나누어 볼 수 있다. 접촉식의 경우 물속에 센서가 위치하고 있기 때문에 홍수시 센서 유실 및 고장의 우려가 있으며, 잦은 고장의 원인이 되기도 한다. 비접촉 방식인 초음파나 레이다 수위계의 경우 온도에 따라 보정이 필요하거나 수면과의 거리에 커지면 오차가 커지는 경향을 지니고 있다. 또한 이와 같은 간접방식에 의한 수위측정 방법은 수위가 많이 변화하는 경우 실제 수위와 측정되는 수위가 일치하는지를 확인하는 것이 불가능한 단점도 있다. 본 연구에서는 최근에 많이 일반화되고 있는 영상처리기술을 이용하여 자동적으로 수위를 측정하는 장비인 영상수위계를 개발하였다. 또한 개발한 영상수위계를 하천 현장에 적용하여 정확성을 평가하고 그 특징을 분석하였다. 영상수위계는 카메라에 의해서 수위표를 촬영하여 직접 수위값으로 변환하는 원리를 사용하고 있어서 기존 수위측정 시설과는 달리 수위표를 직접 눈으로 확인할 수 있는 장점이 있다. 이로 인해 수위표를 육안으로 확인할 수 있기 때문에 측정된 수위를 검증할 수 있어 수위측정의 정확성을 한층 높일 수 있다. 그리고 수위표 영상과 더불어 수위표 주변의 전체 영상을 동시에 촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 영상수위계는 우물통 등을 이용하는 기존 방법과 비교하여 구조물이 필요 없어 설치 비용이 저렴하고, 영상에 의한 하천 모니터링 기능을 자체적으로 가지고 있기 때문에 효율적이라고 할 수 있다.

  • PDF

Practical Application of Image Stage Gauge (영상수위계 실용화)

  • Kim, Won;Kim, Chi-Young;Lee, Chan-Joo;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.560-564
    • /
    • 2007
  • 하천 수위 측정을 위해서 우물통을 기본으로 하는 부자식, 초음파식, 기포식, 압력식, 레이다식 등 다양한 장비가 사용되고 있다. 이와 같은 장비는 모두 간접적인 방법으로 수위를 측정하기 때문에 기준값을 바탕으로 보정이 필요하며, 장비의 특성에 따라 여러 가지 장단점을 지니고 있다. 부자식의 경우 오래 전부터 사용되어 안정적으로 수위를 측정할 수 있는 것으로 평가되고는 있으나 우물통 막힘 등으로 인해 오측 혹은 결측이 발생하는 경우가 있다. 최근에 많이 사용되고 있는 센서식 장비의 경우에는 센서에 대한 정기적인 보정이 필요하며, 일부 장비의 경우 온도에 따라 측정값이 변화하는 단점이 있다. 수위 측정 방식은 접촉식과 비접촉식으로 나누어 볼 수 있다. 접촉식의 경우 물속에 센서가 위치하고 있기 때문에 홍수시 센서 유실 및 고장의 우려가 있으며, 잦은 고장의 원인이 되기도 한다. 비접촉 방식인 초음파나 레이다 수위계의 경우 온도에 따라 보정이 필요하거나 수면과의 거리에 커지면 오차가 커지는 경향을 지니고 있다. 또한 이와 같은 간접방식에 의한 수위측정 방법은 수위가 많이 변화하는 경우 실제 수위와 측정되는 수위가 일치하는지를 확인하는 것이 불가능한 단점도 있다. 본 연구에서는 최근에 많이 일반화되고 있는 영상처리 기술을 이용하여 자동적으로 수위를 측정하는 장비인 영상수위계를 개발하였다. 영상수위계는 카메라(CCTV 포함)에 의해서 수위표를 촬영하여 직접 수위값으로 변환하는 원리를 사용하고 있어서 기존 수위측정 시설과는 달리 수위표를 직접 눈으로 확인할 수 있는 장점이 있다. 이로 인해 수위표를 육안으로 확인할 수 있기 때문에 측정된 수위를 검증할 수 있어 수위측정의 정확성을 한층 높일 수 있다. 그리고 수위표 영상과 더불어 수위표 주변의 전체 영상을 동시에 촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 본 연구에서 개발한 영상수위계는 한강홍수통제소 관할의 전류, 청담대교 등 4개소 낙동강 홍수통제소 2개소, 지자체 등에 적용되었으며, 적용 결과 비교적 안정적이면서 정확하게 수위를 측정하는 것으로 나타났다. 한편 기존 CCD 카메라 이외에 CCTV를 이용한 영상수위계를 개발하여 영상의 화질 개선뿐 아니라 하천화상 감시 기능을 강화하였다.

  • PDF

The Changes of Sweating Area, Temperature and Blood Flow in the Upper and Lower Extremity after Hyperhidrosis Operations (다한증수술후 발한분포 및 상하지의 온도변화와 혈류량변화)

  • 김용환;장윤희;문석환;조건현;왕영필;김세화;곽문섭;김학희;장혜숙
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.456-460
    • /
    • 1999
  • Background: Thoracic sympathectomy for hyperhidrosis has been recognized as an effective treatment using thoracoscopic devices and operative techniques, but the satisfaction has decreased due to a compensatory hyperhidrosis. Therefore, the postoperative results and compensatory hyperhidrosis were analyzed. We also measured the temperature differences in the hand and foot during the preoperative and postoperative periods and measured the blood flow of upper and lower extremities. Material and Method: From December 1995 to July 1998, total of 47 patients with hyperhidrosis underwent sympathectomy via VATS at the Department of Thoracic and Cardiovascular Surgery, Kangnam St. Mary's Hospital. The patients were evaluated for preoperative and postoperative temperature changes on the finger and toe, and preoperative and postoperative blood flows were measured by the Doppler examination on the digital artery, radial artery and dorsalis pedis artery. Result: There were no operative deaths but some complications existed: 7 pneumothorax, 3 recurrence and 1 Honor syndrome. Ninety-five percent of the patients also had compensatory sweating especially in the trunk. There were 5 patients who regretted recurring the operation because of the compensatory sweating. Sweating decreased in 46% of the sole hyperhidrosis patients. The temperature difference between preoperation and postoperation was 1$^{\circ}C$ on the right hand side and 1.9$^{\circ}C$ on the left hand side(P<0.05). There was no significant temperature difference on the sole. Blood flow increased significantly in the palm, but no difference in the sole. Conclusion: In conclusion, thoracic sympathectomy for hyperhidrosis is a safe and effective treatment but satisfaction has been decreased by the compensatory sweating; therefore, it is important to thoroughly explain the compensatory sweating prior to surgery. Improvement of the plantar hyperhidrosis is not due to a physiological change, but to a psychological stability.

  • PDF