• Title/Summary/Keyword: 초음파 수술도

Search Result 476, Processing Time 0.026 seconds

Spinoglenoid Cyst Combined with SLAP Lesion Initially Missed with Ultrasonography - A Case Report - (초기 초음파 검사로 발견되지 않은 상부관절와순 전후 병변을 동반한 극관절와 낭종 - 증례보고 -)

  • Oh, Chung Hee;Oh, Joo Han;Kim, Sae Hoon;Chung, Seok Won;Kim, Joon Yub
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.33-37
    • /
    • 2011
  • Spinoglenoid cyst have been reported in small series in the orthopaedic literature in association with SLAP lesion, which is one of less common causes of shoulder pain. Authors experienced one case of spinoglenoid cyst with SLAP lesion initially missed with ultrasonographic examination and physical examination. This case was confirmed by MRI, EMG and arthroscopic surgery was done. When clinicians cannot find a definite cause of shoulder pain and decreased power of rotator cuff tendon with ultrasonographic examination, they need further study such as MRI and EMG with careful physical examination. Clinicians need to aware of the limitation of ultrasonography for spinoglenoid cyst especially, (1) cyst size is small, (2) location of cyst is too deep to detect and along the scapula spine from SLAP lesion.

  • PDF

Surgical Removal of Large Thrombus at the Suture Site of the Right Atriotomy after Atrial Septal Defect Closure Associated with Pulmonary Embolism -1case- (심방중격결손 수술 후 폐색전증을 동반한 우심방 절개 봉합 부위에서의 우심방 혈전의 수술적 치료 -1예보고-)

  • 황여주;안영찬;전양빈;이재웅;박철현;박국양;이창하
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.448-451
    • /
    • 2004
  • Report of right atrial thrombus complicating pulmonary embolism after cardiac surgery is rare. A 54-year-old woman operated on the atrial septal defect 10 months ago was admitted for left pleuritic pain and dyspnea. Multiple segmental perfusion defects were detected in lung perfusion scan. Transesophageal echocardiography showed a large mobile right atrial mass attached to the free wall of the right atrium with a stalk. Despite the intravenous heparinization for 13 days, follow-up echocardiography revealed the right atrial mass had not diminished in size. The mass which was confirmed as an organizing thrombus was excised under cardiopulmonary bypass. The patient recovered uneventfully and was discharged on warfarin therapy.

Cavitation suppression through the modification of spectral characteristics in the field of high intensity focused ultrasound (주파수 특성 변환을 통한 고강도 집속형 초음파 공동 현상의 억제)

  • 최민주
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.449-454
    • /
    • 1998
  • 전립선 비대증 및 각종 고형암 조직을 제거하기 위해 이용되는 고강도 집속형 초음파 시스템은 초음파의 조직에 대한 열 효과를 이용한다. 이 경우 수MPa의 고 압력 초음파를 사용하기 때문에 수술시 초음파에 의한 조직내의 공동 현상이 수반되고 이로 인해 초음파의 집속 효과가 감소하게 된다. 본 논문에서는 초음파 공동 현상을 억제하기 위하여 초음파의 주파수 특성을 고려하였다. 초음파의 크기는 일정하게 유지하면서 증가하는 주파수로 변조된 초음파와 비선형 고저파 (nonlinear harmonics) 성분을 포함한 왜곡된 초음파에 대한 기포의 반응을 Gilmore 기포 모델을 이용하여 관찰하였다. 초음파의 주파수 변조는 10 $\mu\textrm{s}$ 동안 초기 주파수 1 MHz부터 시작하여 7 MHz까지 선형적으로 증가하도록 하였다. 파형을 왜곡시키는 고저파 성분의 크기는 주파수에 역 비례 하도록 하였다. 초음파의 기본 주파수는 1 MHz로 하였고, 압력은 0.1 MPa과 1 MPa의 두 경우를 고려하였다. 초기 기포의 반경은 1 $\mu\textrm{m}$으로 하였고, 기포 주위의 유체는 물로 가정하였다. 시뮬레이션 결과로부터, 주파수를 변조시키거나 파형을 왜곡시킨 초음파에 대한 기포의 진동은, 동일한 압력의 정현파에 대한 경우 보다 작은 것으로 나타났다. 주파수 변조된 초음파에 반응한 기포의 진동은 압력이 낮을 때 (0.1 MPa), 변조된 주파수가 기포의 공진 주파수인 3 MHz 부근에서 최대치를 보이다가 이후 급격히 감소하는 경향을 보였다. 반면, 압력이 높아지면 (1 MPa) 기포의 진동은 주파수의 증가와 함께 감소하다가 3 MHz 이상으로 변조 될 경우, 유의한 변화를 보이지 않는 것으로 나타났다. 이 결과는 초음파의 적절한 주파수 성분 조절로 초음파 공동 현상을 일정 수준 억제할 수 있음을 시사한다. 고려가 수반되어야 할 것으로 보인다. 다음 내용을 정리해 보고자 한다.리해 보고자 한다.rc$ 구입할 때 중점적으로 살펴보는 사항은 신선도와 순수재래종 여부, 위생상태였다. 한편 소비자가 언제나 구입할 수 없다는 의견이 85.2%나 되어 원활한 공급과 시장조성이 아직 정착되지 않고 있었다. $\bigcirc$ 현재 유통되고 있는 재래종닭은 소비자 대부분이 잡종으로 인식하고 있었으며, 재래종과 일반육계와의 구별은 깃털색, 피부색, 정강이색등 외관상으로 구별하고 있었다. 체중에 대한 반응은 너무 작다는 의견이었고, 식품으로의 인식도는 비교적 고급식품으로 인식하고 있다. $\bigcirc$ 재래종닭고기의 브랜드화에 대한 견해는 젊고 소득이 높은 계층에서 브랜드화의 필요성을 강조하고 있다. $\bigcirc$ 재래종달걀의 소비형태는 대부분의 소비자가 좋아하였으나 아직 먹어보지 못한 응답자가 많았다. 재래종달걀의 맛에 대해서는 고소하고 독특하여 차별성을 느끼고 있었다. $\bigcirc$ 재래종달걀의 구입장소는 계란판매점(축협.농협), 슈퍼, 백화점, 재래닭 사육 농장등 다양하였으며 포장단위는 10개를 가장 선호하였고, 포장재료는 종이, 플라스틱, 짚의 순으로 좋아하였다. $\bigcirc$ 달걀의 가격은 200원정도를 적정하다고 하였으며, 크기는 (평균 52g)는 가장 적당하다고 인식하고 있으며, 난각색은 대부분의 응답자가 갈색을 선호하였다. $\bigcirc$ 재래종달걀의 구입시 애로사항은 믿을수 없고, 구입장소를 몰라서, 값이 싸다 등이었고, 앞으로 신뢰할 수 있고 위생적인 생산 및 유통체계가 확립될 경우 더 많이 소비하겠다는 의견이었다. $\bigcirc$ 재래닭 판매업소(식당)의 판매형태는 66.7%인 대부분

  • PDF

The Usefulness of Harmonic Scalpel During Pericardiectomy for Constrictive Pericariditis (교착성 심막염에 대한 심막절제술시의 Harmonic Scalpel의 유용성)

  • 김도형;이정철;정태은;한승세;이장훈;이동협
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.605-607
    • /
    • 2002
  • Harmonic Scalpel(Ethicon Endo-Surgery, Cincinnati, OH) has many advantages including no muscular stimulation, low heat, less smoke, easy hemostasis using ultrasound and good operation field. In patient with constrictive pericarditis, Harmonic Scalpel was beneficial during pericardiectomy.

The Use of Urokinase in Ischemic Free Tissue Transplantations - An Experiment Using the Ischemic Replanted Rabbit Ear Model - (허혈성 유리조직 접합술에서 Urokinase의 효용성 - 토끼 이개를 이용한 실험 -)

  • Lee, Jun-Mo
    • Archives of Reconstructive Microsurgery
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1995
  • 장시간 허혈상태의 토끼 이개를 실험대상으로 하여 유로키나제와 헤파린을 병용 또는 단독으로 사용시와 또한 약물을 사용하지 않았을 때, 이들이 모세혈관의 개존성과 아울러 미세수술후의 조직 생존율에 미칠 수 있는 효과를 보기 위하여 허혈상태의 토끼 이개를 미세수술로 접합한 후 모세혈관으로의 혈류를 측정하기 위하여 레이저 초음파 혈류측정기(Laser doppler flowmetry)를 이용하였으며 방사선 구슬들(Cobalt-57 with plastic material with average diameter 15 micron)을 주입한 결과 유로키나제 조합에서 통계적으로 유효한 성적을 얻었다. 광학현미경 소견은 유로키나제와 헤파린을 병용한 조합에서 모세혈관내 내피세포의 배열이 유지되어 있었으며 헤파린을 사용한 조합에서도 유사한 소견을 보였으나 약물을 사용하지 않은 조합에서는 국소적인 내피세포의 배열이 결핍되어 있었다. 전자현미경 소견에서 유로키나제와 헤파린을 병용한 조합에서 내피세포가 혈관내벽에 배열되어 있었고 또 불규칙한 세포질이 돌출되어 있었다.

  • PDF

Surgical Treatment of Complete Atrioventricular Septal Defect with Tetralogy of Fallot - Report of one case - (활로씨 4징증을 동반한 완전방실중격결손의 수술치험 -1례 보고-)

  • 이재훈;이광숙;박남희;최세영;박창권;유영선
    • Journal of Chest Surgery
    • /
    • v.35 no.6
    • /
    • pp.460-462
    • /
    • 2002
  • We experienced primary repair of complete atrioventricular septal defect with Teralogy of Fallot. The diagnosis was established preoperatively by echocardiography, cardiac catheterization and cardioangiography. Repair was accomplished using cardiopulmonary bypass. Two patch techinque were performed using Dacron patch for ventricular septal defect and pericardial patch for atrial septal defect. Infundibullectomy and right ventricular outflow tract reconstruction with the transannular pericardial patch were performed. The postoperative echocardiography showed mild mitral and tricuspid regurgitation, but there were no hemodynamic abnormalities.

A Study about Experimental Evaluation of an Ultrasonic Surgery Unit for Bone-cutting (골 절삭용 초음파 수술기의 실험적 평가에 관한 연구)

  • Sa, Min-Woo;Shim, Hae-Ri;Ko, Tae-Jo;Lee, Jong-Min;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In the dentistry field, an ultrasonic surgery unit is widely used in bone cutting and scaling to reduce operation time and minimize hemorrhage. The purpose of this study was to evaluate bone cutting and the effect of a specimen's temperature on the two-type ultrasonic surgery unit using a handpiece moving system(HMS). A HMS, which can cut the bone, was developed to perform the experimental procedure with precision of motion control. Bone specimens were prepared from a combination of epoxy-hardener and cortical bone of bovine leg. Through the bone-cutting experiment, the cutting depth was evaluated by not only scanning electron microscopy, but also Vernier calipers. Also, the temperature distribution was measured by a thermo-graphic camera. This study may be applied methodically in various experimental evaluations on a performance test by a HMS.

A Study on Temperature Changes during Bone Scaling and Cutting of Dental Ultrasonic Scaling/Surgery System (치과용 초음파 스케일러/수술기 통합 시스템의 스케일링 및 절삭 시 온도 변화에 관한 연구)

  • Sa, Min-Woo;Ko, Tae-Jo;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • While dental clinics still use the ultrasonic scaling/surgery tool for teeth scaling and cleaning the tool's use is expanding steadily to include treatment of damaged teeth and bone tissue. In this study, a handpiece moving system (HMS) was developed to evaluate bone scaling and cutting in the field of dentistry. The HMS, through a scaling test of bone using a scaler tip, it was able to identify surface damage. Additionally, a thermos-graphic camera was used to observe the temperature distribution that occurred during the bone scaling and cutting process. Consequently, we found that increasing the working load increased the amount of surface damage. Changes in temperature distribution occurred slowly and were maintained within safety bounds for 10 minutes. Going forward, we will compare the HMS performance on scaling and cutting with other devices.

Urethral Leiomyoma Complicated with Lower Urinary Tract Obstruction in a Dog (개에서 요도 평활근종에 의한 하부 비뇨기계 폐색 증례)

  • Hong, Kyung-Hwa;Kim, Ki-Sik;Lee, Hye-Yeon;Choi, Ji-Hye
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.181-185
    • /
    • 2012
  • An 11-year-old, intact female Shihtzu showing anuria was diagnosed as a urethral leiomyoma. The tumor occupied and obstructed the urethral lumen. In this report, the urethral tumor and secondary obstruction could be diagnosed via ultrasonography and contrast study such as excretory urography and voiding urethrography. Ultrasonography revealed a hypoechoic, demarcated urethral mass in proximal urethra. Contrast study confirmed the urethral obstruction and ruled out the expansion of the tumor into the urinary bladder. The clinical signs of the dog were completely resolved after removing the urethral mass and urethral anastomosis. Leiomyoma is a benign smooth muscle tumor, and rarely reported in lower urinary tract.

Development of Handpiece Moving System (HMS) for Cutting Performance Evaluation of Dental Ultrasonic Surgery Unit (치과용 초음파 수술기의 절삭성능 평가를 위한 핸드피스 이송 시스템 구축)

  • Sa, Min-Woo;Shim, Hae-Ri;Ko, Tae-Jo;Lee, Jong-Min;Kim, Jong Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.5
    • /
    • pp.377-383
    • /
    • 2016
  • Recently, research on bone fracture and osteoplasty using ultrasonic bone surgery unit has been ongoing in the fields of dentistry, plastic surgery, and otorhinolaryngology. However, detailed data evaluation with ultrasonic bone surgery unit has not been conducted to date. In this study, we developed handpiece moving system (HMS) for cutting performance evaluation. In the experimental setup of HMS, a handpiece was immobilized, and bone samples from cortical bone of bovine leg were prepared. Also, the experimental process was described in detail, and a basic experiment was carried out to evaluate the cutting performance. Future study is required on all experimental process conditions by HMS.