• Title/Summary/Keyword: 초음파 수술도

Search Result 476, Processing Time 0.027 seconds

Assessment of the Severity of Degenerative Aortic Stenosis: Three Case Reports (퇴행성 대동맥판 협착증의 중증도 평가: 증례보고 3례)

  • Kim, Sung-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.270-275
    • /
    • 2019
  • The incidence of degenerative valve disease also increasing with the increasing life expectancy of the elderly population. Rheumatic valve disease is decreasing gradually and the incidence of calcified degenerative aortic stenosis (AS) is growing. Echocardiography is a very important tool for evaluating the prognosis and treatment method as well as the time of operation and diagnosis of heart valve disease. When evaluating valvular heart disease, 2-dimensional echocardiography, which observes all heart valves in detail, should take precedence. Understanding the clinical findings of degenerative valve disease and performing precise echocardiography are extremely important. In addition, an assessment of the severity of aortic stenosis is necessary to determine the surgical indications. An assessment of the severity by echocardiography was explained with three cases of degenerative aortic stenosis. To perform echocardiography accurately, it is necessary to understand degenerative valve disease and its clinical findings accurately.

The Neonatal Follow up and Correlative Analysis of Fetal Hydronephrosis (산전 수신증의 생후 추적 관찰)

  • Yoon Ho-Young;Kim Ji-Hong;Lee Jae-Seung;Kim Pyung-Kil;Kim Myung-Joon
    • Childhood Kidney Diseases
    • /
    • v.2 no.1
    • /
    • pp.60-68
    • /
    • 1998
  • Purpose: To determine the various prenatal factors related to the prenatal hydronephrosis diagnosed on prenatal ultrasonography. We also attempted to correlate the prenatal and neonatal renal pelvic anteroposterior diameter with the outcome in infancy Methods: Between 1985 and 1997. We retrospectively reviewed 105 renal unit (75 patient) with fetal hydronphrosis persisting postnatally. Investigation consisted of renal ultrasonography, voiding cystourethrography, diurectic renogram, and DMSA scan. Results: The 75 patient assesed had the following underlying cause: UPJ(Ureteropelvic juction) obstruction(52%). multicystic dysplastic kidney(10%). UVJ (Ureterovesicai juction) obstruction (10%) and no underlying cause (25%). Of theses cases 36 cases (40 renal unit) underwent operation, while 28 cases (50 renal unit) resoled spontaneously. 12% of mild hydornephrosis deteriorated. whereas 50% of modrate hydrophrosis and 81% of severe hydronephrosis required surgical correction. Attempting to find the renal unit that were at risk for deterioration. our study showed that urinary tract infection group and calyceal blunting group had a predictive role. Conclusion: It is necessary to follow up after birth dilatation of caylx or urinary tract infection are present. Early operation is considered when prenatal pelvic AP diameter greater is than 22 mm and postnatal diameter greater than 17 mm. This may make it possible to prevent further progression of renal damage and prompt treatment of asymptomatic hydronephrosis before complications occur.

  • PDF

Usefuless of Ultrasonography Examination in Radial Nerve Palsy Associated with Humerus Fracture - Technical Report - (상완골 골절에 동반된 요골 신경 마비 환자에서 초음파 검사의 유용성 - 술기 보고 -)

  • Lee, Sang-Hyuk;Sung, Chang-Min;Park, Hyung-Bin
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • Primary radial nerve palsy occurs in association with approximately 10% of humerus shaft fractures. Secondary radial nerve palsy, which is iatrogenic, occurs in association with approximately 10% to 20% of humerus shaft fractures. Whether the radial nerve palsy is caused primarily by the fracture or secondarily by the surgery, it is necessary to determine whether the radial nerve is being disrupted or compressed by the surrounding structures. This evaluation will dictate whether to await natural recovery or to perform surgical exploration. The current authors report one case of primary radial nerve palsy, due to the humerus fracture, and one case of secondary radial nerve palsy, associated with the osteosynthesis procedure. In both patients, the radial nerve was assessed for anatomical integrity with ultrasonography. Nerve disruption was found in one patient, and a sural nerve graft was performed. Nerve adhesion was found in the other patient, and neurolysis was performed. In both cases, the clinical results were satisfactory. This report focuses on the usefulness of ultrasonography in radial nerve assessment in patients with radial nerve palsy.

  • PDF

Deep Learning in Thyroid Ultrasonography to Predict Tumor Recurrence in Thyroid Cancers (인공지능 딥러닝을 이용한 갑상선 초음파에서의 갑상선암의 재발 예측)

  • Jieun Kil;Kwang Gi Kim;Young Jae Kim;Hye Ryoung Koo;Jeong Seon Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1164-1174
    • /
    • 2020
  • Purpose To evaluate a deep learning model to predict recurrence of thyroid tumor using preoperative ultrasonography (US). Materials and Methods We included representative images from 229 US-based patients (male:female = 42:187; mean age, 49.6 years) who had been diagnosed with thyroid cancer on preoperative US and subsequently underwent thyroid surgery. After selecting each representative transverse or longitudinal US image, we created a data set from the resulting database of 898 images after augmentation. The Python 2.7.6 and Keras 2.1.5 framework for neural networks were used for deep learning with a convolutional neural network. We compared the clinical and histological features between patients with and without recurrence. The predictive performance of the deep learning model between groups was evaluated using receiver operating characteristic (ROC) analysis, and the area under the ROC curve served as a summary of the prognostic performance of the deep learning model to predict recurrent thyroid cancer. Results Tumor recurrence was noted in 49 (21.4%) among the 229 patients. Tumor size and multifocality varied significantly between the groups with and without recurrence (p < 0.05). The overall mean area under the curve (AUC) value of the deep learning model for prediction of recurrent thyroid cancer was 0.9 ± 0.06. The mean AUC value was 0.87 ± 0.03 in macrocarcinoma and 0.79 ± 0.16 in microcarcinoma. Conclusion A deep learning model for analysis of US images of thyroid cancer showed the possibility of predicting recurrence of thyroid cancer.

Success and failure of endodontic microsurgery (미세 치근단 수술의 성공과 실패)

  • Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.465-476
    • /
    • 2011
  • In current endodontic practice, introduction of operating microscope, ultrasonic instruments, and microinstruments has induced a big change in the field of surgical retreatment. In this study, we aimed to offer key steps of endodontic microsurgery procedure compared with traditional root-end surgery, and to evaluate factors influencing success and failure based on published articles. Endodontic microsurgery is a surgical procedure performed with the aid of a microscope, ultrasonic instruments and modern microsurgical instruments. The microscope provides magnification and illumination - essential for identifying minute details of the apical anatomy. Ultrasonic instruments facilitate the precise root-end preparation that is within the anatomical space of the canal. Modern endodontics can therefore be performed with precision and predictability, thus eliminating the disadvantages inherent in traditional periapical surgery such as large osteotomy, beveled apicoectomy, inaccurate root-end preparation and the inability to observe isthmus. Factors influencing the outcomes of endodontic microsurgery may be diverse, but standardization of procedures can minimize its range. Among patient and tooth-related factors, periodontal status and tooth position are known to be prognostic, but there are only few articles concerning this matter. High-evidence randomized clinical trials or prospective cohort studies are needed to confirm these findings.

Recent Perspectives on Oncoplastic Breast Surgery in Korea (우리나라의 종양성형학적 유방암 수술에 대한 최신 동향)

  • Kang, Taewoo
    • Journal of Life Science
    • /
    • v.30 no.6
    • /
    • pp.563-569
    • /
    • 2020
  • Oncoplastic surgery (OPS) combines oncologically safe tumor resection with aesthetically satisfying reconstruction of defects using established plastic surgery techniques. OPS is characterized by initial excision as extensive as is beneficial for oncological safety, and, once sufficient resection is complete, displacement or replacement techniques are selected based on remnant volume. The size of the lesion and the individual patient are important factors when considering the appropriate approach, and when pre-operative imaging, including MRI, is used to determine the technique, the complete removal of cancer cells by permanent pathology is essential. A frozen section is used during the operation to reduce the reoperation rate, but it is difficult to cover the entire margin surface theoretically and even harder in practice. A recent report about adequate margins has empowered OPS in its oncological safety. Considering the patients to whom each modality could be applied, basic breast volume is an important factor, and this is influenced by ethnic differences. In Europe or the US, for example, the average breast size is 36D (600 ㎤) and reduction mammoplasty is predominantly used. However, the average size of patients in our institution is 33A (300 ㎤), and so quite different approaches are selected in most cases. New techniques involving radiofrequency and fluorescence have been proposed as safe and easily accessible ways of reducing complications.

A Study on the Development of High-intensity focused Ultrasound Device for the Beauty Treatment Health Care (미용 치료 헬스케어를 위한 고강도 집속 초음파 장치 개발 연구)

  • Lee, Woo-Cheol;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.12
    • /
    • pp.1259-1264
    • /
    • 2016
  • Ultrasonic therapy has received great attention in the field of cosmetics related to the treatment of skin thickening because of its fast recovery and safety. In this study, an output circuit of a high intensity focused ultrasound system was developed for the treatment of beauty. To verify the applicability of the high intensity focused ultrasound system to the cosmetic treatment field, we measured and analyzed the 3D ultrasound intensity energy using a hydrophone. And high-intensity focused ultrasound devices were found to be useful for cosmetic treatment.

Usefulness of Ultrasonographic Diagnosis for Knot Impingement Syndrom: 3 Cases Report (매듭 충돌 징후에 대한 초음파 진단의 유용성: 증례보고 3례)

  • Chae, Seung Bum;Choi, Chang Hyuk;Kim, Min Su
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.70-75
    • /
    • 2013
  • We experienced three cases with chronic shoulder pain due to a knot impingement after arthroscopic rotator cuff tear repair and treated with arthroscopic revision surgery. Ultrasonography is commonly used for an imaging scan and an useful diagnostic tool to follow up after rotator cuff repair recently. We also could diagnose three cases with the knot impingement using ultrasonography obviously. And we report these cases with a review of current literature.

  • PDF

Endovenous 980-nm Diode Laser Treatment of Incompetent Great Saphenous Vein (정맥 내 980-nm 다이오드 레이저를 이용한 대복재정맥 역류의 치료)

  • Kim, Kun-Il;Jo, Tae-Jun;Lee, Jae-Woong;Hong, Ki-Woo;Lee, Won-Yong
    • Journal of Chest Surgery
    • /
    • v.40 no.2 s.271
    • /
    • pp.97-102
    • /
    • 2007
  • Background: Endovenous laser treatment has recently been introduced as a less invasive technique, with many good results reported, A 980-nm diode laser was used on the great saphenous vein (GSV) occlusions in patients with varicose veins, due to GSV reflux, and the therapeutic effects analyzed. Material and Method: Between September 2003 and February 2006, 238 patients (332 cases) with GSV reflux underwent endovenous laser treatment with a 980-nm diode laser. Operative procedures were simultaneous endovenous laser treatment and ambulatory phlebectomy. The preoperative clinical findings, postoperative complications and postoperative duplex US follow up results at 1 and 3 months were reviewed. Result: Postoperative complications were ecchymosis in almost cases, paresthesia 68 cases (20.5%) and skin burn in 3 cases (0.9%). Follow up duplex US revealed 26 and 10 cases at 1 and 3 months of GSV reflux or partial recanalization, with therapeutic success rates of 91.3 and 87.9%, respectively. Conclusion: The treatment of GSV occlusion with an endovenous laser is less invasive than traditional GSV stripping, but relatively high recanalization was experienced, possibly due to inadequate laser power, laser fiber pullback speed or an extremely dilated GSV. However, continuous attempts will be required to reduce the recanalization after the procedure, with accurate follow up using duplex US.