• Title/Summary/Keyword: 초음파 생검

Search Result 67, Processing Time 0.029 seconds

Fine Needle Aspiration Cytology vs. Core Needle Biopsy for Thyroid Nodules: A Prospective, Experimental Study Using Surgical Specimen (갑상선 결절에 대한 세침 흡인 세포 검사와 중심부 바늘 생검의 비교: 수술 검체를 기반으로 한 전향적, 실험적 비교 연구)

  • Hyuk Kwon;Jandee Lee;Soon Won Hong;Hyeong Ju Kwon;Jin Young Kwak;Jung Hyun Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.645-657
    • /
    • 2022
  • Purpose To evaluate and compare the diagnostic outcomes of ultrasonography (US)-guided fine needle aspiration (FNA) and core needle biopsy (CNB) performed on the same thyroid nodule using a surgical specimen for direct comparison. Materials and Methods We included 89 thyroid nodules from 88 patients from February 2015 to January 2016. The inclusion criterion was thyroid nodules measuring ≥ 20 mm (mean size: 40.0 ± 15.3 mm). Immediately after surgical resection, FNA and subsequent CNB were performed on the surgical specimen under US guidance. FNA and CNB cytopathologic results on the specimen were compared with the surgical diagnosis. Results Among the 89 nodules, 30 were malignant and 59 were benign. Significantly higher inconclusive rates were seen in FNA for malignant than benign nodules (80.0% vs. 39.0%, p < 0.001). For CNB, conclusive and inconclusive rates did not differ between benign and malignant nodules (p = 0.796). Higher inconclusive rates were seen for FNA among cancers regardless of US features, and in the subgroup of size ≥ 40 mm (62.5% vs. 22.9%, p = 0.028). Eleven cancers were diagnosed with CNB (36.7%, 11/30), while none was diagnosed using FNA. Conclusion In this experimental study using surgical specimens, CNB showed a potential to provide improved diagnostic sensitivity for thyroid cancer, especially when a conclusive diagnosis is limited with FNA.

Ultrasound-guided Core Needle Biopsy in Diagnosis of Soft Tissue Masses (연부조직 종물의 진단에서 초음파 유도하 중심부 침생검)

  • Kim, Jeung-Il;Youn, Myung-Soo;Cheon, Sang-Jin;Choi, Gyung-Un;Lee, Tae-Hong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.113-119
    • /
    • 2004
  • Purpose: To determine the utility of sonographically guided percutaneous core needle biopsy to diagnose musculoskeletal soft tissue masses. Methods: A prospective study was performed in 55 patients referred for image-guided needle biopsy of primary or recurrent soft tissue masses and bone lesion or suspected solitary metastasis with extraosseous masses. Tissue samples were obtained with a 14-gauge or 18-gauge cutting needle coupled to an automated biopsy device under local anesthesia and sonographic guidance. Statistical analysis was based on 49 biopsies confirmed by successful clinical treatment (11 cases) or surgical resection (38 cases). Results: An accurate diagnosis was obtained in 47 (97%) of 49 biopsies; sensitivity was 95%, and specificity was 100%. The method did not yield sufficient tissue to establish a diagnosis in 6 cases. Considering all 55 biopsies, high-quality specimens were obtained in 87%. There were no serious complications. Conclusions: Sonographically guided core needle biopsy is accurate and safe, in soft tissue masses and bone tumors with extraosseous masses in the appendicular skeleton. In such patients, the sonographically guided procedure is the most prompt and effective method for obtaining tissue samples.

  • PDF

Clinical Efficacy of the Ultrasonography in the Diagnosis of the Palpable Soft Tissue Masses (촉지되는 연부조직 종괴의 진단에서 초음파 검사의 유용성)

  • Park, Tae Soo;Kim, Hong Sik;Kim, Sungjun;Ryu, Jeong Ah
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.59-65
    • /
    • 2011
  • Purpose: To determine the clinical efficacy of the ultrasonography (US) for the diagnosis of the soft tissue masses comparing to the clinical diagnosis through the physical examination. Materials and Methods: 83 consecutive patients with palpable soft tissue masses were presented retrospectively. On the basis of the pathological diagnosis after the operation, the diagnostic accuracies were evaluated the cases diagnosed by history taking and physical examination, and the cases diagnosed by US before the operation. Results: The diagnostic accuracy of the cases using US was higher(86.7%) than that of the cases using physical examination and history taking. The accuracy of US of the epidermal inclusion cyst was 71.4%, ganglion cyst 85.7%, lipoma 88.6%, respectively. Accurate diagnosis were made 54 cases with 65.1% sensitivity in the cases diagnosed by history taking and physical examination. In this case, its accuracy of the ganglion cyst was 56.0%, and the lipoma was 67.9%. Conclusion: US is a useful diagnostic tool for the diagnosis of the palpable soft tissue masses before the operation.

  • PDF

Observation of Changes in Indoor Formaldehyde(HCHO) Concentration during Ultrasound Guided Biopsy (초음파 조직생검 시 실내의 포름알데히드(HCHO) 농도 변화 관찰)

  • Lee, Hoon-Jeong;Kang, Sung-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1057-1064
    • /
    • 2021
  • This study was conducted by simulating the same environmental conditions as the actual biopsy to observe the change in formaldehyde(HCHO) concentration in the indoor air during ultrasound guided biopsy. Changes in HCHO concentration in the room were measured by successively performing five steps: sealing the ultrasound room, ventilation, opening formalin containers, sealing formalin containers, and re-ventilating. Trends of measured HCHO concentration changes were visualized using graphs. As a result of analyzing the consistency of the concentration change values measured three times using the intra-class correlation coefficient, it was found to be 0.989, which was statistically significant(p<0.05). Based on the results of this study, we hope that medical workers working in the HCHO exposure environment of the field of radiology part will improve their awareness of the necessity of exposure management at work, and actively discuss the establishment of an environment for exposure control and preparation of countermeasures.

Musculoskeletal Ultrasound Intervention: Principles & Cautions (초음파를 이용한 침습적 치료: 원칙과 주의점)

  • Oh, Gun-Myung;Lee, Kyung Jae;Min, Byung-Woo;Kim, Dong-Wan
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.38-44
    • /
    • 2013
  • The ultrasound can be used primarily to guide exact needle placement for aspirations of fluids, injections of steroid, and biopsies in musculoskeletal field. Recently, ultrasound-guided intervention is widely used because of several advantages such as real-time performance, relatively inexpensiveness, and getting multiple images without additional radiations. However, the modality is operator dependent and requires detailed knowledge of the relevant anatomy and there have been also reported serious complications related to the procedure. So, authors will discuss about the basic techniques, principles and cautions for the use of ultrasound-guided intervention in musculoskeletal field.

  • PDF

Ten-year Clinical Study of Chorionic Villus Sampling (융모막 융모생검 511례에 대한 임상적 연구: 10년(2000-2010년)간의 경험)

  • Kim, Soo-Hyun;Shim, Sung-Han;Baek, Jong-Woo;Cha, Dong-Hyun
    • Journal of Genetic Medicine
    • /
    • v.8 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • Purpose: We evaluated indications for chorionic villus sampling (CVS), the positive predictive value of CVS for fetal chromosomal abnormalities, and the fetal loss rate after CVS at CHA Medical Center. Materials and Methods: We reviewed the medical records of 511 cases of CVS performed between 67 and 120 days of gestation for prenatal cytogenetic diagnosis from April 2000 to April 2010. Fetal karyotypes were obtained by direct and indirect culture methods. Results: The most common indications for CVS were abnormal ultrasonic findings including increased nuchal translucency (294/635, 46.3%). The positive predictive value of abnormal karyotyping according to indication for CVS was highest in cases with abnormal parental karyotypes (14/21, 66.7%). Mosaicism revealed by CVS comprised 3.1% of the sample (16/509). Amniocentesis revealed two cases of true mosaicism and 11 cases of confined placental mosaicism. The fetal loss rate within 4 weeks of the procedure was 1.2% (6/511). Conclusion: If CVS is performed by an expert clinician, it is a feasible and reliable procedure for prenatal genetic diagnosis. When CVS indicates mosaicism, the finding should be confirmed by amniocentesis to distinguish true mosaicism from confined placental mosaicism.

The Role of Ultrasound Guided Core Needle Biopsy in Thyroid Nodule (갑상선 결절에서 초음파 유도하 중심생검의 역할)

  • Ryu, Yoon-Jong;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • Fine needle aspiration cytology(FNAC) holds a main role in assessing thyroid nodules. But nonnegligible rate of thyroid cytology is reported as uncertain, indeterminate or inadequate for diagnosis. Recently, the microhistologic evaluation by core needle biopsy(CNB) under ultrasound sonographical guidance has been reported to show high accuracy for the diagnose of thyroid nodules. Aim of this review was to furnish the state of the art of this topic by summarizing previous published data about indication, diagnostic performance, and complication of CNB in thyroid lesions compared with FNAC

  • PDF

A Study on the Reflectivity according to the Material of Biopsy Gun Needle Used in Ultrasound Biopsy (초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구)

  • Hoon Kim;Cheong-Hwan Lim
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.97-105
    • /
    • 2024
  • The examination needle used in ultrasound biopsy is a medical device used to determine whether there is an abnormality in the tissue. Typically, stainless steel is the standard material used for such needles; however, this study wanted to identify a material that could better enhance sound compared to traditional stainless steel. In this study, six types of needle materials available with the biopsy gun were inserted into pork and ultrasound images according to the curved probe and linear probe were evaluated using ultrasound equipment. The findings revealed significant improvements in ultrasound acoustic enhancement with alternative materials compared to stainless steel (p<0.05). The results regarding the depth of each ultrasound image using the curved probe showed that tungsten and brass had high sound enhancement(p<0.05), while with the linear probe, sound enhancement was high in brass, pla, aluminum, and copper(p<0.05). Due to these results, the previously used stainless needle showed lower ultrasound acoustic enhancement than the five types of materials being compared. Consequently, the outcomes of this study provide valuable insights for the development of new needle technologies aimed at minimizing patient risks and improving diagnostic accuracy.

Herpes Simplex Mastitis in an Adolescent Woman: Clinical and Ultrasound Features (사춘기 여성의 단순 포진 유선염: 임상 및 초음파 영상 소견)

  • Seung Kwan Kim;Bo Kyoung Seo;Hwa Eun Oh
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.714-718
    • /
    • 2020
  • Herpetic mastitis is extremely rare, and its imaging findings remain unclear. We report a case of herpes simplex mastitis in an adolescent woman and describe the clinical and ultrasound features. The patient showed unilateral nipple and areolar skin thickening and axillary lymphadenopathy on B-mode ultrasonography. Doppler ultrasonography revealed multiple linear and branching blood flows in the areolar area. The lesion was verified as herpes simplex mastitis via a skin biopsy. This report shows that the radiologic features of herpes simplex mastitis may be similar to those of Paget's disease because of localized nipple and areolar skin thickening and increased vascularity.

The Study for Results of Complex Cystic Breast Masses by Biopsy on Ultrasound (초음파상 복합성 낭성 유방 종괴의 조직 검사 결과에 관한 연구)

  • Kang, Hye-Kyoung;Dong, Kyung-Rae
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.129-134
    • /
    • 2008
  • Purpose: We examined the roles of Ultrasonography conductors by analyzing the results of tissue biopsy of complex cystic masse under the guidance of breast US. Objects and methods: This study was performed to a group of 178 who showed breast US indicating complex cystic masses among 342 patients who were definitely diagnosed by tissue biopsies and operations in our hospital from June 30th, 2003 to June 30th, 2007. The evaluation of tissues around, calcification, the distribution state of blood flow were excluded from the analysis subjects and logic 200 made by GE corporation and gun for core biopsy(Kimal corp., K7/MBD23) were used in this study. Results: The biopsy results of 178 subjects showed FCC (fibrocystic change)(n=56 : 31.4%), Fibrosis (n=41 : 23.0%), Fibroadenoma (n=20 : 11.2%), Epithelial hyperplasia (n=17 : 9.6%), Carcinoma (n=15 : 8.4%), Fibroadipose (n=8 : 4.5%), Sclerosing adenosis (n=7 : 3.9%), Duct ectasia (n=5 : 2.8%), Papiloma (n=5 : 2.8%), and Fat necrosis (n=1 : 0.6%), Hemangioma (n=1 : 0.6%), Abscess (n=1 : 0.6%), Dystrophic calcification(n=1 : 0.6%). Conclusion: The US showed that the results of the tissue biopsy of complex cystic masses were mostly carcinoma(8.4%). Most of them were benign and only 9.6% of epithelial hyperplasia which has high progression rate into malignant tumors epidemically showed malignancy. Most of them were included in the spectrum of fibrous cystic nodule. Even though these results are confirmed, further studies are required. As a result, a nodule which is not certified by US should be right to take the tissue biopsy, but if it's difficult due to patients or another reasons, re-check tests in three months are required. And systemic ultrasonography evaluation should be well recognized to conduct more careful and specific tests.

  • PDF