• Title/Summary/Keyword: 초음파 겔

Search Result 13, Processing Time 0.022 seconds

Analyzing Image Quality and Disinfection Effectiveness of Alcohol Gel Application in Ultrasound Scans (초음파 스캔에서 알코올 겔 적용 시 화질과 소독효과 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.365-372
    • /
    • 2024
  • To analyze the image quality and disinfection effectiveness of alcohol gel application in ultrasound scans, we varied the application of alcohol gels with different alcohol content from ultrasound gels. The image quality analysis compared the Dead zone, axial and lateral resolution, sensitivity, and gray scale changes using the ATS-539 phantom, while the disinfection effectiveness analysis was performed by swabbing the three cover faces of convex probe used in clinical practice, collecting specimens and enrichment culture them for 24 hours before identification with Gram stain. image quality analysis showed that all items, regardless of the alcohol content, produced images that were not different from the ultrasonic gel application images, and pathogens such as staphylococcus aureus, streptococcus, and enterococcus were detected on all probes, and all were extinction by the application of alcohol gel. The application of alcohol gel during ultrasound examination was meaningful in terms of image quality maintenance and disinfection effect, and if the results of this study are further studied and commercialized, the application of alcohol gel as an alternative to ultrasound gel will be very useful in clinical examinations because it can consider not only image quality but also infection prevention.

Phonophoretic Transdermal Drug Delivery of Triamcinolone acetonide gel (트리암시놀론 겔의 음파영동 경피약물흡수)

  • Kim Tae-Youl;Kim Gye Yeop
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.219-233
    • /
    • 2002
  • 스테로이드성 소염진통제인 트리암시놀론 겔의 피부투과도를 향상시키기 위하여 초음파를 조사하여 약물의 투과도에 미치는 영향을 비교하였다. 트리암시놀론을 함유한 수용성 겔을 제조하여 물리화학적 시험을 실시하였으며 carbopol을 기제로한 겔이 우수한 제제학적 특성을 보였다. 초음파 조사가 약물의 투과도에 미치는 영향을 알아보기 위하여 hairless mouse의 적출 피부에 대한 in vitro 흡수 실험을 실시하였다. 트리암시놀론 겔 음파영동군이 트리암시놀론겔 단독 처치군에 비하여 투과도가 유의적으로 향상되었다. 특히 주파수가 1MHz인 지속초음파를 고 강도로 적용시 피부투과도의 향상이 더욱 두드러졌다. 따라서 트리암시놀론 겔 도포 후 초음파를 이용한 음파영동 경피흡수가 단독의 겔 처치보다 피부투과에 유용할 것으로 사료된다.

  • PDF

Preoperative Evaluation of Lower Rectal Cancer by Pelvic MR with and without Gel Filling (하부직장암 환자에서 초음파겔 삽입 전후의 골반 자기공명영상의 비교)

  • Kim, Dae Jung;Kim, Joo Hee;Lim, Joon Seok;Chung, Jae-Joon;Yu, Jeong-Sik;Kim, Myeong-Jin;Kim, Ki Whang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.323-331
    • /
    • 2014
  • Purpose : To assess the usefulness of rectal filling using ultrasonographic gel in patients with lower rectal cancer. Materials and Methods: Twenty five patients with lower rectal cancer were enrolled. High resolution pelvic MR was performed twice before and after gel filling. Independently and retrospectively, two radiologists reviewed each set of MR images using five-grade scales for sphincter involvement, CRM (circumferential resection margin) involvement and depiction of the tumor. Same two radiologists retrospectively performed consensus review of each set of MR images for tumor distance from the anal verge and T&N staging. Results: Tumor depiction scores from MR with gel filling were significantly higher than those of MR without distention (p<0.001). Compared to MR without distension, MR with gel filling had no significant differences in prediction of CRM or sphincter involvement (p>0.05). Distance from the anal verge was significantly different between MR with gel filling and rigid endoscopy ($6.8{\pm}1.6cm$ vs. $5.8{\pm}1.6cm$, p=0.001). There were no significant differences between pathological staging and MR staging with or without gel filling. Conclusion: MR with gel filling improved tumor depiction. And also MR with gel filling revealed same ability for the predictions of CRM or sphincter invasion in patients with lower rectal cancer, comparing with MR without gel filling.

Enhanced Transdermal Permeation Effects of Lidocaine Gel by Low Frequency Ultrasound (저주파수 초음파를 이용한 Lidocaine Gel의 피부투과 촉진 효과)

  • Jung, Dae-In;Lee, Jung-Woo;Ahn, Hyo-Cho;Yang, Jae-Heon;Kim, Tae-Youl;Cho, Seong-Wan;Kim, Young-Il
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.217-221
    • /
    • 2008
  • To investigate the enhancing effects in transdermal permeation of drug using newly designed ultrasound apparatus of 500 kHz, the transdermal permeation studies through the hairless mouse skin were conducted with lidocaine. The ultrasound apparatus of 500 kHz frequency and transducer were newly developed. The drug permeation studies were performed according to the ultrasound frequencies such as 1 MHz and 500 kHz at $1W/cm^2$ in intensity in continuous mode or pulsed mode, respectively. The results on transdermal permeation of lidocaine according to ultrasound intensity showed that the drug permeation increased as the intensity was higher.

The Characteristics of Vanadium based Composite Cathode for Lithium Secondary Battery (리튬이차전지용 바나듐계 복합양극의 특성)

  • Kim Jong-Jin;Son Won-Keun;Kim Jae-Yong;Park Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.2
    • /
    • pp.61-65
    • /
    • 1999
  • A new treatment of $LiV_3O_8$ has been proposed for improving its electrochemical behavior as a cathode material for secondary lithium batteries. Lithium trivanadate, $LiV_3O_8$, can be prepared in a finely dispersed form by dehydration of aqueous lithium trivanadate gels. The ultrasonic treatment method for Liv30s has been examined in comparison with $LiV_3O_8$ prepared by solutionmethod. The ultrasonically treated products in water were characterized by XRD (X-ray diffractometry), TGA (thermogravimetric analysis) and SEM (scanning electron microscopy). These measurements showed that the ultrasonic treatment process of aqueous $LiV_3O_8$ caused a decrease in crytallinity and considerable increased in specific surface area and interlayer spacing. The product, ultrasonically treated in water for 2 h, showed a high initial discharge capacity and was charge-discharge cycled without large capacity loss. The ultrasonic treated Liv30s can improve not only the specific capacity, but also the cycling behavior

NaBH4 Hydrolysis Reaction Using Co-P-B Catalyst Supported on FeCrAlloy (Co-P-B/FeCrAlloy 촉매를 이용한 NaBH4 가수분해 반응)

  • Hwang, Byungchan;Jo, Ara;Sin, Sukjae;Choi, Daeki;Nam, Sukwoo;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.35-41
    • /
    • 2013
  • Properties of $NaBH_4$ hydrolysis reaction using Co-P-B/FeCrAlloy catalyst and the catalyst durability were studied. Co-P-B/FeCrAlloy catalyst showed low activation energy such as 25.2 kJ/mol in 5 wt% $NaBH_4$ solution, which was similar that of noble metal catalyst. The activation energy increased as the $NaBH_4$ concentration increased. Formation of gel at high concentration of $NaBH_4$ seriously affected hydrogen evolution rate and the catalyst durability. The catalyst loss decreased as reaction temperature increased due to lower gel formation when the concentration of $NaBH_4$ was over 20 wt%. Considering hydrogen generation rate and durability of catalyst, the catalyst supported with FeCrAlloy heat-treated at $1,000^{\circ}C$ without ultra vibration during dipping and calcination after catalyst dipping was best catalyst. To use catalyst more than three times in 25 wt% $NaBH_4$ solution, it should be reacted at higher temperature than $60^{\circ}C$.

Transdermal Delivery of Triamcinolone acetonide Gel by Ultrasound (초음파 조사에 의한 트리암시놀론 아세토니드 겔의 피부투과)

  • Song, Kyung-Suk;Kim, Young-Il;Yang, Jae-Heon
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.2
    • /
    • pp.87-93
    • /
    • 2002
  • This study is to enhance drug penetration via skin and investigate anti-inflammation effect following adoption of ultrasound. For this goal gel containing triamcinolone was prepared and the skin penetration rate and the change effects of blood plasma ingredients and serum enzyme were investigated. Using Franz type diffusion cell and the skin of hairless mouse, the permeation enhancing effect of ultrasound was tested. After the injury by direct trauma, the blood test was performed by measuring WBC, lymphocyte, and neutrophyl, and by analyzing CPK and LDH. The ultrasound transducer whose technical specification is geometric area(GA) $1.4\;cm^2$, effective radiation area(ERA) $0.8\;cm^2$, and beam non-uniformity ratio(BNR) 6.0 max was used. The influence of frequency having an effect on skin permeation rate was higher in the case of using 1MHz and continuous treatment. The temperature of receptor phase was not influenced in skin permeation by phonophoresis. Skin permeation increase attended by intensity of ultrasound, the permeation of triamcinolone was accelerated at $2.5\;w/cm^2\;than\;1.0\;w/cm^2$. Following muscle injury phonophoretic group the number of WBC, neutrophil and lympholyte were decreased significantly as compared with both control group and ultrasound group. The result of variation of serum CPK and LDH activity conformed to the phonophoretic effect as same pattern with the variation of WBC, neutrophil and lymphocyte.

Development of the Calcium Alginate Bead Immobilized with $TiOSO_4$ for the Efficient Removal of Phosphorous (Phosphorous의 효율적인 제거를 위한 $TiOSO_4$ 고정화 Calcium Alginate Bead의 제조기법에 관한 연구)

  • Choi, Jae-Woo;Lee, Seung-Yeon;Chung, Seung-Gun;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.162-166
    • /
    • 2011
  • Phosphorous contaminated in the effluent from sewage treatment plants can cause the eutrophication in surface water bodies. In this study, a powder of titanium oxysulfate-sulfuric acid made of ion-exchange materials was immobilized in an alginate gel and this material was examined to evaluate its phosphorous removal efficiency. Equilibrium and kinetic studies were carried out to quantify the adsorption capacity and time dependent removal rate of phosphorous. Adsorption isotherms and kinetic parameters were obtained for the entrapped titanium beads with three different methods. Equilibrium data were analyzed using Langmuir adsorption isotherm model and found to be well fitted to the model. The maximum adsorption capacity for phosphorous by the titanium bead synthesized with the solution method was 92.26 mg/g. Kinetic data followed a pseudo-second-order kinetic model. Due to the low production cost and high adsorption capacity, the titanium bead synthesized by the solution method has a potential to be utilized for the cost-effective removal of phosphorous from wastewater.

Synthesis and Characterization of Zeolite 4A on Activated Carbon Supports (활성탄 지지체상에서 제올라이트 4A 합성 및 특성)

  • Park, Jeong-Hwan;Suh, Jeong-Kwon;Jeong, Soon-Yong;Lee, Jung-Min;Doh, Myung-Ki
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.204-210
    • /
    • 1997
  • Zeolite 4A-impregnated complex molecular sieve was prepared by hydrothermal reaction after aluminosilicate gel was penetrated into the pore of activated carbon granule. The crystals of zeolite 4A mainly were formed in the macropore of activated carbon, and their average diameter is $0.8{\mu}m$. The pore volume of activated carbon granule is $0.67m{\ell}/g$, and the pore volume of the sample including 21.6wt% of zeolite 4A crystal is $0.41m{\ell}/g$ decreasing the pore volume by 40% due to the crystallization of zeolite 4A crystals on the internal surface of activated carbon. The calcium ion exchange capacity of zeolite 4A-impregnated sample is 320mg $CaCO_3/g$ zeolite, and this value is almost the same as that of zeolite 4A powder. The crystal of zeolite 4A was not separated from the support of activated carbon granule in the course of ultrasonic dispersion. The adsorption isotherm of water on zeolite 4A-impregnated sample shows the intermediate shape between types, I and III. In addition, zeolite 4A-impregnated sample shows the hydrophilic and hydrophobic properties simultaneously.

  • PDF