• Title/Summary/Keyword: 초음파접합

Search Result 185, Processing Time 0.028 seconds

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF

Assessment of Fatigue Damage of Adhesively Bonded Composite -Metal Joints by Acousto-Ultrasonics and Acoustic Emission (음향초음파와 음향방출에 의한 복합재료-금속 접착접합부의 피로손상 평가)

  • Kwon, Oh-Yang;Lee, Kyung-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.425-433
    • /
    • 2001
  • A correlation between fatigue damage and acousto-ultrasonic (AU) parameters has been obtained from signals acquired during fatigue loading of the single-lap joints of a carbon-fiber reinforced plastic (CFRP) laminates and A16061 plate. The correlation showed an analogy to those representing the stiffness reduction $(E/E_0)$ of polymer matrix composites by the accumulation of fatigue damage. This has been attributed to the transmission characteristics of acoustic wave energy through bonded joints with delamination-type defects and their influence on the change of spectral content of AU signals. Another correlation between fatigue cycles and the spectral magnitude of acoustic emission (AE) signals has also been found during the final stage of fatigue loading. Both AU and AE can be applied almost in real-time to monitor the evolution of damage during fatigue loading.

  • PDF

Fundamentals of Ultrasonic Welding (초음파 용접의 기초)

  • ;Jeong, H. S.
    • Journal of Welding and Joining
    • /
    • v.15 no.6
    • /
    • pp.24-31
    • /
    • 1997
  • 2매의 금속을 맞대어 그 한 쪽에 접촉면과 평행하게 고주파진동을 가하면 단 시간에 접합된다. 이공정을 초음파 용접이라고 하며 그 물리적인 본질은 아직 불분명 하지만, 첫째로는 강한 마찰에 의해 금속 자유면의 산화물층이 제거되기 때문이라는 점과 둘째로는 마찰에 의해 금속 표면이 강하게 가열되어 이에 따른 연화에 의해 접합 이 된다고 하는 점이다. 그러나 이와 같이 가열된다고 하더라도 가열은 표면부에만 국한되고 다른 부분은 가열되지 않는다. 따라서 초음파용접은 냉간접합이라고도 한다. 또 가압력과 진동에 의한 힘이 동시에 작용하기 때문에 용접할 면을 미리 청정하게 할 필요는 없고 용접전의 단계에서 자연적으로 청정화가 이루어진다고 하는 사실이 간접 적으로 증명되고 있다. 초음파 용접(Ultrasonic welding)의 특징을 요약하면 고상용접 의 일종으로서 용접중에 국부적으로 고주파 진동에너지와 압력을 가하여 용접하는 방법이다. 이 때 모재를 용융시키지 않고 건전한 야금학적 결합부가 얻어진다는 데에 큰 특징이 있다. 또한 초음파용접은 다른 용접법에 비해 경제성이 매우 높고, 초음파 용접에 필요한 출력이 전기아크 용접에 필요한 출력의 5 - 10%로 충분한 경우가 많다. 초음파 용접은 통상의 방법으로는 용접하기 어려운 동종 금속이나 이종 금속의 용접에 널리 사용된다. 이 용접법은 반도체, 미세회로, 전기 접점의 형성에 대한 생산기술 로서 사용되고 있는데 소형 모터, 알루미늄 박의 가공, 알루미늄 합금의 조립 등에 이용되고 있다. 한편 최근에는 자동차, 우주항공산업 분야의 구조제 용접용으로도 채용되고 있다.출함이 바람직하다.분비되는 배설-분비 항원의 자극과 깊은 관계가 있음을 알 수 있었다.넌트 명세서를 대한 XML DTD(Document Type Definition)를 정의하고, HTML 기반 검색 방법과 XML 기반 검색 방법에 대한 컴포넌트 검색 성능을 비교한다.따라 NO 생산 및 세포독성이 증가하였고. NO 생산을 저하시키는 약제들은 활성화된 복강 대식세포 및 RAW264.7 세포에 의한 질편모충에 대한 세포독성을 현저히 감소시키는 것으로 보아 NO는 질편모충에 대한 대식세포의 숙주 방어기전에서 중요한 역할을 감당할 것으로 생각된다.nction index) 와 최대개구시 동통의 정도는 시술전과 시술 4주후간에 유의한 차이가 관찰되었다.피부온도는 검사자간에는 특정부위에 따라 다소 차이가 있을 수 있으나 일반적으로 높은 재현성을 보여줌으로서 향후 교근 및 측두근의 임상연구 평가에 피부온도조사는 도움이 되리라 사료된다. lactobacilli의 양은 peroxidase system을 함유하거나(p < 0.01) 함유하지 않은(p < 0.05) 치약을 사용한 군 모두에서 양치전에 비해 유의성있게 감소하였다. 6. 양치후 30분에 채취한 구강건조증 환자의 자극성 전타액내 S. mutans 양은 peroxida system을 함유한 세치제를 사용한 군에서 대조군에 비해 유의성있게 낮았다(p < 0.05). 7. 양치후 30분에 채취한 구강건조증 환자의 자극성 전타액내 lactobacilli양은 peroxidase system을 함유한 세치제를 사용한 군에서 대조군에 비해 상대적으로 낮게 나타났으나(p = 0.067)

  • PDF

Automatic Identification of the Lumen Border in Intravascular Ultrasound Images (혈관 내 초음파 영상에서 내강 경계면 자동 분할)

  • Park, Jun-Oh;Ko, Byoung-Chul;Park, Hee-Jun;Nam, Jae-Yeal
    • The KIPS Transactions:PartB
    • /
    • v.19B no.3
    • /
    • pp.201-208
    • /
    • 2012
  • Accurately segmenting lumen border in intravascular ultrasound images (IVUS) is very important to study vascular wall architecture for diagnosis of the cardiovascular diseases. After each of IVUS image is transformed to a polar coordinated image, initial points are detected using wavelet transform. Then, lumen border is initialized as the set of important points using non parametric probability density function and smoothing function by removing outlier initial points occurred by noises and artifacts. Finally, polynomial curve fitting is applied to obtain real lumen border using filtered important points. The evaluation of proposed method was performed with related method and the proposed method produced accurate lumen contour detection when compared to another method in most types of IVUS images.

A Study on Cooling of Piezoelectric Element of Multifunction Equipment for Vacuum Exhaust and Ultrasonic Joining (진공 배기 및 초음파 접합 복합기 진동자 냉각에 관한 연구)

  • Park, Sang-Jun;Lee, Young-Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1511-1517
    • /
    • 2012
  • Vacuum chamber or vacuum tube for the exhaust process of vacuum glazing is presently used, where excessive time and expenses are required to make the whole vacuum chamber or tube vacuum. To solve this problem, multifunction equipment for vacuum exhaust and ultrasonic joining at atmospheric pressure has been developed, in which a piezoelectric vibrator experiences excessive temperature rise resulting in optimizing the cooling of the equipment. Therefore, in this study, cooling effects of natural convection and forced convection methods were identified by numerical analysis and experiments, and cooling performance of the multifunction equipment was optimized.

Nondestructive Evaluation of Adhesive Bonding Quality by Measurements of Peak Amplitude of Simulated Stress Wave (모의 음향 방출 신호의 Peak Amplitude측정을 통한 복합 재료 접합부의 비파괴평가)

  • Son, Y.H.;Lee, J.O.;Lee, S.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.357-363
    • /
    • 1995
  • Disbond size of adhesively bonded single lap and double lap joints CFRP composite specimens has been evaluated using acousto-ultrasonic(AU) technique. Frequency spectra for all specimens were obtained by measuring peak amplitude of the stress wave propagated through the bond-lines. By analyzing these frequency spectra, peak amplitude was found to be proportional to fractional bonding area and to be maxima at the fundamental and the third order higher harmonic frequencies of specimen thickness mode. The disbond size can be evaluated quantitatively and this technique can be applied to real structures if the reference specimens are prepared in advancve.

  • PDF

Theoretical investigation of vibrational characteristics of a multi-layered piezoelectric element for ultrasonic transducers (초음파 탐촉자용 다층 압전접합체의 진동특성에 관한 이론적 해석)

  • Jang Hwan Soo;Roh Yongrae
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.383-386
    • /
    • 1999
  • 본 연구에서는 공중용 초음파 센서에 많이 사용되고 있는 원판형 압전소자, 정합층, 그리고 후면충, 세 부분으로 이루어진 다층 접합체의 진동 특성을 기계적 진동 방정식을 이용하여 이론적으로 해석하였으며, 해석결과의 타당성을 유한요소 해석방법을 사용하여 검증하였다. 본 연구의 해석 방법은 다층 판, 특히 압전세라믹과 정합층으로 이루어진 2층과 후면층이 추가된 3층에 대한 진동 방정식에 적절한 경계 조건 및 수렴조건을 적용하여 고유진동 주파수를 유도하였다. 그리고 이를 이용하여 초음파 탐측자 개발 시 널리 사용되고 있는 설계변수 즉, 각 층의 반경, 두께, 밀도, 그리고 영률의 변화에 대한 공진주파수의 변화 경향을 분석하였다. 공진주파수 변화 경향에 대한 이 해석 방법의 타당성을 널리 사용되고 있는 유한 요소해석법을 사용하여 검증한 결과, 두 해석결과는 좋은 일치를 보였다. 그러므로 본 연구의 결과는 종래의 등가회로나 유한요소 해석법에 비해 더 간편하고, 더 정확한 해석결과를 제공할 수 있는 해석도구로써 이용될 수 있을 것이다.

  • PDF

A Development of an Intelligent Ultrasonic Testing System for Nondestructive Testing of Weldments (용접부 비파괴검사를 위한 지능형 초음파 탐상시스템 개발)

  • Song, Sung-Jin;Cho, Hyun;Kim, Chang-Hwan;Jung, Hee-Jun;Lee, Jung-Gi
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.106-109
    • /
    • 2003
  • 지능형 초음파 탐상 시스템은 재래식 초음파 탐상시험에서 주된 논란의 대상이 되는 검사의 객관성과 신뢰성, 그리고 일반화된 검사자료의 데이터베이스화 문제를 해결할 수 있는 해법으로 제시 되었다. 또한 이 시스템은 검사의 자동화(혹은 간이자동화)를 통해 검사자에 의해 수작업으로 작성되던 피검체 및 결함관련 정보를 자동으로 계산하고 데이터베이스화함으로써, 열악한 검사환경에서도 최선의 능률을 제공할 수 있는 기반을 제공한다. 본 논문에서는 지능형 시스템의 개발을 위해 필요한 요소기술과 개발된 시스템의 전반에 관하여 논한다.

  • PDF

Ultrasonic Scatter and Compensation of Interfacial Crack due to Thickness Variation of Dissimilar Bonded Components (이종 접합부재의 두께 변화에 따른 계면균열의 초음파 산란 보정)

  • Park, Sung-Il;Chung, Nam-Yong;Jin, Yoon-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.25-30
    • /
    • 2004
  • In this paper, the compensation of interfacial scatter due to adhesive layer and adherend thickness ratio variation was applied to improve measuring precision by calculating ultrasonic attenuation coefficient in the Al/Epoxy dissimilar bonded components. The optimum condition of theoretical value and experimental measuring accuracy by the ultrasonic method in the Al/Epoxy dissimilar bonded components have been investigated. From the experimental results, we proposed a measurement method of the interfacial crack lengths by the ultrasonic attenuation coefficient and discussed it.

  • PDF

Evaluation of Adhesive Properties in Polymeric Thin Film by Ultrasonic Atomic Force Microscopy (UAFM을 이용한 폴리머 박막의 접합 특성 평가)

  • Kwak, Dong-Ryul;Park, Tae-Sung;Park, Ik-Keun;Miyasaka, Chiaki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.142-148
    • /
    • 2012
  • This study presents the assessment results of adhesive properties on the interface between a silicon wafer and nano-scale polymer thin film pattern through UAFM images by using the contact resonance frequency of the cantilever. For the experiment, we varied surface treatment processes for the silicon wafer and fabricated a 300nm polymer thin film pattern through lithography. Images from the optical microscope were used to compare the produced test specimens for adhesive condition and the critical load value from the nano scratch test was used to verify the adhesive condition of the nano pattern. Each test specimen resulted in a $1{\mu}m{\times}1{\mu}m$ surface image and subsurface adhesive image. Adhesive condition was evaluated by image contrast differences on the interface according to the changing amplitudes and phases of contact resonance frequency.