• Title/Summary/Keyword: 초음파력

Search Result 229, Processing Time 0.032 seconds

Analysis of Diagnostic Performance of CT and EUS for Clinical TN Staging of Gastric Cancer (위암의 임상적 병기 설정을 위한 전산화단층촬영 및 초음파 내시경의 진단력 평가)

  • Shin, Ru-Mi;Lee, Ju-Hee;Lee, Moon-Soo;Park, Do-Joong;Kim, Hyung-Ho;Yang, Han-Kwang;Lee, Kuhn-Uk
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.177-185
    • /
    • 2009
  • Purpose: Preoperative clinical staging of gastric cancer is very important for determining the treatment plans and predicting the prognosis. The previous reports regarding the accuracy of computed tomography or endoscopic ultrasound for the preoperative staging of gastric cancer have shown various outcomes. We analyzed the diagnostic performance of CT and EUS, which are important staging tools for the staging of TN gastric cancer. Materials and Methods: We retrospectively analyzed 1,174 patients who underwent gastrectomy for gastric cancer at Seoul National University Bundang Hostpital from May, 2003 to December, 2007. We derived the Kappa value to examine the agreement of the preoperative staging obtained from CT and EUS with the pathological staging. Results: The mean age of the 1,174 patients was $59.31{\pm}11.98$ years. Six hundred thirty seven patients had early gastric cancer and 536 had advanced gastric cancer. The diagnostic performance between CT and EUS for the T staging showed no significant difference between CT and EUS for the kappa values. The kappa values showed moderate agreement at 0.4039 (P=0.021) and 0.4201 (P=0.026), respectively. This suggests that there is no difference between the two examinations for the overall T staging. Analysis of the discrimination of mucosal and submucosal lesions with EUS showed an accuracy of 58.92% and a Kappa value of 0.206 (P<0.001), suggesting fair agreement and a lower diagnostic performance than expected. To differentiate lesions with stages higher than or equal to T2 or T3 from the lesion with stages lower than T2 or T3, respectively, adoption of the higher stage from the CT staging or the EUS staging showed a larger AUC of 0.84 than that from either stage alone. The CT-derived node stage had the higher diagnostic performance (68.55%) than that of the EUS-derived node stage (60.82%) for the node staging. Conclusion: The CT-derived stage and EUS-derived stage showed comparable results for determining the T stage of gastric cancer. Yet the higher stage of the two stages from CT and EUS most accurately discriminated between those lesions with stages higher than T2 and those lesions with stages lower than T2.

  • PDF

Changes in Allergenicity of Porcine Serum Albumin by Microwave, Sonication, and High Hydrostatic Pressure (Microwave, 초음파 및 초고압 처리에 의한 돼지 혈청 알부민의 항원성 변화)

  • Kim, Koth-Bong-Woo-Ri;Kim, Seo-Jin;Lee, So-Young;Song, Eu-Jin;Ahn, Dong-Hyun
    • Food Science of Animal Resources
    • /
    • v.28 no.4
    • /
    • pp.499-504
    • /
    • 2008
  • Even though pork have frequently induecd allergic reactions in Korea, few papers have been published on pork allergy. This study was carried out to investigate the changes in allergenicity of porcine serum albumin (PSA) by microwave, sonication, and high hydrostatic pressure (HHP). The binding ability of p-IgG to PSA treated with microwave (1,5, or 10 min) directly decreased with increasing treatment time. Particularly, the binding ability of PSA treated 10 min was about 30%. Immunoblotting assay with p-IgG showed that band of PSA treated microwave directly disappeared at 5 and 10 min. However, the binding ability of PSA was not changed by the microwave treatment without heat. Also the reduction of allergenicity by sonication or HHP treatment was not found. In conclusion. allergenicity of PSA treated with microwave directly decreased with increasing time, therefore these results may be used for development of hypoallergenic pork.

외국의 초음파 이용과 국내 현황

  • 김형철
    • 한우개량
    • /
    • no.5 s.26
    • /
    • pp.10-15
    • /
    • 2000
  • 초음파를 이용하여 가축의 생체 상태에서 도체형질을 추정하기 위한 연구가 50년대부터 시작되었다. 초기에는 초음파 반사파를 진폭으로 표시하는 방식인 A-mode(Amplitude-mode)를 이용하여 가축의 등지방두께 및 등심두께를 측정하였으며, 60년대부터 반사파의 강약을 명암으로 나타내는 B-mode (Brightness-mode) 방식으로 두께 및 면적을 측정하였다. 일본에서는 70년대 후반부터 등심 내 지방교잡을 조사하기 위한 연구가 활발하게 진행되었으나 미국, 유럽 등에서는 최근에서야 비로소 marbling 추정을 위한 연구가 시도되고 있다. 우리나라에서는 90년대 초부터 한우의 경쟁력을 높이기 위하여 육질향상에 중점을 두고 종모우의 조기 선발과 적정한 출하시기 판정에 초음파를 적용시키기 위한 연구가 여러 연구기관 및 학계에서 시도되었으나 인체에서 임신진단용으로 이용되거나 외국의 육우에 사용하던 기종을 한우에 적용시킴으로서 육질능력을 판정하는데 기계의 정확도가 많이 떨어지고 있는 실정이다.

  • PDF

A Study on the Effectiveness of Diagnostic Ultrasound Transmission Media (초음파진단시 초음파 전파매질의 유용성에 관한 연구)

  • Lee, Hye Nam;Lim, Cheong-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.187-188
    • /
    • 2014
  • 초음파 전파 매개물은 초음파의 손실 없는 투과력을 위한 1차적인 목적 이외에 피부위에서 탐촉소자의 부드러운 이동을 위한 부가적인 목적이 있다. 본 연구는 제형이 다른 진단초음파 전파매개물이 갖는 피부 윤활성, 피부 보습성, 건조속도 등의 초음파 매개물의 특징을 측정하고 비교하였다. 마찰계수는 점도가 높을수록 높았으며 제제의 건조속도는 고분자 수화젤이 가장 높았다. 오일 함유량이 많을수록 수분증발이 나타나지 않았다. 피부수분함량에서는 저점도 에멀전이 높은 수분함량을 나타냈으며 수분함량 감소 정도가 가장 완만히 나타났다. 오일성분을 적절히 사용한 에멀전 형태의 초음파 전파매개물은 피부 보습효과, 피부 유연작용의 피부 건강측면과 피부-탐촉소자간의 피부 윤활성면에서 효과적인 제형임을 알 수 있었다.

  • PDF

Estimation of Genetic Parameters for Ultrasound and Carcass Traits in Hanwoo (한우의 초음파 측정 형질과 도체 형질의 유전모수 추정)

  • Kim, Hyeong-Cheol;Lee, Seung-Hwan;Dang, Chang-Gwon;Jeon, Gi-Jun;Yeon, Seong-Heum;Cho, Young-Moo;Lee, Sang-Min;Yang, Boh-Suk;Kim, Jong-Bok
    • Journal of Animal Science and Technology
    • /
    • v.54 no.5
    • /
    • pp.331-336
    • /
    • 2012
  • This study was conducted to estimate genetic parameters for ultrasound and carcass traits in Hanwoo. Heritabilities and genetic and phenotypic correlations were estimated for carcass and ultrasound measurements collected from Hanwoo cows (n=312) born at Hanwoo experiment station. Traits evaluated were eye muscle area (EMA), backfat thickness (BF), marbling score (MS) from carcass, and ultrasound eye muscle area (UEMA), ultrasound backfat (UBF), and ultrasound marbling score (UMS). Parameters were estimated using multi-trait animal models byderivative-free restricted maximum likelihood procedures. Estimated heritabilities for UBF, UEMA and UMS were 0.43, 0.23 and 0.32, while heritabilities for BF, EMA and MS were 0.33, 0.13 and 0.33 in fattened cows, respectively. Genetic correlations between ultrasound and carcass measurements were estimated to -0.19, -0.61, and -0.36 for UBF: UEMA, UBF: UMS, and UEMA: UMS in fattened cows, respectively. Phenotypic correlations between ultrasound and carcass measurements were 0.03, 0.13 and 0.26 for UBF: UEMA, UBF: UMS, and UEMA: UMS in fattened cows, respectively. As for the steer, genetic correlations between ultrasound and carcass measurements were 0.36, -0.80 and 0.27 for UBF: UEMA, UBF: UMS, and UEMA: UMS in steers, respectively. Phenotypic correlations between ultrasound and carcass measurements were 0.13, 0.07 and 0.41 for UBF: UEMA, UBF: UMS, and UEMA: UMS in steers, respectively. In conclusion, this finding would be very useful to implement into Hanwoo breeding program.

회원사 탐방 - 일본, 유럽시장 등 세계 곳곳에 한국 세척기술을 심는다

  • Park, Ji-Yeon
    • The Optical Journal
    • /
    • s.119
    • /
    • pp.38-40
    • /
    • 2009
  • 일성초음파산업(대표 천홍현/www.isucl.co.kr)는 1985년 설립이래 23년간 광학전문 세척기 한 분야에서 축적해온 전문 기술력을 바탕으로 이제는 세계로 뻗어나가는 수출업체로 입지를 굳혔다. 까다롭기로 소문난 일본의 호야를 비롯한 전 세계 글로벌 회사들과 협력관계에 있는 일성초음파산업은 세계적인 광학세척기 전문업체로의 힘찬 도약을 시동하고 있다.

  • PDF

Noncontact Laser Ultrasonic Imaging for Automated Damage Detection (자동화 손상 검색을 위한 비접촉식 레이저 초음파 영상화)

  • Park, Byeong-Jin;An, Yun-Kyu;Sohn, Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.40-43
    • /
    • 2011
  • 최근, 레이저 초음파 영상화 기법은 구조물의 비접촉식 손상 진단을 위해 널리 연구되고 있다. 초음파 영상화 기법의 가장 큰 장점은 비접촉식으로 구조물의 손상을 진단할 수 있고, 가진 및 측정 지점을 자유로이 이동할 수 있다는 점이다. 따라서 이는 고온이나 동적상태의 구조물에 적용이 가능하며, 시간과 공간상의 충분한 데이터를 획득할 수 있으므로 역문제 (Inverse problem)를 해결할 필요 없이 완전한 초음파의 전파 형상을 얻을 수 있다. 지난 연구들에서는 충분한 가진력 혹은 측정 민감도를 확보하기 위해 가진 레이저와 부착형 센서의 조합이나 부착형 가진 트렌스듀서와 센싱 레이저의 조합으로 초음파 영상을 획득하고자 하였다. 하지만 이들 조합은 가진 혹은 측정 지점이 구조물에 부착되어 있어 완전한 비접촉식 기법을 구현하지 못하였다. 이를 극복하고자 레이저와 EMAT 센서 등의 조합이 시도되어 왔으나, 이 또한 EMAT 센서의 적용 거리에 따른 한계점을 지니고 있다. 본 연구에서는 가진 레이저 (Nd:Yag)의 스캐닝을 통해 다양한 가진 점에서 발생된 초음파가 탄성체 구조물을 통해 전파되고, 이를 센싱 레이저 (Laser Doppler Vibrometer)를 이용하여 측정함으로써 비접촉식 초음파 영상화를 구현하였다. 나아가, 정상파 필터(Standing-wave filter)를 이용하여 구현된 초음파 영상으로부터 손상 영향만 검출해 내는 기법을 개발했다. 개발된 기법은 복합재 시편의 층간박리 (Delamination) 진단을 통해 검증하였다.

  • PDF

Haptic Simulation Algorithm for Tooth Scaling Training (치아 스케일링 훈련을 위한 햅틱 시뮬레이션 알고리즘)

  • Cho, Jae-Hyun;Kim, Jai-Hyun;Park, Jin-Ah
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06b
    • /
    • pp.290-293
    • /
    • 2011
  • 치아 스케일링은 치아에 단단하게 결착된 치석을 제거하는 치과 시술로서 치아 우식 및 잇몸염증을 예방하는 중요한 시술이다. 특히 요즘에는 치료시간의 단축을 통한 효율성 증대의 목적으로 전기적 에너지를 미세한 진동에너지로 바꾸는 원리를 활용한 초음파 스케일링 기법이 많이 행해지고 있다. 하지만 치아 및 치석 확보에 따른 어려움으로 인해 스케일링 시술을 충분히 훈련하기란 쉽지 않다. 본 논문에서는 사용자가 가상현실을 통해 시각 및 촉각 피드백을 받으며 초음파 스케일링 시술을 훈련할 수 있는 치아 스케일링 시뮬레이션을 위한 알고리즘을 제안한다. 치아, 치석 및 잇몸의 볼륨모델과 스케이러 팁을 구성하는 각 부문의 관통깊이를 이용한 햅틱 랜더링 기법을 적용하여 스케일러의 모양에 따른 햅틱 피드백을 생성하였다. 그리고 치아의 손상을 줄이기 위해 스케일러의 팁 부문이 치아 표면에 되도록 평형을 이루어야 한다는 점에 입각하여, 치석을 구성하는 복셀들의 치아 디스턴스필드 값 비교를 통해 치석과 치아 사이의 접착면을 추출하고 스케일러의 팁 부분과 충돌하는 추출된 집착면의 각도를 고려한 스케일링 알고리즘을 구현하였다. 또한 수동 스케일링과는 달리 초음파 스케일링은 초음파의 진동에너지에 의해 점진적으로 치아와 치석 사이의 결속력이 감소된다는 점에 착안하여 치아와 치석의 접착면을 구성하는 지점 사이의 거리에 따른 결속력 감쇠 모델을 고안하였다.

Ultrasonically Enhanced Stabilization of Soft Clay (초음파를 이용한 연약지반 안정화 촉진)

  • Kim, Young-Uk;Kim, Byoung-Il;Song, Young-Karb
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.684-691
    • /
    • 2004
  • Various researches have been undertaken to develope a method of enhancing consolidation. This study investigated the effect of ultrasound on consolidation through a series of laboratory experiments. The tests were conducted using a specially designed and fabricated equipments which can apply ultrasonic energy on a soil sample at consolidation test. Specimens were prepared using a centrifuge facility, and test conditions included ultrasonic power and treatment time. The results of the study show that the effect of ultrasonic energy on consolidation is significant. The degree of significance varies with the test conditions. It could be concluded that the study showed potential application of ultrasound to enhance consolidation.

  • PDF

Estimation of the Axial Stress in High-Tension Bolt by Acoustoelastic Method (음탄성법을 이용한 고장력 볼트의 축응력 평가)

  • Chun, Hae-Hwa;Lee, Tae-Hoon;Jhang, Kyung-Young;Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.285-290
    • /
    • 2006
  • The evaluation of clamping condition has been regarded as the main issue in the safety-maintenance of the clamped high-tension bolts. For this, this paper proposes a method to estimate the axial stress by measuring the TOF (Time-Of-Flight) of ultrasonic wave, which is based on the acoustoelasticity or the dependency of sound speed on the stress. In this method, however, the variation of sound speed within the range of stress induced under the field condition is very small, and thus the accuracy of the TOF measurement is important. We adopted the phase detection method using tone-burst ultrasonic wave to measure the precise TOF. In order to verify the usefulness of the proposed method experiments are carried out and the results were compared with the stress measured by the strain gage. The results show good agreement with each other, and from these we can conclude that the proposed method is highly useful fnr the evaluation of clamping condition in the clamped high-tension bolts.