• Title/Summary/Keyword: 초기 비정상 유동

Search Result 33, Processing Time 0.021 seconds

A Study on Algorithm to Improve Accuracy of Initial Track Beam Steering Using Radar Radial Velocity Measurement (레이다 시선속도 측정치를 활용한 초기 추적 빔 조향 정확도 향상 알고리즘 연구)

  • Yoo, Dong-Gil;Hyun, Jun-Seok;Cho, In-Cheol;Sohn, Sung-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.4
    • /
    • pp.63-73
    • /
    • 2021
  • The radar operated to detect/track aircraft targets is divided into a search radar that operates while the antenna rotating device rotates for the purpose of detecting the target according to the mission characteristics, and a tracking radar that periodically steers and tracks a beam to the predicted position of the target. The tracking radar has a shorter target information acquisition preiod than the search radar. Due to this characteristic, the tracking accuracy is better than that of the search radar, but as the prediction error increases due to the speed error at the beginning of the tracking, there are many cases in which tracking fails at the beginning of tracking due to failure to perform beam steering normally. In this paper, in order to solve the above-mentioned problems, we propose an algorithm for improving the accuracy of track initiation using radial velocity measurements in addition to the position of the measured, and confirm the performance of the proposed algorithm by comparing with the two point differential algorithm

Estimation of Local Stress Change of Wall-Thinned Pipes due to Fluid Flow (유체유동에 의한 감육배관의 국부응력변화 평가)

  • Kim Young-Jin;Song Ki-Hun;Lee Sang-Min;Chang Yoon-Suk;Choi Jae-Boong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.7-12
    • /
    • 2006
  • In this paper, a new evaluation scheme is suggested to estimate load-carrying capacities of wall thinned pipes. At first, computational fluid dynamics analyses employing steady-state and incompressible flow are carried out to determine pressure distributions in accordance with conveying fluid. Then, the variational pressures are applied as input condition of structural finite element analyses to calculate local stresses at the deepest point. The efficiency of proposed scheme was proven from comparison to conventional analyses results and it is recommended to consider the fluid structure interaction effect for exact integrity evaluation.

  • PDF

Study on Transient Analysis of Hot Gas Valve with Pintle (핀틀이 적용된 고온 가스 밸브의 비정상상태 해석 기법에 관한 연구)

  • Lee, Kyungwook;Heo, Seonuk;Kwon, Sejin;Lee, Jongkwang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.2
    • /
    • pp.152-159
    • /
    • 2018
  • A numerical simulation was conducted to establish the analysis methods of the unsteady conjugated heat transfer with a hot gas valve. Two methods are proposed to reduce the computational cost and analysis time of the unsteady conjugate heat transfer; namely, the multi-section analysis method and the one-way analysis method. The multi-section analysis method exhibits relatively high reliability. In the one-way analysis method, the unsteady conjugate heat transfer from the fluid domain to the solid domain was simulated from the analysis results of the steady-state flowfield. The incipient accuracy of the analysis results obtained by the one-way analysis method was slightly lower than that of the results obtained by the multi-section analysis method. However, the discrepancy became smaller with time, as the analysis progressed.

Heat Transfer on a Jet Vane Surface Installed in a Rocket Nozzle (로켓노즐에 장착된 제트베인 표면의 열전달 특성)

  • Yu Man Sun;Cho Hyung Hee;Hwang Ki Young;Bae Ju Chan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • Jet vane is an useful component which is installed at the end of a nozzle for the purpose of the posture control and the secure controlling stability during the initial launching of a rocket. During several seconds from its initial launching moment, the JV driving part is heated due to the direct contact of the vane with the combusted gas and the vane is ablated mechanically or chemically. In this study, as the fundamental study for the thermal analysis of jet vane, the heat transfer into a jet vane which is located in the uniform supersonic flow field is calculated. For this, boundary layer integral method and finite difference method are used simultaneously. Based on the thermal boundary conditions derived from the analysis, the transient heat conduction in the vane is also calculated.

Evaluation of Offshore Water Quality by Bioassay Using the Gametes and Embryos of Sea Urchins (성게 알을 이용한 생물검정에 의한 연안해수 수질평가에 관한 연구)

  • Yu, Chun-Man
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.3
    • /
    • pp.170-174
    • /
    • 1998
  • The water quality of offshore waters around the Korean coast was evaluated by bioassay using gametes, embryoss and early development systems of a sea urchin species Hemicentrotus pulcherrimus. The results show that despite the inflows of several river systems, the west coast maintain the grade II water. This is thought to be due to the decrease in pollutant input resulting from the purification of inflow rivers (e.g., the control of waste water discharge and the construction of sewage treatment facilities), and the dilution of pollutants by a strong tidal mixing with a large difference between the ebb and flood tides. However, Asan, Hampyong and Chonsu bays, where circulations of water are relatively poor, and the Kunsan and Mokpo harbors which are influenced by pollutants from neighboring cities have shown the grade III water. The south coast has maintain the grade II or III because developments of sea urchins were moderately or strongly inhibited. Also, Kangjin, Duekryang, Kwangyang, Masan, and Jinhae bays where water circulations are relatively poor, show the grade III water, with strong inhibitions of the early development of sea urchins. The east coast has maintained the grade I and II due to monotonous coastlines and smooth circulation of sea water. However, Chongcho Lake shows the worst water quality due to the breakwater which is constructed to maintain port functions.

  • PDF

Forced Vibration and Structural Response Prediction for Impeller in Resonant Conditions due to Diffuser Vanes (디퓨저 베인에 기인한 공진조건에서의 임펠러 강제진동 및 구조응답 예측)

  • Kim, Yongse;Kong, Dongjae;Shin, SangJoon;Park, Kihoon;Im, Kangsoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.24-35
    • /
    • 2018
  • Impeller blades in the centrifugal compressor are subjected to periodic aerodynamic excitations by interactions between the impeller and the diffuser vanes (DV) in resonant conditions. This may cause high cycle fatigue (HCF) and eventually result in failure of the blades. In order to predict the structural response accurately, the aerodynamic excitation and the major resonant conditions were predicted using unsteady computational fluid dynamics (CFD) and structural analysis. Then, a forced vibration analysis was performed by going through one-way fluid-structure interaction (FSI). A numerical analysis procedure was established to evaluate the structural safety with respect to HCF. The numerical analysis procedure proposed in this paper is expected to contribute toward preventing HCF problems in the initial design stage of an impeller.

An Analysis of Groundwater Flow at Bugok Area Using MODFLOW (MODFLOW 모형을 이용한 부곡온천지역 지하수 유동해석)

  • Chung, Sang-Ok;Lee, Young-Dae;Min, Byung-Hyung
    • Water for future
    • /
    • v.27 no.1
    • /
    • pp.79-88
    • /
    • 1994
  • This study was conducted to analyse groundwater flow in the Bugok hot spring area using the MODFLOW model which can simulate three dimensional groundwater flow both in confined and unconfined aquifers. Based on this study the following conclusions were obtained: 1) The hydraulic conductivity and the specific storage of the aquifer were 0.0135 m/day and 0.020, respectively, and the model-predicted groundwater elevation agreed well with the observed one. 2) Simulation results showed that the groundwater level declines at the end of the one-year simulation period when the annual recharge rate is small and the annual pumping rate high, which is the worst combination. Except that combination, the groundwater level does not decline at the end of one-year simulation period indication the pumping rates used were allowable. 3) The safe yield depends upon the magnitudes of the recharge and pumping rates. The pumping rate should not produce excess decline of groundwater level around April when the water level is the lowest in a year.

  • PDF

Dehydration of Solid Food Material Immersed in Fluidized-Bed (유동층(流動層)에 의한 고체식품(固體食品)의 건조(乾燥))

  • Yu, Ju-Hyun;Lee, Shin-Young;Pyun, Yu-Ryang;Yang, Ryung
    • Korean Journal of Food Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.398-403
    • /
    • 1978
  • Squid was dried on the fluidized-bed in the drying chamber filled with solid particles which were also fluidized with hot-air, and effects of the fluidized particles, the squid's height from the grid and the drying temperature on the drying rate and quality of the squid were observed The mechanism of moisture transfer during the falling rate period was also derived. 1. Sodium chloride was found to be the most suitable fluidized particles and at an air velocity of 3.8 m/sec, optimal fluidization state of this particle was obtained. 2. Uniform profiles of temperature were obtained at a point 4 cm above the grid and the location of squid on the fluidized-bed observed to be suitable when it was 4 cm above the grid. 3. At an air velocity of 3.8 m/sec and when the location height of the squid on the fluidized-bed was 4 cm, the optimal temperature for the drying time which is required to reduce the moisture from 80.8% to 18-22% was 8.5 hours. 4. Drying data followed the empirical equation of unsteady state diffusion $log\;(\frac{W-We}{Wc-We})=-m{\theta}$ in the region of the moisture contents measured and the drying constant (m) was calculated as $0.32hr^{-1}$. These results suggested that the migration of moisture during the falling rate period is due to a diffusion type mechanism. 5. The short constant rate period was observed in the early stage and thereafter, drying was controlled by the falling rate period, and the time ratio of the fluidized bed drying to the through circulation drying for reducing the squid's moisture contents to the same level at the same drying temperature was 1 : 1.4 6. Comparisons of fluidized-bed dried squid and sun dried squid in sale showed that there was no significant change in qualities such as external appearance and hydrogen ion concentration of dry product.

  • PDF

Study of Application of Impulse Turbine with Staggered Blades to Improve the Performance for Wave Energy Conversion (파력발전용 임펄스터빈의 효율 향상을 위한 Staggered Blade의 적용에 대한 연구)

  • Moon, Jae-Seung;Shin, Seung-Ho;Hyun, Beom-Soo;Kim, Gil-Won;Hong, Key-Yong
    • Journal of Navigation and Port Research
    • /
    • v.31 no.10
    • /
    • pp.845-852
    • /
    • 2007
  • An OWC-type Wave Energy Conversion passes through 3 steps energy conversion process. This paper deal with the impulse turbine with staggered blade to improved performance by numerical analysis using commercial CFD code, FLUENT Maximum value of axial airflow velocity during exhalation is higher than that during inhalation This paper deal with special-type of Impulse Turbine so-called "Staggered Blade" for more efficiency to making air flow direct to on pressure side. Also, this paper has proposed special-type turbine with self-pitched blade more efficient.

Investigation of Turbulent Analysis Methods for CFD of Gas Dispersion Around a Building (건물주위의 가스 확산사고에 대한 CFD 난류 해석기법 검토)

  • Ko, Min Wook;Oh, Chang Bo;Han, Youn Shik;Do, Kyu Hyung
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.42-50
    • /
    • 2015
  • Three simulation approaches for turbulence were applied for the computation of propane dispersion in a simplified real-scale urban area with one building:, Large Eddy Simulation (LES), Detached Eddy Simulation (DES), and Unsteady Reynolds Averaged Navier-Stokes (RANS). The computations were performed using FLUENT 14, and the grid system was made with ICEM-CFD. The propane distribution depended on the prediction performance of the three simulation approaches for the eddy structure around the building. LES and DES showed relatively similar results for the eddy structure and propane distribution, while the RANS prediction of the propane distribution was unrealistic. RANS was found to be inappropriate for computation of the gas dispersion process due to poor prediction performance for the unsteady turbulence. Considering the computational results and cost, DES is believed to be the optimal choice for computation of the gas dispersion in a real-scale space.