• Title/Summary/Keyword: 초기골유합

Search Result 5, Processing Time 0.018 seconds

Comparison of Results Between Immediate Fixation Group and Delayed Reconstruction Group in Displaced Mid-shaft Fractures of the Clavicle (쇄골 전위성 간부 골절에서 조기 고정술 군과 지연 재건술 군 간의 결과 비교)

  • Kim, Doo-Sub;Rah, Jung-Ho;Yoon, Yeo-Seung;Lee, Chang-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.61-66
    • /
    • 2009
  • Purpose: Several authors have reported excellent results of delayed reconstruction of non-union & malunion in displaced mid-shaft fractures of the clavicle and these results were equal to that of immediate fixation. But direct comparison between these treatments is rare. We evaluated the results between the immediate fixation group and delayed reconstruction group for treating displaced mid-shaft fractures of the clavicle. Materials and Methods: We studied the results of 18 cases with immediate fixation of displaced mid-shaft fractures of the clavicle and 15 cases with delayed reconstruction of non-union & malunion after conservative management, and these cases were seen from March 2000 to February, 2006. The final postoperative outcome was analyzed according to the clinical outcomes with using the Constant score and the radiological findings of bony union. Results: The constant score was low in the delayed reconstruction group compare to that of the immediate fixation group (p value=0.045). For the pain score & the activities of daily living score, a statistically significant difference was seen between the two groups (p<0.05), but not for the range of motion score & the power score (p>0.05). Radiological findings of bony union were seen for both groups at an average of 8.8 weeks for the immediate fixation group and at an average of 9.8 weeks for the delayed reconstruction group. Conclusion: Though the delayed reconstruction group was shown good clinical and radiological results, the immediate fixation group had a significantly better pain score, a better activities of daily living score and a better Constant score. It is important to choose the initial treatment option for displaced mid-shaft fractures of the clavicle after sufficient explanation to patients about the merits and demerits between these two treatment options.

In vivo assessment of Fibroblast growth factor(FGF)-Fibronectin fusion protein coating on titanium;Histomorphometric analysis in rabbit tibia (섬유아세포 성장인자와 파이브로넥틴 복합 단백질로 처리한 타이태늄의 생물학적 효과;가토의 경골을 이용한 조직계측학적 분석)

  • Na, Ho-Kyun;Kim, Tae-Il;Lim, Sang-Hoon;Cho, Ki-Young;Chung, Chong-Pyoung;Han, Soo-Boo;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.153-161
    • /
    • 2005
  • 파이브로넥틴은 세포외기질에 존재하는 당단백질로 세포의 부착, 이동, 성장 및 분화에 관여하며, 섬유아세포 성장인자는 세포의 증식 이동 및 분화에 영향을 주는 중요한 성장인자로 알려져 있다. 최근 연구에 의하면, 파이브로넥틴은 조골세포의 타이태늄 임플란트 표면으로 이주와 증식 및 골생성을 촉진하며, 섬유아세포 성장 인자는 파이브로넥틴에 상승작용을 한다고 보고된 바 있다. 이 실험의 목적은 파이브로넥틴 및 섬유아세포 성장인자의 복합 단백질을 이용하여 타이태늄 임플란트의 골 반응을 알아보는 것이다. 체중 2.5 kg 내외의 건강한 18 마리의 웅성가토를 준비하여 무균 사육하였고, 순수 타이태늄을 절삭가공하여 직경 3.5mm, 길이 6mm 의 machined surface를 지니는 screw type 의 임플란트를 준비하였다. 사람의 유전자를 기초로, 유전자 재조합법을 통해, 적절한 primer를 이용하여 얻은 섬유아세포 성장인자를 파이브로넥틴 III 형 분절의 9-10 번 도메인에 결합시켜 얻은 복합 단백질을 준비된 임플란트에 표면처리하여 실험군으로 하였고, 표면처리하지 않은 임플란트를 대조군으로 하여, 가토의 좌우 경골에 각각 2 개씩의 임플란트를 식립하였다. 4주 후, 가토를 희생시켜 각 경골 당 한 개의 임플란트에서 뒤틀림 제거력을 측정하였고 나머지 임플란트 식립 부위 에서는 경골을 포함하는 조직표본을 제작하였다. 조직표본상에서 골접촉이 가장 좋은 3 개의 나사산의 길이를 측정하고, 나사와 접촉하는 골의 길이를 측정하여 골-임플란트 접촉도를 구하고, 같은 부위에서 나사산 사이의 면적과 골이 차지하는 면적을 비교하여 골생성률을 얻었다. 실험군과 대조군의 결과는 Student t-test 를 이용하여 신뢰도 95% 수준에서 통계학적 유의성을 검정하였다. 파이브로넥틴과 섬유아세포 성장인자의 복합 단백질로 표면처리된 임플란트와 표면처리를 하지 않은 임플란트는 뒤틀림 제거력에서는 통계적 유의성이 나타나지 않았으나, 골-임플란트 접촉도와 골생성률에서 복합 단백질로 처리된 임플란트가 통계적으로 유의하게 높은 결과를 보였다. 이상의 연구결과로, 섬유아세포 성장인자와 파이브로넥틴 복합 단백질로 처리한 타이태늄 임플란트가 주변 골 형성을 촉진시켜, 골유합을 증진시킴을 알 수 있었다. 따라서, 복합 단백질이 타이태늄 임플란트의 성공률을 높이기 위한 표면개질 물질로 이용될 가능성을 확인할 수 있었다.

The Effect of Microcurrent Stimulation on Expression of BMP-4 After Tibia Fracture in Rabbits (미세전류가 토끼 경골의 골절 후 BMP-4 발현에 미치는 영향)

  • Cho, Mi-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.196-203
    • /
    • 2010
  • This study aimed to examine the effect of microcurrent stimulation on expression of Bone Morphogenetic Protein(BMP) 4 after tibia fracture in rabbits. The twenty four adult 6 month old New Zealand white rabbits weighting 2.5~3.5 ㎏ were used. Twenty four rabbits with tibia fracture were randomly divided into control and experimental groups. Each group was divided into four subgroups, based on the duration of the experiment (3, 7, 14, 28 days). The experimental groups received microcurrent stimulation of 20~25 ${\mu}A$ intensity with surface Ag-AgCl electrode (diameter 1cm, Biopac, U.S.A.) for 24 hours a day. Cathode of the microcurrent stimulator located on the tibia directly, anode of it did on the gastrocnemius muscle. After evaluation, the test results are as follows: Comparisons of immunohistochemical observation of BMP-4 in 7 days after tibial fracture show that there was shown to be a moderate positive reaction (++) on concentric circles of Harversian system and the interstitial lamella in the control group, while there was a very strong positive reaction () on concentric circles of Harversian system and interstitial lamellain the experimental group. These results suggest that applying non-invasive constant microcurrent stimulation on fractured bone is helpful to bone healing.

Coracoclavicular Ligament Augmentation Using Endobutton for Unstable Distal Clavicle Fractures - Preliminary Report - (불안정성 쇄골 원위부 골절에서의 Endobutton을 이용한 오구 쇄골 인대 보강술 - 예비 보고 -)

  • Cho, Chul-Hyun;Jung, Gu-Hee;Sin, Hong-Kwan;Lee, Young-Kuk;Park, Jin-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the radiologic and clinical outcomes after operative treatment using endobuttons for unstable distal clavicle fractures. Materials and Methods: Between October 2007 and September 2009, 9 consecutive patients who were followed up for at least more than 12 months after operative treatment using a TightRope$^{(R)}$ were studied. The radiologic results on the serial plain radiographs and the clinical results according to the American Shoulder Elbow Surgeons (ASES) score were analyzed. Result: Bony union was shown in 8 cases (88.9%) and the average time to union was 12.9 (range: 9~16) weeks. The average coracoclavicular distances at the postoperative and final follow-up were 5.6 mm and 6.2 mm, respectively, with no statistically significant difference (p>0.05). The average ASES score was 90.3 (range: 78~96) and the clinical outcomes were 6 excellent, 2 good and one fair. There were no complications such as implant failure or infection except for one case of nonunion due to loss of the initial reduction. Conclusion: A major advantage of TightRope$^{(R)}$ fixation for unstable distal clavicle fractures is that no further surgery is needed to remove the implant. We suggest that this technique provides an alternative for fracture with a distal fragment, which is difficult to fix.

A Comparison between Minimally Invasive Percutaneous Plate Osteosynthesis and Plate Fixation in the Treatment of Clavicle Midshaft Fracture (쇄골 간부 골절의 최소 침습적 경피적 금속판 고정술과 관혈적 수술 비교)

  • Yoo, Seong-Ho;Kang, Suk-Woong;Kim, Bu-Hwan;Song, Moo-Ho;Kim, Yeong-Joon;Park, Gyu-Taek;Kwack, Chang-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Purpose: To retrospectively compare minimally invasive percutaneous plate osteosynthesis (MIPPO) with open plate fixation for the treatment of clavicle midshaft fracture. Materials and Methods: Between November 2011 to May 2014, 40 cases that were followed for more than 1 year-among all cases of MIPPO and open plate fixation-were analyzed. The study population was divided into two groups: group A included 20 cases of MIPPO and group B included 20 open plate fixation cases. The comparative analysis between the two groups was based on the operative time, bone union, functional evaluation (American Shoulder and Elbow Society score), incision length, pain relief (visual analogue scale, VAS), and complication. Results: The bone union was successful for all the cases, and the functional evaluation scores of the shoulder joint were satisfactory for both groups (p>0.05). The operative time was 47.5 minutes and 58.7 minutes for group A and B, respectively (p<0.05). The incision length for group A was 6.2 cm and that for group B was 10.7 cm with statistical significance (p<0.05). Pain relief (VAS) after surgery for group A showed a quick recuperation in the early stages. For complications, there were 2 cases of dysesthesia and 1 case of malunion due to metal fixation failure in group A. There were 6 cases of dysesthesia and 2 cases of cosmetic problem due to hypertrophic scar in group B. Conclusion: Surgical results of clavicle shaft fracture were satisfactory for both groups, but group A had advantages of shorter operative time, minimal incision length, and better pain relief in the early stages compared with group B. However, we need further evaluations with long-term follow-up results and complications, such as malunion and exposure on radiation.