• Title/Summary/Keyword: 청성뇌간반응 검사

Search Result 14, Processing Time 0.02 seconds

Development of A-ABR System Using a Microprocessor (마이크로프로세서를 이용한 자동청력검사 시스템 개발)

  • Noh, Hyung-Wook;Lee, Tak-Hyung;Kim, Nam-Hyun;Kim, Soo-Chan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.15-21
    • /
    • 2009
  • Hearing loss is one of the most common birth defects among infants. Most of hearing-impaired children are not diagnosed until 1 to 3 years of age - which is too late for the critical period (6 month) for normal speech and language development. If a hearing impairment is identified and treated in its early stage, child's speech and language skills could be comparable to his or her normal-hearing peers. For these reasons, hearing screening at birth and throughout childhood is extremely important. ABR (Auditory brain-stem response) is nowadays one of the most reliable diagnostic tools in the early detection of hearing impairment. In this study, we have developed the system that automatically detects if there is hearing impairment or not for infants or children. For future studies, it will be developed as a portable system to be able to take a measurement not only in sound proof room but also in nursery for neonates.

Oral Sildenafil in Persistent Pulmonary Hypertension of the Newborn (신생아의 지속성 폐동맥 고혈압증에서 Sildenafil 치료 경험)

  • Son, Su-Bin;Kim, Kyung-Ah;Yun, So-Young;Ko, Sun-Young;Lee, Yeon-Kyung;Shin, Son-Moon
    • Neonatal Medicine
    • /
    • v.18 no.1
    • /
    • pp.124-129
    • /
    • 2011
  • Purpose: To evaluate the effect of oral sildenafil therapy in neonates with persistent pulmonary hypertension of the newborn (PPHN) Methods: We conducted a retrospective review of 32 neonates ${\geq}$35 weeks' gestation and fraction of inspired oxygen ($FiO_2$) 1.0 with PPHN. The first dose (0.5 mg/kg) of oral sildenafil was started and 1 mg/kg was given every 6 hour thereafter. Mean airway pressure (MAP), $FiO_2$, oxygenation index (OI), mean arterial blood pressure (MBP) were documented before and 6, 12, 24, and 48 hours after sildenafil. For adverse effects, gastrointestinal symptoms, brain ultrasound, funduscopy and auditory brainstem response results were evaluated. Results: The underlying diseases of PPHN (n=32) were meconium aspiration syndrome (n=9), respiratory distress syndrome (n=8), pneumonia (n=3), and idiopathic (n=12). Thirty-one neonates survived; 3 neonates were transferred for inhaled nitric oxide (iNO) and all of them survived. In 28 infants, $FiO_2$ and OI improved significantly by 6 hours and MAP improved significantly by 48 hours after initiation of sildenafil. There were no clinically significant adverse effects of sildenafil. Conclusion: Sildenafil may be an effective and safe agent for near-term and term neonates with PPHN, providing significant improvement in oxygenation, and thus may be especially useful in the treatment of PPHN in hospitals without iNO.

Development and Assesment of an Embedded Portable A-ABR System (임베디드 기반의 휴대용 A-ABR 시스템 개발 및 평가)

  • Noh, Hyung-Wook;Nam, Ki-Chang;Jang, Kyung-Hwan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.48-55
    • /
    • 2010
  • Hearing impairment is one of the most common birth defects among infants. Significant bilateral hearing impairment have profound effects on speech and language development. But it can be prevented, if a hearing impairment is identified and treated in its early stage. ABR (auditory brainstem response) is useful screening tool for new born hearing test. However, the interpretation of conventional ABR should be done by a experienced audiologist and testing takes some time. Therefore, A-ABR(automated ABR) which detect ABR peak automatically have been developed recently. In contrast to A-ABR researches became active in overseas, there has been little study in Korea. In this study, we have developed a portable A-ABR system based on the results of our previous study. For the evaluation of the developed system, the clinical trials were performed on adults and infants. As a results, it showed good sensitivity (94.4%) and specificity (92.2%), and accuracy (93.0%) between clinical diagnosis and the developed A-ABR test.

Usefulness of auditory brainstem response as early predictor of kernicterus in early breast-feeding jaundice (조기 모유 황달에서 핵황달의 조기 예측도구로서의 청성 뇌간유발 반응 검사의 유용성)

  • Jang, Jae Won;Lee, Gil Sang;Song, Dae Keun;Kim, Sung Hee;Kim, Won Duck;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.9
    • /
    • pp.848-854
    • /
    • 2007
  • Purpose : The present study examined the etiology and risk factors of the early breast-feeding jaundice and the usefulness of auditory brainstem response test as early predictor of kernicterus. Methods : Medical records of neonatal jaundice in newborn admitted to Daegu Fatima Hospital between September 2005 and May 2006 were analyzed prospectively. Infants were grouped according to feeding method : breast feeding group (breast feeding only, n=23), mixed feeding group (breast feeding mainly plus addition of fomula feeding, n=13). Results : There were no significant differences in gestational age, birth weight, sex, duration of phototherapy, serum bilirubin and hemolytic evidence between the two study groups. First visiting day of life at out patient department was significantly delayed in breast feeding group ($8.7{\pm}3.6day$) compared to mixed feeding group ($6.0{\pm}1.9$) (P=0.009). Weight loss was significantly severe in breast feeding group compared to mixed feeding group (P<0.05). In auditory brainstem response test, loss of Wave V in 3 cases was observed and recoverd after blood exchange transfusion in follow up test.Wave III latency had significant correlation to serum bilirubin in auditory brainstem response test (70 dB) (P=0.002). Conclusion : Our study suggest that further education about breast feeding and follow up within the first postnatal week would be necessary for early detection and prevention of early breast-feeding jaundice. Test of serum bilirubin and auditory brainstem response would be helpful in determination of blood exchange transfusion.