Analysis of Signal Transfer Characteristics of Implantable Middle Ear System using Acoustic Model (청각모델을 이용한 이식형 인공중이 시스템의 신호 전달 특성 해석)

  • 송병섭;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.227-233
    • /
    • 2002
  • The IME(implantable middle ear) system is Promising due to its ability to free from sound feedback and Produce a good sound quality and intelligibility with low distortion even if it is operated with high gain for severe hearing impaired. The differential electromagnetic vibration transducer. which was developed for using in IME system and has two small magnets attached the same Pole facing in the coil. is not influenced by environmental external magnetic field. Besides, it has high vibration efficiency and good frequency response characteristics. In this Paper, using acoustic model of the transducer and ear model of normal Person. the signal transfer characteristics of the IME system are analyzed and investigated From the differences of the characteristics between normal ear and the IME system, it is Possible that design of the IME system that have the signal transfer characteristics similar to normal person's ear.

The Hearing Ability of Dusky Spinefoot Siganus fuscescens to Audible Sound 1. The Auditory Threshold (가청음에 의한 독가시치의 청각 능력 1. 청각 문턱치)

  • 이창헌;문종욱;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.4
    • /
    • pp.309-313
    • /
    • 2000
  • A experiment was carried out to measure the auditory threshold of dusky spinefoot Siganus fuscescens(Houttuyn) in the coast of Cheju Island by heartbeat conditioning technique using pure tones coupled with a delayed electric shock in order to investigate the hearing ability to audible sound. The audible range of dusky spinefoot extended from 80Hz to 800Mhz with a peak sensitivity at 200Hz. The mean auditory threshold levels of dusky spinefuot were 102dB, 96dB, 92dB, 95dB, 105dB and 121dB respectively in the range of measurement frequencies, As the frequency became higher than 300Hz, the auditory threshold increased rapidly.

  • PDF

The Expository Dictionary using the Sign Language about Information Communication for Deaf (청각장애인을 위한 정보통신용어 수화해설 사전)

  • Kim Ho-Yong;Seo Yeong-Geon
    • Journal of Digital Contents Society
    • /
    • v.6 no.4
    • /
    • pp.217-222
    • /
    • 2005
  • The purpose of this study is to design and implement a sign language dictionary for the deaf to understand information communication terminologies. When the deafs who have difficulties in communication use the internet, they an get help from this dictionary in accessing various types of information and expressing their intension. In order for the deaf to utilize the internet as efficiently as ordinary people, they must understand information communication terminologies first In order to implement the dictionary, we defined the concepts of the deaf and examined their characteristics. In addition, we established principles in designing this dictionary and selected some terminologies. When explaining the terminologies. we tried to use expressions common to the deaf, but sometimes modified them to keep the original meanings of the terms in producing sign language videos. This studies are applied as learning aid to information education for the deaf, and the deaf's understanding of ICT was measured through two tests.

  • PDF

The Analysis of Sound Attributes on Sensibility Dimensions (소리의 청각적 속성에 따른 감성차원 분석)

  • Han Kwang-Hee;Lee Ju-Hwan
    • Science of Emotion and Sensibility
    • /
    • v.9 no.1
    • /
    • pp.9-17
    • /
    • 2006
  • As is commonly said, music is 'language of emotions.' It is because sound is a plentiful modality to communicate the human sensibility information. However, most researches of auditory displays were focused on improving efficiency on user's performance data such as performance time and accuracy. Recently, many of researchers in auditory displays acknowledge that individual preference and sensible satisfaction may be a more important factor than the performance data. On this ground, in the present study we constructed the sound sensibility dimensions ('Pleasure', 'Complexity', and 'Activity') and systematically examined the attributes of sound on the sensibility dimensions and analyzed the meanings. As a result, sound sensibility dimensions depended on each sound attributes , and some sound attributes interact with one another. Consequently, the results of the present study will provide the useful possibilities of applying the affective influence in the field of auditory displays needing the applications of the sensibility information according to the sound attributes.

  • PDF

Development of a Bone Conduction Telephone for Conductive Hearing Impaired Persons and its Performance Test (전음성 청각장애인용 골도 전화기 개발 및 성능 평가)

  • Kang, Kyeong-Ok;Kang, Seong-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.113-122
    • /
    • 1995
  • This paper describes characteristics of a bone conduction telephone which was developed for conductive hearing impaired persons to call without additional devices and results of its performance test. Not only the hearing impaired but also normal hearing persons can use this telephone because we developed a bone conduction vibrator with which they can perceive speech signal using functions of air conductive hearing as well as bone conductive hearing. It also has tone control function compensating hearing losses for the hearing impaired originating from their hearing characteristics, and using this function together with received volume control it has received volume range of 20dB in loudness rating, which is similar effect as what a telephone set with built-in received amplifier has. From results of articulation and intelligibility tests for 19 hearing impaired persons, we can see that if their bone-conduction hearing loss is 61dB or less, they can understand words or sentences and response well with this telephone.

  • PDF

Study on Sound Quality Improvement in Bluetooth Headset (블루투스 헤드셋에서의 음질 향상에 관한 연구 - 개인 청각손실 방지측면 고려 -)

  • Kim, Hyun-Tae;Park, Jang-Sik;Song, Jong-Kwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1188-1193
    • /
    • 2009
  • Todays, many young people suffer from noise-induced hearing loss by using wearable hearing devices, such as Bluetooth headset. This paper present hearing loss reduction and more natural volumn control algorithms considering individual hearing characteristics and threshold of feeling for Bluetooth headset. Experimental results using CSR Bluetooth headset example design board(DEV-PC-1645) show that individuals maybe able to perceive without the inconvenience at the less sound intensity and the more sensitive frequency bands. As a result, we may prevent hearing loss to reduce excessive sound energy in each frequency bands.

Development of Hearing Loss Reduction Algorithms for Bluetooth Headset (블루투스 헤드셋용 청각 손실 방지 알고리즘 개발)

  • Kang, Jeong-eun;Kim, Hyun-tae;Park, Jang-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.383-386
    • /
    • 2009
  • Todays, many young people suffer from noise-induced hearing loss by using wearable hearing devices, such as Bluetooth headset. This paper present hearing loss reduction algorithms considering individual hearing characteristics and threshold of feeling for Bluetooth headset. Experimental results using CSR Bluetooth headset example design board(DEV-PC-1645) show that individuals may be able to perceive without the inconvenience at the less sound intensity and the more sensitive frequency bands. As a result, we may prevent hearing loss to reduce excessive sound energy in each frequency bands.

  • PDF

Piano Sound Compression Algorithm Using Auditory Characteristics (청각 특성을 이용한 피아노 음원 압축 알고리듬)

  • 김기수
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.265-269
    • /
    • 1993
  • 디지틀 피아노에서 PCM 방식의 음원 합성을 위한 압축 알고리듬을 제안하였다. 디지틀 피아노는 매우 높은 음질을 필요로 한다. 따라서 FM 방식보다는 PCM 방식의 음원 합성 알고리듬이 주로 사용되어져 왔다. 그러나 PCM 방식은 많은 메모리가 필요한 단점이 있다. 본 논문에서는 피아노 음원을 청각적으로 왜곡이 없도록 압축, 저장하여 음원 데이터를 줄였다. 또한 피아노 음의 시간 영역 특성에 따라 비트 할당을 달리하여 음질을 향상시킬 수 있었다. 이와 같이 부호화할 경우 약 15 : 1 ~ 20 :1로 원음을 압축하여도 지각적으로 원음과 동일한 복원음을 얻을 수 있었다.

  • PDF

Sensory substitution in perceiving architectural surfaces

  • Kim, Young-Kil;Young, Rockefeller-S.L.
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1992.04b
    • /
    • pp.573-580
    • /
    • 1992
  • 인공건물의 평면특성에 대한 시각을 통한 인지를 청각으로 대체했을 경우의 인지능력을 측정하였다. 정상적으로 시각(visual)을 이용하겠으나, 시각 장애자의 경우는 청각(auditory) 또는 촉각(tactile) 또는 두가지 모두를 사용하게 된다. Psychophysical approach를 사용하여 모의평면에 대한 인지능력을 JND단위로 측정하였다. 청각적인 신호를 관찰자에게 제공하기 위해 전자장치(electronic ranging device)가 고안되었다. 이 장치는 목표물까지의 거리를 초음파의 이동시간으로 측정하여 음의세기(sound level)로 발생시켜 준다. 관찰자는 이 음의 세기를 듣고 거리를 추정하고 물표의 방향은 이 장비를 쥔 손의 방향, 즉, proprioceptive cue를 이용하게 된다. 세가지 task에 대한 실험은 평면의 slantness, 두 평면이 교차하는 모서리의 크기, 두 평면사이의 공간(aperture size)등에 대한 인지능력의 측정실험이다. 실험결과를 보면, 관찰자는 시각신호 대신에 청각신호를 사용할 수 있는 능력이 있는 것으로 나타났다. 세가지 task별 JND측정치는 slant angle 6도, 모서리의 concavity 10도, angular aperature size 3-5도로 나타났다. 이 결과는 정상인이 시각을 이용한 인지능력과 큰 차이가 없음을 보여주고 있다.

  • PDF

An Objective Estimation for Simulating of Asymmetrical Auditory Filter of the Hearing Impaired According to Hearing Loss Degree (난청인의 난청 정도에 따른 비대칭 청각 필터 구현의 객관적 평가)

  • Joo, S.I.;Jeon, Y.Y.;Song, Y.R.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.3 no.1
    • /
    • pp.27-34
    • /
    • 2009
  • Hearing impaired person's hearing loss has personally various shape, so existing symmetrical auditory filter of frequency band method wasn't properly simulated the hearing impaired person's various hearing loss shape. The shapes of auditory filter are asymmetrical different with each center frequency and each input level. Hearing impaired person which has hearing loss was differently changed with that of normal hearing people and it has different value for speech of quality through auditory filter. In this study, the asymmetrical auditory filter was simulated and then some tests to estimate the filter's performance objectively were performed. The experiment as simulated auditory filter's performance evaluation method used perceptual evaluation of speech quality (PESQ) and log likelihood ratio (LLR) for speech through auditory filter. In the test, processed speech was evaluated objective speech quality and distortion using PESQ and LLR value. When hearing loss processed, PESQ and LLR value have big difference between symmetrical and asymmetrical auditory filter. It means that the difference of the shape auditory filter may affect to speech quality. Especially, when hearing loss existed, auditory filter changing according to asymmetrical shape for each center frequency affected to perceive speech quality of the hearing impaired.

  • PDF