• 제목/요약/키워드: 첫뇨

검색결과 2건 처리시간 0.017초

여성에서 소변채집방법에 따른 소변검체의 오염율 비교 (Comparison of the Bacterial Contamination Rates according to the Urine Collection Methods in Women)

  • 정인숙;양만길;오향순
    • 기본간호학회지
    • /
    • 제6권3호
    • /
    • pp.359-368
    • /
    • 1999
  • Background : The purpose of this study was to determine whether cleansing the perineum and urethral meatus and using midstream urine affect the rate of bacterial contamination of urine specimens, and to determine the optimum urine collection method. We studied 41 asymptomatic healthy nursing school students. Women who were menstruating were not excluded from this study. Method : The first and midstream urine samples were collected during consecutive urinationsby each woman. The first sample was not a clean-catch specimen, and the second one was a clean-catch specimen. Both specimens were studied by urinalysis and bacterial culture with standard methods. Results : 41 women met the study criteria and 39 successfully completed the study. None of the urine cultures were positive. 68.3% of the non clean-catch first urine cultures, 53.7% of the non clean-catch midstream cultures, 33.3% of the first clean-catch urine culteres and 30.8% of the midstream clean-catch urine were found to be contaminated. There was a significant difference in the bacterial contamination rates between the first and midstream urine, and the clean-catch and non clean-catch urine(p=0.035, p =0.001 respectively). On urinalysis, 7.3% of the non clean-catch first urine, 7.3% of the non clean-catch midstream urine, 2.6% of the clean-catch first urine and 2.6% of clean-catch midstream urine were found to be above grade 2. Conclusions : According to our results, the bacterial contamination rate was the lowest in midstream and clean catch urine specimens. Threrfore it is recommended that the midstream clean-catch technique is the standard practice for collecting urine specimens for bacterial culture in women.

  • PDF

개심술을 받은 환자의 체위에 따른 심박출량 및 불편감에 관한 연구 (Effects of changing position on cardiac output & on patient's discomforts after cardiac surgery)

  • 유미;권은옥;최윤경;강현주;오세은
    • 기본간호학회지
    • /
    • 제7권2호
    • /
    • pp.256-270
    • /
    • 2000
  • Invasive hemodynamic monitoring has become a valuable assessment parameters in critical care nursing in patients undergoing open heart surgery patients. During cardiac surgery, the Swan Ganz catheter is placed in the pulmonary artery. Critical care nurses routinely obtain cardiac output, cardiac index, and pulmonary arterial pressure in these patients. Traditionally, patients are positioned flat and supine for cardiac output measurement. Numerous studies have dealt with the effects of changing position on the hemodynamic variables. However, there are a few studies dealing with patients who undergo cardiac surgery in Korea. Thus, the purpose of this study was to determine the effects of changing position on cardiac output, PAP, CVP, BP, HR and discomfort in patients after cardiac surgery. A sample of 21 adults who had CABG and/or valve replacement with Swan Ganz catheters in place was studied. The data were collected in the cardiac ICU of a university hospital in Seoul during the period from July 28, 1999 to August 30. 1999. In this study, the independent variable is patient position in the supine, 30 degree, and 45 degree angles. Dependent variables are C.O., C.I., CVP, PAP, MAP, HR and patients' perceived discomforts. Subject discomfort was measured subjectively by visual analogue scale. Other hemodynamic data where collected by the thermodilution method and by direct measurement. The data were analyzed by percentile, t-test, ANOVA, Linear regression analysis using SPSS-/WIN program. The results are as follows : 1) Changes in cardiac output were absent in different angle positions, 0, 30. 45 degrees(F=.070, P=.932). Changes in cardiac index were absent in different angle positions, 0. 30, 45 degrees(P>.05). 2) Changes in central venous pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 3) PAP had no change in different angle 0, 30, 45 degree positions; systolic PAP(P>.05), diastolic PAP(P>.05). 4) Changes in systolic blood pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 5) Changes in heart rates were absent in different angle positions, 0, 30, 45 degree(P>.05). 6) Patients' perceived discomfort was absent in different angle positions, 0, 30, 45 degree(p<.05). In conclusion, critical care nurses can measure C.O., C.I., PAP, BP, & CVP in cardiac surgery patients at 30 degree or 45 degree positions. This can improve the patients' comfort.

  • PDF