• Title/Summary/Keyword: 첨두부하

Search Result 88, Processing Time 0.026 seconds

Estimation of Flow Loads for Landcover Using HyGIS-SWAT (HyGIS-SWAT을 이용한 토지피복도에 따른 유출부하 평가)

  • Kim, Joo-Hun;Kim, Kyung-Tak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.2
    • /
    • pp.28-39
    • /
    • 2011
  • This study estimates the characteristics of flow loads by classification items of the Ministry of Environment and by land cover change using HyGIS-SWAT. The result of analyzing the land cover change using the classification items shows that the urban area and the farmland area in Mishim-cheon and Gap-cheon are expanding while the forest area is decreasing. The result of analyzing the characteristics of classification items shows that peak discharge increases and total yearly discharge decreases in Mushim-cheon. The result of analyzing the characteristics by data-construction period shows that peak discharge decreases but total discharge increases in Gap-cheon. Three land cover change scenarios are applicable to the expansion of urban area and farmland area. According to the result of application, urbanization influences and Farmland area expansion influences increase peak discharge, total yearly discharge and sediment concentration.

ILLUDAS-NPS Model for Water Quality in Urban drainage (도시유역의 수질해석을 위한 ILLUDAS-NPS 모형)

  • Kim Tae-Hwa;Lee Jong-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.482-486
    • /
    • 2005
  • 불투수지역의 증가에 따른 도시지역의 비점오염원 해석 및 예측은 수자원 관리측면에서 중요성이 증가하고 있다. 그러나, 실측자료의 부족, 오염물질 발생경로의 불명확, 간헐성, 강우 및 유역특성에 따라 오염부하량 및 첨두농도 등의 변화가 심하므로 인하여 연구에 어려움이 많은 실정이다. 이를 극복하기 위해서는 장기적인 자료수집과 국내실정에 맞는 모형개발이 이루어져야 할 것이다. 따라서, 본 연구에서는 초기강우에 의한 수질항목별 오염부하량 및 농도계산이 가능한 ILLUDAS-NPS 모형을 개발하였다. 본 모형은 국내의 도시지역 유출해석에 주로 사용되는 ILLUDAS 모형에 건기 및 우기시의 수질해석 과정들을 추가하여 해석되어 진다. 건기시의 경우 유량 및 수질 계산은 계수지정법을 사용하였으며, 우기시의 경우 유량계산은 기존 ILLUDAS 모형의 알고리즘을 이용하였고, 수질 계산은 일일 오염물 축적법과 쓸림방정식을 적용하여 계산시간별 오염물질 부하량 및 농도 등을 계산하였다. 모형의 검정을 위하여 홍제천 시험유역의 총 3가지 강우사상을 대상으로 검토한 결과 총부하량, 첨두농도, 첨두농도 발생시간 등에서 전반적으로 실측치와 유사한 결과를 얻을 수 있었다. 또한, ILLUDAS-NPS 모형과 SWMM, STORM 등의 기존 도시유출$\cdot$수질 모형들에 의한 결과들의 비교에서 SWMM 모형과 다소의 차이는 있으나 대부분 잘 일치함을 확인할 수 있었다. 추후, 합리적이고 보다 정확한 비점오염 해석을 위하여 도시지역의 건거시 오염물질의 축적율 및 초기강우에 의한 오염물질 쓸림량 등에 관한 실험 및 현장자료 축적이 필요하다.월이 긴 것으로 나타났다. 이러한 현상은 유입수가 저수지로 유입되면서 초기수위가 높은 경우에 운동량이 상대적으로 많이 소멸되기 때문으로 판단된다. 또한 탁수층의 두께도 8월 성층의 경우가 상대적으로 큰 것으로 나타났다. 이는 중층의 8월 수온분포 또는 밀도분포가 상대적으로 균일하기 때문에 연직방향 이송$\cdot$확산이 많이 이루어졌기 때문으로 판단된다.이는 토성간의 침투속도 및 투수속도의 경향이 반영된 것이다. 경사에 따라서는 경사도가 증가할수록 지수적으로 감소하였으며 $10\% 경사일 때를 기준으로 $I(mm)=I_{10}{\times}1.17{\times}e^{-0.0164s(\%)}$로 나타났다. 같은 조건에서 강우량과 유거수의 관계는 $Ro_{10}(mm)=5.32e^{0.11R(mm)}(r^2=0.69)$로 나타났다. 이는 토양의 투수특성에 따라 강우량 증가에 비례하여 점증하는 침투수와 구분되는 현상이었다. 경사와 토양이 같은 조건에서 나지의 경우 역시 $Ro_{B10}(mm)=20.3e^{0.08R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10

  • PDF

스너버 커패시터를 이용한 CCPS용 FB-PS-ZVS DC-DC 컨버터의 IGBT Turn-off 손실에 관한 연구

  • Lee, Yong-Deok;Kim, Sang-Hyeon;Kim, Tae-Hyeong;In, Dong-Seok;Kim, Ju-Hun
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.572-573
    • /
    • 2010
  • 본 논문은 30kW급 CCPS(Capacitor Charging Power Supply)용 FB(Full Bridge)-PS(Phase Shift)- Zero Voltage Switching(ZVS) DC/DC Converter의 스위칭 손실저감을 위한 스너버 커패시터의 설계에 대해 논하였다. FB-PS-ZVS DC-DC 컨버터의 하드스위칭 손실과 스너버 커패시터에 의한 스위칭 손실 저감 효과를 비교했다. 첨두 전류를 이용하여 스너버 커패시터를 설계하였으며, 부하 실험을 통해 설계의 타당성을 실험적으로 검증했다.

  • PDF

The development of Power Control System using Linux Controller (리눅스제어기를 이용한 가정용 전력제어시스템의 개발)

  • Woo, Chun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.43-46
    • /
    • 2001
  • 본 연구에서는 인터넷을 이용하여 원격으로 사용전력량을 검침하며, 여름철 첨두 부하시 부족한 전력량을 효율적으로 운영하는 시스템을 개발한다. 특히 세대수가 밀집되어 최대수요전력 제어 효과가 높은 아파트를 우선적으로 제어 대상 지역으로 선정하며, 이에 맞는 구조로 저렴하고 동작이 확실한 시스템을 구성한다. 대개의 아파트는 자체 망이 구성되어 있으므로 인터넷 통신망에 접속하기 쉬우며 또한 신규 설치 시에도 저렴하게 시공할 수 있는 환경을 제공한다. 또한 본 연구에서 POST를 구성하는 산업용 임베디드 리눅스는 기존의 제어기를 구성하던 임베디드 시스템에 실시간 운영체제인 리눅스를 실장시켜 사용한다.

  • PDF

A BOD Simulation by Improved Hydrology and Water Quality Module in SWAT (SWAT 모형의 수문.수질 모듈 개선에 의한 BOD 모의)

  • Kim, Nam-Won;Shin, Ah-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.2068-2072
    • /
    • 2009
  • 본 연구에서는 국내에서 널리 사용되는 대표적 유역모형인 SWAT 모형의 한계를 인식하고 유출해석모듈과 하도수질모듈을 개선한 SWAT-K(Korea) 모형이 현재 오염총량관리 대상물질로 지정되어 있는 BOD 모의에 미치는 영향을 분석하기 위하여 충주댐유역을 대상으로 각 개선모듈별 BOD 모의 결과를 분석하였다. 유출해석모듈의 개선결과 하도의 흐름을 따라 이동하는 BOD 항목의 모의 특성 상 유출 구조의 개선에 의하여 BOD 부하량의 지체가 감소되며 첨두 부하량이 증가한 것을 확인할 수 있었다. 하도수질모듈의 개선결과 저유량 시 매개변수 산정에도 불구하고 증가하지 않던 값들이 모형의 개선에 의하여 정상적인 범위로 상승한 것을 확인할 수 있었다. 전체적인 개선에 의하여 각 모듈별 개선효과와 함께 충주댐 지점의 개선 전 후 일대일 비교를 수행한 결과 결정 계수($R^2$)가 0.54에서 0.88로 상승하며 개선 후 모의값이 실측값에 근사하게 모의되는 것을 확인할 수 있었다.

  • PDF

A Novel Battery Charger/Discharger For the Parallel Connected Battery Module Satellite Power System (인공위성 병렬 연결 배터리 모듈 시스템을 위한 새로운 배터리 충.방전기)

  • 이기선;조윤제;장기영;조보형
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.537-543
    • /
    • 2000
  • A novel integrated battery charger/discharger converter for a standardized battery module is proposed. Instead of using separate charger and discharger converters, it integrates these two converters into a single converter in order to minimize the size. The integrated charger/discharger converter not only regulates the solar array output power including the peak power tracking capability but also controls the battery charging/discharging current depending on the solar array output power and the load power. In addition, it offers a regulated bus voltage which simplifies the power distribution/conversion for the pay load.

  • PDF

ILLUDAS-NPS Model for Runoff and Water Quality Analysis in Urban Drainage (도시유역의 유출·수질해석을 위한 ILLUDAS-NPS 모형)

  • Kim, Tae-Hwa;Lee, Jong-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.9 s.158
    • /
    • pp.791-800
    • /
    • 2005
  • An ILLUDAS-NPS model was developed which is able to compute pollutant loadings and the concentrations of water quality constituents. This model is based on the existing ILLUDAS model, and added for use in the water quality analysis process during dry and rainy periods. For dry period, the specifications of coefficients for discharge and water quality were used. During rainfall, we used the daily pollutant accumulation method and the washoff equation for computing water quality each time. According to the results of verification, the ILLUDAS-NPS model provides generally similar outputs with the measured data on total loadings, peak concentration and time of peak concentration for three rainfall events in the Hong-je Basin. In comparison with the SWMM and STORM models, it was shown that there is little difference between ILLUDAS-NPS and SWMM.

Evaluation of IGCC Plant with Load Factor of Plant (플랜트 부하률에 따른 IGCC 플랜트 복합발전시스템 평가)

  • Jung, Su-Yong;Shim, Hyun-Min;Wang, Hong-Yue;Kim, Hyung-Taek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.816-819
    • /
    • 2007
  • 국내에서 IGCC 플랜트의 복합발전시스템의 평가는 여러 분야별로 진행되어 왔다. 크게 살펴보면 다음과 같다. 첫 번째는 가스터빈 쪽의 기술이다. 즉, 기존 천연가스를 이용하는 가스터빈을 어떻게 하면 석탄가스를 사용하는 IGCC 플랜트에 적합하게 맞출 것인가 하는 문제이다. 두 번째는 효율을 어떻게 하면 높일 수 있는가의 문제로서 석탄의 종류, 가스화 방법을 효율적으로 선택, HRSG(heat recovery steam generator)를 효율적으로 설계, 그리고 정제공정에서의 에너지 소비를 줄이는 분야였다. 세 번째는 어떻게 하면 오염을 줄일까의 문제로서 질소나 스팀 분사를 연계하여 NOx를 감소시키고 정제 공정에 사용되는 촉매를 개발한다던지 공정을 발달시키는 분야였다. 이 외에도 여러 종류의 연구가 이 분야에서 있었으나 주로 설계 분야의 연구가 주되였다. 이것은 발전소의 건설을 위한 초기 단계로서 당연한 결과일 수 있다. 그러나, 지금 IGCC 플랜트가 건설되는 과정에 있으므로 우리나라 전력계통 연계와의 문제도 생각해보아야 한다고 생각한다. 따라서 이번 연구에서는 IGCC 플랜트 운영의 불확실성이 약간이라도 존재하기에 이 플랜트가 기저발전 보다는 첨두발전 쪽이나 태양열/광발전, 풍력발전 등 다른 신재생에너지 자원처럼 독립된 전력 시스템으로 운영될 것이라 생각하고 이렇게 운영될 때는 발전소의 부하률의 변화가 심할 수 있다는 가정하에 플랜트의 부하률에 따른 석탄의 합성가스, 연료가스 전환량 및 전환효율 및 발전량 및 발전효율을 전산모사를 통해 예측해보았다.

  • PDF

A Consideration on the Superconductivity Energy Storage Technology (초전도 에너지 저장 기술에 대한 고찰)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.6
    • /
    • pp.691-698
    • /
    • 2015
  • Recently, the power industry has a great interest in the superconducting energy storage device as a way to maximize energy efficiency to cope with global warming. A superconducting energy storage device can archive maximization of electric energy use efficiency by storing in the form of a magnetic field energy or a kinetic energy without loss a large amount of electrical energy at the non-peak load and then converting it again into electric energy at the peak load. Therefore, in this study, such as the concept of the superconducting energy storage technologies, the present state of its research and development and its applications are surveyed and analyzed to establish methodology applying the superconducting energy storage technologies to power system.

In-Situ Measurement of Chiller Performance and Thermal Storage Density of an Ice Thermal Storage System (빙축열 시스템 냉동기 성능 및 축열밀도 현장측정 기법연구)

  • Shin Younggy;Yang Hooncheul;Tae Choon-Seob;Cho Soo;Kim Youngil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1204-1209
    • /
    • 2005
  • In-situ measurement was made to evaluate chiller performance and thermal storage density of an ice thermal storage system. The system belonged to a big hotel and the measurement was conducted during late October. Owing to very small cooling load, the data logging was possible for a single thermal storage cycle. However, operation history of the chiller showed a relatively good spectrum of data for performance evaluation. COP and thermal storage density were calculated. The COP at full load was about 4.07, which was lower than $4.8\~6.4$ of new chillers. The measured storage density was about $10.9RT-h/m^3\;(=152MJ/m^3)$, which also was lower than a criterion of normal performance $(above\;13.0RT-h/m^3\;or\;181MJ/m^3)$. The study result provides technical basis for quantitative ESCO business scenario.