• 제목/요약/키워드: 첨단의료기기

검색결과 66건 처리시간 0.023초

2단 절개 형태를 가지는 악교정 수술 장치 연구 (A Study of Orthognathic Surgical Guides with Two-stage Split Path)

  • 김민욱;박충환;노지형;정의성;박영상;김동국;서요한;우영재;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.382-389
    • /
    • 2022
  • In this study, the accuracy of the orthognathic surgical guides with single-stage split path was upgraded to realize orthognathic surgical guides with two-stage split path and simulated surgery was performed to verify its accuracy. As a result, the average error distance between the simulation model and the scan model was + 0.289 / - 0.468 mm (standard deviation 0.128), which was confirmed to be within ± 0.5 mm, which is a clinically acceptable level. Also, there was no significant difference compared with the average value of + 0.313 / - 0.456 mm (average standard deviation 0.106) of the conventional single-stage split path type device. It is judged that the use of this device can contribute to the reduction of surgical time and increase in accuracy since a separate finishing operation for bone preparation is unnecessary.

Parylene-C 코팅된 의료용 SUS304 소재의 결합력 향상을 위한 플라즈마 처리 효과 (The effect of plasma treatment to improve adhesion strength of parylene-C coated medical grade SUS304)

  • 김동국;송태하;정용훈;강관수;윤덕규;김민욱;우영재;서요한;김경아;노지형
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.390-397
    • /
    • 2022
  • Parylene-C which was mainly used for industries such as electronics, machinery and semiconductors has recently been in the spotlight in the medical field due to its properties such as corrosion resistance and biocompatibility. In this study we intend to derive a plan to improve the bonding strength of Parylene-C coating with the SUS304 base material for medical use which can be applied to various medical fields such as needles, micro needles and in vitro diagnostic device sensors. Through plasma pretreatment the bonding strength between Parylene-C and metal materials was improved. It was confirmed that the coated surface was hydrophobic by measuring the contact angle and the improvement of the surface roughness of the sample manufactured through CNC machining was confirmed by measuring the surface roughness with SEM. Through the above results, it is thought that it will be effective in increasing usability and reducing pain in patients by minimizing friction when inserting medical devices and in contact with skin. In addition it can be applied to various application fields such as human implantable stents and catheters, and is expected to improve the performance and lifespan of medical parts.

MRI 영상 유도 수술 로봇을 위한 개선된 군집 분석 방법을 이용한 뇌종양 영역 검출 개발 (Development of Brain Tumor Detection using Improved Clustering Method on MRI-compatible Robotic Assisted Surgery)

  • 김대관;차경래;승성민;정세미;최종균;노지형;박충환;송태하
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권3호
    • /
    • pp.105-115
    • /
    • 2019
  • Brain tumor surgery may be difficult, but it is also incredibly important. The technological improvements for traditional brain tumor surgeries have always been a focus to improve the precision of surgery and release the potential of the technology in this important area of the body. The need for precision during brain tumor surgery has led to an increase in Robotic-assisted surgeries (RAS). One of the challenges to the widespread acceptance of RAS in the neurosurgery is to recognize invisible tumor accurately. Therefore, it is important to detect brain tumor size and location because surgeon tries to remove as much tumor as possible. In this paper, we proposed brain tumor detection procedures for MRI (Magnetic Resonance Imaging) system. A method of automatic brain tumor detection is needed to accurately target the location of the lesion during brain tumor surgery and to report the location and size of the lesion. In the qualitative assessment, the proposed method showed better results than those obtained with other brain tumor detection methods. Comparisons among all assessment criteria indicated that the proposed method was significantly superior to the threshold method with respect to all assessment criteria. The proposed method was effective for detecting brain tumor.

CRISPR/Cas 진단의 원리와 현황 (The Principle and Trends of CRISPR/Cas Diagnosis)

  • 박지웅;강봉근;신화희;신준근
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권3호
    • /
    • pp.125-142
    • /
    • 2021
  • The POCT (point-of-care test) sensing that has been a fast-developing field is expected to be a next generation technology in health care. The POCT sensors for the detection of proteins, small molecules and especially nucleic acids have lately attracted considerable attention. According to the World Health Organization (WHO), the POCT methods are required to follow the ASSURED guidelines (Affordable, Sensitive, Specific, User- friendly, Robust and rapid, Equipment-free, Deliverable to all people who need the test). Recently, several CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats) based diagnostic techniques using the sensitive gene recognition function of CRISPR have been reported. CRISPR/Cas (Cas, CRISPR associated protein) systems based detection technology is the most innovative gene analysis technology that is following the ASSURED guidelines. It is being re-emerged as a powerful diagnostic tool that can detect nucleic acids due to its characteristics that enable rapid, sensitive and specific analyses of nucleic acid. The first CRISPR-based diagnosis begins with the discovery of the additional function of Cas13a. The enzymatic cleavage occurs when the conjugate of Cas protein and CRISPR RNA (crRNA) detect a specific complementary sequence of the target sequence. Enzymatic cleavage occurs on not only the target sequence, but also all surrounding non-target single-stranded RNAs. This discovery was immediately utilized as a biosensor, and numerous sensor studies using CRISPR have been reported since then. In this review, the concept of CRISPR, the characteristics of the Cas protein required for CRISPR diagnosis, the current research trends of CRISPR diagnostic technology, and some aspects to be improved in the future are covered.

골이식재의 표면 특성 연구 동향과 유효성 분석 ( Research trends and Efficacy Analysis of Surface Characteristics of Bone Grafts)

  • 정용훈;이계욱;정태곤
    • 한국표면공학회지
    • /
    • 제57권4호
    • /
    • pp.234-253
    • /
    • 2024
  • As the population ages, the importance of effective bone disease treatments is increasing, highlighting the role of bone grafts. Bone grafts are categorized into natural (autografts, allografts, xenografts) and synthetic (ceramics, polymers). Natural grafts have excellent regenerative abilities but pose biological risks, while synthetic grafts are biocompatible but less effective in regeneration. Various studies aim to enhance the safety and efficacy of bone grafts, significantly altering their surface properties. This review examines these studies and the resulting surface changes, aiming to guide future research and clinical applications.

저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향 (The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy)

  • 박영상;손병진;손재범;이호열;정유수;송찬호;정의성
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권6호
    • /
    • pp.259-267
    • /
    • 2021
  • Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.

TiN 및 DLC 코팅된 척추경나사못시스템 수술기구의 기계적 안정성 분석 (Mechanical Stability of TiN and DLC Coated Instrument of Pedicle Screw System)

  • 강관수;정태곤;양재웅;우수헌;박태현;정용훈
    • 한국표면공학회지
    • /
    • 제52권3호
    • /
    • pp.163-170
    • /
    • 2019
  • Durability of instrument is one of the most important factor to ensure accurate treatment and decrease failure for the orthopedic surgical operation. Normally, a set-screw driver tip has been processed with hard coating for their higher durability and wear resistance. And several surface modification methods were obtained such as titanium nitride (TiN) coating, diamond like carbon coating, other nitriding, and etc. In this study, we have surface modified on set-screw driver tip with TiN and DLC, investigated whether the TiN and DLC coatings affect the mechanical properties and durability of the set-screw driver tip in the pedicle screw system. The surface morphologies were observed with scanning-electron microscopy (SEM), and the static/dynamic torsional properties were investigated with universal testing machine based on ASTM F543. Coating thickness of each coatings were commonly around $1^{\circ}C$. Static torsional stiffness, and ultimate torque values for DLC and TiN coated samples were significantly higher than those of non-coated sample by the pared T-test. Surface morphology of after the dynamic torsional test was more clean with less scratch or friction traces from DLC coating than that of TiN coating and non-coated sample.

유방암 동물모델에서의 저강도 집속초음파를 이용한 마이크로버블 및 마이크로버블-나노물질 복합체 기반 항암제 전달 효율 검증 (Effects of Anticancer Drug Delivery based on Microbubble and Microbubble-Nanoparticle Complex using Low-Intensity Focused Ultrasound in Breast Cancer Animal Model)

  • 백희규;하신우;허형규;정병진;한문;문형원;김상균;이학종;박주영
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권2호
    • /
    • pp.39-47
    • /
    • 2019
  • Ultrasound sonication along with microbubble (MB) could enhance drug delivery to promote the absorption of anticancer drugs into cancers in a noninvasive and targeted manners. In this study, we verify the acute drug delivery enhancement (within an hour) of two representative focused ultrasound driven drug delivery enhancement methods (MB and Doxorubicin-coated Nanoparticle complex (MB-NP) based). Experiments were conducted using in vivo mouse model with MDA-MB-231 breast cancer cell line. Ultrasound generated by single-element 1 MHz focused ultrasound transducer was delivered in pulsed sonication consisted of 0.125 msec bursts at a pulse repetition frequency of 2 Hz for 20 seconds without a significant increase in local temperature (less than $0.1^{\circ}C$) or hemorrhage. Doxorubicin concentrations in tumors were improved by 1.97 times in the case of MB-NP, and 1.98 times by using Doxorubicin and MB separately. These results indicate anticancer drug delivery based on MB and MB-NP can significantly improve the effect of anticancer drugs delivered to tumors in a short time period by using low-intensity focused ultrasound.

정책전략 - 첨단의료기기시장 기반 확대

  • 한국전자정보통신산업진흥회
    • 전자진흥
    • /
    • 제29권8호
    • /
    • pp.17-22
    • /
    • 2009
  • 첨단의료기기산업과 바이오산업은 유망한 미래 신산업이다. 바이오산업은 건강(Red), 환경(White), 식량(Green) 등 인류 난제 해결에 필요한 기술 및 제품 개발을 통해 고부가가치를 창출하는 미래 신산업인이다. 핵심 장애요인은 최고기술국 대비 핵심원천기술 확보가 미흡하고, 전반적 기술수준이 선진국 대비 60$\sim$70% 수준이다. 기업중심의 R&D 지원이 미흡하고, 고위험-고수익형 사업성격상 장기투자 부담에 따른 민간투자가 미흡하다.

  • PDF