• Title/Summary/Keyword: 철도 역사 시스템

Search Result 89, Processing Time 0.03 seconds

Examination for Structural Safety of Floating Slab Design and Shear Connector (플로팅 슬래브 설계와 전단연결재의 구조안전성 검토)

  • Park, Sung-Jae;Ma, Chang-Nam;Lee, Jong-Ho;Lee, Du-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.374-374
    • /
    • 2011
  • Recently the construction of railway sections passing the central area of cities and stations under railway lines are increasing, and then it is urgently required to take the countermeasures against the railway vibration and the second-phase noise radiated from it. The most efficient countermeasure, out of technologies developed up to now, is the floating slab track which is the track system isolated from the sub-structure by springs. In other countries, the source technologies for anti-vibration design and vibration isolator - one of key components - have been developed and many installation experiences have been accumulated. However, in Korea, since the system design technology and technologies for key components are not yet developed, the foreign system are being introduced without any adjustment, and the key component, vibration isolator, depends on imports. In this study, based on the results of previous studies of the dust-control device installation using the slab and go through time after lifting impressive when stepped on power generated by the cross-section of the slab and shear connection re-examined the structural stability.

  • PDF

A design and implementation of Intelligent object recognition system in urban railway (도시철도내 지능형 객체인식 시스템 구성 및 설계)

  • Park, Ho-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.2
    • /
    • pp.209-214
    • /
    • 2018
  • The subway, which is an urban railway, is the core of public transportation. Urban railways are always exposed to serious problems such as theft, crime and terrorism, as many passengers use them. Especially, due to the nature of urban railway environment, the scope of surveillance is widely dispersed and the range of surveillance target is rapidly increasing. Therefore, it is difficult to perform comprehensive management by passive surveillance like existing CCTV. In this paper, we propose the implementation, design method and object recognition algorithm for intelligent object recognition system in urban railway. The object recognition system that we propose is to analyze the camera images in the history and to recognize the situations where there are objects in the landing area and the waiting area that are not moving for more than a certain time. The proposed algorithm proved its effectiveness by showing detection rate of 100% for Selected area detection, 82% for detection in neglected object, and 94% for motionless object detection, compared with 84.62% object recognition rate using existing Kalman filter.

A Study on the Development of Control System for small unit Electric Power System (소규모 전력계통 제어시스템 개발에 관한 연구)

  • Lee, Seung-Chul;Lee, Youn-Seop;Shin, Kwan-Woo;Lim, Jae-Woong;Kim, Yong-Tae;Byun, Young-Joon;Lee, Joon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2331-2333
    • /
    • 2003
  • 전력계통의 원방감시제어시스템(SCADA)은 원방의 전력계동을 화면에 표시하고 감시하며 필요한 제어명령을 실행하는 시스템을 말한다. 철도청의 기존 전력계통 제어시스템은 UNIX를 기반으로 하여 특별히 교육 받은 운용자만이 감시제어 및 관리할 수 있고 구축비용이 많이 소요되며 지역 사무소에서 운용되기 때문에 원격지의 전력계통 사고의 경우 시스템 운용자는 현장의 근무자와 연락하여 사고의 원인을 파악하고 조치해야 하는 단점이 있다. 또한 새로운 통합 SCADA 시스템이 구축되면서 기존 지역사무소에서 운용하던 전력계통 제어시스템이 없어지고 중요 역사마다 지역사무소의 전력계통 제어시스템을 대체할 수 있는 소규모 전력계통 제어시스템의 설치가 요구되고 있다. 본 논문에서는 기존 UNIX를 기반으로 한 SCADA 시스템의 기능을 모두 수용하고 현장의 근무자들이 쉽게 감시제어 및 유지보수까지도 할 수 있는 경제적인 전력 계통 제어시스템을 개발하고자 한다. 소규모 전력 계통 제어시스템을 개발하기 위해 Cimon 이라는 산업자동화프로그램을 이용하였으며 철도청 철암 역사에 직접 시스템을 설치하여 원격소 장치(RTU)와 새로 추가 설치된 전자식배전반을 동시에 수용할 수 있는 소규모 전력계통 제어시스템을 개발하고 실험하였다.

  • PDF

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

On the Development of Safety Requirements Based on Functional Analysis of LRT Stations in Concept Development Stage (경전철 역사 개념설계 단계에서 기능분석 결과를 활용한 안전요구사항의 생성방법에 관한 연구)

  • Kim, Joo-Uk;Jung, Ho-Jeon;Park, Kee-Jun;Kim, Joorak;Han, Seok Youn;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.382-391
    • /
    • 2016
  • For safety-critical systems including railways, there has been a growing need for effective and systematic safety management processes. The outcomes of efforts in this area are international safety standards, such as IEC 61508, 62278, and ISO 26262. One of the principal activities in the safety process is hazard analysis. For this reason, considerable efforts have been directed toward methods of hazard analysis. On the other hand, the hazard analysis methods reported thus far appear to be unclear in terms of their relationship with the system design process. In addition, in some cases, the methods appear to rely heavily on information regarding the hardware and software components, the number of which is increasing. These aspects can become troublesome when design changes are necessary. To improve the situation, in this paper, hazard analysis was carried out using the result of functional analysis early in the concept development stage for a safety-critical system design. Because hazard analysis is carried out at the system level and the result is then used to develop the safety requirements, improvements can be expected in terms of the development time and cost when design changes are required due to changes in the requirements. As a case study, the generation of safety requirements for the development of light rail transit stations is presented.

A Plan of Existing System Interface within Station (역사내 기존 시스템 인터페이스 방안)

  • Lee, Won-Jae;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1550-1555
    • /
    • 2011
  • This paper presents the system interface standard that are associated with additional devices like sensor nodes as well as fire monitoring panel, panic button and emergency call in city railroad environment. Existing fire monitoring panel, panic button and emergency call system is responsible for fire detection and alarm, emergency alarm and communication with the manager. Recently, researches that are associated with NVR-based intelligent integrated surveillance systems and existing alarm system are activated but most of the system is dedicated to it existing. In order to expand devices that is supported other monitoring function, separate device configuration or modification of integrated surveillance system are inevitable. In this study, interface standard between standard controller, integrated command center and each device that facilitate additional expansion of integrated surveillance system and avoid the extra cost is presented.

  • PDF

A study on present status and improvement of protection relay system in subway station for stable power supply (지하철 역사의 안정적 전원공급을 위한 보호시스템 검토)

  • Na, Jong-Woo;Jo, Won-Kang;Park, Dong-Seon;Yoo, Yeon-Seong;Moon, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

A Load Balancing Control Method Verification Test For Light weigh electric railway Using Wireless Power Transfer System (무선전력전송시스템을 적용한 경량전철의 부하균등제어방법 실증 시험)

  • Kim, Chan-in;Lee, Chan-Gyo;O, Yeong-Seok;Yoo, Hyo-Yol;Cho, Jung-Goo
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.156-157
    • /
    • 2019
  • 경량전철과 같은 대용량 전력 시스템에 무선전력전송 기술을 적용할 때 전력변환장치의 병렬 운전은 필수적이다. 병렬 연결된 전력변환장치의 경우 출력이 공통으로 연결되어 전력을 공급하게 되는데, 이 때 집전 컨버터의 부하균등제어는 각각의 집전 컨버터의 부하 불균형을 막아줌으로써 집전 컨버터의 수명과 효율이 감소하는 것을 막아준다. 본 논문에서는 부하균등제어방법을 적용한 무선 경량전철 시스템을 통해 기존에 제안된 제어기법을 적용하여 검증하였다. 실증시험의 경우 경산에 위치한 한국철도기술연구원 경량전철시험선의 시험용 경량전철을 두 개의 역사를 반복하여 셔틀 운행하여 최대 400kW의 전력을 두 개의 집전 장치가 전력을 균등하게 공급하는 것을 확인 및 분석하여 논문의 타당성을 검증하였다.

  • PDF

A Study on the Effective application scheme of Subway optical communication system (지하철 광통신 시스템의 효율적 운용방안에 대한 고찰)

  • Kwon, Gi-Jung;Lee, Gi-Seung;Ko, Young-Yun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1541-1550
    • /
    • 2007
  • A subway is one of many public transportation means that contributes toward our society including seoul and offering of its service and expression of various information are in need due to users high demand. And there are various class of users. For that reason an optical communication network in the general contorl center and station buildings was installed. Considering the importance of safe operation of subway, optical communication exists to enhance customer satisfaction. Safe operation is essential as its level of reliance accounts for about 95%. this paper will look for ways to promote mutual information interchange and operation know-how with systems of the same kind and sharing a capable of effective operation of systems in place. Optical communication network in the metropolis railroad accepts various kinds of control networks and data networks for train operation. As occasion demands, this paper presents effective application scheme and specialized organization about an optical communication operating system.

  • PDF

The Improvement of the Area Estimation of the Metropolitan Railway Station Platforms (도시철도 및 광역철도 승강장 면적산정식의 개선방안 연구)

  • Kim, Jinho;Shin, Minjung;You, Soyoung;Kim, Taewan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.991-999
    • /
    • 2018
  • In urban areas, the proportion of railway traffic in public transport is increasing. The congestion situation is repeated as the passengers concentrate on station and transfer facilities and the inconvenience of the passengers is increasing in terms of safety and convenience. Therefore, the importance of estimating the appropriate area of the station has been emphasized. The area estimation formula used in the metropolitan railway stations currently is a partial modification of the area estimation formula of Japan in the 1970s. It does not reflect changes in the social and cultural environment and patterns of passengers. The technical basis for major decision variables is insufficient. Therefore, the theoretical basis of the area estimation formula and the pedestrian environment satisfaction of the design guideline of metropolitan railway stations were analyzed in order to suggest improvement formula. The improved area estimation formula was verified by conducting field surveys on 5 stations of metropolitan railways and 15 stations of urban railways. The existing area estimation formula is LOS E grade for the main space. However, the LOS D grade is implemented when the improved area estimation formula is applied. Based on the results, the design factors for the area estimation formula are suggested.