• Title/Summary/Keyword: 철근 겹침이음

Search Result 91, Processing Time 0.027 seconds

Evaluation of Damage Index for Reinforced Concrete Column according to Lap-splice, Number of Cycle, Axial Load and Confinement steel Ratio (철근콘크리트 교각의 겹침이음, 하중재하 횟수, 축하중비 및 구속철근비에 따른 손상도 평가)

  • 이대형;정영수;박창규
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.271-279
    • /
    • 2003
  • The objective of this study is to evaluate the damage of the reinforced concrete bridge piers. For the purpose of this research, twelve reinforced concrete specimens were fabricated and experimented with quasi-static test method. The selected test parameters are lap splice, axial load ratio, confinement steel ratio and number of loading cycle. The method of evaluate of damage index is the model proposed by Park and Ang. In accordance with this research, the most effective test parameter is lap splice of longitudinal steel. Therefore, the retrofit scheme of reinforced concrete bridge piers with lap splice of longitudinal steel, which was constructed before 1992, must be settled without delay. Otherwise, the effect of axial force is trivial. The more confinement steel is less damage index and more loading cycle lead to raise damage. The damage statement proposed Park and Ang is the same with experimental results.

  • PDF

Experimental Study on the Precast Concrete Joint using Re-bar Debonding and Cutting Technique (철근 비부착 및 절단 기법을 사용한 PC 접합부의 실험적 연구)

  • Yi, Waon-Ho;Moon, Jung-Ho;Lee, Yong-Jae;Lee, Han-Jun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.4 s.7
    • /
    • pp.131-141
    • /
    • 2002
  • Precast concrete (PC) panels are often used as retaining walls to support soil pressure. In such a case, the panels should be connected at the location where PC panels meet with a buttress. However, it is not easy to provide enough development length for the reinforcing steels due to the limited width of the buttress. If it happens, the width of buttress should be increased as large enough although it is not desirable. The critical section required for providing the development length is always located where the flexural moment is maximum. Thus it is the place the buttress width ends. Also it is the place that the reinforcing steels stressed to maximum. However, it is possible to make differentiate between the maximum moment location and the most stressed location of reinforcing steels. It means that the most stressed location of reinforcing steels, the critical section, can be moved to the other place where the moment is not maximum. New critical location will have less moment than that of buttress width ends. In consequence, the development length would be longer than that of the typical way of construction. Debonding or cutting technique make it possible to reduce the moment strength of a section. Therefore reinforcing steels are debonded or cut to have a desired flexural strength at a desired place. In this study, five test specimens in full scale were erected to examine the effects of critical section movement in PC panel joints. Test parameters were the length variations of debonded and cut reinforcing steels. The test results showed that the debonding or cutting technique could be used to lengthen the development length in the joint of PC panels.

Seismic Performance Analysis of RC Piers with Lap-spliced Reinforced Steel and Differentiated Aspect Ratios (주철근 겹침이음 및 형상비에 따른 철근콘크리트 교각의 내진거동 분석)

  • Cho, Chang-Beck;Shin, Ho-Jin;Kwahk, Im-Jong;Chung, Young-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.41-53
    • /
    • 2012
  • The objective of this study is to evaluate the seismic capacity of RC piers with small aspect ratios. Test specimens were selected from the prototype piers among existing national roadway bridges which are expected to fail in shear and/or complex shear-flexural mode. Two groups of full scale RC pier models were constructed with aspect ratios of 2.25 and 2.67. Quasi-static tests have been implemented to investigate the failure behavior of the RC piers in terms of the lap-spliced longitudinal reinforcing steel and the aspect ratio. It is confirmed that regarding its shear-flexural behavior, the pier is very sensitive to the aspect ratio or details. In the case of a test pier with highly lap-spliced longitudinal bars, the bond failure of lap-splice steels was the dominant cause of failure before the occurrence of flexure or shear-flexural failure, despite a slight change in the aspect ratio. Finally, based on the test results and analysis, this paper proposes formulas for the yielding and ultimate displacements of circular reinforced concrete bridge piers without seismic details. These formulas will be useful for the investigation and upgrade of the seismic capacity of bridge piers without seismic details.

Behavior of Reinforcement Ratio on Concrete Beams Reinforced with Lab Spliced GFRP Bar (GFRP 보강근으로 겹이음된 콘크리트 보의 보강비에 따른 거동특성)

  • Choi, Yun Cheul;Park, Keum Sung;Choi, Hyun Ki;Choi, Chang Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.67-76
    • /
    • 2011
  • The use of glass-fiber-reinforced polymer (GFRP) bars in reinforced concrete (RC) structures has emerged as an alternative to traditional RC due to the corrosion of steel in aggressive environments. Although the number of analytical and experimental studies on RC beams with GFRP reinforcement has increased in recent decades, it is still lower than the number of such studies related to steel RC structures. This paper presents the experimental moment deflection relations of GFRP reinforced beam which are spliced. Test variables were different reinforcement ratio and cover thickness of GFRP rebars. Seven concrete beams reinforced with steel GFRP re-Bars were tested. All the specimens had a span of 4000mm, provided with 12.7mm nominal diameter steel and GFRP rebars. All test specimens were tested under 2-point loads so that the spliced region be subject to constant moment. The experimental results show that the ultimate moment capacity of beam increasing of the reinforcement ratio. Failure mode of these specimens was sensitively vary according to the reinforcement ratio. The change of beam effective depth, which was caused by cover thickness variation, controlled the maximum strength and deflection because of cover spalling in tension face.

A Study on Out-of-Plane Flexural Behavior of the Structure with a Vertical Plane Connection between a Reinforced Concrete Wall and a Steel Plate Concrete Wall (철근 콘크리트 벽과 강판 콘크리트 벽이 수직으로 만나는 이질접합 구조물의 면외 휨 거동 특성 연구)

  • Hwang, Kyeong Min;Lee, Kyung Jin;Hahm, Kyung Won;Kim, Won Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.93-102
    • /
    • 2013
  • This paper describes the experimental study on the structural behavior of the vertical plane connection between a reinforced concrete wall and a steel plate concrete wall under out-of-plane flexural loads. The specimen was tested under a dynamic test with the use of cyclic loads. As a result of the test, ductile failure mode of vertical bars was shown under a push load and the failure load was more than that of the nominal strength of the specimen. However, the shear failure mode of the connection was confirmed in case of a pull test and thus demonstrates a need for a shear reinforcement.

Effects of Transverse Reinforcement on Headed Bars with Large Diameter at Cut-off Points (컷오프 구간에 정착된 대구경 확대머리철근에 대한 횡보강근의 효과)

  • Jung, Hyung-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.82-90
    • /
    • 2018
  • The nuclear structures are composed of large diameter bars over No.36. If the hooked bars are used for anchorage of large diameter bars, too long length of the tail extension of the hook plus bend create congestion and make an element difficult to construct. To address those problems, headed bars were developed. Provisions of ACI 318-08 specify the development length of headed bars and ignore the effect of transverse reinforcement based on the background researches. However, if headed bars are used at the cut-off or lap splice, longitudinal reinforcements, which are deformed in flexural members, induce tensile stress in cover concrete and increase the tensile force in the transverse reinforcement. The object of this research is to evaluate the effects of transverse reinforcement on the anchorage capacity of headed bar so anchorage test with variable of transverse rebar spacing was conducted. Specimens, which can consider the behavior at the cut-off, were tested. Test results show that failure of specimen without transverse reinforcement was sudden and brittle with concrete cover lifted and developed stress of headed bars was less than half of yield strength of headed bars. On the other hand, in the specimen with transverse reinforcement, transverse rebar directly resist the load of free-end so capacity of specimens highly increased.

An Experimental Study on Bond Strength of High-Strength Reinforcing Bars with High Relative Rib Area (높은 마디면적 고강도 철근의 부착강도에 관한 실험적 연구)

  • Hong Geon-Ho;Choi Dong-Uk;Choi Oan-Chul;Hong Gi-Suop
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.375-384
    • /
    • 2005
  • The effects of bar deformation properties on bond of steel reinforcing bars to concrete are experimentally studied to predict the bond strength. Based on the previous research about high relative rib area, bond strength between reinforcing bars and concrete can be improved by the control of rib height and spacing. But, the equations in Korean code provisions to estimate development and splice length do not include these specifications of reinforcing bars. So the purpose of this paper is to determine the effect of relative rib area to the bond strength. This paper describes 2 kinds of experimental researches. Thirty beam-end specimens were tested to investigate the effects of bar size and relative rib areas ranging from 0.112 to 0.162. And, twelve lap-splice beam specimens were tested to the same variables. Each test results are normalized and compared with the proposed equations of ACI 408 committee. The results show that bond strength is increased as bar size and the relative rib area(Rr) increase. The distribution of flexural cracks and failure aspect do not appear to be affected by $R_r$.

An Experimental Study on the Structural Behavior of Concrete Columns Confined with Welded Reinforcement Grids (용접 띠철근 보강된 콘크리트 기둥의 역학적 거동에 관한 실험적 연구)

  • Choi, Chang-Sik;Saatcioglu, Murat
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.187-196
    • /
    • 1999
  • An experimental investigation was conducted to study the structural behavior of concrete columns confined with welded grids. The full-scale columns with different volumetric ratio, spacing and arrangement of welded reinforcement grids were tested under simulated seismic loading. The columns were subjected to constant axial compression of approximately 20% or 40% of their capacities accompanied by incrementally increasing lateral deformation reversals. The results indicate that the welded reinforcement grid can be used effectively as confinement reinforcement provided that the steel used, have sufficient ductility and the welding process employed does not alter the strength and elongation characteristics of steel. The grids improved the structural performance of columns, which developed lateral drift ratios in excess of 3% with the spacing and volumetric ratio of transverse reinforcement similar to those required by the ACI 318-95 Building Code. Drift capacity further increased when grids with larger number of cells were used. Furthermore, the use of grids reduced congesting of reinforcement while the dimensional accuracy provided perfect support to longitudinal reinforcement.

Bond Strength Evaluation of RC Beams on the Rib Shape of Reinforcing Bars (철근 마디 형상에 따른 RC 휨부재의 부착강도 평가)

  • Hong, Geon-Ho;Kim, Jin-Ah;Choi, Oan-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.393-400
    • /
    • 2011
  • The needs for high strength structural materials have recently increased, because construction and cost efficiencies are demanded by the costumers. But, the use of high strength reinforcing bars requires longer development and splice lengths compared to normal strength bars. This restriction may cause reduction in construction efficiency and require more complicated details. The purpose of this paper is to evaluate the bond strength on the rib shape of reinforcing bars to decrease development and splice lengths of high strength reinforcements. Total of 5 simple beam specimens were tested, and the main test variable was a rib shape of reinforcing bars. Test data was analyzed in the viewpoint of bond strength, load-deflection relationship, and crack pattern. Test results indicated that the bond strength of high relative rib area reinforcing bars increased up to 11% compared to normal strength reinforcements. And the improved rib shape reinforcements, which were formed with high and low height rib, increased the bond strength up to 23% even though the relative rib area was same as the high relative rib area reinforcements. Serviceability performances such as deflection number of cracking, and maximum crack width were similar in all specimens, so it is safe to conclude that the improved rib shape reinforcements can be applied to the structural members.

Experimental Behavior of Reinforced Concrete Column-Bent Piers under Bidirectional Repeated Loading (이축반복하중을 받는 2주형 철근콘크리트 교각의 실험거동)

  • Park, Chang-Kyu;Lee, Beom-Gi;Song, Hee-Won;Chung, Young-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.17-24
    • /
    • 2005
  • Response of reinforced concrete (RC) column-bent piers subjected to bidirectional seismic loadings was experimentally investigated. RC column-bent piers represent one of the most popular shapes of piers used in Korea highway bridges. Four column-bent piers were constructed in 400 mm diameter and 2,000 mm height. Each pier has two circular supporting columns. These piers were tested under bidirectional lateral load reversals with an axial load of $0.1f_{ck}A_g$. The test parameters included : different transverse reinforcement contents and lap-spliced longitudinal reinforcing steels. Test results indicate that the lap splice of longitudinal reinforcing steels have significantly influenced on hysteretic response of column-bent piers similar to previous test results for single columns with corresponding test parameters. Column capacity was changed with the level of transverse confinement. From the comparison of test result for single column under unidirectional loading, the damage of single column was concentrated on lower plastic hinge region but the damage of column-bent piers was scattered to upper and lower plastic hinge region.