• 제목/요약/키워드: 철근콘크리트 기둥

검색결과 611건 처리시간 0.026초

섬유시트로 보강된 철근콘크리트 기둥의 압축강도 특성에 관한 실험적 연구 (An Experimental Study on the Compressive Strength Characteristics of Reinforced Concrete Columns Strengthened with Fiber Sheets)

  • 김정섭;최진석;조철희;고송균
    • 한국건축시공학회지
    • /
    • 제3권2호
    • /
    • pp.119-127
    • /
    • 2003
  • Test specimen test was performed using concrete reinforced with fiber sheet and the test variables were based on the kinds of fiber and the number of reinforcement layers. Using steel-concrete reinforced with fiber sheet, compression tests were performed and the test variables were the kinds of fiber, number reinforcement layers and reinforcement layer order. The following results were obtained: 1) It was demonstrated that compressive strength of the test specimen reinforced during test specimen test and member test increased as the number of reinforcement layers increased. 2) It was shown that non-reinforced test, specimen were destroyed during the member tests, but the specimen reinforced with CFS destroyed and the GFS-reinforced specimen and composite reinforced specimen showed ductile destruction. 3) As a result of tests on kinds of reinforcement fiber, it was demonstrated that CFS-reinforced test specimen had higher compressive strength in a 공시체 test. In the member test, 2ply-and 3ply-GFS reinforced specimens except lplied one had higher compressive strength. It was because partial destruction occurred due to the rate of height/section. 4) For layer strength order, compared with test specimen reinforced only with a single reinforced material, test specimen reinforced with CFS and GFS, and test specimen reinforced with CFS first showed better results in compressive strength and ductility judgement.

외부부착형 BCM공법으로 보강된 철근콘크리트 기둥의 내진보강 (Seismic Retrofitting of Existing Reinforced Concrete Columns Using Binding Column Method)

  • 허무원;박태원;이상현;박현수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권5호
    • /
    • pp.119-126
    • /
    • 2022
  • 본 연구는 내진설계가 되어 있지 않은 필로티 건축물의 부족한 횡력을 보강할 수 있는 외부부착형 내진보강공법(Binding Column Method, BCM)을 제안하였다. 또한, 제안된 내진보강공법을 대상으로 보강실험체 4개, 기준 실험체 1개를 제작하여 반복가력 실험을 통하여 보강 전·후의 내진성능향상 효과를 검토하였다. 실험 결과, 기준 실험체(SC1)는 급격한 강도저하와 함께 취성적인 전단파괴의 양상을 나타낸 반면, BCM 공법을 적용한 실험체(SC2, SC3, SC4, SC5)는 강도 및 강성의 증가와 함께 에너지 흡수 능력이 큰 타원형의 이력특성을 나타내었다. 또한, 간격이 좁고 토크가 크며, L자형 강판의 두께가 두꺼울수록 보강효과가 향상됨을 알 수 있다. BCM공법 중 전단보강간격이 작고, 조임력 값이 크며, 연결철물이 두꺼운 SC4실험체가 가장 뛰어난 내진성능보강 효과를 나타내었다.

비접촉 겹침 이음된 프리캐스트 U형 보의 휨성능에 미치는 효과 (Effect of Flexural Performance on U-Shaped Precast Concrete Beams with Noncontact Lapped Splice)

  • 하상수;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.119-128
    • /
    • 2008
  • 본 연구는 중진지역에서의 PC(precast conctete) 보-기둥 접합부의 새로운 모멘트-저항 시스템을 제안하는 것이다. 철근 이음형 접합부에서 연결재는 접합부를 관통하고, U형 하프 PC 보의 하부철근과 비접촉 겹칩이음으로 연결되어 있다. 비접촉 겹침이음에 대한 성능을 파악하기 위하여 실험적 연구와 해석적 연구가 수행되었다. 실험의 주요변수는 겹침길이, 연결재의 크기, 그리고 겹침이음된 연결재의 거리 등이다. 또한, 균열양상, 하중-변위 곡선, 내력 비교, 그리고 연결재의 변형 등에 초점을 맞추어 해석적 연구를 수행하여 실험결과와 비교하였다. 해석과 실험 결과 주요변수인 겹침길이, 연결재의 크기, 연결재의 비접촉 수직 거리등에 따라 강도, 연성, 그리고 접합부 거동에 큰 영향을 주는 것으로 나타났다.

철골보와 철근콘크리트기둥으로 구성된 내부 접합부의 극한전단강도 산정에 관한 연구 (A Study on the Ultimate Shear Strength Estimation of the Interior Joints of Steel Beam and Reinforced Concrete Column)

  • 문상훈;안재혁;박천석
    • 한국안전학회지
    • /
    • 제21권2호
    • /
    • pp.57-62
    • /
    • 2006
  • Recent trends in the construction of building frame feature the use of composite steel concrete members. One of such system, RCS(Reinforced Concrete column and Steel beam) system, is known as a type of system to maximize the structural and economic benefits in the most efficient manner. This paper is focusing on an study of ultimate shear strength estimation of the interior beam-column joints of RCS system, with reinforced concrete column and steel beam. Current design methods as well as the majority of the previous researches for ultimate shear strength of the interior beam-column joint of RCS system are not easy to apply actual manner. There is a need to propose the rational macro models based on analytical approach. In this study, design method variables for interior beam-column joints of RCS system is studied assuming shear resistance of steel web panel, diagonal concrete strut mechanism and truss mechanism. Finally, calculated results based on the proposed design model are compared with test data.

탄소섬유(炭素纖維)시트로 보강(補强)된 철근(鐵筋)콘크리트 기둥의 강도특성(强度特性)에 관한 연구(硏究) (A Study on the Strength Characteristics of Reinforced Concrete Columns Confined with Carbon Fiber Sheets)

  • 장정수;조성찬;주수석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.163-171
    • /
    • 2001
  • Lateral confinement pressure generate improvements in strength and ductility of confined concrete. Carbon fiber sheets have a lot of merits, such as light weight, high strength and ease for construction, when it is applied to the defected structural member for the strengthening of shear and flexure. The purpose of this experimental study is to evaluate the strength characteristics of the reinforced concrete column confined with carbon fiber sheets. The main variables in this test are concrete strength ($290kgf/cm^2$ called N type, $505kgf/cm^2$ called H type) and pre-loading. In the test, a total of twelve specimens, which were all $10{\times}10cm$ in size, 117 cm in length, have a 2.85 reinforcement ratio, have been used. The results indicate that the strength was enhanced 26%~30% in N type, 11%~16% in H type specimens which was confined with carbon fiber sheets.

  • PDF

교체 가능한 강재 헌치 시스템으로 보강한 철근 콘크리트 보-기둥 구조물의 내진성능에 관한 실험적 연구 (An Experimental Study on Seismic Performance of Reinforced Concrete Beam-Column Retrofitted with Replaceable Steel Haunch System)

  • 김윤성;김민숙;이영학
    • 한국공간구조학회논문집
    • /
    • 제24권1호
    • /
    • pp.81-88
    • /
    • 2024
  • The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.

C형 및 H형 철근콘크리트 구조벽체의 2축 상호작용과 등하중법 (Biaxial Interaction and Load Contour Method for Reinforced Concrete C- and H-shaped Structural Walls)

  • 남혜성;엄태성
    • 콘크리트학회논문집
    • /
    • 제29권2호
    • /
    • pp.189-200
    • /
    • 2017
  • C형 및 H형 단면의 구조벽체는 고층 건물에서 횡력저항시스템으로 널리 이용된다. 이러한 이형벽체는 축력과 함께 x축 및 y축에 대한 2방향 휨모멘트를 동시에 받으므로, 안전한 벽체설계를 위해서는 휨-압축 상호작용을 정확히 고려해야 한다. 이 연구에서는, 대칭단면을 갖는 기둥을 위하여 개발된 기존 등하중법을 수정하여, 2방향으로 재하된 C형 및 H형 벽체를 위한 근사설계방법을 제안하였다. 다양한 단면형상을 갖는 이형벽체에 대하여 2방향 모멘트강도를 계산할 수 있는 단면해석 프로그램을 개발하고, 실험결과와 비교를 통하여 프로그램의 정확성을 검증하였다. 또한 개발한 프로그램을 사용한 변수연구를 통하여, C형 및 H형 이형벽체 단면에 대한 2축 상호작용 특성을 분석하였다. 분석 결과, C형 및 H형 이형벽체의 2축 상호작용은 모멘트 방향과 압축력 크기에 의하여 크게 영향을 받는 것으로 나타났다. 이러한 변수연구를 통하여 일정한 압축력에서 2축 모멘트강도의 상관관계를 나타내는 정규화된 컨투어 설계식을 제안하였다. 또한 실무에서 쉽게 활용할 수 있도록, 제안된 컨투어 설계식을 사용한 이형벽체 설계절차와 설계예제를 제시하였다.

IT 융합기술을 적용한 동바리 붕괴사고 방지를 위한 건설공사 시스템 제안 (Proposal of Construction System to prevent Dongbari Collapse by applying IT Convergence Technology)

  • 전경덕;신승중
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권5호
    • /
    • pp.113-120
    • /
    • 2020
  • 건설공사에 있어 산업재해라고 불리는 안전사고는 사고 발생시에는 많은 인명 피해와 재산상의 피해, 사회적으로도 큰 물의를 일으키고 있어 건설공사의 공신력 저하의 원인이 되고 있다. 최근 들어 초고층, 대심도, 다양한 용도의 복합건축물이 시공이 많아짐에 따라 건설현장의 안전사고의 위험은 계속 증가 될 수 있다. 특히, 철근콘크리트 건축물중 가장 많이 시공되는 아파트 공사는 세대구성 부분은 층별로 보가 없는 벽식 구조로 설계와 시공이 되고 저층부에서는 기둥과 보가 있는 라멘 구조로 되어 있다. 그에 따라 상부 하중을 견디기 위한 전이보 또는 전이 스라브가 라멘구조 상부에 설치되므로, 콘크리트 타설 시공시 가설재로 설치되는 시스템 동바리는 타설작업 및 양생시 붕괴 사고가 언제든 발생될 수 있다. 본 연구의 목적은 IT 융합 기술을 적용하여 콘크리트 타설시 시스템 동바리 붕괴가 발생치 않도록 하는 것을 연구 목적으로 하고 있으며, 시공 중 발생 될 수 있는 많은 변수를 각각의 사례별로 적용하여 시스템 동바리 안정성을 확인 하고 전도방지 예측 시스템의 모델을 제안 하고자 한다.

내진보강용 폴리우레아로 보강된 철근콘크리트 기둥의 내진성능 평가에 대한 유사동적실험 연구 (Pseudo Dynamic Test Study on Seismic Performance Evaluation of RC Columns Retrofitted by PolyUrea)

  • 조철민;이두성;김태균;김장호
    • 대한토목학회논문집
    • /
    • 제37권2호
    • /
    • pp.289-301
    • /
    • 2017
  • 국내외적으로 지진의 발생이 빈번함에 따라 인명 및 재산 피해가 발생하고 추가적인 경제적 손실을 초래한다. 국내의 비내진으로 설계된 구조물의 보수 보강이 시급할 뿐만 아니라 지진에 대한 관심이 고조됨에 따라 내진보강에 대한 연구가 활발히 진행되고 있다. 최근 고연성 보강재를 사용한 내진보강기법이 소개되면서 강성보강보다는 연성보강에 대한 신뢰도가 높아지고 있다. 따라서 본 연구에서는 연성보강 재료로써 최근 각광받고 있는 폴리우레아를 이용한 내진보강공법을 소개하기 위해서, 폴리우레아로 보강한 RC 시편에 대하여 일축압축시험과 유사동적실험을 수행하였다. 일축압축시험에서 폴리우레아 보강시 강도가 증진되었을 뿐 아니라 연성거동을 확인할 수 있었으며, 실제 지진파를 적용한 유사동적실험에서는 상대변위, 주철근의 변형률, 변위연성도, 소산에너지 모두 향상된 보강성능을 확인할 수 있었다. 연성보강의 목적으로 개발한 폴리우레아 보강방법은 기둥부재의 내진보강에 유용하게 사용될 것이라고 판단된다.

박판 냉간성형강 합성보의 구조적 거동에 관한 연구 (A Study on the Structural Behavior of Profiled Composite Beams)

  • 양구록;황영서;송준엽;권영봉
    • 한국강구조학회 논문집
    • /
    • 제11권2호통권39호
    • /
    • pp.143-151
    • /
    • 1999
  • 본 논문에서는 냉간성형 profiled steel sheeting과 보통강도의 콘크리트로 이루어진 합성보의 휨거동에 관한 연구를 통하여 새로운 형식의 보부재의 사용가능성을 검토하였다. 합성보의 비선형거동을 추적하기 위하여 profiled steel sheeting, 철근 및 콘크리트의 재료비선형을 포함할 수 있는 해석적 방법을 개발하였으며, 합성보의 비선형 모멘트-곡률 관계를 나타낼 수 있는 Power Model식을 제시하였다. Power Model은 원래 보-기둥 접합부의 모멘트-회전각과의 관계를 예측하기 위해 제안된 것이나 합성보에 맞게 수정하였다. 합성보의 하중-처짐 거동은 Power Model에 의한 모멘트-곡률 관계를 이용하여 변위조절법인 단계별 수치적분법을 적용하여 계산하였으며, 실험결과와 비교하였다.

  • PDF